Product description

Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat. 4, PL e according to EN ISO 13849, single or two-channel operation, 3 enabling current paths, nominal input voltage of 24 V AC/DC, plug-in screw terminal blocks

Product Details

  • Typical input current at UN
    140 mA AC
  • Width
    22.5 mm
  • Max. permissible relative humidity (operation)
    75 % (on average, 85% infrequently, non-condensing)
  • Typical release time
    45 ms (single-channel)
  • Concurrence
  • Protective circuit
    Surge protection Suppressor diode
  • Limiting continuous current
    6 A (N/O contact)
  • Relay type
    Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
  • Mounting position
    any
  • Min. degree of protection of inst. location
    IP54
  • pluggable
    Yes
  • Designation
    Air clearances and creepage distances between the power circuits
  • Category
    4
  • Rated surge voltage/insulation
    4 kV / Basic isolation, (safe isolation, reinforced insulation and 6 kV between input circuit and enabling current paths.)
  • Depth
    114.5 mm
  • Input voltage range in reference to UN
    0.85 ... 1.1
  • Recovery time
    1 s
  • Maximum switching voltage
    250 V AC/DC
  • Sq. Total current
    72 A2 (ITH2 = I12 + I22 + I32)
  • Switching capacity min.
    100 mW
  • Nominal operating mode
    100% operating factor
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Stripping length
    7 mm
  • Safety Integrity Level (SIL)
    3
  • Overvoltage category
    III
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.1
    40020600
  • ETIM 7.0
    EC001449
  • UNSPSC 13.2
    39121501
  • Ambient temperature (storage/transport)
    -40 °C ... 70 °C
  • Nominal input voltage UN
    24 V AC/DC
  • Operating voltage display
    Green LED
  • Contact material
    AgSnO2, + 0.2 µm Au
  • Maximum inrush current
    6 A
  • Mechanical service life
    approx. 107 cycles
  • Net weight
    137.48 g
  • Connection method
    Screw connection
  • Stop category
    0
  • Standards/regulations
    DIN EN 50178/VDE 0160
  • Shock
    15g
  • ECLASS 10.0.1
    27371819
  • ECLASS 5.0
    27371900
  • ECLASS 9.0
    27371819
  • UNSPSC 11
    39121501
  • UNSPSC 7.0901
    39121501
  • UNSPSC 19.0
    39122205
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Ambient temperature (operation)
    -20 °C ... 55 °C
  • Maximum altitude
    ≤ 2000 m (Above sea level)
  • Typical response time
    20 ms (man. start)
  • Status display
    Green LED
  • Minimum switching voltage
    10 V AC/DC
  • Maximum interrupting rating (inductive load)
    48 W (24 V DC, τ = 40 ms)
  • Output fuse
    10 A gL/gG NEOZED (N/O contact)
  • Mounting type
    DIN rail mounting
  • Housing color
    yellow
  • Conductor cross-section AWG
    24 ... 12
  • Screw thread
    M3
  • Performance level (PL)
    e
  • Degree of pollution
    2
  • Vibration (operation)
    10 Hz ... 150 Hz, 2g
  • ECLASS 4.0
    40020600
  • ECLASS 6.0
    27371800
  • ETIM 6.0
    EC001449
  • UNSPSC 12.01
    39121501
  • UNSPSC 21.0
    39122205
  • Height
    99 mm
  • Max. permissible humidity (storage/transport)
    75 % (on average, 85% infrequently, non-condensing)
  • Voltage at input/start and feedback circuit
    approx. 24 V DC
  • Max. permissible overall conductor resistance
    approx. 50 Ω (Input and start circuits at UN)
  • Contact type
    3 enabling current paths
  • Inrush current, minimum
    10 mA
  • Interrupting rating (ohmic load) max.
    144 W (24 V DC, τ = 0 ms)
  • Switching capacity (360/h cycles)
    6 A (24 V DC)
  • Degree of protection
    IP20
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Safety Integrity Level Claim Limit (SIL CL)
    3
  • Rated insulation voltage
    250 V
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 5.1
    27371900
  • ETIM 4.0
    EC001449
  • ETIM 3.0
    EC001449
  • UNSPSC 18.0
    39122205
  • ECLASS 11.0
    27371819
  • ECLASS 7.0
    27371819
  • UNSPSC 6.01
    30211901
  • UNSPSC 20.0
    39122205

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

2900509 Phoenix Contact

Get a quick Quote!

