3044814 Phoenix Contact Terminal Blocks

3044814 on Powermatic Associates
Phoenix Contact

Part#:3044814

Manufacturer:Phoenix Contact

Category:Terminal Blocks

Product Lifecycle:Active

40 in stock

Mar 14, 2025

Product description

Double-level terminal block, connection method: Screw connection, cross section: 0.14 mm² - 6 mm², AWG: 26 - 10, width: 6.2 mm, color: gray, mounting type: NS 35/7,5, NS 35/15

Product Details

  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 5.0
    27141100
  • ETIM 3.0
    EC000901
  • ETIM 7.0
    EC000897
  • UNSPSC 20.0
    39121410
  • Test duration per axis
    5 h
  • Insulating material group
    I
  • Nominal voltage UN
    800 V
  • Bending test rotation speed
    10 rpm
  • Tight fit on carrier
    NS 35
  • Setpoint
    1 N
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Number of shocks per direction
    3
  • Static insulating material application in cold
    -60 °C
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Conductor cross section solid min.
    0.14 mm²
  • Conductor cross section AWG min.
    26
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    4 mm²
  • 2 conductors with same cross section, stranded max.
    1.5 mm²
  • Internal cylindrical gage
    A4
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • Area of application
    Railway industry
  • Overvoltage category
    III
  • Power frequency withstand voltage setpoint
    2 kV
  • Result of temperature-rise test
    Test passed
  • Result of tight fit on support
    Test passed
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Acceleration
    30g
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Height NS 35/7,5
    65 mm
  • Height NS 35/15
    72.5 mm
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    4 mm²
  • 2 conductors with same cross section, solid min.
    0.14 mm²
  • 2 conductors with same cross section, stranded min.
    0.14 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    2.5 mm²
  • Stripping length
    9 mm
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.14 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
    0.14 mm²
  • Rated surge voltage
    8 kV
  • Maximum load current
    36 A (with 6 mm² conductor cross section)
  • Checking the mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Result of surge voltage test
    Test passed
  • Bending test conductor cross section/weight
    0.14 mm² / 0.2 kg
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Shock test result
    Test passed
  • Relative insulation material temperature index (Elec.; UL 746 B)
    130 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • End cover width
    2.2 mm
  • Conductor cross section flexible min.
    0.14 mm²
  • Conductor cross section solid max.
    6 mm²
  • Tightening torque, min
    0.6 Nm
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 4.1
    27141100
  • ECLASS 6.0
    27141100
  • ETIM 6.0
    EC000897
  • Degree of pollution
    3
  • Nominal current IN
    30 A
  • Bending test turns
    135
  • Short circuit stability result
    Test passed
  • Shock form
    Half-sine
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Width
    6.2 mm
  • Connection method
    Screw connection
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.14 mm²
  • 2 conductors with same cross section, solid max.
    1.5 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • Tightening torque max
    0.8 Nm
  • ECLASS 10.0.1
    27141120
  • ECLASS 7.0
    27141120
  • UNSPSC 12.01
    39121410
  • UNSPSC 7.0901
    39121410
  • Conductor cross section short circuit testing
    4 mm²
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2018-05
  • ASD level
    6.12 (m/s2)2/Hz
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Result of power-frequency withstand voltage test
    Test passed
  • Result of flexion and pull-out test
    Test passed
  • Shock duration
    18 ms
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Length
    69.9 mm
  • Conductor cross section AWG max.
    10
  • Conductor cross section flexible max.
    6 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
    1.5 mm²
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 5.1
    27141100
  • ETIM 2.0
    EC000901
  • UNSPSC 6.01
    30211811
  • UNSPSC 21.0
    39121410
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • ECLASS 11.0
    27141120
  • ECLASS 4.0
    27141100
  • ETIM 4.0
    EC000897
  • ECLASS 9.0
    27141120
  • UNSPSC 13.2
    39121410
  • Number of levels
    2
  • Back of the hand protection
    guaranteed
  • Result of thermal test
    Test passed
  • Flammability rating according to UL 94
    V0
  • Color
    gray
  • Connection in acc. with standard
    CSA
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Screw thread
    M3
  • UNSPSC 11
    39121410
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • UNSPSC 18.0
    39121410
  • Nominal cross section
    4 mm²
  • Maximum power dissipation for nominal condition
    1.02 W (the value is multiplied when connecting multiple levels)
  • Open side panel
    Yes
  • Insulating material
    PA
  • Finger protection
    guaranteed
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • UNSPSC 19.0
    39121410
  • Number of connections
    4
  • Short-time current
    0.48 kA

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

3044814 Phoenix Contact

Get a quick Quote!

