Product description

Feed-through terminal block with bolt connection method, cross section: 0.1 - 6 mm², AWG: 26 - 10, width 9 mm, color: gray

Product Details

  • Nominal cross section
    4 mm²
  • Rated surge voltage
    8 kV
  • Degree of pollution
    3
  • Power frequency withstand voltage setpoint
    2 kV
  • Result of tight fit on support
    Test passed
  • Short circuit stability result
    Test passed
  • ASD level
    1.857 (m/s2)2/Hz
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • End cover width
    2.2 mm
  • Height NS 32
    52.1 mm
  • Max. cross section for cable lug connection
    2.5 mm²
  • Hole diameter, min.
    4.3 mm
  • Tightening torque, min
    1.2 Nm
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • Number of connections
    2
  • Insulating material group
    I
  • Nominal current IN
    32 A
  • Result of surge voltage test
    Test passed
  • Setpoint
    1 N
  • Result of thermal test
    Test passed
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • Test duration per axis
    5 h
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Length
    53.3 mm
  • Connection
    1 level
  • Cable lug connection according to standard
    DIN 46237:1970-07
  • Min. cross section for cable lug connection
    0.5 mm²
  • Cable lug width, max.
    8 mm
  • Tightening torque max
    1.4 Nm
  • ECLASS 4.0
    27141100
  • Color
    gray
  • Overvoltage category
    III
  • Maximum power dissipation for nominal condition
    1.02 W
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Result of temperature-rise test
    Test passed
  • Short-time current
    0.48 kA
  • Test spectrum
    Service life test category 1, class B, body mounted
  • Shock test result
    Test passed
  • Shock form
    Half-sine
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Height NS 35/7,5
    47.1 mm
  • Connection method
    Bolt connection
  • Number of levels
    1
  • Insulating material
    PA
  • Maximum load current
    32 A
  • Open side panel
    Yes
  • Tight fit on carrier
    NS 35/NS 32
  • Conductor cross section short circuit testing
    4 mm²
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Test frequency
    f1 = 5 Hz to f2 = 150 Hz
  • Shock duration
    30 ms
  • Static insulating material application in cold
    -60 °C
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Pitch
    9 mm
  • Stripping length
    The stripping length depends on the specification provided by the cable lug manufacturer.
  • AWG max
    10
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 6.0
    27141100
  • ETIM 2.0
    EC000897
  • ETIM 7.0
    EC000897
  • ETIM 6.0
    EC000897
  • UNSPSC 12.01
    39121410
  • Potentials
    1
  • Flammability rating according to UL 94
    V0
  • Nominal voltage UN
    800 V
  • Result of power-frequency withstand voltage test
    Test passed
  • Result of voltage-drop test
    Test passed
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Oscillation, broadband noise test result
    Test passed
  • Acceleration
    5g
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Number of shocks per direction
    3
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Width
    9 mm
  • Height NS 35/15
    54.6 mm
  • Connection in acc. with standard
    CUL
  • AWG min
    26
  • Screw thread
    M4
  • Bolt diameter
    4 mm
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 4.1
    27141100
  • ECLASS 5.1
    27141100
  • ECLASS 9.0
    27141120
  • UNSPSC 6.01
    30211811
  • UNSPSC 13.2
    39121410
  • UNSPSC 20.0
    39121410
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • ECLASS 10.0.1
    27141120
  • ECLASS 11.0
    27141120
  • ETIM 4.0
    EC000897
  • UNSPSC 7.0901
    39121410
  • UNSPSC 11
    39121410
  • UNSPSC 19.0
    39121410
  • ECLASS 5.0
    27141100
  • ECLASS 7.0
    27141120
  • ETIM 3.0
    EC000897
  • UNSPSC 18.0
    39121410
  • UNSPSC 21.0
    39121410

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

3058127 Phoenix Contact

Get a quick Quote!

Request a quote, and we will send you price within minutes.

Stock:

10

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare 3058127 with other products

Nominal cross section

Rated surge voltage

Degree of pollution

Power frequency withstand...

Result of tight fit on su...

Short circuit stability r...

ASD level

Test directions

Relative insulation mater...

Calorimetric heat release...

Fire protection for rail ...

End cover width

Height NS 32

Max. cross section for ca...

Hole diameter, min.

Tightening torque, min

Ambient temperature (actu...