Request a quote, and we will send you price within minutes.

Stock:

2

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 2900509 with other products

Typical input current at UN

Width

Max. permissible relative humidity (operation)

Typical release time

Concurrence

Protective circuit

Limiting continuous current

Relay type

Mounting position

Min. degree of protection of inst. location

pluggable

Designation

Category

Rated surge voltage/insulation

Depth

Input voltage range in reference to UN

Recovery time

Maximum switching voltage

Sq. Total current

Switching capacity min.

Nominal operating mode

Conductor cross section solid

Stripping length

Safety Integrity Level (SIL)

Overvoltage category

REACh SVHC

ECLASS 4.1

ETIM 7.0

UNSPSC 13.2

Ambient temperature (storage/transport)

Nominal input voltage UN

Operating voltage display

Contact material

Maximum inrush current

Mechanical service life

Net weight

Connection method

Stop category

Standards/regulations

Shock

ECLASS 10.0.1

ECLASS 5.0

ECLASS 9.0

UNSPSC 11

UNSPSC 7.0901

UNSPSC 19.0

Utilization restriction

Ambient temperature (operation)

Maximum altitude

Typical response time

Status display

Minimum switching voltage

Maximum interrupting rating (inductive load)

Output fuse

Mounting type

Housing color

Conductor cross-section AWG

Screw thread

Performance level (PL)

Degree of pollution

Vibration (operation)

ECLASS 4.0

ECLASS 6.0

ETIM 6.0

UNSPSC 12.01

UNSPSC 21.0

Height

Max. permissible humidity (storage/transport)

Voltage at input/start and feedback circuit

Max. permissible overall conductor resistance

Contact type

Inrush current, minimum

Interrupting rating (ohmic load) max.

Switching capacity (360/h cycles)

Degree of protection

Conductor cross section flexible

Safety Integrity Level Claim Limit (SIL CL)

Rated insulation voltage

China RoHS

ECLASS 5.1

ETIM 4.0

ETIM 3.0

UNSPSC 18.0

ECLASS 11.0

ECLASS 7.0

UNSPSC 6.01

UNSPSC 20.0

Height

Max. permissible relative humidity (operation)

Inrush current

Filter time

Number of outputs

Switching capacity

Output fuse

Voltage

Typical response time at US

Recovery time

Nominal operating mode

Assembly instructions

pluggable

Conductor cross-section AWG

Rated insulation voltage

China RoHS

ECLASS 5.1

ETIM 7.0

UNSPSC 18.0

Ambient temperature (storage/transport)

Maximum altitude

Rated control supply current IS

Protective circuit

Contact material

Conductor cross-section flexible with ferrule without plastic sleeve

Stop category

Safety Integrity Level (SIL)

Degree of pollution

ECLASS 4.0

ECLASS 4.1

ECLASS 9.0

UNSPSC 13.2

UNSPSC 20.0

Width

Max. permissible humidity (storage/transport)

Power consumption at US

Output description

Contact type

Limiting continuous current

Switching frequency

Current

Maximum inrush current

Relay type

Degree of protection

Connection method

Stripping length

Performance level (PL)

Safety Integrity Level Claim Limit (SIL CL)

Overvoltage category

ECLASS 10.0.1

ECLASS 7.0

ETIM 3.0

UNSPSC 21.0

Depth

Designation

Output name

Switching voltage

Sq. Total current

Mechanical service life

Short-circuit protection

Typical pickup time at US

Net weight

Housing color

Status display

Conductor cross section flexible

Conductor cross-section flexible with ferrule and plastic sleeve

Standards/regulations

Rated surge voltage/insulation

Conformance

Vibration (operation)

ECLASS 11.0

ETIM 6.0

UNSPSC 19.0

Utilization restriction

Ambient temperature (operation)

Rated control circuit supply voltage US

Typical release time at US

Mounting position

Mounting type

Min. degree of protection of inst. location

Conductor cross section solid

Category

Shock

REACh SVHC

ECLASS 5.0

ECLASS 6.0

ETIM 4.0

Flammability rating according to UL 94

China RoHS

ECLASS 4.1

ETIM 2.0

ETIM 7.0

UNSPSC 12.01

UNSPSC 19.0

Designation

ECLASS 10.0.1

ECLASS 7.0

UNSPSC 6.01

UNSPSC 21.0

Width

Depth

Degree of protection

Ambient temperature (operation)

