2702383 Phoenix Contact Electrical Safety Devices

2702383 on Powermatic Associates
Phoenix Contact

Part#:2702383

Manufacturer:Phoenix Contact

Category:Electrical Safety Devices

Product Lifecycle:Active

25 in stock

Mar 14, 2025

Product description

Contact extension up to SILCL 3, Cat. 4, PL e in conjunction with suitable evaluation device, 5 enabling current paths, US = 24 V DC, pluggable Push-in terminal block

Product Details

  • Height
    116.6 mm
  • Max. permissible relative humidity (operation)
    75 % (on average, 85% infrequently, non-condensing)
  • Inrush current
    max. 100 mA
  • Filter time
    4 ms (at A1 in the event of voltage dips at Us)
  • Number of outputs
    1 (digital, PNP)
  • Switching capacity
    min. 50 mW
  • Output fuse
    10 A gL/gG
  • Voltage
    typ. 23 V DC (US - 1 V)
  • Typical response time at US
    < 50 ms
  • Recovery time
    < 100 ms
  • Nominal operating mode
    100% operating factor
  • Assembly instructions
    See derating curve
  • pluggable
    Yes
  • Conductor cross-section AWG
    24 ... 16
  • Rated insulation voltage
    250 V AC
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 5.1
    27371900
  • ETIM 7.0
    EC001449
  • UNSPSC 18.0
    39122205
  • Ambient temperature (storage/transport)
    -40 °C ... 80 °C
  • Maximum altitude
    max. 2000 m (Above sea level)
  • Rated control supply current IS
    typ. 80 mA
  • Protective circuit
    Surge protection Suppressor diode
  • Contact material
    AgSnO
  • Conductor cross-section flexible with ferrule without plastic sleeve
    0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
  • Stop category
    0
  • Safety Integrity Level (SIL)
    3 (In conjunction with suitable evaluating device)
  • Degree of pollution
    2
  • ECLASS 4.0
    40020600
  • ECLASS 4.1
    40020600
  • ECLASS 9.0
    27371819
  • UNSPSC 13.2
    39121501
  • UNSPSC 20.0
    39122205
  • Width
    17.5 mm
  • Max. permissible humidity (storage/transport)
    75 % (on average, 85% infrequently, non-condensing)
  • Power consumption at US
    typ. 1.92 W
  • Output description
    non-safety-related
  • Contact type
    1 confirmation current path
  • Limiting continuous current
    100 mA
  • Switching frequency
    max. 0.5 Hz
  • Current
    max. 100 mA
  • Maximum inrush current
    500 mA (Δt = 1 ms at Us)
  • Relay type
    Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
  • Degree of protection
    IP20
  • Connection method
    Push-in connection
  • Stripping length
    8 mm
  • Performance level (PL)
    e (In conjunction with suitable evaluating device)
  • Safety Integrity Level Claim Limit (SIL CL)
    3 (In conjunction with suitable evaluating device)
  • Overvoltage category
    III
  • ECLASS 10.0.1
    27371819
  • ECLASS 7.0
    27371819
  • ETIM 3.0
    EC001449
  • UNSPSC 21.0
    39122205
  • Depth
    114.5 mm
  • Designation
    Air clearances and creepage distances between the power circuits
  • Output name
    Confirmation current path
  • Switching voltage
    min. 5 V AC/DC
  • Sq. Total current
    64 A2 (observe derating)
  • Mechanical service life
    10x 106 cycles
  • Short-circuit protection
    Yes
  • Typical pickup time at US
    < 50 ms (when controlled via A1/A2)
  • Net weight
    210.1 g
  • Housing color
    yellow
  • Status display
    2 x green LEDs
  • Conductor cross section flexible
    0.2 mm² ... 1.5 mm²
  • Conductor cross-section flexible with ferrule and plastic sleeve
    0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
  • Standards/regulations
    DIN EN 50178
  • Rated surge voltage/insulation
    Basic insulation 4 kV between all current paths
  • Conformance
    CE-compliant
  • Vibration (operation)
    10 Hz ... 150 Hz, 2g (In the event of stress caused by vibration, contact reactions are possible for up to 1 ms.)
  • ECLASS 11.0
    27371819
  • ETIM 6.0
    EC001449
  • UNSPSC 19.0
    39122205
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Ambient temperature (operation)
    -20 °C ... 60 °C (observe derating)
  • Rated control circuit supply voltage US
    24 V DC -20 % / +25 %
  • Typical release time at US
    < 25 ms (when controlled via A1/A2)
  • Mounting position
    vertical or horizontal
  • Mounting type
    DIN rail mounting
  • Min. degree of protection of inst. location
    IP54
  • Conductor cross section solid
    0.2 mm² ... 1.5 mm²
  • Category
    4 (In conjunction with suitable evaluating device)
  • Shock
    15g (In the event of stress caused by shock, contact reactions are possible for up to 6 ms.)
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 5.0
    27371900
  • ECLASS 6.0
    27371800
  • ETIM 4.0
    EC001449

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

2702383 Phoenix Contact

Get a quick Quote!

