Product description

Schneider Electric LP1K09008BD is a magnetic contactor within the K sub-range, featuring screw connections and a 4-pole (4P; 2NO+2NC) configuration. It has a rated current of 20A (AC-1) and 110A (Irms AC), with a net width of 45 mm. This contactor offers a degree of protection of IP20 and operates with a control voltage (DC) range of 19.2-27.6Vdc (24Vdc nominal; 0.8...1.15 x Uc). The rated operating voltage (Ue) is 690 V, and it is designed without normally open (NO) or normally closed (NC) auxiliary contacts. Its mechanical durability is rated at 10,000,000 operations at no load, and it supports a rated voltage (AC) phase-to-phase of 690 V.

Product Details

  • Operating Time
    30...40 ms coil energisation and NO closing 10 ms coil de-energisation and NO opening 25...35 ms coil energisation and NC opening 15 ms coil de-energisation and NC closing
  • [Ui] Rated Insulation Voltage
    Power circuit 600 V UL 508 Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA C22.2 No 14
  • Flame Retardance
    V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
  • Rated Breaking Capacity
    110 A 415 V IEC 60947 110 A 440 V IEC 60947 80 A 500 V IEC 60947 110 A 220...230 V IEC 60947 110 A 380...400 V IEC 60947 70 A 660...690 V IEC 60947
  • Mounting Support
    Rail Plate
  • Tightening Torque
    11.51 lbf.in (1.3 N.m) screw clamp terminals Philips No 2 11.51 lbf.in (1.3 N.m) screw clamp terminals flat Ø 6 mm
  • Irms Rated Making Capacity
    110 A AC power circuit NF C 63-110 110 A AC power circuit IEC 60947
  • Associated Fuse Rating
    25 A gG <= 440 V power circuit 25 A aM power circuit
  • Control Circuit Voltage Limits
    Operational: 0.8...1.15 Uc (at <50 °C) Drop-out 0.1...0.75 Uc 122 °F (50 °C))
  • [Ie] Rated Operational Current
    20 A 122 °F (50 °C)) <= 440 V AC AC-1 power circuit 16 A 158 °F (70 °C)) 690 V AC AC-1 power circuit
  • Safety Reliability Level
    B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • Height
    2.28 in (58 mm)
  • Depth
    2.24 in (57 mm)
  • Maximum Operating Rate
    3600 cyc/h
  • Net Weight
    0.50 lb(US) (0.225 kg)
  • Width
    1.77 in (45 mm)
  • Hold-In Power Consumption In W
    3 W 68 °F (20 °C)
  • Mechanical Durability
    10 Mcycles
  • Inrush Power In W
    3 W 68 °F (20 °C))
  • Average Impedance
    3 mOhm - Ith 20 A 50 Hz power circuit
  • [Ith] Conventional Free Air Thermal Current
    20 A 122 °F (50 °C) power circuit
  • [Ue] Rated Operational Voltage
    Power circuit 690 V AC 50/60 Hz
  • [Uimp] Rated Impulse Withstand Voltage
    8 kV
  • Overvoltage Category
    III
  • Pole Contact Composition
    2 NO + 2 NC
  • Contactor Application
    Resistive load
  • Poles Description
    4P
  • Utilisation Category
    AC-1
  • Range Of Product
    TeSys K
  • Range
    TeSys
  • Device Short Name
    LP1K
  • Product Or Component Type
    Contactor

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of LP1K09008BD on Powermatic Associates is $97.42. Order now.



Manufacturer warranty

LP1K09008BD Schneider Electric

$97.42

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$97.42

$97.42 each

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare LP1K09008BD with other products