Typical input current at UN

Typical release time

Operating voltage display

Contact type

Contact material

ECLASS 11.0

ECLASS 6.0

ETIM 3.0

UNSPSC 11

UNSPSC 20.0

Utilization restriction

Height

Ambient temperature (storage/transport)

Nominal input voltage UN

Typical response time

Protective circuit

Power dissipation for nominal condition

Type of switch contact

Maximum switching voltage

Mounting position

Limiting continuous current

Operating mode

Connection name

Screw thread

Standards/regulations

Identification

ECLASS 5.0

ECLASS 4.0

ECLASS 9.0

ETIM 4.0

UNSPSC 13.2

Connection method

Conductor cross section flexible

Min. switching current

Test voltage

Mechanical service life

Conductor cross section solid

UNSPSC 18.0

ETIM 6.0

Maximum inrush current

Note

Stripping length

Conductor cross section AWG

Pollution degree

REACh SVHC

Minimum switching voltage

Interrupting rating (ohmic load) max.

Switching capacity

Assembly instructions

Connection in acc. with standard

Overvoltage category

ECLASS 5.1

UNSPSC 7.0901

Selected product

2900509
2 in stock
2900509
Phoenix Contact

Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat. 4, PL e according to ...

Typical input current at UN140 mA AC

Width22.5 mm

Max. permissible relative humidity (operation)75 % (on average, 85% infrequently, non-condensing)

Typical release time45 ms (single-channel)

Concurrence

Protective circuitSurge protection Suppressor diode

Limiting continuous current6 A (N/O contact)

Relay typeElectromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3

Mounting positionany

Min. degree of protection of inst. locationIP54

pluggableYes

DesignationAir clearances and creepage distances between the power circuits

Category4

Rated surge voltage/insulation4 kV / Basic isolation, (safe isolation, reinforced insulation and 6 kV between input circuit and enabling current paths.)

Depth114.5 mm

Input voltage range in reference to UN0.85 ... 1.1

Recovery time1 s

Maximum switching voltage250 V AC/DC

Sq. Total current72 A2 (ITH2 = I12 + I22 + I32)

Switching capacity min.100 mW

Nominal operating mode100% operating factor

Conductor cross section solid0.2 mm² ... 2.5 mm²

Stripping length7 mm

Safety Integrity Level (SIL)3

Overvoltage categoryIII

REACh SVHCLead 7439-92-1

ECLASS 4.140020600

ETIM 7.0EC001449

UNSPSC 13.239121501

Ambient temperature (storage/transport)-40 °C ... 70 °C

Nominal input voltage UN24 V AC/DC

Operating voltage displayGreen LED

Contact materialAgSnO2, + 0.2 µm Au

Maximum inrush current6 A

Mechanical service lifeapprox. 107 cycles

Net weight137.48 g

Connection methodScrew connection

Stop category0

Standards/regulationsDIN EN 50178/VDE 0160

Shock15g

ECLASS 10.0.127371819

ECLASS 5.027371900

ECLASS 9.027371819

UNSPSC 1139121501

UNSPSC 7.090139121501

UNSPSC 19.039122205

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Ambient temperature (operation)-20 °C ... 55 °C

Maximum altitude≤ 2000 m (Above sea level)

Typical response time20 ms (man. start)

Status displayGreen LED

Minimum switching voltage10 V AC/DC

Maximum interrupting rating (inductive load)48 W (24 V DC, τ = 40 ms)

Output fuse10 A gL/gG NEOZED (N/O contact)

Mounting typeDIN rail mounting

Housing coloryellow

Conductor cross-section AWG24 ... 12

Screw threadM3

Performance level (PL)e

Degree of pollution2

Vibration (operation)10 Hz ... 150 Hz, 2g

ECLASS 4.040020600

ECLASS 6.027371800

ETIM 6.0EC001449

UNSPSC 12.0139121501

UNSPSC 21.039122205

Height99 mm

Max. permissible humidity (storage/transport)75 % (on average, 85% infrequently, non-condensing)

Voltage at input/start and feedback circuitapprox. 24 V DC

Max. permissible overall conductor resistanceapprox. 50 Ω (Input and start circuits at UN)

Contact type3 enabling current paths

Inrush current, minimum10 mA

Interrupting rating (ohmic load) max.144 W (24 V DC, τ = 0 ms)

Switching capacity (360/h cycles)6 A (24 V DC)

