LC1D186BD Schneider Electric Industrial Automation Components


Part#:LC1D186BD
Manufacturer:Schneider Electric
Category:Industrial Automation Components
Product Lifecycle:Active
Product description
Schneider Electric LC1D186BD is a magnetic contactor from the Deca sub-range, designed with ring-lugs connections and three poles (3P; 3NO). It has a rated current of 32A for AC-1 and 18A for 440Vac in AC-3 conditions. This contactor is suitable for DIN rail mounting and has a net width of 45 mm. It offers a degree of protection rated at IP20 and operates with a control voltage (DC) range of 18-30Vdc, nominally at 24Vdc. The rated operating voltage (Ue) is up to 690 V, and it features 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. Its rated active power ranges from 4kW at 220-230Vac to 10kW at 660-690Vac in AC-3 conditions. Additionally, it includes 1 normally closed (NC) auxiliary contact with contacts type of 1NO+1NC instantaneous aux. The rated power in horsepower (HP) varies from 1HP at 115Vac in single-phase to 15HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of the LC1D186BD is up to 15 million operations at no load, and its electrical durability with load reaches 1.6 million operations. The rated voltage for phase-to-phase connections is 690 V.
Product Details
- Product Certifications LROS (Lloyds register of shipping) RINA DNV GOST BV CSA CCC GL UL
- [Ui] Rated Insulation Voltage Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL
- Standards CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
- Motor Power HP (UL / CSA) 1 hp 115 V at AC 50/60 Hz for 1 phase 3 hp 230/240 V at AC 50/60 Hz for 1 phase 5 hp 200/208 V at AC 50/60 Hz for 3 phase 5 hp 230/240 V at AC 50/60 Hz for 3 phase 10 hp 460/480 V at AC 50/60 Hz for 3 phase 15 hp 575/600 V at AC 5
- [Icw] Rated Short-Time Withstand Current 145 A 104 °F (40 °C) - 10 s power circuit 240 A 104 °F (40 °C) - 1 s power circuit 40 A 104 °F (40 °C) - 10 min power circuit 84 A 104 °F (40 °C) - 1 min power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circu
- Motor Power Kw 4 kW 220...230 V AC 50/60 Hz AC-3) 7.5 kW 380...400 V AC 50/60 Hz AC-3) 9 kW 415...440 V AC 50/60 Hz AC-3) 10 kW 500 V AC 50/60 Hz AC-3) 10 kW 660...690 V AC 50/60 Hz AC-3) 4 kW 400 V AC 50/60 Hz AC-4)
- Tightening Torque Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ø 6 mm M3.5 Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals Philips No 2 M3.5 Power circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ø 8 mm M3.5 Power circuit
- Control Circuit Voltage Limits 0.1...0.25 Uc -40…158 °F (-40…70 °C) drop-out DC 0.7...1.25 Uc -40…140 °F (-40…60 °C) operational DC 1...1.25 Uc 140…158 °F (60…70 °C) operational DC
- Irms Rated Making Capacity 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 300 A 440 V power circuit IEC 60947
- Associated Fuse Rating 10 A gG signalling circuit IEC 60947-5-1 50 A gG <= 690 V type 1 power circuit 35 A gG <= 690 V type 2 power circuit
- Utilisation Category AC-1 AC-4 AC-3
- Non-Overlap Time 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
- Auxiliary Contacts Type Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
- Operating Time 53.55...72.45 ms closing 16...24 ms opening
- Electrical Durability 1.65 Mcycles 18 A AC-3 <= 440 V 1 Mcycles 32 A AC-1 <= 440 V
- Contactor Application Motor control Resistive load
- Mounting Support Plate Rail
- Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- [Ith] Conventional Free Air Thermal Current 10 A 140 °F (60 °C) signalling circuit 32 A 140 °F (60 °C) power circuit
- [Ie] Rated Operational Current 18 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit 32 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
- Power Dissipation Per Pole 2.5 W AC-1 0.8 W AC-3
- Connections - Terminals Control circuit lugs-ring terminals 0.31 in (8 mm)) Power circuit lugs-ring terminals 0.31 in (8 mm))
- [Ue] Rated Operational Voltage Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
