Ground modular terminal block, connection method: Screw connection, number of connections: 2, cross section: 0.2 mm² - 6 mm², AWG: 24 - 10, width: 6.2 mm, color: green-yellow, mounting type: NS 35/7,5, NS 35/15, NS 32

Product Details

  • Height NS 35/7,5
    47 mm
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
    0.25 mm²
  • Rated surge voltage
    8 kV
  • Open side panel
    No
  • Insulating material group
    I
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • Number of levels
    1
  • ECLASS 9.0
    27141141
  • ECLASS 10.0.1
    27141141
  • Connection method
    Screw connection
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
    1.5 mm²
  • Number of connections
    2
  • Flammability rating according to UL 94
    V0
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    125 °C
  • ECLASS 6.0
    27141100
  • ETIM 3.0
    EC000901
  • UNSPSC 6.01
    30211811
  • Static insulating material application in cold
    -60 °C
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ETIM 7.0
    EC000901
  • Maximum power dissipation for nominal condition
    1.02 W
  • ECLASS 11.0
    27141141
  • ECLASS 7.0
    27141141
  • UNSPSC 19.0
    39121410
  • UNSPSC 18.0
    39121410
  • Terminal block mounting
    0.6 Nm ... 0.8 Nm (PE foot with mounting screw, M3)
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Color
    green-yellow
  • Overvoltage category
    III
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Insulating material
    PA
  • Degree of pollution
    3
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Note
    Please observe the current carrying capacity of the DIN rails.
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Height NS 35/15
    54.5 mm
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section flexible min.
    0.2 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    4 mm²
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 5.0
    27141100
  • ECLASS 5.1
    27141100
  • ETIM 6.0
    EC000901
  • Tightening torque, min
    0.6 Nm
  • Conductor cross section flexible max.
    4 mm²
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Length
    42.5 mm
  • Tightening torque max
    0.8 Nm
  • 2 conductors with same cross section, solid min.
    0.2 mm²
  • 2 conductors with same cross section, stranded max.
    1.5 mm²
  • Conductor cross section AWG min.
    24
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.25 mm²
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • Min. AWG conductor cross section, flexible
    24
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Screw thread
    M3
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.25 mm²
  • 2 conductors with same cross section, stranded min.
    0.2 mm²
  • Conductor cross section solid max.
    4 mm²
  • Connection in acc. with standard
    CSA
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    2.5 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • ECLASS 4.0
    27141100
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Height NS 32
    52 mm
  • Max. AWG conductor cross section, flexible
    12
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    2.5 mm²
  • UNSPSC 21.0
    39121410
  • Stripping length
    8 mm
  • 2 conductors with same cross section, solid max.
    1.5 mm²
  • Width
    6.2 mm
  • Conductor cross section AWG max.
    12
  • Nominal cross section
    4 mm²
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    27,5 MJ/kg
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 4.1
    27141100
  • ETIM 2.0
    EC000901
  • UNSPSC 7.0901
    39121410
  • UNSPSC 13.2
    39121410
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • ETIM 4.0
    EC000901
  • UNSPSC 11
    39121410
  • UNSPSC 12.01
    39121410
  • UNSPSC 20.0
    39121410

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

0441504 Phoenix Contact

Get a quick Quote!

Request a quote, and we will send you price within minutes.

Stock:

10

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 0441504 with other products

Height NS 35/7,5

Two conductors with the s...

Rated surge voltage

Open side panel

Insulating material group

China RoHS

Number of levels

ECLASS 9.0

ECLASS 10.0.1

Connection method

Two conductors with the s...

Number of connections

Flammability rating accor...

Temperature index of insu...

ECLASS 6.0

ETIM 3.0

UNSPSC 6.01

Static insulating materia...

Ambient temperature (asse...

ETIM 7.0

Maximum power dissipation...

ECLASS 11.0

ECLASS 7.0

UNSPSC 19.0

UNSPSC 18.0

Terminal block mounting

Specific optical density ...

Color

Overvoltage category

Surface flammability NFPA...

Insulating material

Degree of pollution

Relative insulation mater...

Note

Smoke gas toxicity NFPA 1...

Height NS 35/15

Conductor cross section s...

Conductor cross section f...

Conductor cross section f...