Request a quote, and we will send you price within minutes.

Stock:

25

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 2702383 with other products

Height

Max. permissible relative humidity (operation)

Inrush current

Filter time

Number of outputs

Switching capacity

Output fuse

Voltage

Typical response time at US

Recovery time

Nominal operating mode

Assembly instructions

pluggable

Conductor cross-section AWG

Rated insulation voltage

China RoHS

ECLASS 5.1

ETIM 7.0

UNSPSC 18.0

Ambient temperature (storage/transport)

Maximum altitude

Rated control supply current IS

Protective circuit

Contact material

Conductor cross-section flexible with ferrule without plastic sleeve

Stop category

Safety Integrity Level (SIL)

Degree of pollution

ECLASS 4.0

ECLASS 4.1

ECLASS 9.0

UNSPSC 13.2

UNSPSC 20.0

Width

Max. permissible humidity (storage/transport)

Power consumption at US

Output description

Contact type

Limiting continuous current

Switching frequency

Current

Maximum inrush current

Relay type

Degree of protection

Connection method

Stripping length

Performance level (PL)

Safety Integrity Level Claim Limit (SIL CL)

Overvoltage category

ECLASS 10.0.1

ECLASS 7.0

ETIM 3.0

UNSPSC 21.0

Depth

Designation

Output name

Switching voltage

Sq. Total current

Mechanical service life

Short-circuit protection

Typical pickup time at US

Net weight

Housing color

Status display

Conductor cross section flexible

Conductor cross-section flexible with ferrule and plastic sleeve

Standards/regulations

Rated surge voltage/insulation

Conformance

Vibration (operation)

ECLASS 11.0

ETIM 6.0

UNSPSC 19.0

Utilization restriction

Ambient temperature (operation)

Rated control circuit supply voltage US

Typical release time at US

Mounting position

Mounting type

Min. degree of protection of inst. location

Conductor cross section solid

Category

Shock

REACh SVHC

ECLASS 5.0

ECLASS 6.0

ETIM 4.0

Typical input current at UN

Width

Max. permissible relative humidity (operation)

Typical release time

Concurrence

Protective circuit

Limiting continuous current

Relay type

Mounting position

Min. degree of protection of inst. location

pluggable

Designation

Category

Rated surge voltage/insulation

Depth

Input voltage range in reference to UN

Recovery time

Maximum switching voltage

Sq. Total current

Switching capacity min.

Nominal operating mode

Conductor cross section solid

Stripping length

Safety Integrity Level (SIL)

Overvoltage category

REACh SVHC

ECLASS 4.1

ETIM 7.0

UNSPSC 13.2

Ambient temperature (storage/transport)

Nominal input voltage UN

Operating voltage display

Contact material

Maximum inrush current

Mechanical service life

Net weight

Connection method

Stop category

Standards/regulations

Shock

ECLASS 10.0.1

ECLASS 5.0

ECLASS 9.0

UNSPSC 11

UNSPSC 7.0901

UNSPSC 19.0

Utilization restriction

Ambient temperature (operation)

Maximum altitude

Typical response time

Status display

Minimum switching voltage

Maximum interrupting rating (inductive load)

Output fuse

Mounting type

Housing color

Conductor cross-section AWG

Screw thread

Performance level (PL)

Degree of pollution

Vibration (operation)

ECLASS 4.0

ECLASS 6.0

ETIM 6.0

UNSPSC 12.01

UNSPSC 21.0

Height

Max. permissible humidity (storage/transport)

Voltage at input/start and feedback circuit

Max. permissible overall conductor resistance

Contact type

Inrush current, minimum

Interrupting rating (ohmic load) max.

Switching capacity (360/h cycles)

Degree of protection

Conductor cross section flexible

Safety Integrity Level Claim Limit (SIL CL)

Rated insulation voltage

China RoHS

ECLASS 5.1

ETIM 4.0

ETIM 3.0

UNSPSC 18.0

ECLASS 11.0

ECLASS 7.0

UNSPSC 6.01

UNSPSC 20.0

Height

Max. permissible relative humidity (operation)

Rated control circuit supply voltage US

Width

Maximum altitude

Max. permissible humidity (storage/transport)

Inrush current

Description of the input

Input current range "0" signal

Nominal output voltage

Leakage current

Max. inductive load

Output voltage range

Response time

Housing color

Ambient temperature (storage/transport)

