3044092 Phoenix Contact Terminal Blocks

3044092 on Powermatic Associates
Phoenix Contact

Part#:3044092

Manufacturer:Phoenix Contact

Category:Terminal Blocks

Product Lifecycle:Active

Only 4 left in stock. Order Now!

Mar 14, 2025

Product description

Ground modular terminal block, connection method: Screw connection, number of connections: 2, cross section: 0.14 mm² - 4 mm², AWG: 26 - 12, width: 5.2 mm, height: 46.9 mm, color: green-yellow, mounting type: NS 35/7,5, NS 35/15

Product Details

  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Note
    Note: Product releases, connection cross sections and notes on connecting aluminum cables can be found in the download area.
  • Conductor cross section solid min.
    0.14 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    1.5 mm²
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • End cover width
    2.2 mm
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
    0.14 mm²
  • Screw thread
    M3
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • Rated surge voltage
    8 kV
  • Acceleration
    5g
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Degree of pollution
    3
  • Test frequency
    f1 = 5 Hz to f2 = 150 Hz
  • Shock test result
    Test passed
  • Shock duration
    30 ms
  • Conductor cross section flexible max.
    4 mm²
  • 2 conductors with same cross section, solid max.
    1.5 mm²
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • Area of application
    Railway industry
  • Max. AWG conductor cross section, flexible
    12
  • 2 conductors with same cross section, solid min.
    0.14 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
    1.5 mm²
  • Insulating material group
    I
  • Test duration per axis
    5 h
  • Number of shocks per direction
    3
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Height NS 35/7,5
    47.5 mm
  • Conductor cross section solid max.
    4 mm²
  • Connection in acc. with standard
    CSA
  • ECLASS 11.0
    27141141
  • ECLASS 7.0
    27141141
  • ETIM 7.0
    EC000901
  • UNSPSC 20.0
    39121410
  • ETIM 6.0
    EC000901
  • Conductor cross section flexible min.
    0.14 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    2.5 mm²
  • 2 conductors with same cross section, stranded max.
    1.5 mm²
  • Internal cylindrical gage
    A3
  • ECLASS 10.0.1
    27141141
  • ECLASS 4.1
    27141100
  • ECLASS 6.0
    27141100
  • UNSPSC 12.01
    39121410
  • UNSPSC 21.0
    39121410
  • Min. AWG conductor cross section, flexible
    26
  • Conductor cross section AWG min.
    26
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    2.5 mm²
  • 2 conductors with same cross section, stranded min.
    0.14 mm²
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • ASD level
    1.857 (m/s2)2/Hz
  • Shock form
    Half-sine
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Height
    46.9 mm
  • Connection method
    Screw connection
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 5.0
    27141100
  • ETIM 2.0
    EC000901
  • UNSPSC 11
    39121410
  • Length
    47.7 mm
  • Tightening torque, min
    0.5 Nm
  • Conductor cross section AWG max.
    12
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.14 mm²
  • ECLASS 5.1
    27141100
  • ETIM 3.0
    EC000901
  • UNSPSC 7.0901
    39121410
  • UNSPSC 18.0
    39121410
  • UNSPSC 19.0
    39121410
  • UNSPSC 13.2
    39121410
  • ECLASS 9.0
    27141141
  • UNSPSC 6.01
    30211811
  • Number of connections
    2
  • Overvoltage category
    III
  • Test spectrum
    Service life test category 1, class B, body mounted
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Tightening torque max
    0.6 Nm
  • Number of levels
    1
  • Flammability rating according to UL 94
    V0
  • Oscillation, broadband noise test result
    Test passed
  • Static insulating material application in cold
    -60 °C
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Height NS 35/15
    55 mm
  • ETIM 4.0
    EC000901
  • Insulating material
    PA
  • Open side panel
    Yes
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.14 mm²
  • Color
    green-yellow
  • Stripping length
    9 mm
  • Nominal cross section
    2.5 mm²
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Width
    5.2 mm
  • ECLASS 4.0
    27141100

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

3044092 Phoenix Contact

Get a quick Quote!

Request a quote, and we will send you price within minutes.

