Pilz PILZ-827260 is a protection unit designed as a single-phase voltage monitoring relay suitable for DIN rail mounting. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. The design ensures that measuring inputs are not polarity-sensitive. It features safety output contacts ratings of 0.1A-5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15), with fixed screw terminal connections. The supply voltage requirement is 195.5-264Vac (230Vac / 240Vac nom.) under the sub-range name S1UM. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. The frequency measuring range is 0.4-400Hz, housed in a PPO material. It is designed for a single-phase (1AC) input network, with a rated voltage (AC) for measuring voltage adjustable between 0.1-500Vac/dc. The net width is 22.5 mm, and it consumes 2 VA of power with a net depth of 121 mm. Operating modes include fault latching or fault non-latching, and normally energized mode or normally de-energized mode. It can be stored in temperatures ranging from -40 to +85°C. The unit has 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load) for digital outputs, and protection functions against overvoltage with a response time of 0.1-10 s. Digital inputs consist of 1 x de-energized mode input (Y1-Y2) and 1 x latching input (Y3).
Quick Quote
Pilz PILZ-827240 is a protection unit designed for single-phase voltage monitoring with DIN rail mounting. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. The design ensures that measuring inputs are not polarity-sensitive. It features safety output contacts ratings of 0.1A-5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15), with fixed screw terminal connections. The supply voltage is between 35.7-52.8Vac (42Vac / 48Vac nominal) under the sub-range name S1UM. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. The frequency measuring range is 0.4-400Hz, housed in a PPO material. It is suitable for single-phase (1AC) input networks with a rated voltage for measuring between 0.1-500Vac/dc, adjustable. The net width is 22.5 mm, and it consumes 2 VA of power with a net depth of 121 mm. Operating modes include fault latching or non-latching, normally energized mode, or normally de-energized mode. It can be stored in temperatures ranging from -40 to +85°C. The unit has 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load) and digital inputs for de-energized mode (Y1-Y2) and latching (Y3). Protection functions cover overvoltage, with a response time of 0.1-10 s.
Quick Quote
Pilz PILZ-890170 is a protection unit designed for DIN rail mounting, featuring a phase sequence monitoring relay. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. The unit offers fixed screw terminal connections and requires a supply voltage of 200Vac-240Vac (220Vac / 230Vac nominal) within the S1PN sub-range. With dimensions of W22.5mm x D121mm and a net width of 22.5 mm, it is encased in a PPO housing that provides an IP40 degree of protection. Designed for a 3-phase (3AC) input network with a rated voltage of 200-240Vac, it consumes 8 VA of power. The operating mode is normally energized, and it includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) for digital outputs and 1 x analog input for L1-L3 voltage measurement. Its protection functions include phase sequence and phase failure.
Quick Quote
Pilz PILZ-760100 is a protection unit designed for true power monitoring and measurement, with limit values that can be adjusted via a display and stored on a chip card. It supports DIN rail mounting and operates within an ambient air temperature range of -10 to +55°C. The unit has a net height of 100 mm and accommodates a rated current of 1A-12A for measuring, with safety output contacts ratings of 0.1A-5A at 24Vdc (DC-1; 120W), 0.1A-5A at 240Vac (AC-1; 1200VA), 2A at 24Vdc (DC-13), and 5A at 230Vac (AC-15). Connection is facilitated through plug-in/detachable spring terminal connections. The supply voltage ranges from 19.2-264Vac, covering 24Vac, 110Vac, 120Vac, 220Vac, and 240Vac nominal values, and from 19.2-264Vdc, covering 24Vdc, 110Vdc, 120Vdc, 220Vdc, and 250Vdc nominal values. It falls under the PMD s10 sub-range, with dimensions of W45mm x D120mm, and offers an IP40 degree of protection. The housing is made of PC material, and it is suitable for both single-phase (1AC) and 3-phase (3AC) input networks, with a rated voltage of 100-550Vac/dc for measuring voltage. The net width is 45 mm, and it consumes 3 W of power. Operating modes include fault latching/non-latching, automatic/manual reset, and normally energized/de-energized modes. It can be stored in temperatures ranging from -25 to +85°C. The unit features 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts; 0.1-5A 24Vdc 120W DC-1 or 240Vac 1200VA AC-1 resistive load), 1 x analog input for single-phase or 3-phase voltage measurement, and protection functions against overpower, overcurrent, and undercurrent. It also includes a link terminal and a measuring circuit for digital inputs, and 1 x analog output for voltage and current measurement.
