3044814 Phoenix Contact Terminal Blocks


Part#:3044814
Manufacturer:Phoenix Contact
Category:Terminal Blocks
Product Lifecycle:Active
Mar 14, 2025
Product description
Double-level terminal block, connection method: Screw connection, cross section: 0.14 mm² - 6 mm², AWG: 26 - 10, width: 6.2 mm, color: gray, mounting type: NS 35/7,5, NS 35/15
Product Details
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 5.0 27141100
- ETIM 3.0 EC000901
- ETIM 7.0 EC000897
- UNSPSC 20.0 39121410
- Test duration per axis 5 h
- Insulating material group I
- Nominal voltage UN 800 V
- Bending test rotation speed 10 rpm
- Tight fit on carrier NS 35
- Setpoint 1 N
- Proof of thermal characteristics (needle flame) effective duration 30 s
- Test specification, shock test DIN EN 50155 (VDE 0115-200):2008-03
- Number of shocks per direction 3
- Static insulating material application in cold -60 °C
- Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Conductor cross section solid min. 0.14 mm²
- Conductor cross section AWG min. 26
- Conductor cross section flexible, with ferrule with plastic sleeve max. 4 mm²
- 2 conductors with same cross section, stranded max. 1.5 mm²
- Internal cylindrical gage A4
- Permissible humidity (storage/transport) 30 % ... 70 %
- Area of application Railway industry
- Overvoltage category III
- Power frequency withstand voltage setpoint 2 kV
- Result of temperature-rise test Test passed
- Result of tight fit on support Test passed
- Test spectrum Service life test category 2, bogie-mounted
- Acceleration 30g
- Surface flammability NFPA 130 (ASTM E 162) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Height NS 35/7,5 65 mm
- Height NS 35/15 72.5 mm
- Conductor cross section flexible, with ferrule without plastic sleeve max. 4 mm²
- 2 conductors with same cross section, solid min. 0.14 mm²
- 2 conductors with same cross section, stranded min. 0.14 mm²
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum 2.5 mm²
- Stripping length 9 mm
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.14 mm²
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum 0.14 mm²
- Rated surge voltage 8 kV
- Maximum load current 36 A (with 6 mm² conductor cross section)
- Checking the mechanical stability of terminal points (5 x conductor connection) Test passed
- Result of surge voltage test Test passed
- Bending test conductor cross section/weight 0.14 mm² / 0.2 kg
- Ageing test for screwless modular terminal block temperature cycles 192
- Test frequency f1 = 5 Hz to f2 = 250 Hz
- Shock test result Test passed
- Relative insulation material temperature index (Elec.; UL 746 B) 130 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- End cover width 2.2 mm
- Conductor cross section flexible min. 0.14 mm²
- Conductor cross section solid max. 6 mm²
- Tightening torque, min 0.6 Nm
- Ambient temperature (assembly) -5 °C ... 70 °C
- ECLASS 4.1 27141100
- ECLASS 6.0 27141100
- ETIM 6.0 EC000897
- Degree of pollution 3
- Nominal current IN 30 A
- Bending test turns 135
- Short circuit stability result Test passed
- Shock form Half-sine
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Width 6.2 mm
- Connection method Screw connection
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.14 mm²
- 2 conductors with same cross section, solid max. 1.5 mm²
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum 0.5 mm²
- Tightening torque max 0.8 Nm
- ECLASS 10.0.1 27141120
- ECLASS 7.0 27141120
- UNSPSC 12.01 39121410
- UNSPSC 7.0901 39121410
- Conductor cross section short circuit testing 4 mm²
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2018-05
- ASD level 6.12 (m/s2)2/Hz
- Shock protection test specification DIN EN 50274 (VDE 0660-514):2002-11
- Result of power-frequency withstand voltage test Test passed
- Result of flexion and pull-out test Test passed
- Shock duration 18 ms
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Length 69.9 mm
- Conductor cross section AWG max. 10
- Conductor cross section flexible max. 6 mm²
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum 1.5 mm²
- Ambient temperature (actuation) -5 °C ... 70 °C
- ECLASS 5.1 27141100
- ETIM 2.0 EC000901
- UNSPSC 6.01 30211811
- UNSPSC 21.0 39121410
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- ECLASS 11.0 27141120
- ECLASS 4.0 27141100
- ETIM 4.0 EC000897
- ECLASS 9.0 27141120
- UNSPSC 13.2 39121410
- Number of levels 2
- Back of the hand protection guaranteed
- Result of thermal test Test passed
- Flammability rating according to UL 94 V0
- Color gray
- Connection in acc. with standard CSA
- Test directions X-, Y- and Z-axis (pos. and neg.)