Stock:

4

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 3044092 with other products

Fire protection for rail ...

Note

Conductor cross section s...

Ambient temperature (stor...

Ambient temperature (asse...

Temperature index of insu...

Two conductors with the s...

Surface flammability NFPA...

End cover width

Ambient temperature (actu...

Two conductors with the s...

Screw thread

China RoHS

Rated surge voltage

Acceleration

Test directions

Degree of pollution

Test frequency

Shock test result

Shock duration

Conductor cross section f...

2 conductors with same cr...

Operating temperature

Area of application

Max. AWG conductor cross ...

2 conductors with same cr...

Two conductors with the s...

Two conductors with the s...

Insulating material group

Test duration per axis

Number of shocks per dire...

Specific optical density ...

Height NS 35/7,5

Conductor cross section s...

Connection in acc. with s...

ECLASS 11.0

ECLASS 7.0

ETIM 7.0

UNSPSC 20.0

ETIM 6.0

Conductor cross section f...

Conductor cross section f...

2 conductors with same cr...

Internal cylindrical gage

ECLASS 10.0.1

ECLASS 4.1

ECLASS 6.0

UNSPSC 12.01

UNSPSC 21.0

Min. AWG conductor cross ...

Conductor cross section A...

Conductor cross section f...

2 conductors with same cr...

Test specification, oscil...

ASD level

Shock form

Relative insulation mater...

Fire protection for rail ...

Fire protection for rail ...

Height

Connection method

Permissible humidity (sto...

ECLASS 5.0

ETIM 2.0

UNSPSC 11

Length

Tightening torque, min

Conductor cross section A...

Conductor cross section f...

ECLASS 5.1

ETIM 3.0

UNSPSC 7.0901

UNSPSC 18.0

UNSPSC 19.0

UNSPSC 13.2

ECLASS 9.0

UNSPSC 6.01

Number of connections

Overvoltage category

Test spectrum

Calorimetric heat release...

Tightening torque max

Number of levels

Flammability rating accor...

Oscillation, broadband no...

Static insulating materia...

Smoke gas toxicity NFPA 1...

Height NS 35/15

ETIM 4.0

Insulating material

Open side panel

Conductor cross section f...

Color

Stripping length

Nominal cross section

Fire protection for rail ...

Width

ECLASS 4.0

Maximum power dissipation...

Nominal voltage UN

Result of the test for me...

Power frequency withstand...

Tight fit on carrier

Requirement temperature-r...

Result of thermal test

Conductor cross section s...

Maximum load current

Nominal current IN

Bending test turns

Back of the hand protecti...

Result of flexion and pul...

Result of voltage-drop te...

Potentials

Shock protection test spe...

Finger protection

Bending test rotation spe...

Bending test conductor cr...

Short circuit stability r...

Result of power-frequency...

Tensile test result

Short-time current

Test specification, shock...

Result of surge voltage t...

Result of tight fit on su...

Setpoint

Result of temperature-ris...

Proof of thermal characte...

Selected product

3044092
4 in stock
3044092
Phoenix Contact

Ground modular terminal block, connection method: Screw connection, number of connections: 2, cross ...

Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

NoteNote: Product releases, conn...

Conductor cross section solid min.0.14 mm²

Ambient temperature (storage/transport)-25 °C ... 60 °C (for a shor...

Ambient temperature (assembly)-5 °C ... 70 °C

Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C

Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum1.5 mm²

Surface flammability NFPA 130 (ASTM E 162)passed

End cover width2.2 mm

Ambient temperature (actuation)-5 °C ... 70 °C

Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum0.14 mm²

Screw threadM3

China RoHSEnvironmentally Friendly Use...

Rated surge voltage8 kV

Acceleration5g

Test directionsX-, Y- and Z-axis (pos. and ...

Degree of pollution3

Test frequencyf1 = 5 Hz to f2 = 150 Hz

Shock test resultTest passed

Shock duration30 ms

Conductor cross section flexible max.4 mm²

2 conductors with same cross section, solid max.1.5 mm²

Operating temperature-60 °C ... 105 °C (max. shor...