Request a quote, and we will send you price within minutes.

Stock:

40

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 3044814 with other products

China RoHS

ECLASS 5.0

ETIM 3.0

ETIM 7.0

UNSPSC 20.0

Test duration per axis

Insulating material group

Nominal voltage UN

Bending test rotation spe...

Tight fit on carrier

Setpoint

Proof of thermal characte...

Test specification, shock...

Number of shocks per dire...

Static insulating materia...

Calorimetric heat release...

Fire protection for rail ...

Conductor cross section s...

Conductor cross section A...

Conductor cross section f...

2 conductors with same cr...

Internal cylindrical gage

Permissible humidity (sto...

Area of application

Overvoltage category

Power frequency withstand...

Result of temperature-ris...

Result of tight fit on su...

Test spectrum

Acceleration

Surface flammability NFPA...

Fire protection for rail ...

Height NS 35/7,5

Height NS 35/15

Conductor cross section f...

2 conductors with same cr...

2 conductors with same cr...

Two conductors with the s...

Stripping length

Operating temperature

Conductor cross section f...

Two conductors with the s...

Rated surge voltage

Maximum load current

Checking the mechanical s...

Result of surge voltage t...

Bending test conductor cr...

Ageing test for screwless...

Test frequency

Shock test result

Relative insulation mater...

Fire protection for rail ...

End cover width

Conductor cross section f...

Conductor cross section s...

Tightening torque, min

Ambient temperature (asse...

ECLASS 4.1

ECLASS 6.0

ETIM 6.0

Degree of pollution

Nominal current IN

Bending test turns

Short circuit stability r...

Shock form

Specific optical density ...

Width

Connection method

Conductor cross section f...

2 conductors with same cr...

Two conductors with the s...

Tightening torque max

ECLASS 10.0.1

ECLASS 7.0

UNSPSC 12.01

UNSPSC 7.0901

Conductor cross section s...

Test specification, oscil...

ASD level

Shock protection test spe...

Result of power-frequency...

Result of flexion and pul...

Shock duration

Smoke gas toxicity NFPA 1...

Length

Conductor cross section A...

Conductor cross section f...

Two conductors with the s...

Ambient temperature (actu...

ECLASS 5.1

ETIM 2.0

UNSPSC 6.01

UNSPSC 21.0

Ambient temperature (stor...

ECLASS 11.0

ECLASS 4.0

ETIM 4.0

ECLASS 9.0

UNSPSC 13.2

Number of levels

Back of the hand protecti...

Result of thermal test

Flammability rating accor...

Color

Connection in acc. with s...

Test directions

Screw thread

UNSPSC 11

Fire protection for rail ...

UNSPSC 18.0

Nominal cross section

Maximum power dissipation...

Open side panel

Insulating material

Finger protection

Temperature index of insu...

UNSPSC 19.0

Number of connections

Short-time current

Tensile test result

Result of voltage-drop te...

Tractive force setpoint

Conductor cross section t...

Requirements, voltage dro...

Oscillation, broadband no...

Height

Note

Min. AWG conductor cross ...

Max. AWG conductor cross ...

Result of the test for me...

Potentials

Relative insulation mater...

Requirement temperature-r...

Selected product

3044814
40 in stock
3044814
Phoenix Contact

Double-level terminal block, connection method: Screw connection, cross section: 0.14 mm² - 6 mm², A...

China RoHSEnvironmentally Friendly Use...

ECLASS 5.027141100

ETIM 3.0EC000901

ETIM 7.0EC000897

UNSPSC 20.039121410

Test duration per axis5 h

Insulating material groupI

Nominal voltage UN800 V

Bending test rotation speed10 rpm

Tight fit on carrierNS 35

Setpoint1 N

Proof of thermal characteristics (needle flame) effective duration30 s

Test specification, shock testDIN EN 50155 (VDE 0115-200):...

Number of shocks per direction3

Static insulating material application in cold-60 °C

Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg

Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3

Conductor cross section solid min.0.14 mm²

Conductor cross section AWG min.26

Conductor cross section flexible, with ferrule with plastic sleeve max.4 mm²

2 conductors with same cross section, stranded max.1.5 mm²

Internal cylindrical gageA4

Permissible humidity (storage/transport)30 % ... 70 %

Area of applicationRailway industry

Overvoltage categoryIII

Power frequency withstand voltage setpoint2 kV

Result of temperature-rise testTest passed

Result of tight fit on supportTest passed

Test spectrumService life test category 2...