- Minimum Switching Voltage 17 V signalling circuit
- Insulation Resistance > 10 MOhm signalling circuit
- Minimum Switching Current 5 mA signalling circuit
- Signalling Circuit Frequency 25...400 Hz
- Inrush Power In W 5.4 W 68 °F (20 °C))
- Coil Technology With integral suppression device
- Hold-In Power Consumption In W 5.4 W 68 °F (20 °C)
- Time Constant 28 ms
- Maximum Operating Rate 3600 cyc/h 140 °F (60 °C)
- Mechanical Durability 30 Mcycles
- Front Cover With
- Rated Breaking Capacity 300 A 440 V power circuit IEC 60947
- Average Impedance 2.5 mOhm - Ith 32 A 50 Hz power circuit
- Auxiliary Contact Composition 1 NO + 1 NC
- Overvoltage Category III
- [Uc] Control Circuit Voltage 24 V DC
- Control Circuit Type DC standard
- [Uimp] Rated Impulse Withstand Voltage 6 kV IEC 60947
- Power Pole Contact Composition 3 NO
- Device Short Name LC1D
- Product Or Component Type Contactor
- Poles Description 3P
- Range TeSys
- Product Name TeSys D
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of LC1D186BD on Powermatic Associates is $201.12. Order now.
LC1D186BD Related Documents
Similar products from: Schneider Electric Industrial Automation Components
Manufacturer warranty
LC1D186BD Schneider Electric
$201.12
Your price can be lower.
Log in or Create account to check your discount
Select Qty:
$201.12
$201.12 each
Average response time: 11 minutes
Worldwide Shipping and Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare LC1D186BD with other Industrial Automation Components products
Product Certifications
[Ui] Rated Insulation Vol...
Standards
Motor Power HP (UL / CSA)
[Icw] Rated Short-Time Wi...
Motor Power Kw
Tightening Torque
Control Circuit Voltage L...
Irms Rated Making Capacit...
Associated Fuse Rating
Selected product

LC1D186BD
Schneider Electric
Schneider Electric LC1D186BD is a magnetic contactor from the Deca sub-range, designed with ring-lug...
Product CertificationsLROS (Lloyds register of shi...
[Ui] Rated Insulation VoltagePower circuit 690 V IEC 6094...
StandardsCSA C22.2 No 14 EN 60947-4-1...
Motor Power HP (UL / CSA)1 hp 115 V at AC 50/60 Hz fo...
[Icw] Rated Short-Time Withstand Current145 A 104 °F (40 °C) - 10 s ...
Motor Power Kw4 kW 220...230 V AC 50/60 Hz...
Tightening TorqueControl circuit 15.05 lbf.in...
Control Circuit Voltage Limits0.1...0.25 Uc -40…158 °F (-4...
Irms Rated Making Capacity140 A AC signalling circuit ...
Associated Fuse Rating10 A gG signalling circuit I...
About the manufacturer
Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...
Recently viewed products
Relevant products
FAQ
What is the price of LC1D186BD?
Purchase the LC1D186BD from Powermatic Associates at the price of $201.12. Order today.
Out if stock but available for backorder.
Schneider Electric LC1D186BD is a magnetic contactor from the Deca sub-range, designed with ring-lugs connections and three poles (3P; 3NO). It has a rated current of 32A for AC-1 and 18A for 440Vac in AC-3 conditions. This contactor is suitable for DIN rail mounting and has a net width of 45 mm. It offers a degree of protection rated at IP20 and operates with a control voltage (DC) range of 18-30Vdc, nominally at 24Vdc. The rated operating voltage (Ue) is up to 690 V, and it features 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. Its rated active power ranges from 4kW at 220-230Vac to 10kW at 660-690Vac in AC-3 conditions. Additionally, it includes 1 normally closed (NC) auxiliary contact with contacts type of 1NO+1NC instantaneous aux. The rated power in horsepower (HP) varies from 1HP at 115Vac in single-phase to 15HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of the LC1D186BD is up to 15 million operations at no load, and its electrical durability with load reaches 1.6 million operations. The rated voltage for phase-to-phase connections is 690 V.
Similar products from: Industrial Automation Components
What can I help you find today?