Permissible humidity (sto...

ECLASS 5.0

ECLASS 5.1

ETIM 6.0

Tightening torque, min

Conductor cross section f...

Fire protection for rail ...

Length

Tightening torque max

2 conductors with same cr...

2 conductors with same cr...

Conductor cross section A...

Conductor cross section f...

Operating temperature

Min. AWG conductor cross ...

Fire protection for rail ...

Fire protection for rail ...

Screw thread

Conductor cross section f...

2 conductors with same cr...

Conductor cross section s...

Connection in acc. with s...

Two conductors with the s...

Ambient temperature (stor...

ECLASS 4.0

Fire protection for rail ...

Height NS 32

Max. AWG conductor cross ...

Conductor cross section f...

UNSPSC 21.0

Stripping length

2 conductors with same cr...

Width

Conductor cross section A...

Nominal cross section

Calorimetric heat release...

Ambient temperature (actu...

ECLASS 4.1

ETIM 2.0

UNSPSC 7.0901

UNSPSC 13.2

Two conductors with the s...

ETIM 4.0

UNSPSC 11

UNSPSC 12.01

UNSPSC 20.0

Internal cylindrical gage

Maximum load current

Finger protection

Result of tight fit on su...

Short circuit stability r...

Result of surge voltage t...

Tensile test result

Tight fit on carrier

Conductor cross section s...

Nominal voltage UN

Power frequency withstand...

Bending test turns

Short-time current

Proof of thermal characte...

Shock protection test spe...

Result of flexion and pul...

Result of the test for me...

Setpoint

Result of temperature-ris...

Result of voltage-drop te...

Area of application

End cover width

Back of the hand protecti...

Potentials

Acceleration

Bending test conductor cr...

Test specification, oscil...

Shock form

Number of shocks per dire...

Result of power-frequency...

Test directions

Test specification, shock...

Oscillation, broadband no...

Test spectrum

Bending test rotation spe...

Shock test result

Shock duration

Requirement temperature-r...

Result of thermal test

Test frequency

Height

Nominal current IN

Test duration per axis

ASD level

Fuse

Cross section with insert...

Maximum load current (upp...

Fuse type

Actuatiing forces on plug...

Maximum power dissipation

Compatibitity between mod...

Nominal current IN (upper...

Testing the rated value o...

Cross section with insert...

Contact resistance

Testing the rated value o...

Selected product

0441504
10 in stock
0441504
Phoenix Contact

Ground modular terminal block, connection method: Screw connection, number of connections: 2, cross ...

Height NS 35/7,547 mm

Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum0.25 mm²

Rated surge voltage8 kV

Open side panelNo

Insulating material groupI

China RoHSEnvironmentally Friendly Use...

Number of levels1

ECLASS 9.027141141

ECLASS 10.0.127141141

Connection methodScrew connection

Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum1.5 mm²

Number of connections2

Flammability rating according to UL 94V0

Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))125 °C

ECLASS 6.027141100

ETIM 3.0EC000901

UNSPSC 6.0130211811

Static insulating material application in cold-60 °C

Ambient temperature (assembly)-5 °C ... 70 °C

ETIM 7.0EC000901

Maximum power dissipation for nominal condition1.02 W

ECLASS 11.027141141

ECLASS 7.027141141

UNSPSC 19.039121410

UNSPSC 18.039121410

Terminal block mounting0.6 Nm ... 0.8 Nm (PE foot w...

Specific optical density of smoke NFPA 130 (ASTM E 662)passed

Colorgreen-yellow

Overvoltage categoryIII

Surface flammability NFPA 130 (ASTM E 162)passed

Insulating materialPA

Degree of pollution3

Relative insulation material temperature index (Elec., UL 746 B)130 °C

NotePlease observe the current c...

Smoke gas toxicity NFPA 130 (SMP 800C)passed

Height NS 35/1554.5 mm

Conductor cross section solid min.0.2 mm²

Conductor cross section flexible min.0.2 mm²

Conductor cross section flexible, with ferrule without plastic sleeve max.4 mm²

Permissible humidity (storage/transport)30 % ... 70 %

ECLASS 5.027141100

ECLASS 5.127141100

ETIM 6.0EC000901

Tightening torque, min0.6 Nm

Conductor cross section flexible max.4 mm²

Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3

Length42.5 mm

Tightening torque max0.8 Nm

2 conductors with same cross section, solid min.0.2 mm²

2 conductors with same cross section, stranded max.1.5 mm²

Conductor cross section AWG min.24

Conductor cross section flexible, with ferrule with plastic sleeve min.0.25 mm²

Operating temperature-60 °C ... 105 °C (max. shor...