Degree of protectionIP20

Conductor cross section flexible0.2 mm² ... 2.5 mm²

Safety Integrity Level Claim Limit (SIL CL)3

Rated insulation voltage250 V

China RoHSEnvironmentally Friendly Use Period = 50 years

ECLASS 5.127371900

ETIM 4.0EC001449

ETIM 3.0EC001449

UNSPSC 18.039122205

ECLASS 11.027371819

ECLASS 7.027371819

UNSPSC 6.0130211901

UNSPSC 20.039122205

Height-

Max. permissible relative humidity (operation)-

Inrush current-

Filter time-

Number of outputs-

Switching capacity-

Output fuse-

Voltage-

Typical response time at US-

Recovery time-

Nominal operating mode-

Assembly instructions-

pluggable-

Conductor cross-section AWG-

Rated insulation voltage-

China RoHS-

ECLASS 5.1-

ETIM 7.0-

UNSPSC 18.0-

Ambient temperature (storage/transport)-

Maximum altitude-

Rated control supply current IS-

Protective circuit-

Contact material-

Conductor cross-section flexible with ferrule without plastic sleeve-

Stop category-

Safety Integrity Level (SIL)-

Degree of pollution-

ECLASS 4.0-

ECLASS 4.1-

ECLASS 9.0-

UNSPSC 13.2-

UNSPSC 20.0-

Width-

Max. permissible humidity (storage/transport)-

Power consumption at US-

Output description-

Contact type-

Limiting continuous current-

Switching frequency-

Current-

Maximum inrush current-

Relay type-

Degree of protection-

Connection method-

Stripping length-

Performance level (PL)-

Safety Integrity Level Claim Limit (SIL CL)-

Overvoltage category-

ECLASS 10.0.1-

ECLASS 7.0-

ETIM 3.0-

UNSPSC 21.0-

Depth-

Designation-

Output name-

Switching voltage-

Sq. Total current-

Mechanical service life-

Short-circuit protection-

Typical pickup time at US-

Net weight-

Housing color-

Status display-

Conductor cross section flexible-

Conductor cross-section flexible with ferrule and plastic sleeve-

Standards/regulations-

Rated surge voltage/insulation-

Conformance-

Vibration (operation)-

ECLASS 11.0-

ETIM 6.0-

UNSPSC 19.0-

Utilization restriction-

Ambient temperature (operation)-

Rated control circuit supply voltage US-

Typical release time at US-

Mounting position-

Mounting type-

Min. degree of protection of inst. location-

Conductor cross section solid-

Category-

Shock-

REACh SVHC-

ECLASS 5.0-

ECLASS 6.0-

ETIM 4.0-

Flammability rating according to UL 94-

China RoHS-

ECLASS 4.1-

ETIM 2.0-

ETIM 7.0-

UNSPSC 12.01-

UNSPSC 19.0-

Designation-

ECLASS 10.0.1-

ECLASS 7.0-

UNSPSC 6.01-

UNSPSC 21.0-

Width-

Depth-

Degree of protection-

Ambient temperature (operation)-

Typical input current at UN-

Typical release time-

Operating voltage display-

Contact type-

Contact material-

ECLASS 11.0-

ECLASS 6.0-

ETIM 3.0-

UNSPSC 11-

UNSPSC 20.0-

Utilization restriction-

Height-

Ambient temperature (storage/transport)-

Nominal input voltage UN-

Typical response time-

Protective circuit-

Power dissipation for nominal condition-

Type of switch contact-

Maximum switching voltage-

Mounting position-

Limiting continuous current-

Operating mode-

Connection name-

Screw thread-

Standards/regulations-

Identification-

ECLASS 5.0-

ECLASS 4.0-

ECLASS 9.0-

ETIM 4.0-

UNSPSC 13.2-

Connection method-

Conductor cross section flexible-

Min. switching current-

Test voltage-

Mechanical service life-

Conductor cross section solid-

UNSPSC 18.0-

ETIM 6.0-

Maximum inrush current-

Note-

Stripping length-

Conductor cross section AWG-

Pollution degree-

REACh SVHC-

Minimum switching voltage-

Interrupting rating (ohmic load) max.-

Switching capacity-

Assembly instructions-

Connection in acc. with standard-

Overvoltage category-

ECLASS 5.1-

UNSPSC 7.0901-

2702383
25 in stock
2702383
Phoenix Contact

Contact extension up to SILCL 3, Cat. 4, PL e in conjunction with suitable evaluation device, 5 enab...