Acceleration30g

Surface flammability NFPA 130 (ASTM E 162)passed

Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3

Height NS 35/7,565 mm

Height NS 35/1572.5 mm

Conductor cross section flexible, with ferrule without plastic sleeve max.4 mm²

2 conductors with same cross section, solid min.0.14 mm²

2 conductors with same cross section, stranded min.0.14 mm²

Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum2.5 mm²

Stripping length9 mm

Operating temperature-60 °C ... 105 °C (max. shor...

Conductor cross section flexible, with ferrule with plastic sleeve min.0.14 mm²

Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum0.14 mm²

Rated surge voltage8 kV

Maximum load current36 A (with 6 mm² conductor c...

Checking the mechanical stability of terminal points (5 x conductor connection)Test passed

Result of surge voltage testTest passed

Bending test conductor cross section/weight0.14 mm² / 0.2 kg

Ageing test for screwless modular terminal block temperature cycles192

Test frequencyf1 = 5 Hz to f2 = 250 Hz

Shock test resultTest passed

Relative insulation material temperature index (Elec.; UL 746 B)130 °C

Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

End cover width2.2 mm

Conductor cross section flexible min.0.14 mm²

Conductor cross section solid max.6 mm²

Tightening torque, min0.6 Nm

Ambient temperature (assembly)-5 °C ... 70 °C

ECLASS 4.127141100

ECLASS 6.027141100

ETIM 6.0EC000897

Degree of pollution3

Nominal current IN30 A

Bending test turns135

Short circuit stability resultTest passed

Shock formHalf-sine

Specific optical density of smoke NFPA 130 (ASTM E 662)passed

Width6.2 mm

Connection methodScrew connection

Conductor cross section flexible, with ferrule without plastic sleeve min.0.14 mm²

2 conductors with same cross section, solid max.1.5 mm²

Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum0.5 mm²

Tightening torque max0.8 Nm

ECLASS 10.0.127141120

ECLASS 7.027141120

UNSPSC 12.0139121410

UNSPSC 7.090139121410

Conductor cross section short circuit testing4 mm²

Test specification, oscillation, broadband noiseDIN EN 50155 (VDE 0115-200):...

ASD level6.12 (m/s2)2/Hz

Shock protection test specificationDIN EN 50274 (VDE 0660-514):...

Result of power-frequency withstand voltage testTest passed

Result of flexion and pull-out testTest passed

Shock duration18 ms

Smoke gas toxicity NFPA 130 (SMP 800C)passed

Length69.9 mm

Conductor cross section AWG max.10

Conductor cross section flexible max.6 mm²

Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum1.5 mm²

Ambient temperature (actuation)-5 °C ... 70 °C

ECLASS 5.127141100

ETIM 2.0EC000901

UNSPSC 6.0130211811

UNSPSC 21.039121410

Ambient temperature (storage/transport)-25 °C ... 60 °C (for a shor...

ECLASS 11.027141120

ECLASS 4.027141100

ETIM 4.0EC000897

ECLASS 9.027141120

UNSPSC 13.239121410

Number of levels2

Back of the hand protectionguaranteed

Result of thermal testTest passed

Flammability rating according to UL 94V0

Colorgray

Connection in acc. with standardCSA

Test directionsX-, Y- and Z-axis (pos. and ...

Screw threadM3

UNSPSC 1139121410

Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3

UNSPSC 18.039121410

Nominal cross section4 mm²

Maximum power dissipation for nominal condition1.02 W (the value is multipl...

Open side panelYes

Insulating materialPA

Finger protectionguaranteed

Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C

UNSPSC 19.039121410

Number of connections4

Short-time current0.48 kA

Tensile test result-

Result of voltage-drop test-

Tractive force setpoint-

Conductor cross section tensile test-

Requirements, voltage drop-

Oscillation, broadband noise test result-

Height-

Note-

Min. AWG conductor cross section, flexible-

Max. AWG conductor cross section, flexible-

Result of the test for mechanical stability of terminal points (5 x conductor connection)-

Potentials-

Relative insulation material temperature index (Elec., UL 746 B)-

Requirement temperature-rise test-

3044636
428 in stock
3044636
Phoenix Contact

Double-level terminal block, connection method: Screw connection, cross section: 0.14 mm² - 4 mm², A...