Area of applicationRailway industry

Max. AWG conductor cross section, flexible12

2 conductors with same cross section, solid min.0.14 mm²

Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum0.5 mm²

Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum1.5 mm²

Insulating material groupI

Test duration per axis5 h

Number of shocks per direction3

Specific optical density of smoke NFPA 130 (ASTM E 662)passed

Height NS 35/7,547.5 mm

Conductor cross section solid max.4 mm²

Connection in acc. with standardCSA

ECLASS 11.027141141

ECLASS 7.027141141

ETIM 7.0EC000901

UNSPSC 20.039121410

ETIM 6.0EC000901

Conductor cross section flexible min.0.14 mm²

Conductor cross section flexible, with ferrule with plastic sleeve max.2.5 mm²

2 conductors with same cross section, stranded max.1.5 mm²

Internal cylindrical gageA3

ECLASS 10.0.127141141

ECLASS 4.127141100

ECLASS 6.027141100

UNSPSC 12.0139121410

UNSPSC 21.039121410

Min. AWG conductor cross section, flexible26

Conductor cross section AWG min.26

Conductor cross section flexible, with ferrule without plastic sleeve max.2.5 mm²

2 conductors with same cross section, stranded min.0.14 mm²

Test specification, oscillation, broadband noiseDIN EN 50155 (VDE 0115-200):...

ASD level1.857 (m/s2)2/Hz

Shock formHalf-sine

Relative insulation material temperature index (Elec., UL 746 B)130 °C

Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3

Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3

Height46.9 mm

Connection methodScrew connection

Permissible humidity (storage/transport)30 % ... 70 %

ECLASS 5.027141100

ETIM 2.0EC000901

UNSPSC 1139121410

Length47.7 mm

Tightening torque, min0.5 Nm

Conductor cross section AWG max.12

Conductor cross section flexible, with ferrule without plastic sleeve min.0.14 mm²

ECLASS 5.127141100

ETIM 3.0EC000901

UNSPSC 7.090139121410

UNSPSC 18.039121410

UNSPSC 19.039121410

UNSPSC 13.239121410

ECLASS 9.027141141

UNSPSC 6.0130211811

Number of connections2

Overvoltage categoryIII

Test spectrumService life test category 1...

Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg

Tightening torque max0.6 Nm

Number of levels1

Flammability rating according to UL 94V0

Oscillation, broadband noise test resultTest passed

Static insulating material application in cold-60 °C

Smoke gas toxicity NFPA 130 (SMP 800C)passed

Height NS 35/1555 mm

ETIM 4.0EC000901

Insulating materialPA

Open side panelYes

Conductor cross section flexible, with ferrule with plastic sleeve min.0.14 mm²

Colorgreen-yellow

Stripping length9 mm

Nominal cross section2.5 mm²

Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3

Width5.2 mm

ECLASS 4.027141100

Maximum power dissipation for nominal condition-

Nominal voltage UN-

Result of the test for mechanical stability of terminal points (5 x conductor connection)-

Power frequency withstand voltage setpoint-

Tight fit on carrier-

Requirement temperature-rise test-

Result of thermal test-

Conductor cross section short circuit testing-

Maximum load current-

Nominal current IN-

Bending test turns-

Back of the hand protection-

Result of flexion and pull-out test-

Result of voltage-drop test-

Potentials-

Shock protection test specification-

Finger protection-

Bending test rotation speed-

Bending test conductor cross section/weight-

Short circuit stability result-

Result of power-frequency withstand voltage test-

Tensile test result-

Short-time current-

Test specification, shock test-

Result of surge voltage test-

Result of tight fit on support-

Setpoint-

Result of temperature-rise test-

Proof of thermal characteristics (needle flame) effective duration-

3045088
6 in stock
3045088
Phoenix Contact

Feed-through terminal block, nom. voltage: 1000 V, nominal current: 24 A, connection method: Screw c...

Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

NoteNote: Product releases, conn...

Conductor cross section solid min.0.14 mm²

Ambient temperature (storage/transport)-25 °C ... 60 °C (for a shor...