Min. AWG conductor cross section, flexible24

Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3

Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3

Screw threadM3

Conductor cross section flexible, with ferrule without plastic sleeve min.0.25 mm²

2 conductors with same cross section, stranded min.0.2 mm²

Conductor cross section solid max.4 mm²

Connection in acc. with standardCSA

Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum2.5 mm²

Ambient temperature (storage/transport)-25 °C ... 60 °C (for a shor...

ECLASS 4.027141100

Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Height NS 3252 mm

Max. AWG conductor cross section, flexible12

Conductor cross section flexible, with ferrule with plastic sleeve max.2.5 mm²

UNSPSC 21.039121410

Stripping length8 mm

2 conductors with same cross section, solid max.1.5 mm²

Width6.2 mm

Conductor cross section AWG max.12

Nominal cross section4 mm²

Calorimetric heat release NFPA 130 (ASTM E 1354)27,5 MJ/kg

Ambient temperature (actuation)-5 °C ... 70 °C

ECLASS 4.127141100

ETIM 2.0EC000901

UNSPSC 7.090139121410

UNSPSC 13.239121410

Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum0.5 mm²

ETIM 4.0EC000901

UNSPSC 1139121410

UNSPSC 12.0139121410

UNSPSC 20.039121410

Internal cylindrical gage-

Maximum load current-

Finger protection-

Result of tight fit on support-

Short circuit stability result-

Result of surge voltage test-

Tensile test result-

Tight fit on carrier-

Conductor cross section short circuit testing-

Nominal voltage UN-

Power frequency withstand voltage setpoint-

Bending test turns-

Short-time current-

Proof of thermal characteristics (needle flame) effective duration-

Shock protection test specification-

Result of flexion and pull-out test-

Result of the test for mechanical stability of terminal points (5 x conductor connection)-

Setpoint-

Result of temperature-rise test-

Result of voltage-drop test-

Area of application-

End cover width-

Back of the hand protection-

Potentials-

Acceleration-

Bending test conductor cross section/weight-

Test specification, oscillation, broadband noise-

Shock form-

Number of shocks per direction-

Result of power-frequency withstand voltage test-

Test directions-

Test specification, shock test-

Oscillation, broadband noise test result-

Test spectrum-

Bending test rotation speed-

Shock test result-

Shock duration-

Requirement temperature-rise test-

Result of thermal test-

Test frequency-

Height-

Nominal current IN-

Test duration per axis-

ASD level-

Fuse-

Cross section with insertion bridge, stranded max.-

Maximum load current (upper level)-

Fuse type-

Actuatiing forces on plug in or lever in fuse insert carriers-

Maximum power dissipation-

Compatibitity between modular fuse terminal block and fuse insert-

Nominal current IN (upper level)-

Testing the rated value of the power dissipation (exclusively short circuit protection)-

Cross section with insertion bridge, solid max.-

Contact resistance-

Testing the rated value of the power dissipation (overload and short circuit Protection)-

3044102
94 in stock
3044102
Phoenix Contact

Feed-through terminal block, nom. voltage: 1000 V, nominal current: 32 A, connection method: Screw c...

Height NS 35/7,547.5 mm

Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum0.14 mm²

Rated surge voltage8 kV

Open side panelYes

Insulating material groupI

China RoHSEnvironmentally Friendly Use...

Number of levels1

ECLASS 9.027141120

ECLASS 10.0.127141120

Connection methodScrew connection

Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum1.5 mm²

Number of connections2

Flammability rating according to UL 94V0

Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))125 °C

ECLASS 6.027141100

ETIM 3.0EC000897

UNSPSC 6.0130211811

Static insulating material application in cold-60 °C

Ambient temperature (assembly)-5 °C ... 70 °C

ETIM 7.0EC000897

Maximum power dissipation for nominal condition1.02 W

ECLASS 11.027141120

ECLASS 7.027141120

UNSPSC 19.039121410

UNSPSC 18.039121410

Terminal block mounting-

Specific optical density of smoke NFPA 130 (ASTM E 662)passed

Colorgray

Overvoltage categoryIII

Surface flammability NFPA 130 (ASTM E 162)passed

Insulating materialPA

Degree of pollution3

Relative insulation material temperature index (Elec., UL 746 B)130 °C

NoteNote: Product releases, conn...