China RoHSEnvironmentally Friendly Use...

ECLASS 5.027141100

ETIM 3.0EC000901

ETIM 7.0EC000897

UNSPSC 20.039121410

Test duration per axis5 h

Insulating material groupI

Nominal voltage UN500 V

Bending test rotation speed10 rpm

Tight fit on carrierNS 35

Setpoint1 N

Proof of thermal characteristics (needle flame) effective duration30 s

Test specification, shock testDIN EN 50155 (VDE 0115-200):...

Number of shocks per direction3

Static insulating material application in cold-60 °C

Calorimetric heat release NFPA 130 (ASTM E 1354)27,5 MJ/kg

Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3

Conductor cross section solid min.0.14 mm²

Conductor cross section AWG min.26

Conductor cross section flexible, with ferrule with plastic sleeve max.2.5 mm²

2 conductors with same cross section, stranded max.1.5 mm²

Internal cylindrical gageA3

Permissible humidity (storage/transport)30 % ... 70 %

Area of applicationRailway industry

Overvoltage categoryIII

Power frequency withstand voltage setpoint1.89 kV

Result of temperature-rise testTest passed

Result of tight fit on supportTest passed

Test spectrumService life test category 1...

Acceleration5g

Surface flammability NFPA 130 (ASTM E 162)passed

Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3

Height NS 35/7,565 mm

Height NS 35/1572.5 mm

Conductor cross section flexible, with ferrule without plastic sleeve max.2.5 mm²

2 conductors with same cross section, solid min.0.14 mm²

2 conductors with same cross section, stranded min.0.14 mm²

Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum1.5 mm²

Stripping length9 mm

Operating temperature-60 °C ... 105 °C (max. shor...

Conductor cross section flexible, with ferrule with plastic sleeve min.0.14 mm²

Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum0.14 mm²

Rated surge voltage6 kV

Maximum load current28 A (in case of a 4 mm² con...

Checking the mechanical stability of terminal points (5 x conductor connection)Test passed

Result of surge voltage testTest passed

Bending test conductor cross section/weight0.14 mm² / 0.2 kg

Ageing test for screwless modular terminal block temperature cycles-

Test frequencyf1 = 5 Hz to f2 = 150 Hz

Shock test resultTest passed

Relative insulation material temperature index (Elec.; UL 746 B)130 °C

Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

End cover width2.2 mm

Conductor cross section flexible min.0.14 mm²

Conductor cross section solid max.4 mm²

Tightening torque, min0.5 Nm

Ambient temperature (assembly)-5 °C ... 70 °C

ECLASS 4.127141100

ECLASS 6.027141100

ETIM 6.0EC000897

Degree of pollution3

Nominal current IN24 A

Bending test turns135

Short circuit stability resultTest passed

Shock formHalf-sine

Specific optical density of smoke NFPA 130 (ASTM E 662)passed

Width5.2 mm

Connection methodScrew connection

Conductor cross section flexible, with ferrule without plastic sleeve min.0.14 mm²

2 conductors with same cross section, solid max.1.5 mm²

Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum0.5 mm²

Tightening torque max0.6 Nm

ECLASS 10.0.127141120

ECLASS 7.027141120

UNSPSC 12.0139121410

UNSPSC 7.090139121410

Conductor cross section short circuit testing4 mm²

Test specification, oscillation, broadband noiseDIN EN 50155 (VDE 0115-200):...

ASD level1.857 (m/s2)2/Hz

Shock protection test specificationDIN EN 50274 (VDE 0660-514):...

Result of power-frequency withstand voltage testTest passed

Result of flexion and pull-out testTest passed

Shock duration30 ms

Smoke gas toxicity NFPA 130 (SMP 800C)passed

Length69.9 mm

Conductor cross section AWG max.12

Conductor cross section flexible max.4 mm²

Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum1.5 mm²

Ambient temperature (actuation)-5 °C ... 70 °C

ECLASS 5.127141100

ETIM 2.0EC000901

UNSPSC 6.0130211811

UNSPSC 21.039121410

Ambient temperature (storage/transport)-25 °C ... 60 °C (for a shor...

ECLASS 11.027141120

ECLASS 4.027141100

ETIM 4.0EC001329

ECLASS 9.027141120

UNSPSC 13.239121410

Number of levels2

Back of the hand protectionguaranteed

Result of thermal testTest passed

Flammability rating according to UL 94V0

Colorgray

Connection in acc. with standardCSA

Test directionsX-, Y- and Z-axis (pos. and ...