Operating Time

[Ui] Rated Insulation Voltage

Flame Retardance

Rated Breaking Capacity

Mounting Support

Tightening Torque

Irms Rated Making Capacity

Associated Fuse Rating

Control Circuit Voltage Limits

[Ie] Rated Operational Current

Safety Reliability Level

Height

Depth

Maximum Operating Rate

Net Weight

Width

Hold-In Power Consumption In W

Mechanical Durability

Inrush Power In W

Average Impedance

[Ith] Conventional Free Air Thermal Current

[Ue] Rated Operational Voltage

[Uimp] Rated Impulse Withstand Voltage

Overvoltage Category

Pole Contact Composition

Contactor Application

Poles Description

Utilisation Category

Range Of Product

Range

Device Short Name

Product Or Component Type

Product Certifications

[Icw] Rated Short-Time Withstand Current

[Ui] Rated Insulation Voltage

Tightening Torque

Associated Fuse Rating

Control Circuit Voltage Limits

Irms Rated Making Capacity

Connections - Terminals

Standards

Auxiliary Contacts Type

Non-Overlap Time

Safety Reliability Level

Operating Time

[Ith] Conventional Free Air Thermal Current

[Ue] Rated Operational Voltage

Mounting Support

Minimum Switching Voltage

Hold-In Power Consumption In W

Insulation Resistance

Minimum Switching Current

Signalling Circuit Frequency

Maximum Operating Rate

Mechanical Durability

Time Constant

Inrush Power In W

Coil Technology

Front Cover

Power Dissipation Per Pole

Average Impedance

Rated Breaking Capacity

Overvoltage Category

[Uc] Control Circuit Voltage

[Uimp] Rated Impulse Withstand Voltage

Auxiliary Contact Composition

Control Circuit Type

[Ie] Rated Operational Current

Poles Description

Product Or Component Type

Utilisation Category

Power Pole Contact Composition

Device Short Name

Product Name

Range

Contactor Application

Product Certifications

[Icw] Rated Short-Time Withstand Current

[Ui] Rated Insulation Voltage

Tightening Torque

Standards

Associated Fuse Rating

Control Circuit Voltage Limits

Irms Rated Making Capacity

Operating Time

Safety Reliability Level

Non-Overlap Time

[Ue] Rated Operational Voltage

[Ith] Conventional Free Air Thermal Current

Mounting Support

Auxiliary Contacts Type

Connections - Terminals

Insulation Resistance

Signalling Circuit Frequency

Minimum Switching Current

Hold-In Power Consumption In W

Time Constant

Maximum Operating Rate

Minimum Switching Voltage

Coil Technology

Inrush Power In W

Mechanical Durability

Front Cover

Power Dissipation Per Pole

Rated Breaking Capacity

Average Impedance

Auxiliary Contact Composition

Overvoltage Category

[Uimp] Rated Impulse Withstand Voltage

[Uc] Control Circuit Voltage

Control Circuit Type

[Ie] Rated Operational Current

Power Pole Contact Composition

Utilisation Category

Product Or Component Type

Contactor Application

Range

Device Short Name

Product Name

Poles Description

Selected product

LP1K09008BD
0 in stock
LP1K09008BD
Schneider Electric

Schneider Electric LP1K09008BD is a magnetic contactor within the K sub-range, featuring screw conne...

Operating Time30...40 ms coil energisation and NO closing 10 ms coil de-energisation and NO opening 25...35 ms coil energisation and NC opening 15 ms coil de-energisation and NC closing

[Ui] Rated Insulation VoltagePower circuit 600 V UL 508 Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA C22.2 No 14

Flame RetardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102

Rated Breaking Capacity110 A 415 V IEC 60947 110 A 440 V IEC 60947 80 A 500 V IEC 60947 110 A 220...230 V IEC 60947 110 A 380...400 V IEC 60947 70 A 660...690 V IEC 60947

Mounting SupportRail Plate

Tightening Torque11.51 lbf.in (1.3 N.m) screw clamp terminals Philips No 2 11.51 lbf.in (1.3 N.m) screw clamp terminals flat Ø 6 mm

Irms Rated Making Capacity110 A AC power circuit NF C 63-110 110 A AC power circuit IEC 60947

Associated Fuse Rating25 A gG <= 440 V power circuit 25 A aM power circuit

Control Circuit Voltage LimitsOperational: 0.8...1.15 Uc (at <50 °C) Drop-out 0.1...0.75 Uc 122 °F (50 °C))

[Ie] Rated Operational Current20 A 122 °F (50 °C)) <= 440 V AC AC-1 power circuit 16 A 158 °F (70 °C)) 690 V AC AC-1 power circuit

Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1

Height2.28 in (58 mm)

Depth2.24 in (57 mm)

