Pilz PILZ-890060 is a protection unit designed for true power monitoring with a relay that supports 9 different measuring ranges. It features adjustable switching for underload and overload thresholds, along with customizable monitoring reaction time and start-up suppression time. This unit is suitable for DIN rail mounting and operates within an ambient air temperature range of 0 to +55°C. It has a net height of 87 mm and is capable of handling a rated current of 9A for measuring, with safety output contacts ratings ranging from 0.1A to 5A at 24Vdc (DC-1; 120W) and 240Vac (AC-1; 1200VA), and lower ratings for DC-13 and AC-15 applications. The connection type is fixed screw terminals, and it accepts a supply voltage of 27.5-264.5Vac for various nominal voltages, as well as a DC supply voltage range of 93.5-287.5Vdc. The unit operates within a frequency range of 0-1kHz for measuring, is housed in PPO material, and can be used with both single-phase and 3-phase input networks. The rated voltage for measuring is up to 550Vac/dc, with a net width of 22.5 mm and a depth of 121 mm. It has a power consumption of 5 VA, an IP40 degree of protection, and is designed for storage in temperatures ranging from -40 to +85°C. The unit includes 1 x auxiliary output (SPDT-NO/NC contacts) for resistive loads, 1 x analog input for current measurement, 1 x analog input for voltage measurement, and 1 x analog output for voltage and current signaling, with underpower and overpower protection functions.
Quick Quote
Pilz PILZ-890000 is an insulation monitor designed for DIN rail mounting, featuring insulation monitoring relay, insulation monitoring, earth fault monitoring, and a test mode. It operates within an ambient air temperature range of -10 to +55°C and has a net height of 87 mm. The device supports rated current safety output contacts ratings from 0.1A to 5A for both 24Vdc (DC-1; 120W) and 240Vac (AC-1; 1200VA), along with 1.5A for 24Vdc (DC-13) and 2A for 230Vac (AC-15). Connection is established via fixed screw terminal connections. The supply voltage ranges from 24Vac to 240Vac (with nominal voltages of 110Vac, 220Vac, 230Vac) and from 24Vdc to 240Vdc (with nominal voltages of 110Vdc, 120Vdc, 220Vdc). It belongs to the S1EN sub-range, measures 22.5mm in width, and offers a degree of protection of IP40. The housing is made of PPO material, and it can handle rated voltages up to 400Vac. The net width is 22.5 mm, and it consumes 1 W of power, with a net depth of 121 mm. Operating modes include automatic reset/manual reset and normally energized mode. It can be stored in temperatures ranging from -40 to +85°C. The device includes 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc 120W DC-1 or 240Vac 1200VA AC-1 resistive load), protection functions against overcurrent, and digital inputs for main voltage (42-240Vac and 24Vdc) and a reset input.
Quick Quote
Pilz PILZ-840630 is a protection unit designed for thermistor monitoring relay applications, featuring thermistor monitoring as its main function. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -10 to +55 °C. This unit has a net height of 87 mm and incorporates a manual reset design with fixed screw terminal connections. It requires a supply voltage of 204-264Vac (240Vac nominal) and falls under the S1MO sub-range. The dimensions include a width of 22.5mm and a depth of 121 mm, offering a degree of protection of IP40. The housing is made of PPO material, ensuring durability. With a power consumption of 3.5 VA, this unit operates in a normally energized mode with manual reset functionality. It can withstand an ambient air temperature for storage between -40 and +85 °C. The PILZ-840630 features 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) for digital outputs, 2 x analog inputs (T1-T2 measuring circuits) for monitoring, and is equipped with 2 x reset circuit inputs (X2-X1) for digital inputs. Its protection functions are specifically designed for overheating protection, utilizing thermistors to safeguard against temperature-related issues.