Screw threadM3

UNSPSC 1139121410

Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3

UNSPSC 18.039121410

Nominal cross section2.5 mm²

Maximum power dissipation for nominal condition0.77 W (the value is multipl...

Open side panelYes

Insulating materialPA

Finger protectionguaranteed

Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))125 °C

UNSPSC 19.039121410

Number of connections4

Short-time current0.48 kA

Tensile test resultTest passed

Result of voltage-drop testTest passed

Tractive force setpoint60 N

Conductor cross section tensile test4 mm²

Requirements, voltage drop≤ 3.2 mV

Oscillation, broadband noise test resultTest passed

Height64.4 mm

Note-

Min. AWG conductor cross section, flexible-

Max. AWG conductor cross section, flexible-

Result of the test for mechanical stability of terminal points (5 x conductor connection)-

Potentials-

Relative insulation material temperature index (Elec., UL 746 B)-

Requirement temperature-rise test-

3044102
94 in stock
3044102
Phoenix Contact

Feed-through terminal block, nom. voltage: 1000 V, nominal current: 32 A, connection method: Screw c...

China RoHSEnvironmentally Friendly Use...

ECLASS 5.027141100

ETIM 3.0EC000897

ETIM 7.0EC000897

UNSPSC 20.039121410

Test duration per axis5 h

Insulating material groupI

Nominal voltage UN1000 V

Bending test rotation speed10 rpm

Tight fit on carrierNS 35

Setpoint1 N

Proof of thermal characteristics (needle flame) effective duration30 s

Test specification, shock testDIN EN 50155 (VDE 0115-200):...

Number of shocks per direction3

Static insulating material application in cold-60 °C

Calorimetric heat release NFPA 130 (ASTM E 1354)27,5 MJ/kg

Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3

Conductor cross section solid min.0.14 mm²

Conductor cross section AWG min.26

Conductor cross section flexible, with ferrule with plastic sleeve max.4 mm²

2 conductors with same cross section, stranded max.1.5 mm²

Internal cylindrical gageA4

Permissible humidity (storage/transport)30 % ... 70 %

Area of applicationRailway industry

Overvoltage categoryIII

Power frequency withstand voltage setpoint2.2 kV

Result of temperature-rise testTest passed

Result of tight fit on supportTest passed

Test spectrumService life test category 1...

Acceleration5g

Surface flammability NFPA 130 (ASTM E 162)passed

Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3

Height NS 35/7,547.5 mm

Height NS 35/1555 mm

Conductor cross section flexible, with ferrule without plastic sleeve max.4 mm²

2 conductors with same cross section, solid min.0.14 mm²

2 conductors with same cross section, stranded min.0.14 mm²

Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum2.5 mm²

Stripping length9 mm

Operating temperature-60 °C ... 105 °C (max. shor...

Conductor cross section flexible, with ferrule with plastic sleeve min.0.14 mm²

Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum0.14 mm²

Rated surge voltage8 kV

Maximum load current41 A (with 6 mm² conductor c...

Checking the mechanical stability of terminal points (5 x conductor connection)-

Result of surge voltage testTest passed

Bending test conductor cross section/weight0.14 mm² / 0.2 kg

Ageing test for screwless modular terminal block temperature cycles-

Test frequencyf1 = 5 Hz to f2 = 150 Hz

Shock test resultTest passed

Relative insulation material temperature index (Elec.; UL 746 B)-

Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

End cover width2.2 mm

Conductor cross section flexible min.0.14 mm²

Conductor cross section solid max.6 mm²

Tightening torque, min0.6 Nm

Ambient temperature (assembly)-5 °C ... 70 °C

ECLASS 4.127141100

ECLASS 6.027141100

ETIM 6.0EC000897

Degree of pollution3

Nominal current IN32 A (with 4 mm² conductor c...

Bending test turns135

Short circuit stability resultTest passed

Shock formHalf-sine

Specific optical density of smoke NFPA 130 (ASTM E 662)passed

Width6.2 mm

Connection methodScrew connection

Conductor cross section flexible, with ferrule without plastic sleeve min.0.14 mm²

2 conductors with same cross section, solid max.1.5 mm²

Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum0.5 mm²

Tightening torque max0.8 Nm

ECLASS 10.0.127141120

ECLASS 7.027141120

UNSPSC 12.0139121410

UNSPSC 7.090139121410

Conductor cross section short circuit testing6 mm²

Test specification, oscillation, broadband noiseDIN EN 50155 (VDE 0115-200):...

