Product description
Feed-through terminal block with bolt connection method, cross section: 0.1 - 6 mm², AWG: 26 - 10, width 9 mm, color: gray
Product Details
- Nominal cross section 4 mm²
- Rated surge voltage 8 kV
- Degree of pollution 3
- Power frequency withstand voltage setpoint 2 kV
- Result of tight fit on support Test passed
- Short circuit stability result Test passed
- ASD level 1.857 (m/s2)2/Hz
- Test directions X-, Y- and Z-axis (pos. and neg.)
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- End cover width 2.2 mm
- Height NS 32 52.1 mm
- Max. cross section for cable lug connection 2.5 mm²
- Hole diameter, min. 4.3 mm
- Tightening torque, min 1.2 Nm
- Ambient temperature (actuation) -5 °C ... 70 °C
- Number of connections 2
- Insulating material group I
- Nominal current IN 32 A
- Result of surge voltage test Test passed
- Setpoint 1 N
- Result of thermal test Test passed
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2008-03
- Test duration per axis 5 h
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Length 53.3 mm
- Connection 1 level
- Cable lug connection according to standard DIN 46237:1970-07
- Min. cross section for cable lug connection 0.5 mm²
- Cable lug width, max. 8 mm
- Tightening torque max 1.4 Nm
- ECLASS 4.0 27141100
- Color gray
- Overvoltage category III
- Maximum power dissipation for nominal condition 1.02 W
- Result of the test for mechanical stability of terminal points (5 x conductor connection) Test passed
- Result of temperature-rise test Test passed
- Short-time current 0.48 kA
- Test spectrum Service life test category 1, class B, body mounted
- Shock test result Test passed
- Shock form Half-sine
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Height NS 35/7,5 47.1 mm
- Connection method Bolt connection
- Number of levels 1
- Insulating material PA
- Maximum load current 32 A
- Open side panel Yes
- Tight fit on carrier NS 35/NS 32
- Conductor cross section short circuit testing 4 mm²
- Proof of thermal characteristics (needle flame) effective duration 30 s
- Test frequency f1 = 5 Hz to f2 = 150 Hz
- Shock duration 30 ms
- Static insulating material application in cold -60 °C
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Pitch 9 mm
- Stripping length The stripping length depends on the specification provided by the cable lug manufacturer.
- AWG max 10
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- Permissible humidity (storage/transport) 30 % ... 70 %
- China RoHS Environmentally friendly use period: unlimited = EFUP-e
- ECLASS 6.0 27141100
- ETIM 2.0 EC000897
- ETIM 7.0 EC000897
- ETIM 6.0 EC000897
- UNSPSC 12.01 39121410
- Potentials 1
- Flammability rating according to UL 94 V0
- Nominal voltage UN 800 V
- Result of power-frequency withstand voltage test Test passed
- Result of voltage-drop test Test passed
- Requirement temperature-rise test Increase in temperature ≤ 45 K
- Oscillation, broadband noise test result Test passed
- Acceleration 5g
- Test specification, shock test DIN EN 50155 (VDE 0115-200):2008-03
- Number of shocks per direction 3
- Surface flammability NFPA 130 (ASTM E 162) passed
- Width 9 mm
- Height NS 35/15 54.6 mm
- Connection in acc. with standard CUL
- AWG min 26
- Screw thread M4
- Bolt diameter 4 mm
- Ambient temperature (assembly) -5 °C ... 70 °C
- ECLASS 4.1 27141100
- ECLASS 5.1 27141100
- ECLASS 9.0 27141120
- UNSPSC 6.01 30211811
- UNSPSC 13.2 39121410
- UNSPSC 20.0 39121410
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- ECLASS 10.0.1 27141120
- ECLASS 11.0 27141120
- ETIM 4.0 EC000897
- UNSPSC 7.0901 39121410
- UNSPSC 11 39121410
- UNSPSC 19.0 39121410
- ECLASS 5.0 27141100
- ECLASS 7.0 27141120
- ETIM 3.0 EC000897
- UNSPSC 18.0 39121410
- UNSPSC 21.0 39121410
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
3058127 Phoenix Contact
Get a quick Quote!
Request a quote, and we will send you price within minutes.
Stock:
Select Qty:
Average response time: 11 minutes
Worldwide Shipping and Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare 3058127 with other products
Nominal cross section
Rated surge voltage
Degree of pollution
Power frequency withstand...