Quick Quote
Pilz PILZ-840760 is a protection unit designed for thermistor monitoring relay thermistor monitoring, featuring DIN rail mounting for ease of installation. It operates within an ambient air temperature range of -10 to +55°C and has a net height of 87 mm. This unit is equipped with an automatic reset design and fixed screw terminal connections for secure wiring. It requires a supply voltage of 204-264Vac (240Vac nominal) and falls under the S1MS sub-range. With dimensions of W22.5mm x D121mm and a net width of 22.5 mm, it offers a compact solution for protection needs. The PILZ-840760 has an IP40 degree of protection, is housed in PPO material, and consumes 3.5 VA of power. Its operating mode is automatic reset in a normally energized mode. The unit includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) and 2 x analog inputs (T1-T2 measuring circuits) for comprehensive monitoring. It is specifically designed for overheating protection through thermistor monitoring.
Quick Quote
Pilz PILZ-840655 is a protection unit designed for thermistor monitoring relay applications, featuring thermistor monitoring as its main function. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -10 to +55°C. This unit has a net height of 87 mm and is designed with an automatic reset function. It utilizes fixed screw terminal connections for secure installation and requires a supply voltage of 40.8-52.8Vac, with 48Vac nominal. The S1MS sub-range model comes in dimensions of W22.5mm, offering a degree of protection rated at IP40. The housing is made from PPO material, ensuring durability, with a net width of 22.5 mm and a net depth of 121 mm. It consumes 3.5 VA of power and operates in an automatic reset, normally energized mode. The unit includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) for digital outputs and 2 x analog inputs (T1-T2 measuring circuits) for comprehensive monitoring capabilities. Its protection functions are specifically designed for overheating protection, utilizing thermistor technology.
Quick Quote
Pilz PILZ-837380 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15). Connection is facilitated through fixed screw terminal connections. The supply voltage requirement is 195.5-253Vac (230Vac nominal) within the S3UM sub-range. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. It operates across a frequency range of 40-400Hz and is housed in a PPO material. The type of network input is 3-phase (3AC) with a rated voltage for measuring at 500/550Vac. The net width and depth are 22.5 mm and 122 mm, respectively, with a power consumption of 1.5 W. Operating modes include fault latching/non-latching and normally energized/de-energized modes. The unit can be stored within an ambient air temperature range of -40 to +85°C. It features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load; 0.5-10s time-delay selectable) for digital outputs, 1 x analog input for L1-L3 voltage measurement, and protection functions against undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. Digital inputs include 1 x automatic reset and 1 x switching commutation.
Quick Quote
Pilz PILZ-837251 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 24Vdc (DC-1; 120W) and 1.5A at 24Vdc (DC-13). Connection is facilitated through fixed screw terminal connections. As part of the S3UM sub-range, it measures 22.5mm in width, offers an IP40 degree of protection, and requires a supply voltage of 20.4-26.4Vdc (24Vdc nominal) with a frequency measuring range of 40-400Hz. The housing is made from PPO material, and the unit is designed for a 3-phase (3AC) input network with a 230Vac measuring voltage. It has a net width of 22.5 mm, a power consumption of 1.5 W, and a net depth of 122 mm. Operating modes include fault latching/non-latching and normally energized/de-energized modes. The unit can be stored in temperatures ranging from -40 to +85°C. It features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc DC-1 resistive load; 0.5-10s time-delay selectable (ON-delay energization)), 1 x analog input (L1-L3 voltage measurement), and digital inputs for 1 x automatic reset (Y1-Y2 linked) and 1 x switching commutation (Y2-Y3). Protection functions cover undervoltage, overvoltage, phase sequence, phase failure, and asymmetry.
