LC1D256BD Schneider Electric Industrial Automation Components
Part#:LC1D256BD
Manufacturer:Schneider Electric
Product Lifecycle:Active
In-stock parts: 41
Nov 16, 2024
IEC contactor, TeSys Deca, nonreversing, 25A, 15HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VDC coil, open style
About the manufacturer: Schneider Electric is one of the manufacturers that offers Industrial Automation Components that you can order at Powermatic Associates site. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.
Check out the LC1D256BD Schneider Electric price in the box on the right side or send a quick quote.
Product Details
- Product Certifications BV UL DNV CSA GL GOST LROS (Lloyds register of shipping) CCC RINA
- [Icw] Rated Short-Time Withstand Current 240 A 104 °F (40 °C) - 10 s power circuit 380 A 104 °F (40 °C) - 1 s power circuit 50 A 104 °F (40 °C) - 10 min power circuit 120 A 104 °F (40 °C) - 1 min power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circ
- Standards CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
- Motor Power Kw 5.5 kW 220...230 V AC 50/60 Hz AC-3) 11 kW 380...400 V AC 50/60 Hz AC-3) 11 kW 415...440 V AC 50/60 Hz AC-3) 15 kW 500 V AC 50/60 Hz AC-3) 15 kW 660...690 V AC 50/60 Hz AC-3) 5.5 kW 400 V AC 50/60 Hz AC-4)
- [Ui] Rated Insulation Voltage Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL
- Motor Power HP (UL / CSA) 3 hp 230/240 V at AC 50/60 Hz for 1 phase 2 hp 115 V at AC 50/60 Hz for 1 phase 7.5 hp 230/240 V at AC 50/60 Hz for 3 phase 15 hp 460/480 V at AC 50/60 Hz for 3 phase 20 hp 575/600 V at AC 50/60 Hz for 3 phase 7.5 hp 200/208 V at
- Tightening Torque Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ø 6 mm M3.5 Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals Philips No 2 M3.5 Power circuit 22.13 lbf.in (2.5 N.m) lugs-ring terminals flat Ø 8 mm M4 Power circuit 2
- Control Circuit Voltage Limits 0.1...0.25 Uc -40…158 °F (-40…70 °C) drop-out DC 0.7...1.25 Uc -40…140 °F (-40…60 °C) operational DC 1...1.25 Uc 140…158 °F (60…70 °C) operational DC
- Irms Rated Making Capacity 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 450 A 440 V power circuit IEC 60947
- Associated Fuse Rating 10 A gG signalling circuit IEC 60947-5-1 63 A gG <= 690 V type 1 power circuit 40 A gG <= 690 V type 2 power circuit
- Utilisation Category AC-3 AC-1 AC-4
- Power Dissipation Per Pole 3.2 W AC-1 1.25 W AC-3
- Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Connections - Terminals Control circuit lugs-ring terminals 0.31 in (8 mm)) Power circuit lugs-ring terminals 0.39 in (10 mm))
- Auxiliary Contacts Type Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
- Operating Time 53.55...72.45 ms closing 16...24 ms opening
- Electrical Durability 1.65 Mcycles 25 A AC-3 <= 440 V 1.4 Mcycles 40 A AC-1 <= 440 V
- [Ith] Conventional Free Air Thermal Current 10 A 140 °F (60 °C) signalling circuit 40 A 140 °F (60 °C) power circuit
- Non-Overlap Time 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
- Mounting Support Rail Plate
- [Ie] Rated Operational Current 25 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit 40 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
- Contactor Application Motor control Resistive load
- [Ue] Rated Operational Voltage Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
- Minimum Switching Current 5 mA signalling circuit
- Hold-In Power Consumption In W 5.4 W 68 °F (20 °C)
- Time Constant 28 ms
- Coil Technology Built-in bidirectional peak limiting diode suppressor
- Insulation Resistance > 10 MOhm signalling circuit
- Minimum Switching Voltage 17 V signalling circuit
- Signalling Circuit Frequency 25...400 Hz
- Inrush Power In W 5.4 W 68 °F (20 °C))
- Maximum Operating Rate 3600 cyc/h 140 °F (60 °C)
- Mechanical Durability 30 Mcycles
- Front Cover With
- Average Impedance 2 mOhm - Ith 40 A 50 Hz power circuit
- Rated Breaking Capacity 450 A 440 V power circuit IEC 60947
- Overvoltage Category III
- [Uimp] Rated Impulse Withstand Voltage 6 kV IEC 60947
- [Uc] Control Circuit Voltage 24 V DC
- Control Circuit Type DC standard
- Auxiliary Contact Composition 1 NO + 1 NC
- Power Pole Contact Composition 3 NO
- Poles Description 3P
- Device Short Name LC1D
- Product Or Component Type Contactor
- Range TeSys
- Product Name TeSys D
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Related documents LC1D256BD Specs
This item can ship within 24h!
Manufacturer warranty
$189.00
Stock:
41
Select Qty:
$189.00
$189.00 each
Worldwide Shipping and Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Relevant products
What can I help you find today?