Maximum Operating Rate3600 cyc/h

Net Weight0.50 lb(US) (0.225 kg)

Width1.77 in (45 mm)

Hold-In Power Consumption In W3 W 68 °F (20 °C)

Mechanical Durability10 Mcycles

Inrush Power In W3 W 68 °F (20 °C))

Average Impedance3 mOhm - Ith 20 A 50 Hz power circuit

[Ith] Conventional Free Air Thermal Current20 A 122 °F (50 °C) power circuit

[Ue] Rated Operational VoltagePower circuit 690 V AC 50/60 Hz

[Uimp] Rated Impulse Withstand Voltage8 kV

Overvoltage CategoryIII

Pole Contact Composition2 NO + 2 NC

Contactor ApplicationResistive load

Poles Description4P

Utilisation CategoryAC-1

Range Of ProductTeSys K

RangeTeSys

Device Short NameLP1K

Product Or Component TypeContactor

Product Certifications-

[Icw] Rated Short-Time Withstand Current-

[Ui] Rated Insulation Voltage-

Tightening Torque-

Associated Fuse Rating-

Control Circuit Voltage Limits-

Irms Rated Making Capacity-

Connections - Terminals-

Standards-

Auxiliary Contacts Type-

Non-Overlap Time-

Safety Reliability Level-

Operating Time-

[Ith] Conventional Free Air Thermal Current-

[Ue] Rated Operational Voltage-

Mounting Support-

Minimum Switching Voltage-

Hold-In Power Consumption In W-

Insulation Resistance-

Minimum Switching Current-

Signalling Circuit Frequency-

Maximum Operating Rate-

Mechanical Durability-

Time Constant-

Inrush Power In W-

Coil Technology-

Front Cover-

Power Dissipation Per Pole-

Average Impedance-

Rated Breaking Capacity-

Overvoltage Category-

[Uc] Control Circuit Voltage-

[Uimp] Rated Impulse Withstand Voltage-

Auxiliary Contact Composition-

Control Circuit Type-

[Ie] Rated Operational Current-

Poles Description-

Product Or Component Type-

Utilisation Category-

Power Pole Contact Composition-

Device Short Name-

Product Name-

Range-

Contactor Application-

Product Certifications-

[Icw] Rated Short-Time Withstand Current-

[Ui] Rated Insulation Voltage-

Tightening Torque-

Standards-

Associated Fuse Rating-

Control Circuit Voltage Limits-

Irms Rated Making Capacity-

Operating Time-

Safety Reliability Level-

Non-Overlap Time-

[Ue] Rated Operational Voltage-

[Ith] Conventional Free Air Thermal Current-

Mounting Support-

Auxiliary Contacts Type-

Connections - Terminals-

Insulation Resistance-

Signalling Circuit Frequency-

Minimum Switching Current-

Hold-In Power Consumption In W-

Time Constant-

Maximum Operating Rate-

Minimum Switching Voltage-

Coil Technology-

Inrush Power In W-

Mechanical Durability-

Front Cover-

Power Dissipation Per Pole-

Rated Breaking Capacity-

Average Impedance-

Auxiliary Contact Composition-

Overvoltage Category-

[Uimp] Rated Impulse Withstand Voltage-

[Uc] Control Circuit Voltage-

Control Circuit Type-

[Ie] Rated Operational Current-

Power Pole Contact Composition-

Utilisation Category-

Product Or Component Type-

Contactor Application-

Range-

Device Short Name-

Product Name-

Poles Description-

LC1DT20BL
2 in stock
LC1DT20BL
Schneider Electric

Schneider Electric LC1DT20BL is a magnetic contactor from the Deca sub-range, designed with a low-co...

