LC1D95M7 Schneider Electric Industrial Automation Components
Part#:LC1D95M7
Manufacturer:Schneider Electric
Product Lifecycle:Active
In-stock parts: 17
Nov 16, 2024
IEC contactor, TeSys Deca, nonreversing, 95A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO, 220VAC 50/60Hz coil, open style
About the manufacturer: Schneider Electric is one of the manufacturers that offers Industrial Automation Components that you can order at Powermatic Associates site. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.
Check out the LC1D95M7 Schneider Electric price in the box on the right side or send a quick quote.
Product Details
- Product Certifications IECEE CB Scheme UL CSA CCC EAC LROS (Lloyds register of shipping) RINA BV DNV-GL
- [Icw] Rated Short-Time Withstand Current 1100 A 104 °F (40 °C) - 1 s power circuit 800 A 104 °F (40 °C) - 10 s power circuit 400 A 104 °F (40 °C) - 1 min power circuit 135 A 104 °F (40 °C) - 10 min power circuit 140 A - 100 ms signalling circuit 120 A - 500 ms signalling
- [Ui] Rated Insulation Voltage Power circuit 1000 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL
- Motor Power HP (UL / CSA) 7.5 hp 115 V at AC 60 Hz for 1 phase 15 hp 230/240 V at AC 60 Hz for 1 phase 25 hp 200/208 V at AC 60 Hz for 3 phase 30 hp 230/240 V at AC 60 Hz for 3 phase 60 hp 460/480 V at AC 60 Hz for 3 phase 60 hp 575/600 V at AC 60 Hz for 3
- Motor Power Kw 25 kW 220...230 V AC 50 Hz AC-3) 45 kW 380...400 V AC 50 Hz AC-3) 45 kW 415...440 V AC 50 Hz AC-3) 55 kW 500 V AC 50 Hz AC-3) 45 kW 660...690 V AC 50 Hz AC-3) 45 kW 1000 V AC 50 Hz AC-3)
- Control Circuit Voltage Limits 0.8...1.1 Uc -40…131 °F (-40…55 °C) operational AC 50 Hz 0.85...1.1 Uc -40…131 °F (-40…55 °C) operational AC 60 Hz 0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz 1...1.1 Uc 131…158 °F (55…70 °C) operational AC 50/60 Hz
- Standards EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4
- Tightening Torque Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals Philips No 2 Power circuit 106.21 lbf.in (12 N.m) connector flat Ø 6 to Ø 8 mm Power circuit 106.21 lbf.in
- Connections - Terminals Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flex
- Associated Fuse Rating 10 A gG signalling circuit IEC 60947-5-1 200 A gG <= 690 V type 1 power circuit 160 A gG <= 690 V type 2 power circuit
- Irms Rated Making Capacity 1100 A 440 V AC power circuit IEC 60947 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1
- Utilisation Category AC-1 AC-4 AC-3
- Inrush Power In VA 245 VA 60 Hz 0.75 68 °F (20 °C)) 245 VA 50 Hz 0.75 68 °F (20 °C))
- Non-Overlap Time 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
- Contactor Application Motor control Resistive load
- Electrical Durability 1.2 Mcycles 95 A AC-3 1.3 Mcycles 125 A AC-1
- [Ith] Conventional Free Air Thermal Current 10 A 140 °F (60 °C) signalling circuit 125 A 140 °F (60 °C) power circuit
- Operating Time 20...35 ms closing 6...20 ms opening
- Hold-In Power Consumption In VA 26 VA 60 Hz 0.3 68 °F (20 °C)) 26 VA 50 Hz 0.3 68 °F (20 °C))
- Safety Reliability Level B10d = 1.3 Mcycles contactor with nominal load EN/ISO 13849-1 B10d = 20 Mcycles contactor with mechanical load EN/ISO 13849-1
- Power Dissipation Per Pole 12.5 W AC-1 7.2 W AC-3
- Mounting Support Rail Plate
- Auxiliary Contacts Type Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
- [Ie] Rated Operational Current 95 A 140 °F (60 °C)) <= 440 V AC-3 power circuit 125 A 140 °F (60 °C)) <= 690 V AC-1 power circuit
- Minimum Switching Current 5 mA signalling circuit
- Coil Technology Without built-in suppressor module
- Insulation Resistance > 10 MOhm signalling circuit
- Minimum Switching Voltage 17 V signalling circuit
- Signalling Circuit Frequency 25...400 Hz
- Heat Dissipation 6…10 W 50/60 Hz
- Maximum Operating Rate 3600 cyc/h 140 °F (60 °C)
- Mechanical Durability 4 Mcycles
- Front Cover With
- Rated Breaking Capacity 1100 A 440 V power circuit IEC 60947
- Average Impedance 0.8 mOhm - Ith 125 A 50 Hz power circuit
- Overvoltage Category III
- Auxiliary Contact Composition 1 NO + 1 NC
- [Uimp] Rated Impulse Withstand Voltage 8 kV IEC 60947
- Control Circuit Type AC 50/60 Hz
- [Uc] Control Circuit Voltage 220 V AC 50/60 Hz
- [Ue] Rated Operational Voltage Power circuit 1000 V AC 25...400 Hz
- Poles Description 3P
- Power Pole Contact Composition 3 NO
- Device Short Name LC1D
- Range TeSys
- Product Name TeSys D
- Product Or Component Type Contactor
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Related documents LC1D95M7 Specs
This item can ship within 24h!
Manufacturer warranty
$437.00
Stock:
17
Select Qty:
$437.00
$437.00 each
Worldwide Shipping and Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Relevant products
What can I help you find today?