Quick Quote
Pilz PILZ-838000 is a protection unit designed for thermistor monitoring relay applications, featuring DIN rail mounting for easy installation. It operates within an ambient air temperature range of -10 to +55°C and has a net height of 87 mm. The unit is equipped with fixed screw terminal connections and requires a supply voltage of 340-440Vac, with 400Vac nominal. Part of the S1MN sub-range, it measures 22.5mm in width, has a degree of protection of IP40, and is housed in PPO material. The power consumption is rated at 3.5 VA, and the net depth is 121 mm. This protection unit offers both automatic and manual reset operating modes in a normally energized configuration. It can withstand ambient air temperatures for storage between -40 and +85°C. The unit includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) for digital outputs, 2 x analog inputs (T1-T2 measuring circuits), and features overheating protection. Additionally, it has 2 x reset circuit inputs for digital inputs and boasts a mechanical durability of 10 million operations at no load.
Quick Quote
Pilz PILZ-837305 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15), with fixed screw terminal connections. The supply voltage requirement is 195.5-253Vac (230Vac nominal) under the S3UM sub-range, with dimensions of W22.5mm and a degree of protection rated at IP40. It operates across a frequency range of 40-400Hz, encased in a PPO housing, and is designed for a 3-phase (3AC) input network with a 230Vac rated measuring voltage. The net width and depth are 22.5 mm and 122 mm, respectively, with a power consumption of 1.5 W. Operating modes include fault latching/non-latching and normally energized/de-energized modes, with an ambient air temperature range for storage between -40 and +85°C. It features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load; 0.5-10s time-delay selectable) for digital outputs, 1 x analog input for L1-L3 voltage measurement, and protection functions against undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. Digital inputs include 1 x automatic reset and 1 x switching commutation.
Quick Quote
Pilz PILZ-840775 is a protection unit designed for fault voltage monitoring relay applications. It features DIN rail mounting and operates within an ambient air temperature range of -10 to +55 °C. This unit offers fixed screw terminal connections and supports a wide supply voltage range of 19.2-264Vac, including nominal voltages of 24Vac, 110Vac, 120Vac, 220Vac, and 240Vac, as well as a DC supply voltage range of 19.2-264Vdc, with nominal voltages of 24Vdc, 110Vdc, 120Vdc, 220Vdc, and 250Vdc. The PFU6 sub-range model comes with an IP40 degree of protection and is capable of handling frequencies from 50 to 1000Hz. It has a rated voltage for AC and DC measuring voltage up to 690Vac/dc and consumes 2W of power. For storage, it can withstand ambient air temperatures from -40 to +85 °C. The unit includes 1 auxiliary output with SPDT-NO/NC contacts and 6 analog inputs for various measuring circuits. It also features overvoltage protection functions, along with 1 reset input and 1 test input for digital interfacing.
Quick Quote
Pilz PILZ-828030 is a protection unit designed for current monitoring relay applications, featuring DIN rail mounting for easy installation. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. This unit supports a rated current from 0.01 to 15A for measuring current and utilizes fixed screw terminal connections. It is supplied with a voltage range of 110Vac to 127Vac (120Vac nominal) under the sub-range name S1IM. The dimensions include a width of 22.5mm and a degree of protection rated at IP40, with a frequency measuring range of 40-400Hz. Constructed with a PPO housing, it is designed for single-phase (1AC) input networks and has a net width of 22.5 mm. The power consumption is minimal at 2 VA, and the net depth is 121 mm. It offers versatile operating modes including fault latching/non-latching and normally energized/de-energized modes. The ambient air temperature for storage extends from -40 to +85°C. It features 1 x auxiliary output (SPDT-NO/NC contacts) for digital outputs, and protection functions against overcurrent. Digital inputs include 1 x latching/non-latching input, 1 x energized/de-energized mode input, and 1 x measuring range input for enhanced flexibility in application.