Ambient temperature (assembly)-5 °C ... 70 °C

Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C

Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum1.5 mm²

Surface flammability NFPA 130 (ASTM E 162)passed

End cover width2.2 mm

Ambient temperature (actuation)-5 °C ... 70 °C

Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum0.14 mm²

Screw threadM3

China RoHSEnvironmentally Friendly Use...

Rated surge voltage8 kV

Acceleration5g

Test directionsX-, Y- and Z-axis (pos. and ...

Degree of pollution3

Test frequencyf1 = 5 Hz to f2 = 150 Hz

Shock test resultTest passed

Shock duration30 ms

Conductor cross section flexible max.2.5 mm²

2 conductors with same cross section, solid max.1.5 mm²

Operating temperature-60 °C ... 105 °C (max. shor...

Area of applicationRailway industry

Max. AWG conductor cross section, flexible12

2 conductors with same cross section, solid min.0.14 mm²

Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum0.5 mm²

Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum1.5 mm²

Insulating material groupI

Test duration per axis5 h

Number of shocks per direction3

Specific optical density of smoke NFPA 130 (ASTM E 662)passed

Height NS 35/7,547.5 mm

Conductor cross section solid max.4 mm²

Connection in acc. with standardCSA

ECLASS 11.027141120

ECLASS 7.027141120

ETIM 7.0EC000897

UNSPSC 20.039121410

ETIM 6.0EC000897

Conductor cross section flexible min.0.14 mm²

Conductor cross section flexible, with ferrule with plastic sleeve max.2.5 mm²

2 conductors with same cross section, stranded max.1.5 mm²

Internal cylindrical gageA3

ECLASS 10.0.127141120

ECLASS 4.127141100

ECLASS 6.027141100

UNSPSC 12.0139121410

UNSPSC 21.039121410

Min. AWG conductor cross section, flexible26

Conductor cross section AWG min.26

Conductor cross section flexible, with ferrule without plastic sleeve max.2.5 mm²

2 conductors with same cross section, stranded min.0.14 mm²

Test specification, oscillation, broadband noiseDIN EN 50155 (VDE 0115-200):...

ASD level1.857 (m/s2)2/Hz

Shock formHalf-sine

Relative insulation material temperature index (Elec., UL 746 B)130 °C

Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3

Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3

Height-

Connection methodScrew connection

Permissible humidity (storage/transport)30 % ... 70 %

ECLASS 5.027141100

ETIM 2.0EC000897

UNSPSC 1139121410

Length47.7 mm

Tightening torque, min0.5 Nm

Conductor cross section AWG max.12

Conductor cross section flexible, with ferrule without plastic sleeve min.0.14 mm²

ECLASS 5.127141100

ETIM 3.0EC000897

UNSPSC 7.090139121410

UNSPSC 18.039121410

UNSPSC 19.039121410

UNSPSC 13.239121410

ECLASS 9.027141120

UNSPSC 6.0130211811

Number of connections2

Overvoltage categoryIII

Test spectrumService life test category 1...

Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg

Tightening torque max0.6 Nm

Number of levels1

Flammability rating according to UL 94V0

Oscillation, broadband noise test resultTest passed

Static insulating material application in cold-60 °C

Smoke gas toxicity NFPA 130 (SMP 800C)passed

Height NS 35/1555 mm

ETIM 4.0EC000897

Insulating materialPA

Open side panelYes

Conductor cross section flexible, with ferrule with plastic sleeve min.0.14 mm²

Colorblack

Stripping length9 mm

Nominal cross section2.5 mm²

Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3

Width5.2 mm

ECLASS 4.027141100

Maximum power dissipation for nominal condition0.77 W

Nominal voltage UN1000 V

Result of the test for mechanical stability of terminal points (5 x conductor connection)Test passed

Power frequency withstand voltage setpoint2.2 kV

Tight fit on carrierNS 35

Requirement temperature-rise testIncrease in temperature ≤ 45...

Result of thermal testTest passed

Conductor cross section short circuit testing4 mm²

Maximum load current32 A (with 4 mm² conductor c...

Nominal current IN24 A

Bending test turns135

Back of the hand protectionguaranteed

Result of flexion and pull-out testTest passed

Result of voltage-drop testTest passed

Potentials1

Shock protection test specificationDIN EN 50274 (VDE 0660-514):...