Operating Time-

[Ui] Rated Insulation Voltage-

Flame Retardance-

Rated Breaking Capacity-

Mounting Support-

Tightening Torque-

Irms Rated Making Capacity-

Associated Fuse Rating-

Control Circuit Voltage Limits-

[Ie] Rated Operational Current-

Safety Reliability Level-

Height-

Depth-

Maximum Operating Rate-

Net Weight-

Width-

Hold-In Power Consumption In W-

Mechanical Durability-

Inrush Power In W-

Average Impedance-

[Ith] Conventional Free Air Thermal Current-

[Ue] Rated Operational Voltage-

[Uimp] Rated Impulse Withstand Voltage-

Overvoltage Category-

Pole Contact Composition-

Contactor Application-

Poles Description-

Utilisation Category-

Range Of Product-

Range-

Device Short Name-

Product Or Component Type-

Product CertificationsBV CSA GOST GL CCC UL DNV LROS (Lloyds register of shipping) RINA

[Icw] Rated Short-Time Withstand Current30 A 104 °F (40 °C) - 10 min power circuit 61 A 104 °F (40 °C) - 1 min power circuit 105 A 104 °F (40 °C) - 10 s power circuit 210 A 104 °F (40 °C) - 1 s power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circu

[Ui] Rated Insulation VoltagePower circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL Power circuit 690 V IEC 60947-4-1

Tightening TorqueControl circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Power circuit 15.05 lb

Associated Fuse Rating10 A gG signalling circuit IEC 60947-5-1 25 A gG <= 690 V type 1 power circuit 20 A gG <= 690 V type 2 power circuit

Control Circuit Voltage Limits0.1...0.3 Uc -40…158 °F (-40…70 °C) drop-out DC 0.8...1.25 Uc -40…140 °F (-40…60 °C) operational DC 1...1.25 Uc 140…158 °F (60…70 °C) operational DC

Irms Rated Making Capacity140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 250 A 440 V power circuit IEC 60947

Connections - TerminalsControl circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)fle

StandardsCSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508

Auxiliary Contacts TypeMechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1

Non-Overlap Time1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact

Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1

Operating Time65.45...88.55 ms closing 20...30 ms opening

[Ith] Conventional Free Air Thermal Current10 A 140 °F (60 °C) signalling circuit 20 A 140 °F (60 °C) power circuit

[Ue] Rated Operational VoltagePower circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC

Mounting SupportRail Plate

Minimum Switching Voltage17 V signalling circuit

Hold-In Power Consumption In W2.4 W 68 °F (20 °C)

Insulation Resistance> 10 MOhm signalling circuit

Minimum Switching Current5 mA signalling circuit

Signalling Circuit Frequency25...400 Hz

Maximum Operating Rate3600 cyc/h 140 °F (60 °C)

Mechanical Durability30 Mcycles

Time Constant40 ms

Inrush Power In W2.4 W 68 °F (20 °C))

Coil TechnologyBuilt-in bidirectional peak limiting diode suppressor

Front CoverWith

Power Dissipation Per Pole1.56 W AC-1

Average Impedance2.5 mOhm - Ith 20 A 50 Hz power circuit

Rated Breaking Capacity250 A 440 V power circuit IEC 60947

Overvoltage CategoryIII

[Uc] Control Circuit Voltage24 V DC

[Uimp] Rated Impulse Withstand Voltage6 kV IEC 60947

Auxiliary Contact Composition1 NO + 1 NC

Control Circuit TypeDC low consumption

[Ie] Rated Operational Current20 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit

Poles Description4P

Product Or Component TypeContactor

Utilisation CategoryAC-1

Power Pole Contact Composition4 NO

Device Short NameLC1D

Product NameTeSys D

RangeTeSys

Contactor ApplicationResistive load

Product Certifications-

[Icw] Rated Short-Time Withstand Current-

[Ui] Rated Insulation Voltage-

Tightening Torque-

Standards-

Associated Fuse Rating-

Control Circuit Voltage Limits-

Irms Rated Making Capacity-

Operating Time-

Safety Reliability Level-

Non-Overlap Time-

[Ue] Rated Operational Voltage-

[Ith] Conventional Free Air Thermal Current-

Mounting Support-

Auxiliary Contacts Type-

Connections - Terminals-

Insulation Resistance-

Signalling Circuit Frequency-

Minimum Switching Current-

Hold-In Power Consumption In W-

Time Constant-

Maximum Operating Rate-

Minimum Switching Voltage-

Coil Technology-

Inrush Power In W-

Mechanical Durability-

Front Cover-

Power Dissipation Per Pole-

Rated Breaking Capacity-

Average Impedance-

Auxiliary Contact Composition-

Overvoltage Category-

[Uimp] Rated Impulse Withstand Voltage-

[Uc] Control Circuit Voltage-

Control Circuit Type-

[Ie] Rated Operational Current-

Power Pole Contact Composition-

Utilisation Category-

Product Or Component Type-

Contactor Application-

Range-

Device Short Name-

Product Name-

Poles Description-

LC1DT206BL
3 in stock
LC1DT206BL
Schneider Electric

Schneider Electric LC1DT206BL is a magnetic contactor from the Deca sub-range, designed with a low-c...