Smoke gas toxicity NFPA 130 (SMP 800C)passed

Height NS 35/1555 mm

Conductor cross section solid min.0.14 mm²

Conductor cross section flexible min.0.14 mm²

Conductor cross section flexible, with ferrule without plastic sleeve max.4 mm²

Permissible humidity (storage/transport)30 % ... 70 %

ECLASS 5.027141100

ECLASS 5.127141100

ETIM 6.0EC000897

Tightening torque, min0.6 Nm

Conductor cross section flexible max.6 mm²

Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3

Length47.7 mm

Tightening torque max0.8 Nm

2 conductors with same cross section, solid min.0.14 mm²

2 conductors with same cross section, stranded max.1.5 mm²

Conductor cross section AWG min.26

Conductor cross section flexible, with ferrule with plastic sleeve min.0.14 mm²

Operating temperature-60 °C ... 105 °C (max. shor...

Min. AWG conductor cross section, flexible26

Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3

Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3

Screw threadM3

Conductor cross section flexible, with ferrule without plastic sleeve min.0.14 mm²

2 conductors with same cross section, stranded min.0.14 mm²

Conductor cross section solid max.6 mm²

Connection in acc. with standardCSA

Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum2.5 mm²

Ambient temperature (storage/transport)-25 °C ... 60 °C (for a shor...

ECLASS 4.027141100

Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Height NS 32-

Max. AWG conductor cross section, flexible10

Conductor cross section flexible, with ferrule with plastic sleeve max.4 mm²

UNSPSC 21.039121410

Stripping length9 mm

2 conductors with same cross section, solid max.1.5 mm²

Width6.2 mm

Conductor cross section AWG max.10

Nominal cross section4 mm²

Calorimetric heat release NFPA 130 (ASTM E 1354)27,5 MJ/kg

Ambient temperature (actuation)-5 °C ... 70 °C

ECLASS 4.127141100

ETIM 2.0EC000897

UNSPSC 7.090139121410

UNSPSC 13.239121410

Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum0.5 mm²

ETIM 4.0EC000897

UNSPSC 1139121410

UNSPSC 12.0139121410

UNSPSC 20.039121410

Internal cylindrical gageA4

Maximum load current41 A (with 6 mm² conductor c...

Finger protectionguaranteed

Result of tight fit on supportTest passed

Short circuit stability resultTest passed

Result of surge voltage testTest passed

Tensile test resultTest passed

Tight fit on carrierNS 35

Conductor cross section short circuit testing6 mm²

Nominal voltage UN1000 V

Power frequency withstand voltage setpoint2.2 kV

Bending test turns135

Short-time current0.72 kA

Proof of thermal characteristics (needle flame) effective duration30 s

Shock protection test specificationDIN EN 50274 (VDE 0660-514):...

Result of flexion and pull-out testTest passed

Result of the test for mechanical stability of terminal points (5 x conductor connection)Test passed

Setpoint1 N

Result of temperature-rise testTest passed

Result of voltage-drop testTest passed

Area of applicationRailway industry

End cover width2.2 mm

Back of the hand protectionguaranteed

Potentials1

Acceleration5g

Bending test conductor cross section/weight0.14 mm² / 0.2 kg

Test specification, oscillation, broadband noiseDIN EN 50155 (VDE 0115-200):...

Shock formHalf-sine

Number of shocks per direction3

Result of power-frequency withstand voltage testTest passed

Test directionsX-, Y- and Z-axis (pos. and ...

Test specification, shock testDIN EN 50155 (VDE 0115-200):...

Oscillation, broadband noise test resultTest passed

Test spectrumService life test category 1...

Bending test rotation speed10 rpm

Shock test resultTest passed

Shock duration30 ms

Requirement temperature-rise testIncrease in temperature ≤ 45...