Designation

Input name

Protective circuit

Protective circuit/component

Cable length

Limiting continuous current

Output voltage when switched off

Maximum inrush current

Cycle time

Assembly instructions

Degree of protection

Status display

Conductor cross-section AWG

Stop category

Conformance

ECLASS 11.0

Ambient temperature (operation)

Rated control supply current IS

Input voltage range "1" signal

Output name

Ohmic load

Switching frequency

Discharging circuit

Restart time

Mounting type

Connection method

Stripping length

Performance level (PL)

Overvoltage category

China RoHS

Depth

Current consumption

Power consumption at US

Number of inputs

Max. permissible overall conductor resistance

Number of outputs

Max. capacitive load

Short-circuit protection

Voltage

Nominal voltage range

Housing material

Protection class

Conductor cross section solid

pluggable

Standards/regulations

Vibration (operation)

ECLASS 9.0

Filter time

Input voltage range "0" signal

Output description

Nominal output voltage range

Test pulses

Error detection time at 1-channel structure

Net weight

Nominal operating mode

Min. degree of protection of inst. location

Conductor cross section flexible

Safety Integrity Level (SIL)

Rated surge voltage/insulation

Shock

Mounting position

Operating voltage display

Indication

Safety Integrity Level Claim Limit (SIL CL)

Rated insulation voltage

Degree of pollution

ECLASS 10.0.1

Selected product

2702383
25 in stock
2702383
Phoenix Contact

Contact extension up to SILCL 3, Cat. 4, PL e in conjunction with suitable evaluation device, 5 enab...

Height116.6 mm

Max. permissible relative humidity (operation)75 % (on average, 85% infrequently, non-condensing)

Inrush currentmax. 100 mA

Filter time4 ms (at A1 in the event of voltage dips at Us)

Number of outputs1 (digital, PNP)

Switching capacitymin. 50 mW

Output fuse10 A gL/gG

Voltagetyp. 23 V DC (US - 1 V)

Typical response time at US< 50 ms

Recovery time< 100 ms

Nominal operating mode100% operating factor

Assembly instructionsSee derating curve

pluggableYes

Conductor cross-section AWG24 ... 16

Rated insulation voltage250 V AC

China RoHSEnvironmentally Friendly Use Period = 50 years

ECLASS 5.127371900

ETIM 7.0EC001449

UNSPSC 18.039122205

Ambient temperature (storage/transport)-40 °C ... 80 °C

Maximum altitudemax. 2000 m (Above sea level)

Rated control supply current IStyp. 80 mA

Protective circuitSurge protection Suppressor diode

Contact materialAgSnO

Conductor cross-section flexible with ferrule without plastic sleeve0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)

Stop category0

Safety Integrity Level (SIL)3 (In conjunction with suitable evaluating device)

Degree of pollution2

ECLASS 4.040020600

ECLASS 4.140020600

ECLASS 9.027371819

UNSPSC 13.239121501

UNSPSC 20.039122205

Width17.5 mm

Max. permissible humidity (storage/transport)75 % (on average, 85% infrequently, non-condensing)

Power consumption at UStyp. 1.92 W

Output descriptionnon-safety-related

Contact type1 confirmation current path

Limiting continuous current100 mA

Switching frequencymax. 0.5 Hz

Currentmax. 100 mA

Maximum inrush current500 mA (Δt = 1 ms at Us)

Relay typeElectromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3

Degree of protectionIP20

Connection methodPush-in connection

Stripping length8 mm

Performance level (PL)e (In conjunction with suitable evaluating device)

Safety Integrity Level Claim Limit (SIL CL)3 (In conjunction with suitable evaluating device)

Overvoltage categoryIII

ECLASS 10.0.127371819

ECLASS 7.027371819

ETIM 3.0EC001449

UNSPSC 21.039122205

Depth114.5 mm

DesignationAir clearances and creepage distances between the power circuits

Output nameConfirmation current path

Switching voltagemin. 5 V AC/DC

Sq. Total current64 A2 (observe derating)

Mechanical service life10x 106 cycles

Short-circuit protectionYes

Typical pickup time at US< 50 ms (when controlled via A1/A2)

Net weight210.1 g

Housing coloryellow

Status display2 x green LEDs

Conductor cross section flexible0.2 mm² ... 1.5 mm²

Conductor cross-section flexible with ferrule and plastic sleeve0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)

Standards/regulationsDIN EN 50178

Rated surge voltage/insulationBasic insulation 4 kV between all current paths

ConformanceCE-compliant

Vibration (operation)10 Hz ... 150 Hz, 2g (In the event of stress caused by vibration, contact reactions are possible for up to 1 ms.)