Quick Quote
Pilz PILZ-828040 is a protection unit designed for current monitoring relay applications, featuring DIN rail mounting for easy installation. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. This unit is capable of measuring currents from 0.01 to 15A and offers fixed screw terminal connections. It requires a supply voltage of 230Vac-240Vac and falls under the S1IM sub-range. With dimensions of W22.5mm and a degree of protection rated at IP40, it is suitable for various environments. The frequency measuring range is 40-400Hz, and it is housed in a PPO material, ensuring durability. Designed for single-phase (1AC) input networks, it has a net width of 22.5 mm and a depth of 121 mm. Power consumption is minimal at 2 VA. The operating modes include fault latching/non-latching and normally energized/de-energized modes, accommodating different application requirements. Storage temperature tolerance ranges from -40 to +85°C. It features 1 x auxiliary output (SPDT-NO/NC contacts) for digital outputs, and digital inputs include 1 x latching/non-latching input, 1 x energized/de-energized mode input, and 1 x measuring range input, supporting overcurrent protection functions.
Quick Quote
Pilz PILZ-827265 is a protection unit designed for current monitoring relay applications, featuring DIN rail mounting for ease of installation. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. This unit is capable of measuring currents ranging from 0.01 to 15A and is equipped with fixed screw terminal connections. It requires a supply voltage of 24Vac and falls under the S1IM sub-range. With dimensions of W22.5mm x D121 mm and a net width of 22.5 mm, it offers a compact solution. The PILZ-827265 is designed with an IP40 degree of protection and operates across a frequency measuring range of 40-400Hz. Its housing is made from PPO material, ensuring durability. This single-phase (1AC) input unit has a power consumption of 2 VA and features multiple operating modes including fault latching/non-latching and normally energized/de-energized modes. It can withstand an ambient air temperature for storage between -40 and +85°C. Additionally, it includes 1 x auxiliary output (SPDT-NO/NC contacts) for digital outputs, and its protection functions cover overcurrent scenarios. Digital inputs comprise 1 x latching/non-latching input, 1 x energized/de-energized mode input, and 1 x measuring range input, offering flexibility in monitoring and control.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
PILZ-890060 Pilz PILZ-890060 is a protection unit designed for true power monitoring with a relay that supports 9 different measuring ranges. It features adjustable switching for underload and overload thresholds, along with customizable monitoring reaction time and start-up suppression time. This unit is suitable for DIN rail mounting and operates within an ambient air temperature range of 0 to +55°C. It has a net height of 87 mm and is capable of handling a rated current of 9A for measuring, with safety output contacts ratings ranging from 0.1A to 5A at 24Vdc (DC-1; 120W) and 240Vac (AC-1; 1200VA), and lower ratings for DC-13 and AC-15 applications. The connection type is fixed screw terminals, and it accepts a supply voltage of 27.5-264.5Vac for various nominal voltages, as well as a DC supply voltage range of 93.5-287.5Vdc. The unit operates within a frequency range of 0-1kHz for measuring, is housed in PPO material, and can be used with both single-phase and 3-phase input networks. The rated voltage for measuring is up to 550Vac/dc, with a net width of 22.5 mm and a depth of 121 mm. It has a power consumption of 5 VA, an IP40 degree of protection, and is designed for storage in temperatures ranging from -40 to +85°C. The unit includes 1 x auxiliary output (SPDT-NO/NC contacts) for resistive loads, 1 x analog input for current measurement, 1 x analog input for voltage measurement, and 1 x analog output for voltage and current signaling, with underpower and overpower protection functions. | Pilz | Quick Quote | |||