- Screw thread M3
- UNSPSC 11 39121410
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- UNSPSC 18.0 39121410
- Nominal cross section 4 mm²
- Maximum power dissipation for nominal condition 1.02 W (the value is multiplied when connecting multiple levels)
- Open side panel Yes
- Insulating material PA
- Finger protection guaranteed
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
- UNSPSC 19.0 39121410
- Number of connections 4
- Short-time current 0.48 kA
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
3044814 Phoenix Contact
Get a quick Quote!
Request a quote, and we will send you price within minutes.
Stock:
Select Qty:
Average response time: 11 minutes
Worldwide Shipping and Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare 3044814 with other products
China RoHS
ECLASS 5.0
ETIM 3.0
ETIM 7.0
UNSPSC 20.0
Test duration per axis
Insulating material group
Nominal voltage UN
Bending test rotation spe...
Tight fit on carrier
Setpoint
Proof of thermal characte...
Test specification, shock...
Number of shocks per dire...
Static insulating materia...
Calorimetric heat release...
Fire protection for rail ...
Conductor cross section s...
Conductor cross section A...
Conductor cross section f...
2 conductors with same cr...
Internal cylindrical gage
Permissible humidity (sto...
Area of application
Overvoltage category
Power frequency withstand...
Result of temperature-ris...
Result of tight fit on su...
Test spectrum
Acceleration
Surface flammability NFPA...
Fire protection for rail ...
Height NS 35/7,5
Height NS 35/15
Conductor cross section f...
2 conductors with same cr...
2 conductors with same cr...
Two conductors with the s...
Stripping length
Operating temperature
Conductor cross section f...
Two conductors with the s...
Rated surge voltage
Maximum load current
Checking the mechanical s...
Result of surge voltage t...
Bending test conductor cr...
Ageing test for screwless...
Test frequency
Shock test result
Relative insulation mater...
Fire protection for rail ...
End cover width
Conductor cross section f...
Conductor cross section s...
Tightening torque, min
Ambient temperature (asse...
ECLASS 4.1
ECLASS 6.0
ETIM 6.0
Degree of pollution
Nominal current IN
Bending test turns
Short circuit stability r...
Shock form
Specific optical density ...
Width
Connection method
Conductor cross section f...
2 conductors with same cr...
Two conductors with the s...
Tightening torque max
ECLASS 10.0.1
ECLASS 7.0
UNSPSC 12.01
UNSPSC 7.0901
Conductor cross section s...
Test specification, oscil...
ASD level
Shock protection test spe...
Result of power-frequency...
Result of flexion and pul...
Shock duration
Smoke gas toxicity NFPA 1...
Length
Conductor cross section A...
Conductor cross section f...
Two conductors with the s...
Ambient temperature (actu...
ECLASS 5.1
ETIM 2.0
UNSPSC 6.01
UNSPSC 21.0
Ambient temperature (stor...
ECLASS 11.0
ECLASS 4.0
ETIM 4.0
ECLASS 9.0
UNSPSC 13.2
Number of levels
Back of the hand protecti...
Result of thermal test
Flammability rating accor...
Color
Connection in acc. with s...
Test directions
Screw thread
UNSPSC 11
Fire protection for rail ...
UNSPSC 18.0
Nominal cross section
Maximum power dissipation...
