Schneider Electric LP1K0610JD is a magnetic contactor from the K sub-range, designed with screw connections and equipped with 3 poles (3P; 3NO). It has a rated current of 6A at 440Vac under AC-3 conditions and a net width of 45 mm. This contactor offers a degree of protection of IP20 and operates with a control voltage (DC) range of 9.6-13.8Vdc, with a nominal 12Vdc. The rated operating voltage (Ue) is up to 690 V, and it includes 1 Normally Open (NO) auxiliary contact. The rated active power varies with voltage, providing 1.5kW at 220-230Vac, 2.2kW at 380-415Vac, and 3kW at 440Vac, 500Vac, and 660-690Vac, all under AC-3 conditions. It has no Normally Closed (NC) auxiliary contacts and boasts a mechanical durability of 10,000,000 operations at no load. The rated voltage (AC) phase-to-phase is 690 V.

Product Details

  • [Ui] Rated Insulation Voltage
    Power circuit 600 V UL 508 Power circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-5-1 Signalling circuit 600 V UL 508 Power circuit 600 V CSA C22.2 No 14 Signalling circuit
  • Rated Breaking Capacity
    110 A 415 V IEC 60947 110 A 440 V IEC 60947 80 A 500 V IEC 60947 110 A 220...230 V IEC 60947 110 A 380...400 V IEC 60947 70 A 660...690 V IEC 60947
  • Associated Fuse Rating
    25 A gG <= 440 V power circuit 25 A aM power circuit 10 A gG signalling circuit IEC 60947 10 A gG signalling circuit VDE 0660
  • Irms Rated Making Capacity
    110 A AC power circuit NF C 63-110 110 A AC power circuit IEC 60947 110 A AC signalling circuit IEC 60947
  • Flame Retardance
    V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
  • [Ith] Conventional Free Air Thermal Current
    20 A 122 °F (50 °C) power circuit 10 A 122 °F (50 °C) signalling circuit
  • Operating Time
    30...40 ms coil energisation and NO closing 10 ms coil de-energisation and NO opening
  • Tightening Torque
    11.51 lbf.in (1.3 N.m) screw clamp terminals Philips No 2 11.51 lbf.in (1.3 N.m) screw clamp terminals flat Ø 6 mm
  • [Ue] Rated Operational Voltage
    Power circuit 690 V AC 50/60 Hz Signalling circuit <= 690 V AC 50/60 Hz
  • Control Circuit Voltage Limits
    Operational: 0.8...1.15 Uc (at <50 °C) Drop-out 0.1...0.75 Uc 122 °F (50 °C))
  • Safety Reliability Level
    B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • Mounting Support
    Plate Rail
  • Utilisation Category
    AC-3 AC-4
  • Depth
    2.24 in (57 mm)
  • Net Weight
    0.50 lb(US) (0.225 kg)
  • Width
    1.77 in (45 mm)
  • Minimum Switching Voltage
    17 V signalling circuit
  • Height
    2.28 in (58 mm)
  • Insulation Resistance
    > 10 MOhm for signalling circuit
  • Minimum Switching Current
    5 mA signalling circuit
  • Mechanical Durability
    10 Mcycles
  • Maximum Operating Rate
    3600 cyc/h
  • Hold-In Power Consumption In W
    3 W 68 °F (20 °C)
  • Inrush Power In W
    3 W 68 °F (20 °C))
  • Average Impedance
    3 mOhm - Ith 20 A 50 Hz power circuit
  • Overvoltage Category
    III
  • [Uimp] Rated Impulse Withstand Voltage
    8 kV
  • Auxiliary Contacts Type
    Instantaneous 1 NO
  • [Uc] Control Circuit Voltage
    12 V DC
  • Auxiliary Contact Composition
    1 NO
  • Contactor Application
    Motor control
  • Pole Contact Composition
    3 NO
  • Product Or Component Type
    Contactor
  • Range
    TeSys
  • [Ie] Rated Operational Current
    6 A<= 440 V AC AC-3 power circuit
  • Poles Description
    3P
  • Device Short Name
    LP1K
  • Range Of Product
    TeSys K

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of LP1K0610JD on Powermatic Associates is $75.13. Order now.