Number of connections

Insulating material group

Nominal current IN

Result of surge voltage t...

Setpoint

Result of thermal test

Test specification, oscil...

Test duration per axis

Temperature index of insu...

Fire protection for rail ...

Length

Connection

Cable lug connection acco...

Min. cross section for ca...

Cable lug width, max.

Tightening torque max

ECLASS 4.0

Color

Overvoltage category

Maximum power dissipation...

Result of the test for me...

Result of temperature-ris...

Short-time current

Test spectrum

Shock test result

Shock form

Specific optical density ...

Fire protection for rail ...

Height NS 35/7,5

Connection method

Number of levels

Insulating material

Maximum load current

Open side panel

Tight fit on carrier

Conductor cross section s...

Proof of thermal characte...

Test frequency

Shock duration

Static insulating materia...

Smoke gas toxicity NFPA 1...

Fire protection for rail ...

Pitch

Stripping length

AWG max

Operating temperature

Permissible humidity (sto...

China RoHS

ECLASS 6.0

ETIM 2.0

ETIM 7.0

ETIM 6.0

UNSPSC 12.01

Potentials

Flammability rating accor...

Nominal voltage UN

Result of power-frequency...

Result of voltage-drop te...

Requirement temperature-r...

Oscillation, broadband no...

Acceleration

Test specification, shock...

Number of shocks per dire...

Surface flammability NFPA...

Width

Height NS 35/15

Connection in acc. with s...

AWG min

Screw thread

Bolt diameter

Ambient temperature (asse...

ECLASS 4.1

ECLASS 5.1

ECLASS 9.0

UNSPSC 6.01

UNSPSC 13.2

UNSPSC 20.0

Ambient temperature (stor...

ECLASS 10.0.1

ECLASS 11.0

ETIM 4.0

UNSPSC 7.0901

UNSPSC 11

UNSPSC 19.0

ECLASS 5.0

ECLASS 7.0

ETIM 3.0

UNSPSC 18.0

UNSPSC 21.0

Back of the hand protecti...

Note

Shock protection test spe...

Note regarding shock prot...

Finger protection

Area of application

REACh SVHC

Selected product

3058127
10 in stock
3058127
Phoenix Contact

Feed-through terminal block with bolt connection method, cross section: 0.1 - 6 mm², AWG: 26 - 10, w...

Nominal cross section4 mm²

Rated surge voltage8 kV

Degree of pollution3

Power frequency withstand voltage setpoint2 kV

Result of tight fit on supportTest passed

Short circuit stability resultTest passed

ASD level1.857 (m/s2)2/Hz

Test directionsX-, Y- and Z-axis (pos. and ...

Relative insulation material temperature index (Elec., UL 746 B)130 °C

Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg

Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3

End cover width2.2 mm

Height NS 3252.1 mm

Max. cross section for cable lug connection2.5 mm²

Hole diameter, min.4.3 mm

Tightening torque, min1.2 Nm

Ambient temperature (actuation)-5 °C ... 70 °C

Number of connections2

Insulating material groupI

Nominal current IN32 A

Result of surge voltage testTest passed

Setpoint1 N

Result of thermal testTest passed

Test specification, oscillation, broadband noiseDIN EN 50155 (VDE 0115-200):...

Test duration per axis5 h

Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C

Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3

Length53.3 mm

Connection1 level

Cable lug connection according to standardDIN 46237:1970-07

Min. cross section for cable lug connection0.5 mm²

Cable lug width, max.8 mm

Tightening torque max1.4 Nm

ECLASS 4.027141100

Colorgray

Overvoltage categoryIII

Maximum power dissipation for nominal condition1.02 W

Result of the test for mechanical stability of terminal points (5 x conductor connection)Test passed

Result of temperature-rise testTest passed

Short-time current0.48 kA

Test spectrumService life test category 1...

Shock test resultTest passed

Shock formHalf-sine

Specific optical density of smoke NFPA 130 (ASTM E 662)passed

Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3

Height NS 35/7,547.1 mm

Connection methodBolt connection

Number of levels1

Insulating materialPA

Maximum load current32 A

Open side panelYes

Tight fit on carrierNS 35/NS 32

Conductor cross section short circuit testing4 mm²

Proof of thermal characteristics (needle flame) effective duration30 s

Test frequencyf1 = 5 Hz to f2 = 150 Hz

Shock duration30 ms

Static insulating material application in cold-60 °C

Smoke gas toxicity NFPA 130 (SMP 800C)passed

Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Pitch9 mm

Stripping lengthThe stripping length depends...