Quick Quote
Pilz PILZ-890071 is a protection unit designed for true power monitoring with a relay function. It features nine different measuring ranges, allowing for adjustable switching underload and overload thresholds. The unit also offers adjustable monitoring reaction time and start-up suppression time for tailored operation. Designed for DIN rail mounting, it operates within an ambient air temperature range of 0 to +55°C and has a net height of 87 mm. The rated current is 18A for measuring, with safety output contacts ratings ranging from 0.1A to 5A at 24Vdc (DC-1; 120W) and 0.1A to 1.5A at 24Vdc (DC-13). Connection is made via fixed screw terminal connections. As part of the S1WP sub-range, it measures 22.5mm in width, offers an IP40 degree of protection, and requires a supply voltage of 20.4-30Vdc (24Vdc nominal). The frequency range for measurement extends up to 1kHz. Constructed with a PPO housing, it supports both single-phase (1AC) and three-phase (3AC) input types, with a measuring voltage range of 0-120Vac/dc. The unit's width is 22.5 mm, depth is 121 mm, and it consumes 2W of power. It can be stored in temperatures ranging from -40 to +85°C. The digital outputs include 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc DC-1 120W resistive load), and the analog inputs comprise 1 x analog input for current measurement (K1-UL1) and 1 x analog input for voltage measurement (L1-L3). Protection functions include underpower and overpower monitoring, with 1 x analog output for voltage (U) and current (I) monitoring.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
PILZ-827260 Pilz PILZ-827260 is a protection unit designed as a single-phase voltage monitoring relay suitable for DIN rail mounting. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. The design ensures that measuring inputs are not polarity-sensitive. It features safety output contacts ratings of 0.1A-5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15), with fixed screw terminal connections. The supply voltage requirement is 195.5-264Vac (230Vac / 240Vac nom.) under the sub-range name S1UM. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. The frequency measuring range is 0.4-400Hz, housed in a PPO material. It is designed for a single-phase (1AC) input network, with a rated voltage (AC) for measuring voltage adjustable between 0.1-500Vac/dc. The net width is 22.5 mm, and it consumes 2 VA of power with a net depth of 121 mm. Operating modes include fault latching or fault non-latching, and normally energized mode or normally de-energized mode. It can be stored in temperatures ranging from -40 to +85°C. The unit has 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load) for digital outputs, and protection functions against overvoltage with a response time of 0.1-10 s. Digital inputs consist of 1 x de-energized mode input (Y1-Y2) and 1 x latching input (Y3). | Pilz | Quick Quote | |||
PILZ-827240 Pilz PILZ-827240 is a protection unit designed for single-phase voltage monitoring with DIN rail mounting. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. The design ensures that measuring inputs are not polarity-sensitive. It features safety output contacts ratings of 0.1A-5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15), with fixed screw terminal connections. The supply voltage is between 35.7-52.8Vac (42Vac / 48Vac nominal) under the sub-range name S1UM. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. The frequency measuring range is 0.4-400Hz, housed in a PPO material. It is suitable for single-phase (1AC) input networks with a rated voltage for measuring between 0.1-500Vac/dc, adjustable. The net width is 22.5 mm, and it consumes 2 VA of power with a net depth of 121 mm. Operating modes include fault latching or non-latching, normally energized mode, or normally de-energized mode. It can be stored in temperatures ranging from -40 to +85°C. The unit has 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load) and digital inputs for de-energized mode (Y1-Y2) and latching (Y3). Protection functions cover overvoltage, with a response time of 0.1-10 s. | Pilz | Quick Quote | |||