Manufacturer warranty

LP1K0610JD Schneider Electric

$75.13

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$75.13

$75.13 each

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare LP1K0610JD with other products

[Ui] Rated Insulation Voltage

Rated Breaking Capacity

Associated Fuse Rating

Irms Rated Making Capacity

Flame Retardance

[Ith] Conventional Free Air Thermal Current

Operating Time

Tightening Torque

[Ue] Rated Operational Voltage

Control Circuit Voltage Limits

Safety Reliability Level

Mounting Support

Utilisation Category

Depth

Net Weight

Width

Minimum Switching Voltage

Height

Insulation Resistance

Minimum Switching Current

Mechanical Durability

Maximum Operating Rate

Hold-In Power Consumption In W

Inrush Power In W

Average Impedance

Overvoltage Category

[Uimp] Rated Impulse Withstand Voltage

Auxiliary Contacts Type

[Uc] Control Circuit Voltage

Auxiliary Contact Composition

Contactor Application

Pole Contact Composition

Product Or Component Type

Range

[Ie] Rated Operational Current

Poles Description

Device Short Name

Range Of Product

Product Certifications

[Icw] Rated Short-Time Withstand Current

[Ui] Rated Insulation Voltage

Motor Power HP (UL / CSA)

Motor Power Kw

Standards

Tightening Torque

Control Circuit Voltage Limits

Associated Fuse Rating

Irms Rated Making Capacity

Utilisation Category

Mounting Support

Non-Overlap Time

Auxiliary Contacts Type

[Ue] Rated Operational Voltage

Safety Reliability Level

Power Dissipation Per Pole

Operating Time

Connections - Terminals

Electrical Durability

[Ith] Conventional Free Air Thermal Current

[Ie] Rated Operational Current

Contactor Application

Minimum Switching Current

Maximum Operating Rate

Minimum Switching Voltage

Insulation Resistance

Signalling Circuit Frequency

Hold-In Power Consumption In W

Time Constant

Inrush Power In W

Mechanical Durability

Coil Technology

Front Cover

Average Impedance

Rated Breaking Capacity

Overvoltage Category

[Uimp] Rated Impulse Withstand Voltage

Control Circuit Type

[Uc] Control Circuit Voltage

Auxiliary Contact Composition

Product Name

Product Or Component Type

Range

Device Short Name

Poles Description

Power Pole Contact Composition

Motor Power Kw

[Ui] Rated Insulation Voltage

Motor Power HP (UL / CSA)

Standards

[Icw] Rated Short-Time Withstand Current

Product Certifications

Connections - Terminals

Irms Rated Making Capacity

Control Circuit Voltage Limits

Tightening Torque

Associated Fuse Rating

Utilisation Category

Non-Overlap Time

Auxiliary Contacts Type

Operating Time

Contactor Application

[Ue] Rated Operational Voltage

[Ie] Rated Operational Current

Mounting Support

Electrical Durability

Power Dissipation Per Pole

Safety Reliability Level

[Ith] Conventional Free Air Thermal Current

Insulation Resistance

Signalling Circuit Frequency

Minimum Switching Voltage

Hold-In Power Consumption In W

Time Constant

Coil Technology

Maximum Operating Rate

Mechanical Durability

Front Cover

Rated Breaking Capacity

Minimum Switching Current

Inrush Power In W

Average Impedance

Overvoltage Category

[Uimp] Rated Impulse Withstand Voltage

[Uc] Control Circuit Voltage

Auxiliary Contact Composition

Control Circuit Type

Power Pole Contact Composition

Poles Description

Product Name

Product Or Component Type

Device Short Name

Range

Selected product

LP1K0610JD
0 in stock
LP1K0610JD
Schneider Electric

Schneider Electric LP1K0610JD is a magnetic contactor from the K sub-range, designed with screw conn...