AWG max10

Operating temperature-60 °C ... 105 °C (max. shor...

Permissible humidity (storage/transport)30 % ... 70 %

China RoHSEnvironmentally friendly use...

ECLASS 6.027141100

ETIM 2.0EC000897

ETIM 7.0EC000897

ETIM 6.0EC000897

UNSPSC 12.0139121410

Potentials1

Flammability rating according to UL 94V0

Nominal voltage UN800 V

Result of power-frequency withstand voltage testTest passed

Result of voltage-drop testTest passed

Requirement temperature-rise testIncrease in temperature ≤ 45...

Oscillation, broadband noise test resultTest passed

Acceleration5g

Test specification, shock testDIN EN 50155 (VDE 0115-200):...

Number of shocks per direction3

Surface flammability NFPA 130 (ASTM E 162)passed

Width9 mm

Height NS 35/1554.6 mm

Connection in acc. with standardCUL

AWG min26

Screw threadM4

Bolt diameter4 mm

Ambient temperature (assembly)-5 °C ... 70 °C

ECLASS 4.127141100

ECLASS 5.127141100

ECLASS 9.027141120

UNSPSC 6.0130211811

UNSPSC 13.239121410

UNSPSC 20.039121410

Ambient temperature (storage/transport)-25 °C ... 60 °C (for a shor...

ECLASS 10.0.127141120

ECLASS 11.027141120

ETIM 4.0EC000897

UNSPSC 7.090139121410

UNSPSC 1139121410

UNSPSC 19.039121410

ECLASS 5.027141100

ECLASS 7.027141120

ETIM 3.0EC000897

UNSPSC 18.039121410

UNSPSC 21.039121410

Back of the hand protection-

Note-

Shock protection test specification-

Note regarding shock protection-

Finger protection-

Area of application-

REACh SVHC-

3075870
11 in stock
3075870
Phoenix Contact

Feed-through terminal block with bolt connection method, cross section: 2.5 - 35 mm², AWG: 12 - 2, w...

Nominal cross section35 mm²

Rated surge voltage8 kV

Degree of pollution3

Power frequency withstand voltage setpoint2 kV

Result of tight fit on supportTest passed

Short circuit stability resultTest passed

ASD level1.857 (m/s2)2/Hz

Test directionsX-, Y- and Z-axis (pos. and ...

Relative insulation material temperature index (Elec., UL 746 B)130 °C

Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg

Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3

End cover width2.2 mm

Height NS 3254.8 mm

Max. cross section for cable lug connection6 mm²

Hole diameter, min.6.5 mm

Tightening torque, min3.2 Nm

Ambient temperature (actuation)-5 °C ... 70 °C

Number of connections2

Insulating material groupI

Nominal current IN125 A

Result of surge voltage testTest passed

Setpoint10 N

Result of thermal testTest passed

Test specification, oscillation, broadband noiseDIN EN 50155 (VDE 0115-200):...

Test duration per axis5 h

Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C

Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3

Length80.8 mm

Connection1 level

Cable lug connection according to standardDIN 46237:1970-07

Min. cross section for cable lug connection2.5 mm²

Cable lug width, max.11 mm

Tightening torque max3.7 Nm

ECLASS 4.027141100

Colorgray

Overvoltage categoryIII

Maximum power dissipation for nominal condition4.06 W

Result of the test for mechanical stability of terminal points (5 x conductor connection)Test passed

Result of temperature-rise testTest passed

Short-time current4.2 kA

Test spectrumService life test category 1...

Shock test resultTest passed

Shock formHalf-sine

Specific optical density of smoke NFPA 130 (ASTM E 662)passed

Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3

Height NS 35/7,549.8 mm

Connection methodBolt connection

Number of levels1

Insulating materialPA

Maximum load current125 A (with 35 mm² conductor...

Open side panelNo

Tight fit on carrierNS 35/NS 32

Conductor cross section short circuit testing35 mm²

Proof of thermal characteristics (needle flame) effective duration30 s

Test frequencyf1 = 5 Hz to f2 = 150 Hz

Shock duration30 ms

Static insulating material application in cold-60 °C

Smoke gas toxicity NFPA 130 (SMP 800C)passed

Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Pitch17 mm

Stripping lengthThe stripping length depends...