Result of tight fit on su...
Short circuit stability r...
ASD level
Test directions
Relative insulation mater...
Calorimetric heat release...
Fire protection for rail ...
End cover width
Height NS 32
Max. cross section for ca...
Hole diameter, min.
Tightening torque, min
Ambient temperature (actu...
Number of connections
Insulating material group
Nominal current IN
Result of surge voltage t...
Setpoint
Result of thermal test
Test specification, oscil...
Test duration per axis
Temperature index of insu...
Fire protection for rail ...
Length
Connection
Cable lug connection acco...
Min. cross section for ca...
Cable lug width, max.
Tightening torque max
ECLASS 4.0
Color
Overvoltage category
Maximum power dissipation...
Result of the test for me...
Result of temperature-ris...
Short-time current
Test spectrum
Shock test result
Shock form
Specific optical density ...
Fire protection for rail ...
Height NS 35/7,5
Connection method
Number of levels
Insulating material
Maximum load current
Open side panel
Tight fit on carrier
Conductor cross section s...
Proof of thermal characte...
Test frequency
Shock duration
Static insulating materia...
Smoke gas toxicity NFPA 1...
Fire protection for rail ...
Pitch
Stripping length
AWG max
Operating temperature
Permissible humidity (sto...
China RoHS
ECLASS 6.0
ETIM 2.0
ETIM 7.0
ETIM 6.0
UNSPSC 12.01
Potentials
Flammability rating accor...
Nominal voltage UN
Result of power-frequency...
Result of voltage-drop te...
Requirement temperature-r...
Oscillation, broadband no...
Acceleration
Test specification, shock...
Number of shocks per dire...
Surface flammability NFPA...
Width
Height NS 35/15
Connection in acc. with s...
AWG min
Screw thread
Bolt diameter
Ambient temperature (asse...
ECLASS 4.1
ECLASS 5.1
ECLASS 9.0
UNSPSC 6.01
UNSPSC 13.2
UNSPSC 20.0
Ambient temperature (stor...
ECLASS 10.0.1
ECLASS 11.0
ETIM 4.0
UNSPSC 7.0901
UNSPSC 11
UNSPSC 19.0
ECLASS 5.0
ECLASS 7.0
ETIM 3.0
UNSPSC 18.0
UNSPSC 21.0
Back of the hand protecti...
Note
Shock protection test spe...
Note regarding shock prot...
Finger protection
Area of application
REACh SVHC
Selected product

3058127
Phoenix Contact
Feed-through terminal block with bolt connection method, cross section: 0.1 - 6 mm², AWG: 26 - 10, w...
Nominal cross section4 mm²
Rated surge voltage8 kV
Degree of pollution3
Power frequency withstand voltage setpoint2 kV
Result of tight fit on supportTest passed
Short circuit stability resultTest passed
ASD level1.857 (m/s2)2/Hz
Test directionsX-, Y- and Z-axis (pos. and ...
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
End cover width2.2 mm
Height NS 3252.1 mm
Max. cross section for cable lug connection2.5 mm²
Hole diameter, min.4.3 mm
Tightening torque, min1.2 Nm
Ambient temperature (actuation)-5 °C ... 70 °C
Number of connections2
Insulating material groupI
Nominal current IN32 A
Result of surge voltage testTest passed
Setpoint1 N
Result of thermal testTest passed
Test specification, oscillation, broadband noiseDIN EN 50155 (VDE 0115-200):...
Test duration per axis5 h
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Length53.3 mm
Connection1 level
Cable lug connection according to standardDIN 46237:1970-07
Min. cross section for cable lug connection0.5 mm²
Cable lug width, max.8 mm
Tightening torque max1.4 Nm
ECLASS 4.027141100
Colorgray
Overvoltage categoryIII
Maximum power dissipation for nominal condition1.02 W
Result of the test for mechanical stability of terminal points (5 x conductor connection)Test passed
Result of temperature-rise testTest passed
Short-time current0.48 kA
Test spectrumService life test category 1...