Typical input current at UN-

Width-

Max. permissible relative humidity (operation)-

Typical release time-

Concurrence-

Protective circuit-

Limiting continuous current-

Relay type-

Mounting position-

Min. degree of protection of inst. location-

pluggable-

Designation-

Category-

Rated surge voltage/insulation-

Depth-

Input voltage range in reference to UN-

Recovery time-

Maximum switching voltage-

Sq. Total current-

Switching capacity min.-

Nominal operating mode-

Conductor cross section solid-

Stripping length-

Safety Integrity Level (SIL)-

Overvoltage category-

REACh SVHC-

ECLASS 4.1-

ETIM 7.0-

UNSPSC 13.2-

Ambient temperature (storage/transport)-

Nominal input voltage UN-

Operating voltage display-

Contact material-

Maximum inrush current-

Mechanical service life-

Net weight-

Connection method-

Stop category-

Standards/regulations-

Shock-

ECLASS 10.0.1-

ECLASS 5.0-

ECLASS 9.0-

UNSPSC 11-

UNSPSC 7.0901-

UNSPSC 19.0-

Utilization restriction-

Ambient temperature (operation)-

Maximum altitude-

Typical response time-

Status display-

Minimum switching voltage-

Maximum interrupting rating (inductive load)-

Output fuse-

Mounting type-

Housing color-

Conductor cross-section AWG-

Screw thread-

Performance level (PL)-

Degree of pollution-

Vibration (operation)-

ECLASS 4.0-

ECLASS 6.0-

ETIM 6.0-

UNSPSC 12.01-

UNSPSC 21.0-

Height-

Max. permissible humidity (storage/transport)-

Voltage at input/start and feedback circuit-

Max. permissible overall conductor resistance-

Contact type-

Inrush current, minimum-

Interrupting rating (ohmic load) max.-

Switching capacity (360/h cycles)-

Degree of protection-

Conductor cross section flexible-

Safety Integrity Level Claim Limit (SIL CL)-

Rated insulation voltage-

China RoHS-

ECLASS 5.1-

ETIM 4.0-

ETIM 3.0-

UNSPSC 18.0-

ECLASS 11.0-

ECLASS 7.0-

UNSPSC 6.01-

UNSPSC 20.0-

Height116.6 mm

Max. permissible relative humidity (operation)75 % (on average, 85% infrequently, non-condensing)

Inrush currentmax. 100 mA

Filter time4 ms (at A1 in the event of voltage dips at Us)

Number of outputs1 (digital, PNP)

Switching capacitymin. 50 mW

Output fuse10 A gL/gG

Voltagetyp. 23 V DC (US - 1 V)

Typical response time at US< 50 ms

Recovery time< 100 ms

Nominal operating mode100% operating factor

Assembly instructionsSee derating curve

pluggableYes

Conductor cross-section AWG24 ... 16

Rated insulation voltage250 V AC

China RoHSEnvironmentally Friendly Use Period = 50 years

ECLASS 5.127371900

ETIM 7.0EC001449

UNSPSC 18.039122205

Ambient temperature (storage/transport)-40 °C ... 80 °C

Maximum altitudemax. 2000 m (Above sea level)

Rated control supply current IStyp. 80 mA

Protective circuitSurge protection Suppressor diode

Contact materialAgSnO

Conductor cross-section flexible with ferrule without plastic sleeve0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)

Stop category0

Safety Integrity Level (SIL)3 (In conjunction with suitable evaluating device)

Degree of pollution2

ECLASS 4.040020600

ECLASS 4.140020600

ECLASS 9.027371819

UNSPSC 13.239121501

UNSPSC 20.039122205

Width17.5 mm

Max. permissible humidity (storage/transport)75 % (on average, 85% infrequently, non-condensing)

Power consumption at UStyp. 1.92 W

Output descriptionnon-safety-related

Contact type1 confirmation current path

Limiting continuous current100 mA

Switching frequencymax. 0.5 Hz

Currentmax. 100 mA

Maximum inrush current500 mA (Δt = 1 ms at Us)

Relay typeElectromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3

Degree of protectionIP20

Connection methodPush-in connection

Stripping length8 mm

Performance level (PL)e (In conjunction with suitable evaluating device)

Safety Integrity Level Claim Limit (SIL CL)3 (In conjunction with suitable evaluating device)