Open side panel
Insulating material
Finger protection
Temperature index of insu...
UNSPSC 19.0
Number of connections
Short-time current
Tensile test result
Result of voltage-drop te...
Tractive force setpoint
Conductor cross section t...
Requirements, voltage dro...
Oscillation, broadband no...
Height
Note
Min. AWG conductor cross ...
Max. AWG conductor cross ...
Result of the test for me...
Potentials
Relative insulation mater...
Requirement temperature-r...
Selected product

3044814
Phoenix Contact
Double-level terminal block, connection method: Screw connection, cross section: 0.14 mm² - 6 mm², A...
China RoHSEnvironmentally Friendly Use...
ECLASS 5.027141100
ETIM 3.0EC000901
ETIM 7.0EC000897
UNSPSC 20.039121410
Test duration per axis5 h
Insulating material groupI
Nominal voltage UN800 V
Bending test rotation speed10 rpm
Tight fit on carrierNS 35
Setpoint1 N
Proof of thermal characteristics (needle flame) effective duration30 s
Test specification, shock testDIN EN 50155 (VDE 0115-200):...
Number of shocks per direction3
Static insulating material application in cold-60 °C
Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Conductor cross section solid min.0.14 mm²
Conductor cross section AWG min.26
Conductor cross section flexible, with ferrule with plastic sleeve max.4 mm²
2 conductors with same cross section, stranded max.1.5 mm²
Internal cylindrical gageA4
Permissible humidity (storage/transport)30 % ... 70 %
Area of applicationRailway industry
Overvoltage categoryIII
Power frequency withstand voltage setpoint2 kV
Result of temperature-rise testTest passed
Result of tight fit on supportTest passed
Test spectrumService life test category 2...
Acceleration30g
Surface flammability NFPA 130 (ASTM E 162)passed
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Height NS 35/7,565 mm
Height NS 35/1572.5 mm
Conductor cross section flexible, with ferrule without plastic sleeve max.4 mm²
2 conductors with same cross section, solid min.0.14 mm²
2 conductors with same cross section, stranded min.0.14 mm²
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum2.5 mm²
Stripping length9 mm
Operating temperature-60 °C ... 105 °C (max. shor...
Conductor cross section flexible, with ferrule with plastic sleeve min.0.14 mm²
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum0.14 mm²
Rated surge voltage8 kV
Maximum load current36 A (with 6 mm² conductor c...
Checking the mechanical stability of terminal points (5 x conductor connection)Test passed
Result of surge voltage testTest passed
Bending test conductor cross section/weight0.14 mm² / 0.2 kg
Ageing test for screwless modular terminal block temperature cycles192
Test frequencyf1 = 5 Hz to f2 = 250 Hz
Shock test resultTest passed
Relative insulation material temperature index (Elec.; UL 746 B)130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3
End cover width2.2 mm
Conductor cross section flexible min.0.14 mm²
Conductor cross section solid max.6 mm²
Tightening torque, min0.6 Nm
Ambient temperature (assembly)-5 °C ... 70 °C
ECLASS 4.127141100
ECLASS 6.027141100
ETIM 6.0EC000897
Degree of pollution3
Nominal current IN30 A
Bending test turns135
Short circuit stability resultTest passed
Shock formHalf-sine
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Width6.2 mm
Connection methodScrew connection
Conductor cross section flexible, with ferrule without plastic sleeve min.0.14 mm²
2 conductors with same cross section, solid max.1.5 mm²
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum0.5 mm²
Tightening torque max0.8 Nm
ECLASS 10.0.127141120
ECLASS 7.027141120
UNSPSC 12.0139121410
UNSPSC 7.090139121410
Conductor cross section short circuit testing4 mm²
Test specification, oscillation, broadband noiseDIN EN 50155 (VDE 0115-200):...
ASD level6.12 (m/s2)2/Hz
Shock protection test specificationDIN EN 50274 (VDE 0660-514):...