ECLASS 11.027371819

ETIM 6.0EC001449

UNSPSC 19.039122205

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Ambient temperature (operation)-20 °C ... 60 °C (observe derating)

Rated control circuit supply voltage US24 V DC -20 % / +25 %

Typical release time at US< 25 ms (when controlled via A1/A2)

Mounting positionvertical or horizontal

Mounting typeDIN rail mounting

Min. degree of protection of inst. locationIP54

Conductor cross section solid0.2 mm² ... 1.5 mm²

Category4 (In conjunction with suitable evaluating device)

Shock15g (In the event of stress caused by shock, contact reactions are possible for up to 6 ms.)

REACh SVHCLead 7439-92-1

ECLASS 5.027371900

ECLASS 6.027371800

ETIM 4.0EC001449

Typical input current at UN-

Width-

Max. permissible relative humidity (operation)-

Typical release time-

Concurrence-

Protective circuit-

Limiting continuous current-

Relay type-

Mounting position-

Min. degree of protection of inst. location-

pluggable-

Designation-

Category-

Rated surge voltage/insulation-

Depth-

Input voltage range in reference to UN-

Recovery time-

Maximum switching voltage-

Sq. Total current-

Switching capacity min.-

Nominal operating mode-

Conductor cross section solid-

Stripping length-

Safety Integrity Level (SIL)-

Overvoltage category-

REACh SVHC-

ECLASS 4.1-

ETIM 7.0-

UNSPSC 13.2-

Ambient temperature (storage/transport)-

Nominal input voltage UN-

Operating voltage display-

Contact material-

Maximum inrush current-

Mechanical service life-

Net weight-

Connection method-

Stop category-

Standards/regulations-

Shock-

ECLASS 10.0.1-

ECLASS 5.0-

ECLASS 9.0-

UNSPSC 11-

UNSPSC 7.0901-

UNSPSC 19.0-

Utilization restriction-

Ambient temperature (operation)-

Maximum altitude-

Typical response time-

Status display-

Minimum switching voltage-

Maximum interrupting rating (inductive load)-

Output fuse-

Mounting type-

Housing color-

Conductor cross-section AWG-

Screw thread-

Performance level (PL)-

Degree of pollution-

Vibration (operation)-

ECLASS 4.0-

ECLASS 6.0-

ETIM 6.0-

UNSPSC 12.01-

UNSPSC 21.0-

Height-

Max. permissible humidity (storage/transport)-

Voltage at input/start and feedback circuit-

Max. permissible overall conductor resistance-

Contact type-

Inrush current, minimum-

Interrupting rating (ohmic load) max.-

Switching capacity (360/h cycles)-

Degree of protection-

Conductor cross section flexible-

Safety Integrity Level Claim Limit (SIL CL)-

Rated insulation voltage-

China RoHS-

ECLASS 5.1-

ETIM 4.0-

ETIM 3.0-

UNSPSC 18.0-

ECLASS 11.0-

ECLASS 7.0-

UNSPSC 6.01-

UNSPSC 20.0-

Height-

Max. permissible relative humidity (operation)-

Rated control circuit supply voltage US-

Width-

Maximum altitude-

Max. permissible humidity (storage/transport)-

Inrush current-

Description of the input-

Input current range "0" signal-

Nominal output voltage-

Leakage current-

Max. inductive load-

Output voltage range-

Response time-

Housing color-

Ambient temperature (storage/transport)-

Designation-

Input name-

Protective circuit-

Protective circuit/component-

Cable length-

Limiting continuous current-

Output voltage when switched off-

Maximum inrush current-

Cycle time-

Assembly instructions-

Degree of protection-

Status display-

Conductor cross-section AWG-

Stop category-

Conformance-

ECLASS 11.0-

Ambient temperature (operation)-

Rated control supply current IS-

Input voltage range "1" signal-

Output name-

Ohmic load-

Switching frequency-

Discharging circuit-

Restart time-

Mounting type-

Connection method-

Stripping length-

Performance level (PL)-

Overvoltage category-

China RoHS-

Depth-

Current consumption-

Power consumption at US-

Number of inputs-

Max. permissible overall conductor resistance-

Number of outputs-

Max. capacitive load-

Short-circuit protection-

Voltage-

Nominal voltage range-

Housing material-

Protection class-

Conductor cross section solid-

pluggable-

Standards/regulations-

Vibration (operation)-

ECLASS 9.0-

Filter time-

Input voltage range "0" signal-

Output description-

Nominal output voltage range-

Test pulses-

Error detection time at 1-channel structure-

Net weight-

Nominal operating mode-

Min. degree of protection of inst. location-

Conductor cross section flexible-

Safety Integrity Level (SIL)-

Rated surge voltage/insulation-

Shock-

Mounting position-

Operating voltage display-

Indication-

Safety Integrity Level Claim Limit (SIL CL)-

Rated insulation voltage-

Degree of pollution-

ECLASS 10.0.1-

2900509
2 in stock
2900509
Phoenix Contact

Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat. 4, PL e according to ...