Overvoltage categoryIII

ECLASS 10.0.127371819

ECLASS 7.027371819

ETIM 3.0EC001449

UNSPSC 21.039122205

Depth114.5 mm

DesignationAir clearances and creepage distances between the power circuits

Output nameConfirmation current path

Switching voltagemin. 5 V AC/DC

Sq. Total current64 A2 (observe derating)

Mechanical service life10x 106 cycles

Short-circuit protectionYes

Typical pickup time at US< 50 ms (when controlled via A1/A2)

Net weight210.1 g

Housing coloryellow

Status display2 x green LEDs

Conductor cross section flexible0.2 mm² ... 1.5 mm²

Conductor cross-section flexible with ferrule and plastic sleeve0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)

Standards/regulationsDIN EN 50178

Rated surge voltage/insulationBasic insulation 4 kV between all current paths

ConformanceCE-compliant

Vibration (operation)10 Hz ... 150 Hz, 2g (In the event of stress caused by vibration, contact reactions are possible for up to 1 ms.)

ECLASS 11.027371819

ETIM 6.0EC001449

UNSPSC 19.039122205

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Ambient temperature (operation)-20 °C ... 60 °C (observe derating)

Rated control circuit supply voltage US24 V DC -20 % / +25 %

Typical release time at US< 25 ms (when controlled via A1/A2)

Mounting positionvertical or horizontal

Mounting typeDIN rail mounting

Min. degree of protection of inst. locationIP54

Conductor cross section solid0.2 mm² ... 1.5 mm²

Category4 (In conjunction with suitable evaluating device)

Shock15g (In the event of stress caused by shock, contact reactions are possible for up to 6 ms.)

REACh SVHCLead 7439-92-1

ECLASS 5.027371900

ECLASS 6.027371800

ETIM 4.0EC001449

Flammability rating according to UL 94-

China RoHS-

ECLASS 4.1-

ETIM 2.0-

ETIM 7.0-

UNSPSC 12.01-

UNSPSC 19.0-

Designation-

ECLASS 10.0.1-

ECLASS 7.0-

UNSPSC 6.01-

UNSPSC 21.0-

Width-

Depth-

Degree of protection-

Ambient temperature (operation)-

Typical input current at UN-

Typical release time-

Operating voltage display-

Contact type-

Contact material-

ECLASS 11.0-

ECLASS 6.0-

ETIM 3.0-

UNSPSC 11-

UNSPSC 20.0-

Utilization restriction-

Height-

Ambient temperature (storage/transport)-

Nominal input voltage UN-

Typical response time-

Protective circuit-

Power dissipation for nominal condition-

Type of switch contact-

Maximum switching voltage-

Mounting position-

Limiting continuous current-

Operating mode-

Connection name-

Screw thread-

Standards/regulations-

Identification-

ECLASS 5.0-

ECLASS 4.0-

ECLASS 9.0-

ETIM 4.0-

UNSPSC 13.2-

Connection method-

Conductor cross section flexible-

Min. switching current-

Test voltage-

Mechanical service life-

Conductor cross section solid-

UNSPSC 18.0-

ETIM 6.0-

Maximum inrush current-

Note-

Stripping length-

Conductor cross section AWG-

Pollution degree-

REACh SVHC-

Minimum switching voltage-

Interrupting rating (ohmic load) max.-

Switching capacity-

Assembly instructions-

Connection in acc. with standard-

Overvoltage category-

ECLASS 5.1-

UNSPSC 7.0901-

2966265
3 in stock
2966265
Phoenix Contact

PLC-INTERFACE, consisting of PLC-BSC.../21 basic terminal block with screw connection and plug-in mi...