[Ui] Rated Insulation VoltagePower circuit 600 V UL 508 Power circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-5-1 Signalling circuit 600 V UL 508 Power circuit 600 V CSA C22.2 No 14 Signalling circuit

Rated Breaking Capacity110 A 415 V IEC 60947 110 A 440 V IEC 60947 80 A 500 V IEC 60947 110 A 220...230 V IEC 60947 110 A 380...400 V IEC 60947 70 A 660...690 V IEC 60947

Associated Fuse Rating25 A gG <= 440 V power circuit 25 A aM power circuit 10 A gG signalling circuit IEC 60947 10 A gG signalling circuit VDE 0660

Irms Rated Making Capacity110 A AC power circuit NF C 63-110 110 A AC power circuit IEC 60947 110 A AC signalling circuit IEC 60947

Flame RetardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102

[Ith] Conventional Free Air Thermal Current20 A 122 °F (50 °C) power circuit 10 A 122 °F (50 °C) signalling circuit

Operating Time30...40 ms coil energisation and NO closing 10 ms coil de-energisation and NO opening

Tightening Torque11.51 lbf.in (1.3 N.m) screw clamp terminals Philips No 2 11.51 lbf.in (1.3 N.m) screw clamp terminals flat Ø 6 mm

[Ue] Rated Operational VoltagePower circuit 690 V AC 50/60 Hz Signalling circuit <= 690 V AC 50/60 Hz

Control Circuit Voltage LimitsOperational: 0.8...1.15 Uc (at <50 °C) Drop-out 0.1...0.75 Uc 122 °F (50 °C))

Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1

Mounting SupportPlate Rail

Utilisation CategoryAC-3 AC-4

Depth2.24 in (57 mm)

Net Weight0.50 lb(US) (0.225 kg)

Width1.77 in (45 mm)

Minimum Switching Voltage17 V signalling circuit

Height2.28 in (58 mm)

Insulation Resistance> 10 MOhm for signalling circuit

Minimum Switching Current5 mA signalling circuit

Mechanical Durability10 Mcycles

Maximum Operating Rate3600 cyc/h

Hold-In Power Consumption In W3 W 68 °F (20 °C)

Inrush Power In W3 W 68 °F (20 °C))