Height-

Max. permissible relative humidity (operation)-

Inrush current-

Filter time-

Number of outputs-

Switching capacity-

Output fuse-

Voltage-

Typical response time at US-

Recovery time-

Nominal operating mode-

Assembly instructions-

pluggable-

Conductor cross-section AWG-

Rated insulation voltage-

China RoHS-

ECLASS 5.1-

ETIM 7.0-

UNSPSC 18.0-

Ambient temperature (storage/transport)-

Maximum altitude-

Rated control supply current IS-

Protective circuit-

Contact material-

Conductor cross-section flexible with ferrule without plastic sleeve-

Stop category-

Safety Integrity Level (SIL)-

Degree of pollution-

ECLASS 4.0-

ECLASS 4.1-

ECLASS 9.0-

UNSPSC 13.2-

UNSPSC 20.0-

Width-

Max. permissible humidity (storage/transport)-

Power consumption at US-

Output description-

Contact type-

Limiting continuous current-

Switching frequency-

Current-

Maximum inrush current-

Relay type-

Degree of protection-

Connection method-

Stripping length-

Performance level (PL)-

Safety Integrity Level Claim Limit (SIL CL)-

Overvoltage category-

ECLASS 10.0.1-

ECLASS 7.0-

ETIM 3.0-

UNSPSC 21.0-

Depth-

Designation-

Output name-

Switching voltage-

Sq. Total current-

Mechanical service life-

Short-circuit protection-

Typical pickup time at US-

Net weight-

Housing color-

Status display-

Conductor cross section flexible-

Conductor cross-section flexible with ferrule and plastic sleeve-

Standards/regulations-

Rated surge voltage/insulation-

Conformance-

Vibration (operation)-

ECLASS 11.0-

ETIM 6.0-

UNSPSC 19.0-

Utilization restriction-

Ambient temperature (operation)-

Rated control circuit supply voltage US-

Typical release time at US-

Mounting position-

Mounting type-

Min. degree of protection of inst. location-

Conductor cross section solid-

Category-

Shock-

REACh SVHC-

ECLASS 5.0-

ECLASS 6.0-

ETIM 4.0-

Typical input current at UN140 mA AC

Width22.5 mm

Max. permissible relative humidity (operation)75 % (on average, 85% infrequently, non-condensing)

Typical release time45 ms (single-channel)

Concurrence

Protective circuitSurge protection Suppressor diode

Limiting continuous current6 A (N/O contact)

Relay typeElectromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3

Mounting positionany

Min. degree of protection of inst. locationIP54

pluggableYes

DesignationAir clearances and creepage distances between the power circuits

Category4

Rated surge voltage/insulation4 kV / Basic isolation, (safe isolation, reinforced insulation and 6 kV between input circuit and enabling current paths.)

Depth114.5 mm

Input voltage range in reference to UN0.85 ... 1.1

Recovery time1 s

Maximum switching voltage250 V AC/DC

Sq. Total current72 A2 (ITH2 = I12 + I22 + I32)

Switching capacity min.100 mW

Nominal operating mode100% operating factor

Conductor cross section solid0.2 mm² ... 2.5 mm²

Stripping length7 mm

Safety Integrity Level (SIL)3

Overvoltage categoryIII

REACh SVHCLead 7439-92-1

ECLASS 4.140020600

ETIM 7.0EC001449

UNSPSC 13.239121501

Ambient temperature (storage/transport)-40 °C ... 70 °C

Nominal input voltage UN24 V AC/DC

Operating voltage displayGreen LED

Contact materialAgSnO2, + 0.2 µm Au

Maximum inrush current6 A

Mechanical service lifeapprox. 107 cycles

Net weight137.48 g

Connection methodScrew connection

Stop category0

Standards/regulationsDIN EN 50178/VDE 0160

Shock15g

ECLASS 10.0.127371819

ECLASS 5.027371900

ECLASS 9.027371819

UNSPSC 1139121501

UNSPSC 7.090139121501

UNSPSC 19.039122205

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Ambient temperature (operation)-20 °C ... 55 °C

Maximum altitude≤ 2000 m (Above sea level)

Typical response time20 ms (man. start)

Status displayGreen LED

Minimum switching voltage10 V AC/DC

Maximum interrupting rating (inductive load)48 W (24 V DC, τ = 40 ms)

Output fuse10 A gL/gG NEOZED (N/O contact)