Typical input current at UN-

Width-

Max. permissible relative humidity (operation)-

Typical release time-

Concurrence-

Protective circuit-

Limiting continuous current-

Relay type-

Mounting position-

Min. degree of protection of inst. location-

pluggable-

Designation-

Category-

Rated surge voltage/insulation-

Depth-

Input voltage range in reference to UN-

Recovery time-

Maximum switching voltage-

Sq. Total current-

Switching capacity min.-

Nominal operating mode-

Conductor cross section solid-

Stripping length-

Safety Integrity Level (SIL)-

Overvoltage category-

REACh SVHC-

ECLASS 4.1-

ETIM 7.0-

UNSPSC 13.2-

Ambient temperature (storage/transport)-

Nominal input voltage UN-

Operating voltage display-

Contact material-

Maximum inrush current-

Mechanical service life-

Net weight-

Connection method-

Stop category-

Standards/regulations-

Shock-

ECLASS 10.0.1-

ECLASS 5.0-

ECLASS 9.0-

UNSPSC 11-

UNSPSC 7.0901-

UNSPSC 19.0-

Utilization restriction-

Ambient temperature (operation)-

Maximum altitude-

Typical response time-

Status display-

Minimum switching voltage-

Maximum interrupting rating (inductive load)-

Output fuse-

Mounting type-

Housing color-

Conductor cross-section AWG-

Screw thread-

Performance level (PL)-

Degree of pollution-

Vibration (operation)-

ECLASS 4.0-

ECLASS 6.0-

ETIM 6.0-

UNSPSC 12.01-

UNSPSC 21.0-

Height-

Max. permissible humidity (storage/transport)-

Voltage at input/start and feedback circuit-

Max. permissible overall conductor resistance-

Contact type-

Inrush current, minimum-

Interrupting rating (ohmic load) max.-

Switching capacity (360/h cycles)-

Degree of protection-

Conductor cross section flexible-

Safety Integrity Level Claim Limit (SIL CL)-

Rated insulation voltage-

China RoHS-

ECLASS 5.1-

ETIM 4.0-

ETIM 3.0-

UNSPSC 18.0-

ECLASS 11.0-

ECLASS 7.0-

UNSPSC 6.01-

UNSPSC 20.0-

Height-

Max. permissible relative humidity (operation)-

Inrush current-

Filter time-

Number of outputs-

Switching capacity-

Output fuse-

Voltage-

Typical response time at US-

Recovery time-

Nominal operating mode-

Assembly instructions-

pluggable-

Conductor cross-section AWG-

Rated insulation voltage-

China RoHS-

ECLASS 5.1-

ETIM 7.0-

UNSPSC 18.0-

Ambient temperature (storage/transport)-

Maximum altitude-

Rated control supply current IS-

Protective circuit-

Contact material-

Conductor cross-section flexible with ferrule without plastic sleeve-

Stop category-

Safety Integrity Level (SIL)-

Degree of pollution-

ECLASS 4.0-

ECLASS 4.1-

ECLASS 9.0-

UNSPSC 13.2-

UNSPSC 20.0-

Width-

Max. permissible humidity (storage/transport)-

Power consumption at US-

Output description-

Contact type-

Limiting continuous current-

Switching frequency-

Current-

Maximum inrush current-

Relay type-

Degree of protection-

Connection method-

Stripping length-

Performance level (PL)-

Safety Integrity Level Claim Limit (SIL CL)-

Overvoltage category-

ECLASS 10.0.1-

ECLASS 7.0-

ETIM 3.0-

UNSPSC 21.0-

Depth-

Designation-

Output name-

Switching voltage-

Sq. Total current-

Mechanical service life-

Short-circuit protection-

Typical pickup time at US-

Net weight-

Housing color-

Status display-

Conductor cross section flexible-

Conductor cross-section flexible with ferrule and plastic sleeve-

Standards/regulations-

Rated surge voltage/insulation-

Conformance-

Vibration (operation)-

ECLASS 11.0-

ETIM 6.0-

UNSPSC 19.0-

Utilization restriction-

Ambient temperature (operation)-

Rated control circuit supply voltage US-

Typical release time at US-

Mounting position-

Mounting type-

Min. degree of protection of inst. location-

Conductor cross section solid-

Category-

Shock-

REACh SVHC-

ECLASS 5.0-

ECLASS 6.0-

ETIM 4.0-

Flammability rating according to UL 94V0 (Housing)

China RoHSEnvironmentally Friendly Use Period = 50 years

ECLASS 4.127371100

ETIM 2.0EC001437

ETIM 7.0EC001437

UNSPSC 12.0139121515

UNSPSC 19.039122334

DesignationCorrosive gas test

ECLASS 10.0.127371601

ECLASS 7.027371601

UNSPSC 6.0130211916

UNSPSC 21.039122334

Width6.2 mm

Depth94 mm

Degree of protectionIP20 (Relay base)