Shock test resultTest passed
Shock formHalf-sine
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Height NS 35/7,547.1 mm
Connection methodBolt connection
Number of levels1
Insulating materialPA
Maximum load current32 A
Open side panelYes
Tight fit on carrierNS 35/NS 32
Conductor cross section short circuit testing4 mm²
Proof of thermal characteristics (needle flame) effective duration30 s
Test frequencyf1 = 5 Hz to f2 = 150 Hz
Shock duration30 ms
Static insulating material application in cold-60 °C
Smoke gas toxicity NFPA 130 (SMP 800C)passed
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3
Pitch9 mm
Stripping lengthThe stripping length depends...
AWG max10
Operating temperature-60 °C ... 105 °C (max. shor...
Permissible humidity (storage/transport)30 % ... 70 %
China RoHSEnvironmentally friendly use...
ECLASS 6.027141100
ETIM 2.0EC000897
ETIM 7.0EC000897
ETIM 6.0EC000897
UNSPSC 12.0139121410
Potentials1
Flammability rating according to UL 94V0
Nominal voltage UN800 V
Result of power-frequency withstand voltage testTest passed
Result of voltage-drop testTest passed
Requirement temperature-rise testIncrease in temperature ≤ 45...
Oscillation, broadband noise test resultTest passed
Acceleration5g
Test specification, shock testDIN EN 50155 (VDE 0115-200):...
Number of shocks per direction3
Surface flammability NFPA 130 (ASTM E 162)passed
Width9 mm
Height NS 35/1554.6 mm
Connection in acc. with standardCUL
AWG min26
Screw threadM4
Bolt diameter4 mm
Ambient temperature (assembly)-5 °C ... 70 °C
ECLASS 4.127141100
ECLASS 5.127141100
ECLASS 9.027141120
UNSPSC 6.0130211811
UNSPSC 13.239121410
UNSPSC 20.039121410
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a shor...
ECLASS 10.0.127141120
ECLASS 11.027141120
ETIM 4.0EC000897
UNSPSC 7.090139121410
UNSPSC 1139121410
UNSPSC 19.039121410
ECLASS 5.027141100
ECLASS 7.027141120
ETIM 3.0EC000897
UNSPSC 18.039121410
UNSPSC 21.039121410
Back of the hand protection-
Note-
Shock protection test specification-
Note regarding shock protection-
Finger protection-
Area of application-
REACh SVHC-
About the manufacturer

Powermatic Associates is an authorized Phoenix Contact distributor, proudly offering a wide array of innovative industrial solutions that cater to modern technological demands. Phoenix Contact is a global leader renowned for its high-quality products in the fields of electrical engineering and automation technology. Their extensive catalog encompasses everything from connection technology, interface systems, and surge protection to automation software and control technology, making them a versatile choice for various industrial applications. At Powermatic Associates, we deliver Phoenix Contact’s pioneering connectivity and power management solutions, which include terminal blocks, connectors, relays, and PLCs. These components are essential for creating efficient and reliable electrical connections in diverse environments, ensuring seamless system integration. The company's comprehensive range of Industrial Internet of Things (IIoT) solutions facilitates intelligent networking, enabling customers to optimize their automation processes with cutting-edge technology. Phoenix Contact's emphasis on sustainability and innovation reflects in their energy management systems and renewable energy solutions. By incorporating these into your operations, you not only enhance efficiency but also contribute to sustainable practices, aligning with modern environmental standards. Powermatic Associates recognizes the significance of such advancements and partners with Phoenix Contact to provide expert engineering support and tailored solutions, helping you implement smart technologies that drive productivity and minimize costs. With a focus on safety and reliability, Phoenix Contact offers advanced surge protection devices and signal conditioners that safeguard your equipment against voltage spikes and ensure data integrity. In collaboration with Powermatic Associates, customers gain access to robust technical support and consultation, ensuring that every project benefits from personalized guidance and quick resolution of technical challenges. Our partnership extends the reach of Phoenix Contact’s globally recognized industrial automation products, including Human Machine Interfaces (HMIs) and Ethernet switches, empowering businesses with enhanced operational control and communication capabilities. Customers can trust Powermatic Associates to deliver prompt shipping and thorough assistance, ensuring that Phoenix Contact’s top-tier products are seamlessly integrated into their workflows for optimal performance.
Recently viewed products
Relevant products
FAQ
10 in stock
Feed-through terminal block with bolt connection method, cross section: 0.1 - 6 mm², AWG: 26 - 10, width 9 mm, color: gray
Similar products from: Terminal Blocks
What can I help you find today?