Mounting typeDIN rail mounting

Housing coloryellow

Conductor cross-section AWG24 ... 12

Screw threadM3

Performance level (PL)e

Degree of pollution2

Vibration (operation)10 Hz ... 150 Hz, 2g

ECLASS 4.040020600

ECLASS 6.027371800

ETIM 6.0EC001449

UNSPSC 12.0139121501

UNSPSC 21.039122205

Height99 mm

Max. permissible humidity (storage/transport)75 % (on average, 85% infrequently, non-condensing)

Voltage at input/start and feedback circuitapprox. 24 V DC

Max. permissible overall conductor resistanceapprox. 50 Ω (Input and start circuits at UN)

Contact type3 enabling current paths

Inrush current, minimum10 mA

Interrupting rating (ohmic load) max.144 W (24 V DC, τ = 0 ms)

Switching capacity (360/h cycles)6 A (24 V DC)

Degree of protectionIP20

Conductor cross section flexible0.2 mm² ... 2.5 mm²

Safety Integrity Level Claim Limit (SIL CL)3

Rated insulation voltage250 V

China RoHSEnvironmentally Friendly Use Period = 50 years

ECLASS 5.127371900

ETIM 4.0EC001449

ETIM 3.0EC001449

UNSPSC 18.039122205

ECLASS 11.027371819

ECLASS 7.027371819

UNSPSC 6.0130211901

UNSPSC 20.039122205

Height-

Max. permissible relative humidity (operation)-

Rated control circuit supply voltage US-

Width-

Maximum altitude-

Max. permissible humidity (storage/transport)-

Inrush current-

Description of the input-

Input current range "0" signal-

Nominal output voltage-

Leakage current-

Max. inductive load-

Output voltage range-

Response time-

Housing color-

Ambient temperature (storage/transport)-

Designation-

Input name-

Protective circuit-

Protective circuit/component-

Cable length-

Limiting continuous current-

Output voltage when switched off-

Maximum inrush current-

Cycle time-

Assembly instructions-

Degree of protection-

Status display-

Conductor cross-section AWG-

Stop category-

Conformance-

ECLASS 11.0-

Ambient temperature (operation)-

Rated control supply current IS-

Input voltage range "1" signal-

Output name-

Ohmic load-

Switching frequency-

Discharging circuit-

Restart time-

Mounting type-

Connection method-

Stripping length-

Performance level (PL)-

Overvoltage category-

China RoHS-

Depth-

Current consumption-

Power consumption at US-

Number of inputs-

Max. permissible overall conductor resistance-

Number of outputs-

Max. capacitive load-

Short-circuit protection-

Voltage-

Nominal voltage range-

Housing material-

Protection class-

Conductor cross section solid-

pluggable-

Standards/regulations-

Vibration (operation)-

ECLASS 9.0-

Filter time-

Input voltage range "0" signal-

Output description-

Nominal output voltage range-

Test pulses-

Error detection time at 1-channel structure-

Net weight-

Nominal operating mode-

Min. degree of protection of inst. location-

Conductor cross section flexible-

Safety Integrity Level (SIL)-

Rated surge voltage/insulation-

Shock-

Mounting position-

Operating voltage display-

Indication-

Safety Integrity Level Claim Limit (SIL CL)-

Rated insulation voltage-

Degree of pollution-

ECLASS 10.0.1-

1104975
4 in stock
1104975
Phoenix Contact

Configurable safety module (basic module), 8 safe inputs, 4 safe outputs, 4 reset inputs or 4 signal...