Operating Time-

[Ui] Rated Insulation Voltage-

Flame Retardance-

Rated Breaking Capacity-

Mounting Support-

Tightening Torque-

Irms Rated Making Capacity-

Associated Fuse Rating-

Control Circuit Voltage Limits-

[Ie] Rated Operational Current-

Safety Reliability Level-

Height-

Depth-

Maximum Operating Rate-

Net Weight-

Width-

Hold-In Power Consumption In W-

Mechanical Durability-

Inrush Power In W-

Average Impedance-

[Ith] Conventional Free Air Thermal Current-

[Ue] Rated Operational Voltage-

[Uimp] Rated Impulse Withstand Voltage-

Overvoltage Category-

Pole Contact Composition-

Contactor Application-

Poles Description-

Utilisation Category-

Range Of Product-

Range-

Device Short Name-

Product Or Component Type-

Product Certifications-

[Icw] Rated Short-Time Withstand Current-

[Ui] Rated Insulation Voltage-

Tightening Torque-

Associated Fuse Rating-

Control Circuit Voltage Limits-

Irms Rated Making Capacity-

Connections - Terminals-

Standards-

Auxiliary Contacts Type-

Non-Overlap Time-

Safety Reliability Level-

Operating Time-

[Ith] Conventional Free Air Thermal Current-

[Ue] Rated Operational Voltage-

Mounting Support-

Minimum Switching Voltage-

Hold-In Power Consumption In W-

Insulation Resistance-

Minimum Switching Current-

Signalling Circuit Frequency-

Maximum Operating Rate-

Mechanical Durability-

Time Constant-

Inrush Power In W-

Coil Technology-

Front Cover-

Power Dissipation Per Pole-

Average Impedance-

Rated Breaking Capacity-

Overvoltage Category-

[Uc] Control Circuit Voltage-

[Uimp] Rated Impulse Withstand Voltage-

Auxiliary Contact Composition-

Control Circuit Type-

[Ie] Rated Operational Current-

Poles Description-

Product Or Component Type-

Utilisation Category-

Power Pole Contact Composition-

Device Short Name-

Product Name-

Range-

Contactor Application-

Product CertificationsUL GOST CSA RINA CCC BV LROS (Lloyds register of shipping) DNV GL

[Icw] Rated Short-Time Withstand Current30 A 104 °F (40 °C) - 10 min power circuit 61 A 104 °F (40 °C) - 1 min power circuit 105 A 104 °F (40 °C) - 10 s power circuit 210 A 104 °F (40 °C) - 1 s power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circu

[Ui] Rated Insulation VoltagePower circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL Power circuit 690 V IEC 60947-4-1

Tightening TorqueControl circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ø 6 mm M3.5 Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals Philips No 2 M3.5 Power circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ø 6 mm M3.5 Power circuit

StandardsCSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508

Associated Fuse Rating10 A gG signalling circuit IEC 60947-5-1 25 A gG <= 690 V type 1 power circuit 20 A gG <= 690 V type 2 power circuit

Control Circuit Voltage Limits0.1...0.3 Uc -40…158 °F (-40…70 °C) drop-out DC 0.8...1.25 Uc -40…140 °F (-40…60 °C) operational DC 1...1.25 Uc 140…158 °F (60…70 °C) operational DC

Irms Rated Making Capacity140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 250 A 440 V power circuit IEC 60947

Operating Time65.45...88.55 ms closing 20...30 ms opening

Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1

Non-Overlap Time1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact

[Ue] Rated Operational VoltagePower circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC

[Ith] Conventional Free Air Thermal Current10 A 140 °F (60 °C) signalling circuit 20 A 140 °F (60 °C) power circuit

Mounting SupportRail Plate

Auxiliary Contacts TypeMechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1