Average Impedance3 mOhm - Ith 20 A 50 Hz power circuit

Overvoltage CategoryIII

[Uimp] Rated Impulse Withstand Voltage8 kV

Auxiliary Contacts TypeInstantaneous 1 NO

[Uc] Control Circuit Voltage12 V DC

Auxiliary Contact Composition1 NO

Contactor ApplicationMotor control

Pole Contact Composition3 NO

Product Or Component TypeContactor

RangeTeSys

[Ie] Rated Operational Current6 A<= 440 V AC AC-3 power circuit

Poles Description3P

Device Short NameLP1K

Range Of ProductTeSys K

Product Certifications-

[Icw] Rated Short-Time Withstand Current-

[Ui] Rated Insulation Voltage-

Motor Power HP (UL / CSA)-

Motor Power Kw-

Standards-

Tightening Torque-

Control Circuit Voltage Limits-

Associated Fuse Rating-

Irms Rated Making Capacity-

Utilisation Category-

Mounting Support-

Non-Overlap Time-

Auxiliary Contacts Type-

[Ue] Rated Operational Voltage-

Safety Reliability Level-

Power Dissipation Per Pole-

Operating Time-

Connections - Terminals-

Electrical Durability-

[Ith] Conventional Free Air Thermal Current-

[Ie] Rated Operational Current-

Contactor Application-

Minimum Switching Current-

Maximum Operating Rate-

Minimum Switching Voltage-

Insulation Resistance-

Signalling Circuit Frequency-

Hold-In Power Consumption In W-

Time Constant-

Inrush Power In W-

Mechanical Durability-

Coil Technology-

Front Cover-

Average Impedance-

Rated Breaking Capacity-

Overvoltage Category-

[Uimp] Rated Impulse Withstand Voltage-

Control Circuit Type-

[Uc] Control Circuit Voltage-

Auxiliary Contact Composition-

Product Name-

Product Or Component Type-

Range-

Device Short Name-

Poles Description-

Power Pole Contact Composition-

Motor Power Kw-

[Ui] Rated Insulation Voltage-

Motor Power HP (UL / CSA)-

Standards-

[Icw] Rated Short-Time Withstand Current-

Product Certifications-

Connections - Terminals-

Irms Rated Making Capacity-

Control Circuit Voltage Limits-

Tightening Torque-

Associated Fuse Rating-

Utilisation Category-

Non-Overlap Time-

Auxiliary Contacts Type-

Operating Time-

Contactor Application-

[Ue] Rated Operational Voltage-

[Ie] Rated Operational Current-

Mounting Support-

Electrical Durability-

Power Dissipation Per Pole-

Safety Reliability Level-

[Ith] Conventional Free Air Thermal Current-

Insulation Resistance-

Signalling Circuit Frequency-

Minimum Switching Voltage-

Hold-In Power Consumption In W-

Time Constant-

Coil Technology-

Maximum Operating Rate-

Mechanical Durability-

Front Cover-

Rated Breaking Capacity-

Minimum Switching Current-

Inrush Power In W-

Average Impedance-

Overvoltage Category-

[Uimp] Rated Impulse Withstand Voltage-

[Uc] Control Circuit Voltage-

Auxiliary Contact Composition-

Control Circuit Type-

Power Pole Contact Composition-

Poles Description-

Product Name-

Product Or Component Type-

Device Short Name-

Range-

LC1D186BL
18 in stock
LC1D186BL
Schneider Electric

Schneider Electric LC1D186BL is a magnetic contactor from the Deca sub-range, designed with a low-co...

[Ui] Rated Insulation Voltage-

Rated Breaking Capacity-

Associated Fuse Rating-

Irms Rated Making Capacity-

Flame Retardance-

[Ith] Conventional Free Air Thermal Current-

Operating Time-

Tightening Torque-

[Ue] Rated Operational Voltage-

Control Circuit Voltage Limits-

Safety Reliability Level-

Mounting Support-

Utilisation Category-

Depth-

Net Weight-

Width-

Minimum Switching Voltage-

Height-

Insulation Resistance-

Minimum Switching Current-

Mechanical Durability-

Maximum Operating Rate-

Hold-In Power Consumption In W-

Inrush Power In W-

Average Impedance-

Overvoltage Category-

[Uimp] Rated Impulse Withstand Voltage-

Auxiliary Contacts Type-

[Uc] Control Circuit Voltage-

Auxiliary Contact Composition-

Contactor Application-

Pole Contact Composition-

Product Or Component Type-

Range-

[Ie] Rated Operational Current-

Poles Description-

Device Short Name-

Range Of Product-

Product CertificationsLROS (Lloyds register of shipping) GOST DNV RINA GL UL BV CSA CCC

[Icw] Rated Short-Time Withstand Current145 A 104 °F (40 °C) - 10 s power circuit 240 A 104 °F (40 °C) - 1 s power circuit 40 A 104 °F (40 °C) - 10 min power circuit 84 A 104 °F (40 °C) - 1 min power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circu

[Ui] Rated Insulation VoltagePower circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL

Motor Power HP (UL / CSA)1 hp 115 V at AC 50/60 Hz for 1 phase 3 hp 230/240 V at AC 50/60 Hz for 1 phase 5 hp 200/208 V at AC 50/60 Hz for 3 phase 5 hp 230/240 V at AC 50/60 Hz for 3 phase 10 hp 460/480 V at AC 50/60 Hz for 3 phase 15 hp 575/600 V at AC 5

Motor Power Kw4 kW 220...230 V AC 50/60 Hz AC-3) 7.5 kW 380...400 V AC 50/60 Hz AC-3) 9 kW 415...440 V AC 50/60 Hz AC-3) 10 kW 500 V AC 50/60 Hz AC-3) 10 kW 660...690 V AC 50/60 Hz AC-3) 4 kW 400 V AC 50/60 Hz AC-4)

StandardsCSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508

Tightening TorqueControl circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ø 6 mm M3.5 Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals Philips No 2 M3.5 Power circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ø 8 mm M3.5 Power circuit

Control Circuit Voltage Limits0.1...0.3 Uc -40…158 °F (-40…70 °C) drop-out DC 0.8...1.25 Uc -40…140 °F (-40…60 °C) operational DC 1...1.25 Uc 140…158 °F (60…70 °C) operational DC

Associated Fuse Rating10 A gG signalling circuit IEC 60947-5-1 50 A gG <= 690 V type 1 power circuit 35 A gG <= 690 V type 2 power circuit

Irms Rated Making Capacity140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 300 A 440 V power circuit IEC 60947

Utilisation CategoryAC-3 AC-1 AC-4

Mounting SupportRail Plate

Non-Overlap Time1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact

Auxiliary Contacts Typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1

[Ue] Rated Operational VoltagePower circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC

Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1

Power Dissipation Per Pole2.5 W AC-1 0.8 W AC-3

Operating Time65.45...88.55 ms closing 20...30 ms opening

Connections - TerminalsControl circuit lugs-ring terminals 0.31 in (8 mm)) Power circuit lugs-ring terminals 0.31 in (8 mm))

Electrical Durability1.65 Mcycles 18 A AC-3 <= 440 V 1 Mcycles 32 A AC-1 <= 440 V

[Ith] Conventional Free Air Thermal Current10 A 140 °F (60 °C) signalling circuit 32 A 140 °F (60 °C) power circuit

[Ie] Rated Operational Current18 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit 32 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit

Contactor ApplicationMotor control Resistive load

Minimum Switching Current5 mA signalling circuit

Maximum Operating Rate3600 cyc/h 60 °C

Minimum Switching Voltage17 V signalling circuit

Insulation Resistance> 10 MOhm for signalling circuit

Signalling Circuit Frequency25...400 Hz

Hold-In Power Consumption In W2.4 W 68 °F (20 °C)

Time Constant40 ms

Inrush Power In W2.4 W 68 °F (20 °C))

Mechanical Durability30 Mcycles

Coil TechnologyBuilt-in bidirectional peak limiting diode suppressor

Front CoverWith

Average Impedance2.5 mOhm - Ith 32 A 50 Hz power circuit

Rated Breaking Capacity300 A 440 V power circuit IEC 60947

Overvoltage CategoryIII

[Uimp] Rated Impulse Withstand Voltage6 kV IEC 60947

Control Circuit TypeDC low consumption

[Uc] Control Circuit Voltage24 V DC

Auxiliary Contact Composition1 NO + 1 NC

Product NameTeSys D

Product Or Component TypeContactor

RangeTeSys

Device Short NameLC1D

Poles Description3P

Power Pole Contact Composition3 NO

Motor Power Kw-

[Ui] Rated Insulation Voltage-

Motor Power HP (UL / CSA)-

Standards-

[Icw] Rated Short-Time Withstand Current-

Product Certifications-

Connections - Terminals-

Irms Rated Making Capacity-

Control Circuit Voltage Limits-

Tightening Torque-

Associated Fuse Rating-

Utilisation Category-

Non-Overlap Time-

Auxiliary Contacts Type-

Operating Time-

Contactor Application-

[Ue] Rated Operational Voltage-

[Ie] Rated Operational Current-

Mounting Support-

Electrical Durability-

Power Dissipation Per Pole-

Safety Reliability Level-

[Ith] Conventional Free Air Thermal Current-

Insulation Resistance-

Signalling Circuit Frequency-

Minimum Switching Voltage-

Hold-In Power Consumption In W-

Time Constant-

Coil Technology-

Maximum Operating Rate-

Mechanical Durability-

Front Cover-

Rated Breaking Capacity-

Minimum Switching Current-

Inrush Power In W-

Average Impedance-

Overvoltage Category-

[Uimp] Rated Impulse Withstand Voltage-

[Uc] Control Circuit Voltage-

Auxiliary Contact Composition-

Control Circuit Type-

Power Pole Contact Composition-

Poles Description-

Product Name-

Product Or Component Type-

Device Short Name-

Range-

LC1D40ABD
2 in stock
LC1D40ABD
Schneider Electric

Schneider Electric LC1D40ABD is a magnetic contactor from the Deca sub-range, featuring EverLink(TM)...