PILZ-890000 Pilz PILZ-890000 is an insulation monitor designed for DIN rail mounting, featuring insulation monitoring relay, insulation monitoring, earth fault monitoring, and a test mode. It operates within an ambient air temperature range of -10 to +55°C and has a net height of 87 mm. The device supports rated current safety output contacts ratings from 0.1A to 5A for both 24Vdc (DC-1; 120W) and 240Vac (AC-1; 1200VA), along with 1.5A for 24Vdc (DC-13) and 2A for 230Vac (AC-15). Connection is established via fixed screw terminal connections. The supply voltage ranges from 24Vac to 240Vac (with nominal voltages of 110Vac, 220Vac, 230Vac) and from 24Vdc to 240Vdc (with nominal voltages of 110Vdc, 120Vdc, 220Vdc). It belongs to the S1EN sub-range, measures 22.5mm in width, and offers a degree of protection of IP40. The housing is made of PPO material, and it can handle rated voltages up to 400Vac. The net width is 22.5 mm, and it consumes 1 W of power, with a net depth of 121 mm. Operating modes include automatic reset/manual reset and normally energized mode. It can be stored in temperatures ranging from -40 to +85°C. The device includes 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc 120W DC-1 or 240Vac 1200VA AC-1 resistive load), protection functions against overcurrent, and digital inputs for main voltage (42-240Vac and 24Vdc) and a reset input. | Pilz | Quick Quote | |||
PILZ-840630 Pilz PILZ-840630 is a protection unit designed for thermistor monitoring relay applications, featuring thermistor monitoring as its main function. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -10 to +55 °C. This unit has a net height of 87 mm and incorporates a manual reset design with fixed screw terminal connections. It requires a supply voltage of 204-264Vac (240Vac nominal) and falls under the S1MO sub-range. The dimensions include a width of 22.5mm and a depth of 121 mm, offering a degree of protection of IP40. The housing is made of PPO material, ensuring durability. With a power consumption of 3.5 VA, this unit operates in a normally energized mode with manual reset functionality. It can withstand an ambient air temperature for storage between -40 and +85 °C. The PILZ-840630 features 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) for digital outputs, 2 x analog inputs (T1-T2 measuring circuits) for monitoring, and is equipped with 2 x reset circuit inputs (X2-X1) for digital inputs. Its protection functions are specifically designed for overheating protection, utilizing thermistors to safeguard against temperature-related issues. | Pilz | Quick Quote | |||
PILZ-490192 Pilz PILZ-490192 | Pilz | Quick Quote | |||
PILZ-840760 Pilz PILZ-840760 is a protection unit designed for thermistor monitoring relay thermistor monitoring, featuring DIN rail mounting for ease of installation. It operates within an ambient air temperature range of -10 to +55°C and has a net height of 87 mm. This unit is equipped with an automatic reset design and fixed screw terminal connections for secure wiring. It requires a supply voltage of 204-264Vac (240Vac nominal) and falls under the S1MS sub-range. With dimensions of W22.5mm x D121mm and a net width of 22.5 mm, it offers a compact solution for protection needs. The PILZ-840760 has an IP40 degree of protection, is housed in PPO material, and consumes 3.5 VA of power. Its operating mode is automatic reset in a normally energized mode. The unit includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) and 2 x analog inputs (T1-T2 measuring circuits) for comprehensive monitoring. It is specifically designed for overheating protection through thermistor monitoring. | Pilz | Quick Quote | |||
PILZ-840655 Pilz PILZ-840655 is a protection unit designed for thermistor monitoring relay applications, featuring thermistor monitoring as its main function. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -10 to +55°C. This unit has a net height of 87 mm and is designed with an automatic reset function. It utilizes fixed screw terminal connections for secure installation and requires a supply voltage of 40.8-52.8Vac, with 48Vac nominal. The S1MS sub-range model comes in dimensions of W22.5mm, offering a degree of protection rated at IP40. The housing is made from PPO material, ensuring durability, with a net width of 22.5 mm and a net depth of 121 mm. It consumes 3.5 VA of power and operates in an automatic reset, normally energized mode. The unit includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) for digital outputs and 2 x analog inputs (T1-T2 measuring circuits) for comprehensive monitoring capabilities. Its protection functions are specifically designed for overheating protection, utilizing thermistor technology. | Pilz | Quick Quote | |||