Ambient temperature (operation)-40 °C ... 60 °C

Typical input current at UN9 mA

Typical release time8 ms

Operating voltage displayYellow LED

Contact type1 changeover contact

Contact materialAgSnO, hard gold-plated

ECLASS 11.027371601

ECLASS 6.027371600

ETIM 3.0EC001437

UNSPSC 1139121515

UNSPSC 20.039122334

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Height80 mm

Ambient temperature (storage/transport)-40 °C ... 85 °C

Nominal input voltage UN24 V DC

Typical response time5 ms

Protective circuitReverse polarity protection Polarity protection diode

Power dissipation for nominal condition0.22 W

Type of switch contactSingle contact

Maximum switching voltage250 V AC/DC

Mounting positionany

Limiting continuous current6 A

Operating mode100% operating factor

Connection nameContact side

Screw threadM3

Standards/regulationsIEC 60664

IdentificationISA-S71.04. G3 Harsh Group

ECLASS 5.027371600

ECLASS 4.027371100

ECLASS 9.027371601

ETIM 4.0EC001437

UNSPSC 13.239122334

Connection methodScrew connection

Conductor cross section flexible0.14 mm² ... 2.5 mm²

Min. switching current10 mA (at 12 V)

Test voltage4 kV AC (50 Hz, 1 min., winding/contact)

Mechanical service life2x 107 cycles

Conductor cross section solid0.14 mm² ... 2.5 mm²

UNSPSC 18.039122334

ETIM 6.0EC001437

Maximum inrush current50 mA

Notethe following values are applicable if a gold layer is destroyed

Stripping length8 mm

Conductor cross section AWG26 ... 14

Pollution degree3

REACh SVHCLead 7439-92-1

Minimum switching voltage5 V (at 100 mA)

Interrupting rating (ohmic load) max.140 W (at 24 V DC)

Switching capacity2 A (at 24 V, DC13)

Assembly instructionsIn rows with zero spacing

Connection in acc. with standardCUL

Overvoltage categoryIII

ECLASS 5.127371600

UNSPSC 7.090139121515

About the manufacturer

Phoenix Contact

Powermatic Associates is an authorized Phoenix Contact distributor, proudly offering a wide array of innovative industrial solutions that cater to modern technological demands. Phoenix Contact is a global leader renowned for its high-quality products in the fields of electrical engineering and automation technology. Their extensive catalog encompasses everything from connection technology, interface systems, and surge protection to automation software and control technology, making them a versatile choice for various industrial applications. At Powermatic Associates, we deliver Phoenix Contact’s pioneering connectivity and power management solutions, which include terminal blocks, connectors, relays, and PLCs. These components are essential for creating efficient and reliable electrical connections in diverse environments, ensuring seamless system integration. The company's comprehensive range of Industrial Internet of Things (IIoT) solutions facilitates intelligent networking, enabling customers to optimize their automation processes with cutting-edge technology. Phoenix Contact's emphasis on sustainability and innovation reflects in their energy management systems and renewable energy solutions. By incorporating these into your operations, you not only enhance efficiency but also contribute to sustainable practices, aligning with modern environmental standards. Powermatic Associates recognizes the significance of such advancements and partners with Phoenix Contact to provide expert engineering support and tailored solutions, helping you implement smart technologies that drive productivity and minimize costs. With a focus on safety and reliability, Phoenix Contact offers advanced surge protection devices and signal conditioners that safeguard your equipment against voltage spikes and ensure data integrity. In collaboration with Powermatic Associates, customers gain access to robust technical support and consultation, ensuring that every project benefits from personalized guidance and quick resolution of technical challenges. Our partnership extends the reach of Phoenix Contact’s globally recognized industrial automation products, including Human Machine Interfaces (HMIs) and Ethernet switches, empowering businesses with enhanced operational control and communication capabilities. Customers can trust Powermatic Associates to deliver prompt shipping and thorough assistance, ensuring that Phoenix Contact’s top-tier products are seamlessly integrated into their workflows for optimal performance.

About the Product Category

Devices for electrical safety are tools or equipment engineered to guard against electrical risks and safeguard individuals, property, and equipment from possible threats linked to electricity. These devices are utilized in both industrial and residential settings to guarantee the secure usage and handling of electrical systems.

Electrical Safety Devices

Recently viewed products

Relevant products

FAQ

2 in stock

Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat. 4, PL e according to EN ISO 13849, single or two-channel operation, 3 enabling current paths, nominal input voltage of 24 V AC/DC, plug-in screw terminal blocks

Similar products from: Electrical Safety Devices

What can I help you find today?

Recommended parts