[Ui] Rated Insulation Voltage-

Rated Breaking Capacity-

Associated Fuse Rating-

Irms Rated Making Capacity-

Flame Retardance-

[Ith] Conventional Free Air Thermal Current-

Operating Time-

Tightening Torque-

[Ue] Rated Operational Voltage-

Control Circuit Voltage Limits-

Safety Reliability Level-

Mounting Support-

Utilisation Category-

Depth-

Net Weight-

Width-

Minimum Switching Voltage-

Height-

Insulation Resistance-

Minimum Switching Current-

Mechanical Durability-

Maximum Operating Rate-

Hold-In Power Consumption In W-

Inrush Power In W-

Average Impedance-

Overvoltage Category-

[Uimp] Rated Impulse Withstand Voltage-

Auxiliary Contacts Type-

[Uc] Control Circuit Voltage-

Auxiliary Contact Composition-

Contactor Application-

Pole Contact Composition-

Product Or Component Type-

Range-

[Ie] Rated Operational Current-

Poles Description-

Device Short Name-

Range Of Product-

Product Certifications-

[Icw] Rated Short-Time Withstand Current-

[Ui] Rated Insulation Voltage-

Motor Power HP (UL / CSA)-

Motor Power Kw-

Standards-

Tightening Torque-

Control Circuit Voltage Limits-

Associated Fuse Rating-

Irms Rated Making Capacity-

Utilisation Category-

Mounting Support-

Non-Overlap Time-

Auxiliary Contacts Type-

[Ue] Rated Operational Voltage-

Safety Reliability Level-

Power Dissipation Per Pole-

Operating Time-

Connections - Terminals-

Electrical Durability-

[Ith] Conventional Free Air Thermal Current-

[Ie] Rated Operational Current-

Contactor Application-

Minimum Switching Current-

Maximum Operating Rate-

Minimum Switching Voltage-

Insulation Resistance-

Signalling Circuit Frequency-

Hold-In Power Consumption In W-

Time Constant-

Inrush Power In W-

Mechanical Durability-

Coil Technology-

Front Cover-

Average Impedance-

Rated Breaking Capacity-

Overvoltage Category-

[Uimp] Rated Impulse Withstand Voltage-

Control Circuit Type-

[Uc] Control Circuit Voltage-

Auxiliary Contact Composition-

Product Name-

Product Or Component Type-

Range-

Device Short Name-

Poles Description-

Power Pole Contact Composition-

Motor Power Kw18.5 kW 380...400 V AC 50/60 Hz AC-3) 11 kW 220...230 V AC 50/60 Hz AC-3) 22 kW 415...440 V AC 50/60 Hz AC-3) 22 kW 500 V AC 50/60 Hz AC-3) 30 kW 660...690 V AC 50/60 Hz AC-3) 9 kW 400 V AC 50/60 Hz AC-4)

[Ui] Rated Insulation VoltagePower circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL Power circuit 690 V IEC 60947-4-1

Motor Power HP (UL / CSA)5 hp 230/240 V at AC 50/60 Hz for 1 phase 10 hp 230/240 V at AC 50/60 Hz for 3 phase 30 hp 575/600 V at AC 50/60 Hz for 3 phase 10 hp 200/208 V at AC 50/60 Hz for 3 phase 3 hp 115 V at AC 50/60 Hz for 1 phase 30 hp 460/480 V at AC

StandardsCSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508

[Icw] Rated Short-Time Withstand Current320 A 104 °F (40 °C) - 10 s power circuit 720 A 104 °F (40 °C) - 1 s power circuit 72 A 104 °F (40 °C) - 10 min power circuit 165 A 104 °F (40 °C) - 1 min power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circ

Product CertificationsCCC CSA GOST UL

Connections - TerminalsControl circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)fle

Irms Rated Making Capacity140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 800 A 440 V power circuit IEC 60947

Control Circuit Voltage Limits0.1...0.3 Uc -40…158 °F (-40…70 °C) drop-out DC 0.75...1.25 Uc -40…140 °F (-40…60 °C) operational DC 1...1.25 Uc 140…158 °F (60…70 °C) operational DC

Tightening TorqueControl circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Power circuit 70.81 lbf.in (8 N.m) EverLink BTR screw connectors 0.04…0.05 in² (25…35 mm²) hexagon

Associated Fuse Rating10 A gG signalling circuit IEC 60947-5-1 80 A gG <= 690 V type 1 power circuit 80 A gG <= 690 V type 2 power circuit

Utilisation CategoryAC-1 AC-3 AC-4

Non-Overlap Time1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact

Auxiliary Contacts TypeMechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1

Operating Time42.5...57.5 ms closing 16...24 ms opening

Contactor ApplicationResistive load Motor control

[Ue] Rated Operational VoltagePower circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC

[Ie] Rated Operational Current60 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit 40 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit

Mounting SupportRail Plate

Electrical Durability0.7 Mcycles 60 A AC-1 <= 440 V 1.5 Mcycles 40 A AC-3 <= 440 V