Finger protectionguaranteed

Bending test rotation speed10 rpm

Bending test conductor cross section/weight0.14 mm² / 0.2 kg

Short circuit stability resultTest passed

Result of power-frequency withstand voltage testTest passed

Tensile test resultTest passed

Short-time current0.48 kA

Test specification, shock testDIN EN 50155 (VDE 0115-200):...

Result of surge voltage testTest passed

Result of tight fit on supportTest passed

Setpoint1 N

Result of temperature-rise testTest passed

Proof of thermal characteristics (needle flame) effective duration30 s

3044542
32 in stock
3044542
Phoenix Contact

Feed-through terminal block, nom. voltage: 500 V, nominal current: 24 A, connection method: Screw co...

Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Note-

Conductor cross section solid min.0.14 mm²

Ambient temperature (storage/transport)-25 °C ... 60 °C (for a shor...

Ambient temperature (assembly)-5 °C ... 70 °C

Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))125 °C

Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum1 mm²

Surface flammability NFPA 130 (ASTM E 162)passed

End cover width2.2 mm

Ambient temperature (actuation)-5 °C ... 70 °C

Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum0.14 mm²

Screw threadM3

China RoHSEnvironmentally Friendly Use...

Rated surge voltage6 kV

Acceleration5g

Test directionsX-, Y- and Z-axis (pos. and ...

Degree of pollution3

Test frequencyf1 = 5 Hz to f2 = 150 Hz

Shock test resultTest passed

Shock duration30 ms

Conductor cross section flexible max.4 mm²

2 conductors with same cross section, solid max.1.5 mm²

Operating temperature-60 °C ... 105 °C (max. shor...

Area of applicationRailway industry

Max. AWG conductor cross section, flexible12

2 conductors with same cross section, solid min.0.14 mm²

Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum0.5 mm²

Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum1.5 mm²

Insulating material groupI

Test duration per axis5 h

Number of shocks per direction3

Specific optical density of smoke NFPA 130 (ASTM E 662)passed

Height NS 35/7,547.5 mm

Conductor cross section solid max.4 mm²

Connection in acc. with standardCSA

ECLASS 11.027141120

ECLASS 7.027141120

ETIM 7.0EC000897

UNSPSC 20.039121410

ETIM 6.0EC000897

Conductor cross section flexible min.0.14 mm²

Conductor cross section flexible, with ferrule with plastic sleeve max.2.5 mm²

2 conductors with same cross section, stranded max.1.5 mm²

Internal cylindrical gageA3

ECLASS 10.0.127141120

ECLASS 4.127141100

ECLASS 6.027141100

UNSPSC 12.0139121410

UNSPSC 21.039121410

Min. AWG conductor cross section, flexible26

Conductor cross section AWG min.26

Conductor cross section flexible, with ferrule without plastic sleeve max.2.5 mm²

2 conductors with same cross section, stranded min.0.14 mm²

Test specification, oscillation, broadband noiseDIN EN 50155 (VDE 0115-200):...

ASD level1.857 (m/s2)2/Hz

Shock formHalf-sine

Relative insulation material temperature index (Elec., UL 746 B)130 °C

Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3

Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3

Height46.9 mm

Connection methodScrew connection

Permissible humidity (storage/transport)30 % ... 70 %

ECLASS 5.027141100

ETIM 2.0EC000901

UNSPSC 1139121410

Length65.4 mm

Tightening torque, min0.5 Nm

Conductor cross section AWG max.12

Conductor cross section flexible, with ferrule without plastic sleeve min.0.14 mm²

ECLASS 5.127141100

ETIM 3.0EC000901

UNSPSC 7.090139121410

UNSPSC 18.039121410

UNSPSC 19.039121410

UNSPSC 13.239121410

ECLASS 9.027141120

UNSPSC 6.0130211811

Number of connections4

Overvoltage categoryIII

Test spectrumService life test category 1...