Connections - TerminalsControl circuit lugs-ring terminals 0.31 in (8 mm)) Power circuit lugs-ring terminals 0.31 in (8 mm))

Insulation Resistance> 10 MOhm signalling circuit

Signalling Circuit Frequency25...400 Hz

Minimum Switching Current5 mA signalling circuit

Hold-In Power Consumption In W2.4 W 68 °F (20 °C)

Time Constant40 ms

Maximum Operating Rate3600 cyc/h 140 °F (60 °C)

Minimum Switching Voltage17 V signalling circuit

Coil TechnologyBuilt-in bidirectional peak limiting diode suppressor

Inrush Power In W2.4 W 68 °F (20 °C))

Mechanical Durability30 Mcycles

Front CoverWith

Power Dissipation Per Pole1.56 W AC-1

Rated Breaking Capacity250 A 440 V power circuit IEC 60947

Average Impedance2.5 mOhm - Ith 20 A 50 Hz power circuit

Auxiliary Contact Composition1 NO + 1 NC

Overvoltage CategoryIII

[Uimp] Rated Impulse Withstand Voltage6 kV IEC 60947

[Uc] Control Circuit Voltage24 V DC

Control Circuit TypeDC low consumption

[Ie] Rated Operational Current20 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit

Power Pole Contact Composition4 NO

Utilisation CategoryAC-1

Product Or Component TypeContactor

Contactor ApplicationResistive load

RangeTeSys

Device Short NameLC1D

Product NameTeSys D

Poles Description4P

About the manufacturer

Schneider Electric

Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. Their extensive product line includes advanced electrical distribution equipment, smart grid solutions, building automation systems, and renewable energy technologies, all designed to enhance operational performance while minimizing environmental impact. Schneider Electric's comprehensive range of products includes circuit breakers, motor starters, contactors, relays, and variable speed drives, which are essential for ensuring safety and reliability in electrical installations. Furthermore, their sophisticated software platforms enable real-time monitoring and management of energy consumption, optimizing processes and reducing costs. Their innovative EcoStruxure architecture leverages IoT technology to deliver seamless connectivity, predictive analytics, and actionable insights, empowering businesses to make informed decisions and achieve greater operational agility. At Powermatic Associates, we recognize the transformative power of Schneider Electric's offerings and are committed to delivering these state-of-the-art solutions to our customers. Through this partnership, we provide unparalleled access to high-quality components that enhance system integration, improve energy efficiency, and bolster resilience. Our expert engineering support and tailored automation solutions ensure that your projects benefit from the latest advancements in technology. Whether you're looking for robust power distribution units or intelligent control systems, our collaboration with Schneider Electric guarantees that you receive superior products backed by industry-leading technical support. By choosing Powermatic Associates as your trusted distributor, you gain access to Schneider Electric’s innovative solutions and our value-added services, which together streamline procurement, optimize operations, and drive sustainable growth. Our expertise in motion, controls, pneumatics, and electrical solutions, combined with Schneider Electric's pioneering technologies, ensures that we remain at the forefront of delivering reliable and efficient solutions to meet your operational challenges. As partners, we are dedicated to helping you harness the power of technology to achieve peak performance and enhanced profitability in your business endeavors.

Recently viewed products

Relevant products

FAQ

What is the price of LP1K09008BD?
The price of LP1K09008BD on Powermatic Associates is $97.42. Order now.

Out if stock but available for backorder.

Schneider Electric LP1K09008BD is a magnetic contactor within the K sub-range, featuring screw connections and a 4-pole (4P; 2NO+2NC) configuration. It has a rated current of 20A (AC-1) and 110A (Irms AC), with a net width of 45 mm. This contactor offers a degree of protection of IP20 and operates with a control voltage (DC) range of 19.2-27.6Vdc (24Vdc nominal; 0.8...1.15 x Uc). The rated operating voltage (Ue) is 690 V, and it is designed without normally open (NO) or normally closed (NC) auxiliary contacts. Its mechanical durability is rated at 10,000,000 operations at no load, and it supports a rated voltage (AC) phase-to-phase of 690 V.

Similar products from: Industrial Automation Components

What can I help you find today?

Recommended parts