LC1DT206BL Schneider Electric Industrial Automation Components

LC1DT206BL on Powermatic Associates
Schneider Electric

Part#:LC1DT206BL

Manufacturer:Schneider Electric

Category:Industrial Automation Components

Product Lifecycle:Active

Only 3 left in stock. Order Now!

Apr 2, 2025

Product description

Schneider Electric LC1DT206BL is a magnetic contactor from the Deca sub-range, designed with a low-consumption coil that uses less than 2.4W of power. It features ring-lugs connections and is equipped with 4 poles (4NO) for comprehensive circuit control. This contactor is rated for a current of 20A under AC-1 conditions and can be mounted on a DIN rail for easy installation. With a net width of 45 mm and an IP20 degree of protection, it ensures a compact and secure setup. The control voltage ranges from 19.2 to 30Vdc, with a nominal 24Vdc, allowing for flexible operation within 0.8 to 1.25 times the control voltage (Uc). It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, both designed for instantaneous operation. The LC1DT206BL boasts a mechanical durability of 15 million operations at no load and can handle rated impulse voltages up to 6 kV. It supports a phase-to-phase rated voltage up to 690 V AC, ensuring compatibility with a wide range of electrical systems.

Product Details

  • Product Certifications
    UL GOST CSA RINA CCC BV LROS (Lloyds register of shipping) DNV GL
  • [Icw] Rated Short-Time Withstand Current
    30 A 104 °F (40 °C) - 10 min power circuit 61 A 104 °F (40 °C) - 1 min power circuit 105 A 104 °F (40 °C) - 10 s power circuit 210 A 104 °F (40 °C) - 1 s power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circu
  • [Ui] Rated Insulation Voltage
    Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL Power circuit 690 V IEC 60947-4-1
  • Tightening Torque
    Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ø 6 mm M3.5 Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals Philips No 2 M3.5 Power circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ø 6 mm M3.5 Power circuit
  • Standards
    CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
  • Associated Fuse Rating
    10 A gG signalling circuit IEC 60947-5-1 25 A gG <= 690 V type 1 power circuit 20 A gG <= 690 V type 2 power circuit
  • Control Circuit Voltage Limits
    0.1...0.3 Uc -40…158 °F (-40…70 °C) drop-out DC 0.8...1.25 Uc -40…140 °F (-40…60 °C) operational DC 1...1.25 Uc 140…158 °F (60…70 °C) operational DC
  • Irms Rated Making Capacity
    140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 250 A 440 V power circuit IEC 60947
  • Operating Time
    65.45...88.55 ms closing 20...30 ms opening
  • Safety Reliability Level
    B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • Non-Overlap Time
    1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
  • [Ue] Rated Operational Voltage
    Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
  • [Ith] Conventional Free Air Thermal Current
    10 A 140 °F (60 °C) signalling circuit 20 A 140 °F (60 °C) power circuit
  • Mounting Support
    Rail Plate
  • Auxiliary Contacts Type
    Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
  • Connections - Terminals
    Control circuit lugs-ring terminals 0.31 in (8 mm)) Power circuit lugs-ring terminals 0.31 in (8 mm))
  • Insulation Resistance
    > 10 MOhm signalling circuit
  • Signalling Circuit Frequency
    25...400 Hz
  • Minimum Switching Current
    5 mA signalling circuit
  • Hold-In Power Consumption In W
    2.4 W 68 °F (20 °C)
  • Time Constant
    40 ms
  • Maximum Operating Rate
    3600 cyc/h 140 °F (60 °C)
  • Minimum Switching Voltage
    17 V signalling circuit
  • Coil Technology
    Built-in bidirectional peak limiting diode suppressor
  • Inrush Power In W
    2.4 W 68 °F (20 °C))
  • Mechanical Durability
    30 Mcycles
  • Front Cover
    With
  • Power Dissipation Per Pole
    1.56 W AC-1
  • Rated Breaking Capacity
    250 A 440 V power circuit IEC 60947
  • Average Impedance
    2.5 mOhm - Ith 20 A 50 Hz power circuit
  • Auxiliary Contact Composition
    1 NO + 1 NC
  • Overvoltage Category
    III
  • [Uimp] Rated Impulse Withstand Voltage
    6 kV IEC 60947
  • [Uc] Control Circuit Voltage
    24 V DC
  • Control Circuit Type
    DC low consumption
  • [Ie] Rated Operational Current
    20 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
  • Power Pole Contact Composition
    4 NO
  • Utilisation Category
    AC-1
  • Product Or Component Type
    Contactor
  • Contactor Application
    Resistive load
  • Range
    TeSys
  • Device Short Name
    LC1D
  • Product Name
    TeSys D
  • Poles Description
    4P

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of LC1DT206BL on Powermatic Associates is $158.00. Order now.