Power Dissipation Per Pole2.4 W AC-3 5.4 W AC-1

Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1

[Ith] Conventional Free Air Thermal Current10 A 140 °F (60 °C) signalling circuit 60 A 140 °F (60 °C) power circuit

Insulation Resistance> 10 MOhm signalling circuit

Signalling Circuit Frequency25...400 Hz

Minimum Switching Voltage17 V signalling circuit

Hold-In Power Consumption In W7.4 W 68 °F (20 °C)

Time Constant34 ms

Coil TechnologyBuilt-in bidirectional peak limiting diode suppressor

Maximum Operating Rate3600 cyc/h 140 °F (60 °C)

Mechanical Durability10 Mcycles

Front CoverWith

Rated Breaking Capacity800 A 440 V power circuit IEC 60947

Minimum Switching Current5 mA signalling circuit

Inrush Power In W19 W 68 °F (20 °C))

Average Impedance1.5 mOhm - Ith 60 A 50 Hz power circuit

Overvoltage CategoryIII

[Uimp] Rated Impulse Withstand Voltage6 kV IEC 60947

[Uc] Control Circuit Voltage24 V DC

Auxiliary Contact Composition1 NO + 1 NC

Control Circuit TypeDC standard

Power Pole Contact Composition3 NO

Poles Description3P

Product NameTeSys D

Product Or Component TypeContactor

Device Short NameLC1D

RangeTeSys

About the manufacturer

Schneider Electric

Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. Their extensive product line includes advanced electrical distribution equipment, smart grid solutions, building automation systems, and renewable energy technologies, all designed to enhance operational performance while minimizing environmental impact. Schneider Electric's comprehensive range of products includes circuit breakers, motor starters, contactors, relays, and variable speed drives, which are essential for ensuring safety and reliability in electrical installations. Furthermore, their sophisticated software platforms enable real-time monitoring and management of energy consumption, optimizing processes and reducing costs. Their innovative EcoStruxure architecture leverages IoT technology to deliver seamless connectivity, predictive analytics, and actionable insights, empowering businesses to make informed decisions and achieve greater operational agility. At Powermatic Associates, we recognize the transformative power of Schneider Electric's offerings and are committed to delivering these state-of-the-art solutions to our customers. Through this partnership, we provide unparalleled access to high-quality components that enhance system integration, improve energy efficiency, and bolster resilience. Our expert engineering support and tailored automation solutions ensure that your projects benefit from the latest advancements in technology. Whether you're looking for robust power distribution units or intelligent control systems, our collaboration with Schneider Electric guarantees that you receive superior products backed by industry-leading technical support. By choosing Powermatic Associates as your trusted distributor, you gain access to Schneider Electric’s innovative solutions and our value-added services, which together streamline procurement, optimize operations, and drive sustainable growth. Our expertise in motion, controls, pneumatics, and electrical solutions, combined with Schneider Electric's pioneering technologies, ensures that we remain at the forefront of delivering reliable and efficient solutions to meet your operational challenges. As partners, we are dedicated to helping you harness the power of technology to achieve peak performance and enhanced profitability in your business endeavors.

Recently viewed products

Relevant products

FAQ

What is the price of LP1K0610JD?
The price of LP1K0610JD on Powermatic Associates is $75.13. Order now.

Out if stock but available for backorder.

Schneider Electric LP1K0610JD is a magnetic contactor from the K sub-range, designed with screw connections and equipped with 3 poles (3P; 3NO). It has a rated current of 6A at 440Vac under AC-3 conditions and a net width of 45 mm. This contactor offers a degree of protection of IP20 and operates with a control voltage (DC) range of 9.6-13.8Vdc, with a nominal 12Vdc. The rated operating voltage (Ue) is up to 690 V, and it includes 1 Normally Open (NO) auxiliary contact. The rated active power varies with voltage, providing 1.5kW at 220-230Vac, 2.2kW at 380-415Vac, and 3kW at 440Vac, 500Vac, and 660-690Vac, all under AC-3 conditions. It has no Normally Closed (NC) auxiliary contacts and boasts a mechanical durability of 10,000,000 operations at no load. The rated voltage (AC) phase-to-phase is 690 V.

Similar products from: Industrial Automation Components

What can I help you find today?

Recommended parts