electrical interface CPX-CP-4-FB Connection of all CP modules to the CPX valve terminal is made possible with the CPX CP interface. Corrosion resistance classification CRC: 2 - Moderate corrosion stress, Product weight: 139 g
Quick Quote
analogue input module CPX-E-4AI-U-I Dimensions W x L x H: 18,9 mm x 76,6 mm x 124,3 mm, Grid dimension: 18,9 mm, No. of inputs: 4, Diagnostics via LED: (* Error per channel, * Error per module), Diagnostics via bus: (* Wire break, * Short circuit/overload
Quick Quote
input module CPX-L-16DE-16-KL-3POL Dimensions W x L x H: (* (including interlinking block), * 50 mm x 107 mm x 41 mm), No. of inputs: 16, Diagnosis: Short circuit/overload per channel, Parameters configuring: (* Input debounce time, * Signal extension tim
Quick Quote
digital input module CPX-AP-I-8DI-M8-3P Dimensions W x L x H: 30 mm x 170 mm x 35 mm, No. of inputs: 8, Diagnostics via LED: (* Diagnostics per module, * Status per channel), Diagnostics per internal communication: (* Short circuit/overload in sensor supp
Quick Quote
BL20 base module, Tension spring connection, , Passive connection components for sensors and actuators, Quick replacement of electronics in wired state, Mechanical coding prevents plugging of wrong electronic module, Protection class IP20, Tension spring connection, Block design
Quick Quote
Compact multiprotocol I/O module for Ethernet, 16 Universal Digital Channels, Configurable as PNP Inputs or 2 A Outputs, , PROFINET device, EtherNet/IP device or Modbus TCP slave, Integrated Ethernet switch, Supports 10 Mbps/100 Mbps, 2 × M12, 4-pin, D-coded, Ethernet fieldbus connection, PROFINET S2 system redundancy, Glass fiber reinforced housing, Shock and vibration tested, Fully potted module electronics, Protection classes IP65, IP67, IP69K, M12, 5-pin, L-coded male connector for power sup
Quick Quote
Block Module for EtherNet/IP and CIP Safety, Safe Digital Inputs and Outputs, , Ethernet/IP, Integrated Ethernet switch, 10 Mbps/100 Mbps supported, 2 × M12, 4-pin, D-coded, Ethernet fieldbus connection, Glass fiber reinforced housing, Shock and vibration tested, Fully potted module electronics, Protection classes IP65, IP67, IP69K, 7/8, 5-pin connectors for power supply, ATEX Zone 2/22, Four secure digital SIL3 inputs, Four secure configurable digital SIL3 inputs or outputs, "
Quick Quote
I/O Hub for connection of digital signals to IO-Link Master, 8 Digital Inputs, 8 M8 Ports, , Glass fiber reinforced housing, Shock and vibration tested, Fully potted module electronics, Protection classes IP65, IP67, IP69K
Quick Quote
BL compact™ fieldbus station for DeviceNet™, 2 Analog Outputs for Current, On-machine Compact fieldbus I/O block, DeviceNet™ slave, 125 / 250 / 500 kbps, Two 5-pole M12 connectors for fieldbus connection, 2 rotary switches for node address, IP67, IP69K, M12 I/O connectors, LEDs indicating status and diagnostics, Electronics galvanically separated from the field level via optocouplers, 2 analog current outputs, 0/4…20 mA
Quick Quote
Compact Multiprotocol I/O Module for Ethernet, 8 Digital PNP Inputs, , PROFINET device, EtherNet/IP device or Modbus TCP slave, Integrated Ethernet switch, Supports 10 Mbps / 100 Mbps, 2x M8, 4-pin, Ethernet fieldbus connection, Glass fiber reinforced housing, Shock and vibration tested, Fully potted module electronics, Protection classes IP65, IP67, IP69K, Pin1 switchable per I/O port, ATEX Zone 2/22, Diagnostics of the supply per I/O port, Programmable ARGEE
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