Similar products from: Schneider Electric Industrial Automation Components

BJF36100 on Powermatic Associates

BJF36100

Schneider Electric

Square D by Schneider Electric BJF36100 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJF sub-range, featuring a PowerPact B-Frame 100 TMD 3P-3t design. It has a rated current of 100A and operates at a rated voltage of 600Vac 600Y/347Vac, with a rated impulse voltage (Uimp) of 8 kV. The connection type is a terminal nut kit for fixed busbar connection on both line and load sides, and it offers a degree of protection of IP40. This MCCB has a mechanical durability of 15,000 operations and can be mounted on a DIN rail or as an individual unit on a plate. It has 3 poles (3P) and falls under the utilization category A. The dimensions are 137 mm in height, 80 mm in depth, and 81 mm in width. Its protection settings include over-current fixed at 100A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated voltage for DC operations is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 690 V. It provides thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 100 AT. The electrical durability with load is 10,000 operations at 440Vac. The frame current rating is 100 AF, and it operates via a toggle (manual) mode. The short circuit breaking rating varies with voltage, offering 100kA at 240Vac, 65kA at 480Vac and 480Y/277Vac, 25kA at 600Y/347Vac for UL489 standards, and 50kA at 250Vdc. The trip unit type is thermal-magnetic (fixed) with no display.

1 in stock

This item can ship within 24h!

Manufacturer warranty

LC1DT206BL Schneider Electric

$158.00

Your price can be lower.
Log in or Create account to check your discount

Stock:

3

Select Qty:

$158.00

$158.00 each

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare LC1DT206BL with other Industrial Automation Components products

Product Certifications

[Icw] Rated Short-Time Wi...

[Ui] Rated Insulation Vol...

Tightening Torque

Standards

Associated Fuse Rating

Control Circuit Voltage L...

Irms Rated Making Capacit...

Operating Time

Safety Reliability Level

Selected product

LC1DT206BL
3 in stock
LC1DT206BL
Schneider Electric

Schneider Electric LC1DT206BL is a magnetic contactor from the Deca sub-range, designed with a low-c...

Product CertificationsUL GOST CSA RINA CCC BV LROS...

[Icw] Rated Short-Time Withstand Current30 A 104 °F (40 °C) - 10 min...

[Ui] Rated Insulation VoltagePower circuit 600 V CSA Powe...

Tightening TorqueControl circuit 15.05 lbf.in...

StandardsCSA C22.2 No 14 EN 60947-4-1...

Associated Fuse Rating10 A gG signalling circuit I...

Control Circuit Voltage Limits0.1...0.3 Uc -40…158 °F (-40...

Irms Rated Making Capacity140 A AC signalling circuit ...

Operating Time65.45...88.55 ms closing 20....

Safety Reliability LevelB10d = 1369863 cycles contac...

LC1DT20BL
2 in stock
LC1DT20BL
Schneider Electric

Schneider Electric LC1DT20BL is a magnetic contactor from the Deca sub-range, designed with a low-co...

Product Certifications-

[Icw] Rated Short-Time Withstand Current-

[Ui] Rated Insulation Voltage-

Tightening Torque-

Standards-

Associated Fuse Rating10 A gG signalling circuit I...

Control Circuit Voltage Limits-

Irms Rated Making Capacity-

Operating Time-

Safety Reliability Level-

LC1D093BD
35 in stock
LC1D093BD
Schneider Electric

Schneider Electric LC1D093BD is a magnetic contactor from the Deca sub-range, featuring spring conne...

Product Certifications-

[Icw] Rated Short-Time Withstand Current-

[Ui] Rated Insulation Voltage-

Tightening Torque-

Standards-

Associated Fuse Rating10 A gG signalling circuit I...

Control Circuit Voltage Limits-

Irms Rated Making Capacity-

Operating Time-

Safety Reliability Level-

About the manufacturer

Schneider Electric

Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...

Recently viewed products

Relevant products

FAQ

What is the price of LC1DT206BL?
Purchase the LC1DT206BL from Powermatic Associates at the price of $158.00. Order today.

3 in stock

Schneider Electric LC1DT206BL is a magnetic contactor from the Deca sub-range, designed with a low-consumption coil that uses less than 2.4W of power. It features ring-lugs connections and is equipped with 4 poles (4NO) for comprehensive circuit control. This contactor is rated for a current of 20A under AC-1 conditions and can be mounted on a DIN rail for easy installation. With a net width of 45 mm and an IP20 degree of protection, it ensures a compact and secure setup. The control voltage ranges from 19.2 to 30Vdc, with a nominal 24Vdc, allowing for flexible operation within 0.8 to 1.25 times the control voltage (Uc). It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, both designed for instantaneous operation. The LC1DT206BL boasts a mechanical durability of 15 million operations at no load and can handle rated impulse voltages up to 6 kV. It supports a phase-to-phase rated voltage up to 690 V AC, ensuring compatibility with a wide range of electrical systems.

Similar products from: Industrial Automation Components