ASD level1.857 (m/s2)2/Hz

Shock protection test specificationDIN EN 50274 (VDE 0660-514):...

Result of power-frequency withstand voltage testTest passed

Result of flexion and pull-out testTest passed

Shock duration30 ms

Smoke gas toxicity NFPA 130 (SMP 800C)passed

Length47.7 mm

Conductor cross section AWG max.10

Conductor cross section flexible max.6 mm²

Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum1.5 mm²

Ambient temperature (actuation)-5 °C ... 70 °C

ECLASS 5.127141100

ETIM 2.0EC000897

UNSPSC 6.0130211811

UNSPSC 21.039121410

Ambient temperature (storage/transport)-25 °C ... 60 °C (for a shor...

ECLASS 11.027141120

ECLASS 4.027141100

ETIM 4.0EC000897

ECLASS 9.027141120

UNSPSC 13.239121410

Number of levels1

Back of the hand protectionguaranteed

Result of thermal testTest passed

Flammability rating according to UL 94V0

Colorgray

Connection in acc. with standardCSA

Test directionsX-, Y- and Z-axis (pos. and ...

Screw threadM3

UNSPSC 1139121410

Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3

UNSPSC 18.039121410

Nominal cross section4 mm²

Maximum power dissipation for nominal condition1.02 W

Open side panelYes

Insulating materialPA

Finger protectionguaranteed

Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))125 °C

UNSPSC 19.039121410

Number of connections2

Short-time current0.72 kA

Tensile test resultTest passed

Result of voltage-drop testTest passed

Tractive force setpoint-

Conductor cross section tensile test-

Requirements, voltage drop-

Oscillation, broadband noise test resultTest passed

Height46.9 mm

NoteNote: Product releases, conn...

Min. AWG conductor cross section, flexible26

Max. AWG conductor cross section, flexible10

Result of the test for mechanical stability of terminal points (5 x conductor connection)Test passed

Potentials1

Relative insulation material temperature index (Elec., UL 746 B)130 °C

Requirement temperature-rise testIncrease in temperature ≤ 45...

About the manufacturer

Phoenix Contact

Powermatic Associates is an authorized Phoenix Contact distributor, proudly offering a wide array of innovative industrial solutions that cater to modern technological demands. Phoenix Contact is a global leader renowned for its high-quality products in the fields of electrical engineering and automation technology. Their extensive catalog encompasses everything from connection technology, interface systems, and surge protection to automation software and control technology, making them a versatile choice for various industrial applications. At Powermatic Associates, we deliver Phoenix Contact’s pioneering connectivity and power management solutions, which include terminal blocks, connectors, relays, and PLCs. These components are essential for creating efficient and reliable electrical connections in diverse environments, ensuring seamless system integration. The company's comprehensive range of Industrial Internet of Things (IIoT) solutions facilitates intelligent networking, enabling customers to optimize their automation processes with cutting-edge technology. Phoenix Contact's emphasis on sustainability and innovation reflects in their energy management systems and renewable energy solutions. By incorporating these into your operations, you not only enhance efficiency but also contribute to sustainable practices, aligning with modern environmental standards. Powermatic Associates recognizes the significance of such advancements and partners with Phoenix Contact to provide expert engineering support and tailored solutions, helping you implement smart technologies that drive productivity and minimize costs. With a focus on safety and reliability, Phoenix Contact offers advanced surge protection devices and signal conditioners that safeguard your equipment against voltage spikes and ensure data integrity. In collaboration with Powermatic Associates, customers gain access to robust technical support and consultation, ensuring that every project benefits from personalized guidance and quick resolution of technical challenges. Our partnership extends the reach of Phoenix Contact’s globally recognized industrial automation products, including Human Machine Interfaces (HMIs) and Ethernet switches, empowering businesses with enhanced operational control and communication capabilities. Customers can trust Powermatic Associates to deliver prompt shipping and thorough assistance, ensuring that Phoenix Contact’s top-tier products are seamlessly integrated into their workflows for optimal performance.

Recently viewed products

Relevant products

FAQ

40 in stock

Double-level terminal block, connection method: Screw connection, cross section: 0.14 mm² - 6 mm², AWG: 26 - 10, width: 6.2 mm, color: gray, mounting type: NS 35/7,5, NS 35/15

Similar products from: Terminal Blocks

What can I help you find today?

Recommended parts