AWG max10

Operating temperature-60 °C ... 105 °C (max. shor...

Permissible humidity (storage/transport)30 % ... 70 %

China RoHSEnvironmentally friendly use...

ECLASS 6.027141100

ETIM 2.0-

ETIM 7.0EC000897

ETIM 6.0EC000897

UNSPSC 12.0139121410

Potentials1

Flammability rating according to UL 94V0

Nominal voltage UN800 V

Result of power-frequency withstand voltage testTest passed

Result of voltage-drop testTest passed

Requirement temperature-rise testIncrease in temperature ≤ 45...

Oscillation, broadband noise test resultTest passed

Acceleration5g

Test specification, shock testDIN EN 50155 (VDE 0115-200):...

Number of shocks per direction3

Surface flammability NFPA 130 (ASTM E 162)passed

Width17 mm

Height NS 35/1557.3 mm

Connection in acc. with standardCUL

AWG min14

Screw threadM6

Bolt diameter6 mm

Ambient temperature (assembly)-5 °C ... 70 °C

ECLASS 4.127141100

ECLASS 5.127141100

ECLASS 9.027141120

UNSPSC 6.0130211811

UNSPSC 13.239121410

UNSPSC 20.039121410

Ambient temperature (storage/transport)-25 °C ... 60 °C (for a shor...

ECLASS 10.0.127141120

ECLASS 11.027141120

ETIM 4.0EC000897

UNSPSC 7.090139121410

UNSPSC 1139121410

UNSPSC 19.039121410

ECLASS 5.027141100

ECLASS 7.027141120

ETIM 3.0EC000897

UNSPSC 18.039121410

UNSPSC 21.039121410

Back of the hand protection-

Note-

Shock protection test specification-

Note regarding shock protection-

Finger protection-

Area of application-

REACh SVHC-

3049013
19 in stock
3049013
Phoenix Contact

Bolt connection terminal block, Note: the BE-RT... path extension is to be used for non-insulated ca...

Nominal cross section2.5 mm²

Rated surge voltage8 kV

Degree of pollution3

Power frequency withstand voltage setpoint2.2 kV

Result of tight fit on supportTest passed

Short circuit stability resultTest passed

ASD level1.857 (m/s2)2/Hz

Test directionsX-, Y- and Z-axis (pos. and ...

Relative insulation material temperature index (Elec., UL 746 B)130 °C

Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg

Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3

End cover width2.2 mm

Height NS 32-

Max. cross section for cable lug connection2.5 mm²

Hole diameter, min.3.2 mm

Tightening torque, min0.6 Nm

Ambient temperature (actuation)-5 °C ... 70 °C

Number of connections2

Insulating material groupI

Nominal current IN24 A

Result of surge voltage testTest passed

Setpoint1 N

Result of thermal testTest passed

Test specification, oscillation, broadband noiseDIN EN 50155 (VDE 0115-200):...

Test duration per axis5 h

Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C

Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3

Length66 mm

Connection1 level

Cable lug connection according to standardDIN 46237:1970-07

Min. cross section for cable lug connection1 mm²

Cable lug width, max.6 mm

Tightening torque max0.8 Nm

ECLASS 4.027141100

Colorgray

Overvoltage categoryIII

Maximum power dissipation for nominal condition0.77 W

Result of the test for mechanical stability of terminal points (5 x conductor connection)Test passed

Result of temperature-rise testTest passed

Short-time current0.3 kA

Test spectrumService life test category 1...

Shock test resultTest passed

Shock formHalf-sine

Specific optical density of smoke NFPA 130 (ASTM E 662)passed

Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3

Height NS 35/7,551 mm

Connection methodBolt connection

Number of levels1

Insulating materialPA

Maximum load current24 A (with a 2.5 mm² conduct...

Open side panelYes

Tight fit on carrierNS 35

Conductor cross section short circuit testing2.5 mm²

Proof of thermal characteristics (needle flame) effective duration30 s

Test frequencyf1 = 5 Hz to f2 = 150 Hz

Shock duration30 ms

Static insulating material application in cold-60 °C

Smoke gas toxicity NFPA 130 (SMP 800C)passed

Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Pitch-

Stripping lengthThe stripping length depends...