Height-

Max. permissible relative humidity (operation)-

Inrush current-

Filter time-

Number of outputs-

Switching capacity-

Output fuse-

Voltage-

Typical response time at US-

Recovery time-

Nominal operating mode-

Assembly instructions-

pluggable-

Conductor cross-section AWG-

Rated insulation voltage-

China RoHS-

ECLASS 5.1-

ETIM 7.0-

UNSPSC 18.0-

Ambient temperature (storage/transport)-

Maximum altitude-

Rated control supply current IS-

Protective circuit-

Contact material-

Conductor cross-section flexible with ferrule without plastic sleeve-

Stop category-

Safety Integrity Level (SIL)-

Degree of pollution-

ECLASS 4.0-

ECLASS 4.1-

ECLASS 9.0-

UNSPSC 13.2-

UNSPSC 20.0-

Width-

Max. permissible humidity (storage/transport)-

Power consumption at US-

Output description-

Contact type-

Limiting continuous current-

Switching frequency-

Current-

Maximum inrush current-

Relay type-

Degree of protection-

Connection method-

Stripping length-

Performance level (PL)-

Safety Integrity Level Claim Limit (SIL CL)-

Overvoltage category-

ECLASS 10.0.1-

ECLASS 7.0-

ETIM 3.0-

UNSPSC 21.0-

Depth-

Designation-

Output name-

Switching voltage-

Sq. Total current-

Mechanical service life-

Short-circuit protection-

Typical pickup time at US-

Net weight-

Housing color-

Status display-

Conductor cross section flexible-

Conductor cross-section flexible with ferrule and plastic sleeve-

Standards/regulations-

Rated surge voltage/insulation-

Conformance-

Vibration (operation)-

ECLASS 11.0-

ETIM 6.0-

UNSPSC 19.0-

Utilization restriction-

Ambient temperature (operation)-

Rated control circuit supply voltage US-

Typical release time at US-

Mounting position-

Mounting type-

Min. degree of protection of inst. location-

Conductor cross section solid-

Category-

Shock-

REACh SVHC-

ECLASS 5.0-

ECLASS 6.0-

ETIM 4.0-

Typical input current at UN-

Width-

Max. permissible relative humidity (operation)-

Typical release time-

Concurrence-

Protective circuit-

Limiting continuous current-

Relay type-

Mounting position-

Min. degree of protection of inst. location-

pluggable-

Designation-

Category-

Rated surge voltage/insulation-

Depth-

Input voltage range in reference to UN-

Recovery time-

Maximum switching voltage-

Sq. Total current-

Switching capacity min.-

Nominal operating mode-

Conductor cross section solid-

Stripping length-

Safety Integrity Level (SIL)-

Overvoltage category-

REACh SVHC-

ECLASS 4.1-

ETIM 7.0-

UNSPSC 13.2-

Ambient temperature (storage/transport)-

Nominal input voltage UN-

Operating voltage display-

Contact material-

Maximum inrush current-

Mechanical service life-

Net weight-

Connection method-

Stop category-

Standards/regulations-

Shock-

ECLASS 10.0.1-

ECLASS 5.0-

ECLASS 9.0-

UNSPSC 11-

UNSPSC 7.0901-

UNSPSC 19.0-

Utilization restriction-

Ambient temperature (operation)-

Maximum altitude-

Typical response time-

Status display-

Minimum switching voltage-

Maximum interrupting rating (inductive load)-

Output fuse-

Mounting type-

Housing color-

Conductor cross-section AWG-

Screw thread-

Performance level (PL)-

Degree of pollution-

Vibration (operation)-

ECLASS 4.0-

ECLASS 6.0-

ETIM 6.0-

UNSPSC 12.01-

UNSPSC 21.0-

Height-

Max. permissible humidity (storage/transport)-

Voltage at input/start and feedback circuit-

Max. permissible overall conductor resistance-

Contact type-

Inrush current, minimum-

Interrupting rating (ohmic load) max.-

Switching capacity (360/h cycles)-

Degree of protection-

Conductor cross section flexible-

Safety Integrity Level Claim Limit (SIL CL)-

Rated insulation voltage-

China RoHS-

ECLASS 5.1-

ETIM 4.0-

ETIM 3.0-

UNSPSC 18.0-

ECLASS 11.0-

ECLASS 7.0-

UNSPSC 6.01-

UNSPSC 20.0-

Height107.74 mm

Max. permissible relative humidity (operation)95 % (non-condensing)

Rated control circuit supply voltage US24 V DC -20 % / +20 % (provide external protection, typically 5 A)

Width22.61 mm

Maximum altitude≤ 2000 m (Above sea level)

Max. permissible humidity (storage/transport)95 % (non-condensing)

Inrush currentmax. 600 mA (Δt < 10 ms)

Description of the inputconfigurable (as signal output or reset input)

Input current range "0" signal< 1 mA

Nominal output voltage24 V DC (Supply via A1)

Leakage currentmax. 100 µA

Max. inductive loadmax. 2.4 mH

Output voltage range18.2 V DC ... 27.8 V DC (US - 1 V)

Response timesee user manual

Housing coloryellow

Ambient temperature (storage/transport)-20 °C ... 85 °C

DesignationAir clearances and creepage distances between the power circuits

Input nameReset inputs

Protective circuitSerial protection against polarity reversal

Protective circuit/componentSuppressor diode

Cable lengthmax. 100 m (per output)

Limiting continuous current100 mA (per channel)

Output voltage when switched offmax. 0.1 V

Maximum inrush current1.1 A (Δt = 3 s  at Us)

Cycle timesee user manual

Assembly instructionsObserve derating

Degree of protectionIP20

Status display1 x LED (green), 1 x LED (orange), 1 x LED (blue)

Conductor cross-section AWG24 ... 16

Stop category0

ConformanceCE-compliant

ECLASS 11.027371819

Ambient temperature (operation)-10 °C ... 55 °C (observe derating)

Rated control supply current IStyp. 55 mA (Outputs inactive)

Input voltage range "1" signal11 V DC ... 28.8 V DC

Output nameO1, O2, O3, O4

Ohmic loadmin. 50 Ω (Observe limiting continuous current)