PILZ-890170 Pilz PILZ-890170 is a protection unit designed for DIN rail mounting, featuring a phase sequence monitoring relay. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. The unit offers fixed screw terminal connections and requires a supply voltage of 200Vac-240Vac (220Vac / 230Vac nominal) within the S1PN sub-range. With dimensions of W22.5mm x D121mm and a net width of 22.5 mm, it is encased in a PPO housing that provides an IP40 degree of protection. Designed for a 3-phase (3AC) input network with a rated voltage of 200-240Vac, it consumes 8 VA of power. The operating mode is normally energized, and it includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) for digital outputs and 1 x analog input for L1-L3 voltage measurement. Its protection functions include phase sequence and phase failure. | Pilz | Quick Quote | |||
PILZ-760100 Pilz PILZ-760100 is a protection unit designed for true power monitoring and measurement, with limit values that can be adjusted via a display and stored on a chip card. It supports DIN rail mounting and operates within an ambient air temperature range of -10 to +55°C. The unit has a net height of 100 mm and accommodates a rated current of 1A-12A for measuring, with safety output contacts ratings of 0.1A-5A at 24Vdc (DC-1; 120W), 0.1A-5A at 240Vac (AC-1; 1200VA), 2A at 24Vdc (DC-13), and 5A at 230Vac (AC-15). Connection is facilitated through plug-in/detachable spring terminal connections. The supply voltage ranges from 19.2-264Vac, covering 24Vac, 110Vac, 120Vac, 220Vac, and 240Vac nominal values, and from 19.2-264Vdc, covering 24Vdc, 110Vdc, 120Vdc, 220Vdc, and 250Vdc nominal values. It falls under the PMD s10 sub-range, with dimensions of W45mm x D120mm, and offers an IP40 degree of protection. The housing is made of PC material, and it is suitable for both single-phase (1AC) and 3-phase (3AC) input networks, with a rated voltage of 100-550Vac/dc for measuring voltage. The net width is 45 mm, and it consumes 3 W of power. Operating modes include fault latching/non-latching, automatic/manual reset, and normally energized/de-energized modes. It can be stored in temperatures ranging from -25 to +85°C. The unit features 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts; 0.1-5A 24Vdc 120W DC-1 or 240Vac 1200VA AC-1 resistive load), 1 x analog input for single-phase or 3-phase voltage measurement, and protection functions against overpower, overcurrent, and undercurrent. It also includes a link terminal and a measuring circuit for digital inputs, and 1 x analog output for voltage and current measurement. | Pilz | Quick Quote | |||
PILZ-838000 Pilz PILZ-838000 is a protection unit designed for thermistor monitoring relay applications, featuring DIN rail mounting for easy installation. It operates within an ambient air temperature range of -10 to +55°C and has a net height of 87 mm. The unit is equipped with fixed screw terminal connections and requires a supply voltage of 340-440Vac, with 400Vac nominal. Part of the S1MN sub-range, it measures 22.5mm in width, has a degree of protection of IP40, and is housed in PPO material. The power consumption is rated at 3.5 VA, and the net depth is 121 mm. This protection unit offers both automatic and manual reset operating modes in a normally energized configuration. It can withstand ambient air temperatures for storage between -40 and +85°C. The unit includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) for digital outputs, 2 x analog inputs (T1-T2 measuring circuits), and features overheating protection. Additionally, it has 2 x reset circuit inputs for digital inputs and boasts a mechanical durability of 10 million operations at no load. | Pilz | Quick Quote | |||
PILZ-837305 Pilz PILZ-837305 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15), with fixed screw terminal connections. The supply voltage requirement is 195.5-253Vac (230Vac nominal) under the S3UM sub-range, with dimensions of W22.5mm and a degree of protection rated at IP40. It operates across a frequency range of 40-400Hz, encased in a PPO housing, and is designed for a 3-phase (3AC) input network with a 230Vac rated measuring voltage. The net width and depth are 22.5 mm and 122 mm, respectively, with a power consumption of 1.5 W. Operating modes include fault latching/non-latching and normally energized/de-energized modes, with an ambient air temperature range for storage between -40 and +85°C. It features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load; 0.5-10s time-delay selectable) for digital outputs, 1 x analog input for L1-L3 voltage measurement, and protection functions against undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. Digital inputs include 1 x automatic reset and 1 x switching commutation. | Pilz | Quick Quote | |||