Result of power-frequency withstand voltage testTest passed
Result of flexion and pull-out testTest passed
Shock duration18 ms
Smoke gas toxicity NFPA 130 (SMP 800C)passed
Length69.9 mm
Conductor cross section AWG max.10
Conductor cross section flexible max.6 mm²
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum1.5 mm²
Ambient temperature (actuation)-5 °C ... 70 °C
ECLASS 5.127141100
ETIM 2.0EC000901
UNSPSC 6.0130211811
UNSPSC 21.039121410
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a shor...
ECLASS 11.027141120
ECLASS 4.027141100
ETIM 4.0EC000897
ECLASS 9.027141120
UNSPSC 13.239121410
Number of levels2
Back of the hand protectionguaranteed
Result of thermal testTest passed
Flammability rating according to UL 94V0
Colorgray
Connection in acc. with standardCSA
Test directionsX-, Y- and Z-axis (pos. and ...
Screw threadM3
UNSPSC 1139121410
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
UNSPSC 18.039121410
Nominal cross section4 mm²
Maximum power dissipation for nominal condition1.02 W (the value is multipl...
Open side panelYes
Insulating materialPA
Finger protectionguaranteed
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C
UNSPSC 19.039121410
Number of connections4
Short-time current0.48 kA
Tensile test result-
Result of voltage-drop test-
Tractive force setpoint-
Conductor cross section tensile test-
Requirements, voltage drop-
Oscillation, broadband noise test result-
Height-
Note-
Min. AWG conductor cross section, flexible-
Max. AWG conductor cross section, flexible-
Result of the test for mechanical stability of terminal points (5 x conductor connection)-
Potentials-
Relative insulation material temperature index (Elec., UL 746 B)-
Requirement temperature-rise test-
About the manufacturer

Powermatic Associates is an authorized Phoenix Contact distributor, proudly offering a wide array of innovative industrial solutions that cater to modern technological demands. Phoenix Contact is a global leader renowned for its high-quality products in the fields of electrical engineering and automation technology. Their extensive catalog encompasses everything from connection technology, interface systems, and surge protection to automation software and control technology, making them a versatile choice for various industrial applications. At Powermatic Associates, we deliver Phoenix Contact’s pioneering connectivity and power management solutions, which include terminal blocks, connectors, relays, and PLCs. These components are essential for creating efficient and reliable electrical connections in diverse environments, ensuring seamless system integration. The company's comprehensive range of Industrial Internet of Things (IIoT) solutions facilitates intelligent networking, enabling customers to optimize their automation processes with cutting-edge technology. Phoenix Contact's emphasis on sustainability and innovation reflects in their energy management systems and renewable energy solutions. By incorporating these into your operations, you not only enhance efficiency but also contribute to sustainable practices, aligning with modern environmental standards. Powermatic Associates recognizes the significance of such advancements and partners with Phoenix Contact to provide expert engineering support and tailored solutions, helping you implement smart technologies that drive productivity and minimize costs. With a focus on safety and reliability, Phoenix Contact offers advanced surge protection devices and signal conditioners that safeguard your equipment against voltage spikes and ensure data integrity. In collaboration with Powermatic Associates, customers gain access to robust technical support and consultation, ensuring that every project benefits from personalized guidance and quick resolution of technical challenges. Our partnership extends the reach of Phoenix Contact’s globally recognized industrial automation products, including Human Machine Interfaces (HMIs) and Ethernet switches, empowering businesses with enhanced operational control and communication capabilities. Customers can trust Powermatic Associates to deliver prompt shipping and thorough assistance, ensuring that Phoenix Contact’s top-tier products are seamlessly integrated into their workflows for optimal performance.
Recently viewed products
Relevant products
FAQ
40 in stock
Double-level terminal block, connection method: Screw connection, cross section: 0.14 mm² - 6 mm², AWG: 26 - 10, width: 6.2 mm, color: gray, mounting type: NS 35/7,5, NS 35/15
Similar products from: Terminal Blocks
What can I help you find today?