Calorimetric heat release NFPA 130 (ASTM E 1354)27,5 MJ/kg

Tightening torque max0.6 Nm

Number of levels1

Flammability rating according to UL 94V0

Oscillation, broadband noise test resultTest passed

Static insulating material application in cold-60 °C

Smoke gas toxicity NFPA 130 (SMP 800C)passed

Height NS 35/1555 mm

ETIM 4.0EC000897

Insulating materialPA

Open side panelYes

Conductor cross section flexible, with ferrule with plastic sleeve min.0.14 mm²

Colorgray

Stripping length9 mm

Nominal cross section2.5 mm²

Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3

Width5.2 mm

ECLASS 4.027141100

Maximum power dissipation for nominal condition0.77 W

Nominal voltage UN500 V

Result of the test for mechanical stability of terminal points (5 x conductor connection)Test passed

Power frequency withstand voltage setpoint1.89 kV

Tight fit on carrierNS 35

Requirement temperature-rise testIncrease in temperature ≤ 45...

Result of thermal testTest passed

Conductor cross section short circuit testing4 mm²

Maximum load current30 A (in case of a 4 mm² con...

Nominal current IN24 A

Bending test turns135

Back of the hand protectionguaranteed

Result of flexion and pull-out testTest passed

Result of voltage-drop testTest passed

Potentials1

Shock protection test specificationDIN EN 50274 (VDE 0660-514):...

Finger protectionguaranteed

Bending test rotation speed10 rpm

Bending test conductor cross section/weight0.14 mm² / 0.2 kg

Short circuit stability resultTest passed

Result of power-frequency withstand voltage testTest passed

Tensile test resultTest passed

Short-time current0.48 kA

Test specification, shock testDIN EN 50155 (VDE 0115-200):...

Result of surge voltage testTest passed

Result of tight fit on supportTest passed

Setpoint1 N

Result of temperature-rise testTest passed

Proof of thermal characteristics (needle flame) effective duration30 s

About the manufacturer

Phoenix Contact

Powermatic Associates is an authorized Phoenix Contact distributor, proudly offering a wide array of innovative industrial solutions that cater to modern technological demands. Phoenix Contact is a global leader renowned for its high-quality products in the fields of electrical engineering and automation technology. Their extensive catalog encompasses everything from connection technology, interface systems, and surge protection to automation software and control technology, making them a versatile choice for various industrial applications. At Powermatic Associates, we deliver Phoenix Contact’s pioneering connectivity and power management solutions, which include terminal blocks, connectors, relays, and PLCs. These components are essential for creating efficient and reliable electrical connections in diverse environments, ensuring seamless system integration. The company's comprehensive range of Industrial Internet of Things (IIoT) solutions facilitates intelligent networking, enabling customers to optimize their automation processes with cutting-edge technology. Phoenix Contact's emphasis on sustainability and innovation reflects in their energy management systems and renewable energy solutions. By incorporating these into your operations, you not only enhance efficiency but also contribute to sustainable practices, aligning with modern environmental standards. Powermatic Associates recognizes the significance of such advancements and partners with Phoenix Contact to provide expert engineering support and tailored solutions, helping you implement smart technologies that drive productivity and minimize costs. With a focus on safety and reliability, Phoenix Contact offers advanced surge protection devices and signal conditioners that safeguard your equipment against voltage spikes and ensure data integrity. In collaboration with Powermatic Associates, customers gain access to robust technical support and consultation, ensuring that every project benefits from personalized guidance and quick resolution of technical challenges. Our partnership extends the reach of Phoenix Contact’s globally recognized industrial automation products, including Human Machine Interfaces (HMIs) and Ethernet switches, empowering businesses with enhanced operational control and communication capabilities. Customers can trust Powermatic Associates to deliver prompt shipping and thorough assistance, ensuring that Phoenix Contact’s top-tier products are seamlessly integrated into their workflows for optimal performance.

Recently viewed products

Relevant products

FAQ

4 in stock

Ground modular terminal block, connection method: Screw connection, number of connections: 2, cross section: 0.14 mm² - 4 mm², AWG: 26 - 12, width: 5.2 mm, height: 46.9 mm, color: green-yellow, mounting type: NS 35/7,5, NS 35/15

Similar products from: Terminal Blocks

What can I help you find today?

Recommended parts