PILZ-840775 Pilz PILZ-840775 is a protection unit designed for fault voltage monitoring relay applications. It features DIN rail mounting and operates within an ambient air temperature range of -10 to +55 °C. This unit offers fixed screw terminal connections and supports a wide supply voltage range of 19.2-264Vac, including nominal voltages of 24Vac, 110Vac, 120Vac, 220Vac, and 240Vac, as well as a DC supply voltage range of 19.2-264Vdc, with nominal voltages of 24Vdc, 110Vdc, 120Vdc, 220Vdc, and 250Vdc. The PFU6 sub-range model comes with an IP40 degree of protection and is capable of handling frequencies from 50 to 1000Hz. It has a rated voltage for AC and DC measuring voltage up to 690Vac/dc and consumes 2W of power. For storage, it can withstand ambient air temperatures from -40 to +85 °C. The unit includes 1 auxiliary output with SPDT-NO/NC contacts and 6 analog inputs for various measuring circuits. It also features overvoltage protection functions, along with 1 reset input and 1 test input for digital interfacing. | Pilz | Quick Quote | |||
PILZ-828030 Pilz PILZ-828030 is a protection unit designed for current monitoring relay applications, featuring DIN rail mounting for easy installation. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. This unit supports a rated current from 0.01 to 15A for measuring current and utilizes fixed screw terminal connections. It is supplied with a voltage range of 110Vac to 127Vac (120Vac nominal) under the sub-range name S1IM. The dimensions include a width of 22.5mm and a degree of protection rated at IP40, with a frequency measuring range of 40-400Hz. Constructed with a PPO housing, it is designed for single-phase (1AC) input networks and has a net width of 22.5 mm. The power consumption is minimal at 2 VA, and the net depth is 121 mm. It offers versatile operating modes including fault latching/non-latching and normally energized/de-energized modes. The ambient air temperature for storage extends from -40 to +85°C. It features 1 x auxiliary output (SPDT-NO/NC contacts) for digital outputs, and protection functions against overcurrent. Digital inputs include 1 x latching/non-latching input, 1 x energized/de-energized mode input, and 1 x measuring range input for enhanced flexibility in application. | Pilz | Quick Quote | |||
PILZ-890200 Pilz PILZ-890200 | Pilz | Quick Quote | |||
PILZ-890071 Pilz PILZ-890071 is a protection unit designed for true power monitoring with a relay function. It features nine different measuring ranges, allowing for adjustable switching underload and overload thresholds. The unit also offers adjustable monitoring reaction time and start-up suppression time for tailored operation. Designed for DIN rail mounting, it operates within an ambient air temperature range of 0 to +55°C and has a net height of 87 mm. The rated current is 18A for measuring, with safety output contacts ratings ranging from 0.1A to 5A at 24Vdc (DC-1; 120W) and 0.1A to 1.5A at 24Vdc (DC-13). Connection is made via fixed screw terminal connections. As part of the S1WP sub-range, it measures 22.5mm in width, offers an IP40 degree of protection, and requires a supply voltage of 20.4-30Vdc (24Vdc nominal). The frequency range for measurement extends up to 1kHz. Constructed with a PPO housing, it supports both single-phase (1AC) and three-phase (3AC) input types, with a measuring voltage range of 0-120Vac/dc. The unit's width is 22.5 mm, depth is 121 mm, and it consumes 2W of power. It can be stored in temperatures ranging from -40 to +85°C. The digital outputs include 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc DC-1 120W resistive load), and the analog inputs comprise 1 x analog input for current measurement (K1-UL1) and 1 x analog input for voltage measurement (L1-L3). Protection functions include underpower and overpower monitoring, with 1 x analog output for voltage (U) and current (I) monitoring. | Pilz | Quick Quote |