LC1D40ABD Schneider Electric Industrial Automation Components


Part#:LC1D40ABD
Manufacturer:Schneider Electric
Category:Industrial Automation Components
Product Lifecycle:Active
Feb 27, 2025
Product description
Schneider Electric LC1D40ABD is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design and screw connections. This 3-pole (3P; 3NO) contactor is rated for currents of 60A (AC-1) and 40A (440Vac; AC-3), with a mounting mode suitable for DIN rail installation. It has a net width of 55 mm and offers a degree of protection rated at IP20. The control voltage (DC) ranges from 18-30Vdc, with a nominal 24Vdc, and it operates at a rated voltage (Ue) of up to 690 V. It includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 11kW at 220-230Vac to 30kW at 660-690Vac in AC-3 category. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 30HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of the LC1D40ABD is up to 6,000,000 operations, and its electrical durability with load reaches 1,500,000 operations. The rated voltage for phase-to-phase connections is 690 V.
Product Details
- Motor Power Kw 18.5 kW 380...400 V AC 50/60 Hz AC-3) 11 kW 220...230 V AC 50/60 Hz AC-3) 22 kW 415...440 V AC 50/60 Hz AC-3) 22 kW 500 V AC 50/60 Hz AC-3) 30 kW 660...690 V AC 50/60 Hz AC-3) 9 kW 400 V AC 50/60 Hz AC-4)
- [Ui] Rated Insulation Voltage Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL Power circuit 690 V IEC 60947-4-1
- Motor Power HP (UL / CSA) 5 hp 230/240 V at AC 50/60 Hz for 1 phase 10 hp 230/240 V at AC 50/60 Hz for 3 phase 30 hp 575/600 V at AC 50/60 Hz for 3 phase 10 hp 200/208 V at AC 50/60 Hz for 3 phase 3 hp 115 V at AC 50/60 Hz for 1 phase 30 hp 460/480 V at AC
- Standards CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
- [Icw] Rated Short-Time Withstand Current 320 A 104 °F (40 °C) - 10 s power circuit 720 A 104 °F (40 °C) - 1 s power circuit 72 A 104 °F (40 °C) - 10 min power circuit 165 A 104 °F (40 °C) - 1 min power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circ
- Product Certifications CCC CSA GOST UL
- Connections - Terminals Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)fle
- Irms Rated Making Capacity 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 800 A 440 V power circuit IEC 60947
- Control Circuit Voltage Limits 0.1...0.3 Uc -40…158 °F (-40…70 °C) drop-out DC 0.75...1.25 Uc -40…140 °F (-40…60 °C) operational DC 1...1.25 Uc 140…158 °F (60…70 °C) operational DC
- Tightening Torque Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Power circuit 70.81 lbf.in (8 N.m) EverLink BTR screw connectors 0.04…0.05 in² (25…35 mm²) hexagon
- Associated Fuse Rating 10 A gG signalling circuit IEC 60947-5-1 80 A gG <= 690 V type 1 power circuit 80 A gG <= 690 V type 2 power circuit
- Utilisation Category AC-1 AC-3 AC-4
- Non-Overlap Time 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
- Auxiliary Contacts Type Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
- Operating Time 42.5...57.5 ms closing 16...24 ms opening
- Contactor Application Resistive load Motor control
- [Ue] Rated Operational Voltage Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
- [Ie] Rated Operational Current 60 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit 40 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit
- Mounting Support Rail Plate
- Electrical Durability 0.7 Mcycles 60 A AC-1 <= 440 V 1.5 Mcycles 40 A AC-3 <= 440 V
- Power Dissipation Per Pole 2.4 W AC-3 5.4 W AC-1
- Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- [Ith] Conventional Free Air Thermal Current 10 A 140 °F (60 °C) signalling circuit 60 A 140 °F (60 °C) power circuit
- Insulation Resistance > 10 MOhm signalling circuit
- Signalling Circuit Frequency 25...400 Hz
- Minimum Switching Voltage 17 V signalling circuit
- Hold-In Power Consumption In W 7.4 W 68 °F (20 °C)
- Time Constant 34 ms
- Coil Technology Built-in bidirectional peak limiting diode suppressor
- Maximum Operating Rate 3600 cyc/h 140 °F (60 °C)
- Mechanical Durability 10 Mcycles
- Front Cover With
- Rated Breaking Capacity 800 A 440 V power circuit IEC 60947
- Minimum Switching Current 5 mA signalling circuit
- Inrush Power In W 19 W 68 °F (20 °C))
- Average Impedance 1.5 mOhm - Ith 60 A 50 Hz power circuit
- Overvoltage Category III
- [Uimp] Rated Impulse Withstand Voltage 6 kV IEC 60947
- [Uc] Control Circuit Voltage 24 V DC
- Auxiliary Contact Composition 1 NO + 1 NC
- Control Circuit Type DC standard
- Power Pole Contact Composition 3 NO
- Poles Description 3P
- Product Name TeSys D
- Product Or Component Type Contactor
- Device Short Name LC1D
- Range TeSys
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
LC1D40ABD Related Documents
Manufacturer warranty
Get a quick Quote!
Request a quote, and we will send you price within minutes.
Stock:
2
Select Qty:
Average response time: 11 minutes
Worldwide Shipping and Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Relevant products
What can I help you find today?