Switching frequencymax. 1/4 x tCycle [Hz]

Discharging circuitYes, internal

Restart timemin. 5 s (Boot time)

Mounting typeDIN rail mounting

Connection methodPush-in connection

Stripping length10 mm

Performance level (PL)e (2-channel wiring)

Overvoltage categoryII

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e

Depth113.6 mm

Current consumptiontyp. 12 mA (typically with US)

Power consumption at UStyp. 1.32 W (Outputs inactive)

Number of inputs4

Max. permissible overall conductor resistance1.2 kΩ (Input and reset circuit at US)

Number of outputs4

Max. capacitive loadmax. 470 nF

Short-circuit protectionYes (self-limitation at 1.1 A)

Voltage24 V DC (via A1)

Nominal voltage range18.2 V DC ... 27.8 V DC (US - 1 V)

Housing materialPolyamide PA non-reinforced

Protection classIII (EN 50178)

Conductor cross section solid0.2 mm² ... 2.5 mm²

pluggableYes

Standards/regulationsEN 50178

Vibration (operation)10 Hz ... 150 Hz, 2g

ECLASS 9.027371819

Filter time250 ms ±2 ms (Test pulse rate > 500 ms)

Input voltage range "0" signal0 V DC ... 5 V DC

Output descriptionPNP, IEC 61131-2 Typ 0,1

Nominal output voltage range18.5 V DC ... 28.1 V DC (US - 0,7 V)

Test pulses≤ 200 µs (Test pulse duration)

Error detection time at 1-channel structure< 3.5 s (OFF state)

Net weight141 g

Nominal operating mode100% operating factor

Min. degree of protection of inst. locationIP54

Conductor cross section flexible0.2 mm² ... 2.5 mm²

Safety Integrity Level (SIL)2

Rated surge voltage/insulationBasic insulation 4 kV between all current paths and housing

Shock10g for Δt = 16 ms (continuous shock, 1000 shocks in each space direction)

Mounting positionvertical or horizontal

Operating voltage display1 x green LED

Indication2 x LED (red)

Safety Integrity Level Claim Limit (SIL CL)3 (2-channel wiring)

Rated insulation voltage250 V AC

Degree of pollution2

ECLASS 10.0.127371819

About the manufacturer

Phoenix Contact

Powermatic Associates is an authorized Phoenix Contact distributor, proudly offering a wide array of innovative industrial solutions that cater to modern technological demands. Phoenix Contact is a global leader renowned for its high-quality products in the fields of electrical engineering and automation technology. Their extensive catalog encompasses everything from connection technology, interface systems, and surge protection to automation software and control technology, making them a versatile choice for various industrial applications. At Powermatic Associates, we deliver Phoenix Contact’s pioneering connectivity and power management solutions, which include terminal blocks, connectors, relays, and PLCs. These components are essential for creating efficient and reliable electrical connections in diverse environments, ensuring seamless system integration. The company's comprehensive range of Industrial Internet of Things (IIoT) solutions facilitates intelligent networking, enabling customers to optimize their automation processes with cutting-edge technology. Phoenix Contact's emphasis on sustainability and innovation reflects in their energy management systems and renewable energy solutions. By incorporating these into your operations, you not only enhance efficiency but also contribute to sustainable practices, aligning with modern environmental standards. Powermatic Associates recognizes the significance of such advancements and partners with Phoenix Contact to provide expert engineering support and tailored solutions, helping you implement smart technologies that drive productivity and minimize costs. With a focus on safety and reliability, Phoenix Contact offers advanced surge protection devices and signal conditioners that safeguard your equipment against voltage spikes and ensure data integrity. In collaboration with Powermatic Associates, customers gain access to robust technical support and consultation, ensuring that every project benefits from personalized guidance and quick resolution of technical challenges. Our partnership extends the reach of Phoenix Contact’s globally recognized industrial automation products, including Human Machine Interfaces (HMIs) and Ethernet switches, empowering businesses with enhanced operational control and communication capabilities. Customers can trust Powermatic Associates to deliver prompt shipping and thorough assistance, ensuring that Phoenix Contact’s top-tier products are seamlessly integrated into their workflows for optimal performance.

About the Product Category

Devices for electrical safety are tools or equipment engineered to guard against electrical risks and safeguard individuals, property, and equipment from possible threats linked to electricity. These devices are utilized in both industrial and residential settings to guarantee the secure usage and handling of electrical systems.

Electrical Safety Devices

Recently viewed products

Relevant products

FAQ

25 in stock

Contact extension up to SILCL 3, Cat. 4, PL e in conjunction with suitable evaluation device, 5 enabling current paths, US = 24 V DC, pluggable Push-in terminal block

Similar products from: Electrical Safety Devices

What can I help you find today?

Recommended parts