526705 electrical interface CPX-CP-4-FB Connection of all CP modules to the CPX valve terminal is made possible with the CPX CP interface. Corrosion resistance classification CRC: 2 - Moderate corrosion stress, Product weight: 139 g | Festo | Quick Quote | |||
4080493 analogue input module CPX-E-4AI-U-I Dimensions W x L x H: 18,9 mm x 76,6 mm x 124,3 mm, Grid dimension: 18,9 mm, No. of inputs: 4, Diagnostics via LED: (* Error per channel, * Error per module), Diagnostics via bus: (* Wire break, * Short circuit/overload | Festo | Quick Quote | |||
572606 input module CPX-L-16DE-16-KL-3POL Dimensions W x L x H: (* (including interlinking block), * 50 mm x 107 mm x 41 mm), No. of inputs: 16, Diagnosis: Short circuit/overload per channel, Parameters configuring: (* Input debounce time, * Signal extension tim | Festo | Quick Quote | |||
8086600 digital input module CPX-AP-I-8DI-M8-3P Dimensions W x L x H: 30 mm x 170 mm x 35 mm, No. of inputs: 8, Diagnostics via LED: (* Diagnostics per module, * Status per channel), Diagnostics per internal communication: (* Short circuit/overload in sensor supp | Festo | Quick Quote | |||
BL20-B3T-SBB BL20 base module, Tension spring connection, , Passive connection components for sensors and actuators, Quick replacement of electronics in wired state, Mechanical coding prevents plugging of wrong electronic module, Protection class IP20, Tension spring connection, Block design | Turck | Quick Quote | |||
TBEN-LL-16DXP Compact multiprotocol I/O module for Ethernet, 16 Universal Digital Channels, Configurable as PNP Inputs or 2 A Outputs, , PROFINET device, EtherNet/IP device or Modbus TCP slave, Integrated Ethernet switch, Supports 10 Mbps/100 Mbps, 2 × M12, 4-pin, D-coded, Ethernet fieldbus connection, PROFINET S2 system redundancy, Glass fiber reinforced housing, Shock and vibration tested, Fully potted module electronics, Protection classes IP65, IP67, IP69K, M12, 5-pin, L-coded male connector for power sup | Turck | Quick Quote | |||
TBIP-L5-4FDI-4FDX Block Module for EtherNet/IP and CIP Safety, Safe Digital Inputs and Outputs, , Ethernet/IP, Integrated Ethernet switch, 10 Mbps/100 Mbps supported, 2 × M12, 4-pin, D-coded, Ethernet fieldbus connection, Glass fiber reinforced housing, Shock and vibration tested, Fully potted module electronics, Protection classes IP65, IP67, IP69K, 7/8, 5-pin connectors for power supply, ATEX Zone 2/22, Four secure digital SIL3 inputs, Four secure configurable digital SIL3 inputs or outputs, " | Turck | Quick Quote | |||
TBIL-S3-8DIP I/O Hub for connection of digital signals to IO-Link Master, 8 Digital Inputs, 8 M8 Ports, , Glass fiber reinforced housing, Shock and vibration tested, Fully potted module electronics, Protection classes IP65, IP67, IP69K | Turck | Quick Quote | |||
BLCDN-2M12S-2AO-I BL compact™ fieldbus station for DeviceNet™, 2 Analog Outputs for Current, On-machine Compact fieldbus I/O block, DeviceNet™ slave, 125 / 250 / 500 kbps, Two 5-pole M12 connectors for fieldbus connection, 2 rotary switches for node address, IP67, IP69K, M12 I/O connectors, LEDs indicating status and diagnostics, Electronics galvanically separated from the field level via optocouplers, 2 analog current outputs, 0/4…20 mA | Turck | Quick Quote | |||
TBEN-S2-8DIP Compact Multiprotocol I/O Module for Ethernet, 8 Digital PNP Inputs, , PROFINET device, EtherNet/IP device or Modbus TCP slave, Integrated Ethernet switch, Supports 10 Mbps / 100 Mbps, 2x M8, 4-pin, Ethernet fieldbus connection, Glass fiber reinforced housing, Shock and vibration tested, Fully potted module electronics, Protection classes IP65, IP67, IP69K, Pin1 switchable per I/O port, ATEX Zone 2/22, Diagnostics of the supply per I/O port, Programmable ARGEE | Turck | Quick Quote |