PILZ-837380 Pilz PILZ-837380 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15). Connection is facilitated through fixed screw terminal connections. The supply voltage requirement is 195.5-253Vac (230Vac nominal) within the S3UM sub-range. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. It operates across a frequency range of 40-400Hz and is housed in a PPO material. The type of network input is 3-phase (3AC) with a rated voltage for measuring at 500/550Vac. The net width and depth are 22.5 mm and 122 mm, respectively, with a power consumption of 1.5 W. Operating modes include fault latching/non-latching and normally energized/de-energized modes. The unit can be stored within an ambient air temperature range of -40 to +85°C. It features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load; 0.5-10s time-delay selectable) for digital outputs, 1 x analog input for L1-L3 voltage measurement, and protection functions against undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. Digital inputs include 1 x automatic reset and 1 x switching commutation. | Pilz | Quick Quote | |||
PILZ-837251 Pilz PILZ-837251 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 24Vdc (DC-1; 120W) and 1.5A at 24Vdc (DC-13). Connection is facilitated through fixed screw terminal connections. As part of the S3UM sub-range, it measures 22.5mm in width, offers an IP40 degree of protection, and requires a supply voltage of 20.4-26.4Vdc (24Vdc nominal) with a frequency measuring range of 40-400Hz. The housing is made from PPO material, and the unit is designed for a 3-phase (3AC) input network with a 230Vac measuring voltage. It has a net width of 22.5 mm, a power consumption of 1.5 W, and a net depth of 122 mm. Operating modes include fault latching/non-latching and normally energized/de-energized modes. The unit can be stored in temperatures ranging from -40 to +85°C. It features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc DC-1 resistive load; 0.5-10s time-delay selectable (ON-delay energization)), 1 x analog input (L1-L3 voltage measurement), and digital inputs for 1 x automatic reset (Y1-Y2 linked) and 1 x switching commutation (Y2-Y3). Protection functions cover undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. | Pilz | Quick Quote | |||
PILZ-828040 Pilz PILZ-828040 is a protection unit designed for current monitoring relay applications, featuring DIN rail mounting for easy installation. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. This unit is capable of measuring currents from 0.01 to 15A and offers fixed screw terminal connections. It requires a supply voltage of 230Vac-240Vac and falls under the S1IM sub-range. With dimensions of W22.5mm and a degree of protection rated at IP40, it is suitable for various environments. The frequency measuring range is 40-400Hz, and it is housed in a PPO material, ensuring durability. Designed for single-phase (1AC) input networks, it has a net width of 22.5 mm and a depth of 121 mm. Power consumption is minimal at 2 VA. The operating modes include fault latching/non-latching and normally energized/de-energized modes, accommodating different application requirements. Storage temperature tolerance ranges from -40 to +85°C. It features 1 x auxiliary output (SPDT-NO/NC contacts) for digital outputs, and digital inputs include 1 x latching/non-latching input, 1 x energized/de-energized mode input, and 1 x measuring range input, supporting overcurrent protection functions. | Pilz | Quick Quote | |||
PILZ-827265 Pilz PILZ-827265 is a protection unit designed for current monitoring relay applications, featuring DIN rail mounting for ease of installation. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. This unit is capable of measuring currents ranging from 0.01 to 15A and is equipped with fixed screw terminal connections. It requires a supply voltage of 24Vac and falls under the S1IM sub-range. With dimensions of W22.5mm x D121 mm and a net width of 22.5 mm, it offers a compact solution. The PILZ-827265 is designed with an IP40 degree of protection and operates across a frequency measuring range of 40-400Hz. Its housing is made from PPO material, ensuring durability. This single-phase (1AC) input unit has a power consumption of 2 VA and features multiple operating modes including fault latching/non-latching and normally energized/de-energized modes. It can withstand an ambient air temperature for storage between -40 and +85°C. Additionally, it includes 1 x auxiliary output (SPDT-NO/NC contacts) for digital outputs, and its protection functions cover overcurrent scenarios. Digital inputs comprise 1 x latching/non-latching input, 1 x energized/de-energized mode input, and 1 x measuring range input, offering flexibility in monitoring and control. | Pilz | Quick Quote |