Result of thermal testTest passed

Test frequencyf1 = 5 Hz to f2 = 150 Hz

Height46.9 mm

Nominal current IN32 A (with 4 mm² conductor c...

Test duration per axis5 h

ASD level1.857 (m/s2)2/Hz

Fuse-

Cross section with insertion bridge, stranded max.-

Maximum load current (upper level)-

Fuse type-

Actuatiing forces on plug in or lever in fuse insert carriers-

Maximum power dissipation-

Compatibitity between modular fuse terminal block and fuse insert-

Nominal current IN (upper level)-

Testing the rated value of the power dissipation (exclusively short circuit protection)-

Cross section with insertion bridge, solid max.-

Contact resistance-

Testing the rated value of the power dissipation (overload and short circuit Protection)-

3007217
25 in stock
3007217
Phoenix Contact

Fuse modular terminal block, fuse type: Glass / ceramics / ..., connection method: Screw connection,...

Height NS 35/7,579 mm

Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum0.25 mm²

Rated surge voltage6 kV

Open side panelNo

Insulating material groupI

China RoHSEnvironmentally Friendly Use...

Number of levels2

ECLASS 9.027141116

ECLASS 10.0.127141116

Connection methodScrew connection

Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum1.5 mm²

Number of connections4

Flammability rating according to UL 94V0

Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C

ECLASS 6.027141100

ETIM 3.0EC000899

UNSPSC 6.0130211811

Static insulating material application in cold-60 °C

Ambient temperature (assembly)-5 °C ... 70 °C

ETIM 7.0EC000899

Maximum power dissipation for nominal condition1.02 W (the value is multipl...

ECLASS 11.027141116

ECLASS 7.027141116

UNSPSC 19.039121410

UNSPSC 18.039121410

Terminal block mounting-

Specific optical density of smoke NFPA 130 (ASTM E 662)passed

Colorblack

Overvoltage categoryIII

Surface flammability NFPA 130 (ASTM E 162)passed

Insulating materialPA

Degree of pollution3

Relative insulation material temperature index (Elec., UL 746 B)130 °C

NoteIn the closed condition.

Smoke gas toxicity NFPA 130 (SMP 800C)passed

Height NS 35/1586.5 mm

Conductor cross section solid min.0.2 mm²

Conductor cross section flexible min.0.2 mm²

Conductor cross section flexible, with ferrule without plastic sleeve max.4 mm²

Permissible humidity (storage/transport)30 % ... 70 %

ECLASS 5.027141100

ECLASS 5.127141100

ETIM 6.0EC000899

Tightening torque, min0.5 Nm

Conductor cross section flexible max.4 mm²

Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3

Length86.5 mm

Tightening torque max0.8 Nm

2 conductors with same cross section, solid min.0.2 mm²

2 conductors with same cross section, stranded max.1.5 mm²

Conductor cross section AWG min.24

Conductor cross section flexible, with ferrule with plastic sleeve min.0.25 mm²

Operating temperature-60 °C ... 105 °C (max. shor...

Min. AWG conductor cross section, flexible-

Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3

Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3

Screw threadM3

Conductor cross section flexible, with ferrule without plastic sleeve min.0.25 mm²

2 conductors with same cross section, stranded min.0.2 mm²

Conductor cross section solid max.4 mm²

Connection in acc. with standardCSA

Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum1.5 mm²

Ambient temperature (storage/transport)-25 °C ... 60 °C (for a shor...

ECLASS 4.027141100

Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Height NS 3284 mm

Max. AWG conductor cross section, flexible-

Conductor cross section flexible, with ferrule with plastic sleeve max.4 mm²

UNSPSC 21.039121410

Stripping length8 mm

2 conductors with same cross section, solid max.1.5 mm²

Width8.2 mm

Conductor cross section AWG max.12

Nominal cross section4 mm²

Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg

Ambient temperature (actuation)-5 °C ... 70 °C

ECLASS 4.127141100

ETIM 2.0EC000897

UNSPSC 7.090139121410

UNSPSC 13.239121410

Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum0.5 mm²

ETIM 4.0EC000899

UNSPSC 1139121410

UNSPSC 12.0139121410

UNSPSC 20.039121410

Internal cylindrical gageA4

Maximum load current32 A (Lower level)

Finger protectionguaranteed

Result of tight fit on supportTest passed

Short circuit stability result-

Result of surge voltage testTest passed

Tensile test result-

Tight fit on carrier-

Conductor cross section short circuit testing-

Nominal voltage UN400 V

Power frequency withstand voltage setpoint-

Bending test turns135

Short-time current-

Proof of thermal characteristics (needle flame) effective duration-

Shock protection test specificationDIN EN 50274 (VDE 0660-514):...