AWG max14

Operating temperature-60 °C ... 105 °C (max. shor...

Permissible humidity (storage/transport)30 % ... 70 %

China RoHSEnvironmentally friendly use...

ECLASS 6.027141100

ETIM 2.0EC000897

ETIM 7.0EC000897

ETIM 6.0EC000897

UNSPSC 12.0139121410

Potentials1

Flammability rating according to UL 94V0

Nominal voltage UN1000 V (Rated voltage for op...

Result of power-frequency withstand voltage testTest passed

Result of voltage-drop testTest passed

Requirement temperature-rise testIncrease in temperature ≤ 45...

Oscillation, broadband noise test resultTest passed

Acceleration5g

Test specification, shock testDIN EN 50155 (VDE 0115-200):...

Number of shocks per direction3

Surface flammability NFPA 130 (ASTM E 162)passed

Width12.3 mm

Height NS 35/1558.5 mm

Connection in acc. with standardCUL

AWG min18

Screw threadM3

Bolt diameter3 mm

Ambient temperature (assembly)-5 °C ... 70 °C

ECLASS 4.127141100

ECLASS 5.127141100

ECLASS 9.027141120

UNSPSC 6.0130211811

UNSPSC 13.239121410

UNSPSC 20.039121410

Ambient temperature (storage/transport)-25 °C ... 60 °C (for a shor...

ECLASS 10.0.127141120

ECLASS 11.027141120

ETIM 4.0EC000897

UNSPSC 7.090139121410

UNSPSC 1139121410

UNSPSC 19.039121410

ECLASS 5.027141100

ECLASS 7.027141120

ETIM 3.0EC000897

UNSPSC 18.039121410

UNSPSC 21.039121410

Back of the hand protectionguaranteed

NoteNote: the BE-RT... path exte...

Shock protection test specificationDIN EN 50274 (VDE 0660-514):...

Note regarding shock protectionElectric shock protection on...

Finger protectionguaranteed

Area of applicationRailway industry

REACh SVHCLead 7439-92-1

About the manufacturer

Phoenix Contact

Powermatic Associates is an authorized Phoenix Contact distributor, proudly offering a wide array of innovative industrial solutions that cater to modern technological demands. Phoenix Contact is a global leader renowned for its high-quality products in the fields of electrical engineering and automation technology. Their extensive catalog encompasses everything from connection technology, interface systems, and surge protection to automation software and control technology, making them a versatile choice for various industrial applications. At Powermatic Associates, we deliver Phoenix Contact’s pioneering connectivity and power management solutions, which include terminal blocks, connectors, relays, and PLCs. These components are essential for creating efficient and reliable electrical connections in diverse environments, ensuring seamless system integration. The company's comprehensive range of Industrial Internet of Things (IIoT) solutions facilitates intelligent networking, enabling customers to optimize their automation processes with cutting-edge technology. Phoenix Contact's emphasis on sustainability and innovation reflects in their energy management systems and renewable energy solutions. By incorporating these into your operations, you not only enhance efficiency but also contribute to sustainable practices, aligning with modern environmental standards. Powermatic Associates recognizes the significance of such advancements and partners with Phoenix Contact to provide expert engineering support and tailored solutions, helping you implement smart technologies that drive productivity and minimize costs. With a focus on safety and reliability, Phoenix Contact offers advanced surge protection devices and signal conditioners that safeguard your equipment against voltage spikes and ensure data integrity. In collaboration with Powermatic Associates, customers gain access to robust technical support and consultation, ensuring that every project benefits from personalized guidance and quick resolution of technical challenges. Our partnership extends the reach of Phoenix Contact’s globally recognized industrial automation products, including Human Machine Interfaces (HMIs) and Ethernet switches, empowering businesses with enhanced operational control and communication capabilities. Customers can trust Powermatic Associates to deliver prompt shipping and thorough assistance, ensuring that Phoenix Contact’s top-tier products are seamlessly integrated into their workflows for optimal performance.

Recently viewed products

Relevant products

FAQ

10 in stock

Feed-through terminal block with bolt connection method, cross section: 0.1 - 6 mm², AWG: 26 - 10, width 9 mm, color: gray

Similar products from: Terminal Blocks

What can I help you find today?

Recommended parts