Result of flexion and pull-out testTest passed

Result of the test for mechanical stability of terminal points (5 x conductor connection)Test passed

Setpoint-

Result of temperature-rise testTest passed

Result of voltage-drop test-

Area of application-

End cover width-

Back of the hand protectionguaranteed

Potentials-

Acceleration-

Bending test conductor cross section/weight0.2 mm² / 0.2 kg

Test specification, oscillation, broadband noise-

Shock form-

Number of shocks per direction-

Result of power-frequency withstand voltage testTest passed

Test directions-

Test specification, shock test-

Oscillation, broadband noise test result-

Test spectrum-

Bending test rotation speed-

Shock test result-

Shock duration-

Requirement temperature-rise test-

Result of thermal testTest passed

Test frequency-

Height-

Nominal current IN32 A

Test duration per axis-

ASD level-

FuseG / 6,3 x 32

Cross section with insertion bridge, stranded max.2.5 mm²

Maximum load current (upper level)10 A

Fuse typeGlass / ceramics / ...

Actuatiing forces on plug in or lever in fuse insert carriersTest passed

Maximum power dissipationmax. 2.5 W (with single arra...

Compatibitity between modular fuse terminal block and fuse insertTest passed

Nominal current IN (upper level)10 A

Testing the rated value of the power dissipation (exclusively short circuit protection)Test passed

Cross section with insertion bridge, solid max.4 mm²

Contact resistanceTest passed

Testing the rated value of the power dissipation (overload and short circuit Protection)Test passed

About the manufacturer

Phoenix Contact

Powermatic Associates is an authorized Phoenix Contact distributor, proudly offering a wide array of innovative industrial solutions that cater to modern technological demands. Phoenix Contact is a global leader renowned for its high-quality products in the fields of electrical engineering and automation technology. Their extensive catalog encompasses everything from connection technology, interface systems, and surge protection to automation software and control technology, making them a versatile choice for various industrial applications. At Powermatic Associates, we deliver Phoenix Contact’s pioneering connectivity and power management solutions, which include terminal blocks, connectors, relays, and PLCs. These components are essential for creating efficient and reliable electrical connections in diverse environments, ensuring seamless system integration. The company's comprehensive range of Industrial Internet of Things (IIoT) solutions facilitates intelligent networking, enabling customers to optimize their automation processes with cutting-edge technology. Phoenix Contact's emphasis on sustainability and innovation reflects in their energy management systems and renewable energy solutions. By incorporating these into your operations, you not only enhance efficiency but also contribute to sustainable practices, aligning with modern environmental standards. Powermatic Associates recognizes the significance of such advancements and partners with Phoenix Contact to provide expert engineering support and tailored solutions, helping you implement smart technologies that drive productivity and minimize costs. With a focus on safety and reliability, Phoenix Contact offers advanced surge protection devices and signal conditioners that safeguard your equipment against voltage spikes and ensure data integrity. In collaboration with Powermatic Associates, customers gain access to robust technical support and consultation, ensuring that every project benefits from personalized guidance and quick resolution of technical challenges. Our partnership extends the reach of Phoenix Contact’s globally recognized industrial automation products, including Human Machine Interfaces (HMIs) and Ethernet switches, empowering businesses with enhanced operational control and communication capabilities. Customers can trust Powermatic Associates to deliver prompt shipping and thorough assistance, ensuring that Phoenix Contact’s top-tier products are seamlessly integrated into their workflows for optimal performance.

Recently viewed products

Relevant products

FAQ

10 in stock

Ground modular terminal block, connection method: Screw connection, number of connections: 2, cross section: 0.2 mm² - 6 mm², AWG: 24 - 10, width: 6.2 mm, color: green-yellow, mounting type: NS 35/7,5, NS 35/15, NS 32

Similar products from: Terminal Blocks

What can I help you find today?

Recommended parts