Manufacturer
Pilz
Pilz

Found 79 products

Pilz

Pilz PILZ-828040 is a protection unit designed for current monitoring relay applications, featuring DIN rail mounting for easy installation. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. This unit is capable of measuring currents from 0.01 to 15A and offers fixed screw terminal connections. It requires a supply voltage of 230Vac-240Vac and falls under the S1IM sub-range. With dimensions of W22.5mm and a degree of protection rated at IP40, it is suitable for various environments. The frequency measuring range is 40-400Hz, and it is housed in a PPO material, ensuring durability. Designed for single-phase (1AC) input networks, it has a net width of 22.5 mm and a depth of 121 mm. Power consumption is minimal at 2 VA. The operating modes include fault latching/non-latching and normally energized/de-energized modes, accommodating different application requirements. Storage temperature tolerance ranges from -40 to +85°C. It features 1 x auxiliary output (SPDT-NO/NC contacts) for digital outputs, and digital inputs include 1 x latching/non-latching input, 1 x energized/de-energized mode input, and 1 x measuring range input, supporting overcurrent protection functions.

Quick Quote

Pilz

Pilz PILZ-827265 is a protection unit designed for current monitoring relay applications, featuring DIN rail mounting for ease of installation. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. This unit is capable of measuring currents ranging from 0.01 to 15A and is equipped with fixed screw terminal connections. It requires a supply voltage of 24Vac and falls under the S1IM sub-range. With dimensions of W22.5mm x D121 mm and a net width of 22.5 mm, it offers a compact solution. The PILZ-827265 is designed with an IP40 degree of protection and operates across a frequency measuring range of 40-400Hz. Its housing is made from PPO material, ensuring durability. This single-phase (1AC) input unit has a power consumption of 2 VA and features multiple operating modes including fault latching/non-latching and normally energized/de-energized modes. It can withstand an ambient air temperature for storage between -40 and +85°C. Additionally, it includes 1 x auxiliary output (SPDT-NO/NC contacts) for digital outputs, and its protection functions cover overcurrent scenarios. Digital inputs comprise 1 x latching/non-latching input, 1 x energized/de-energized mode input, and 1 x measuring range input, offering flexibility in monitoring and control.

Quick Quote

Pilz

Pilz PILZ-827230 is a protection unit designed as a single-phase voltage monitoring relay suitable for DIN rail mounting. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. The unit features safety output contacts ratings of 0.1A-5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15), with fixed screw terminal connections. The supply voltage (AC) is specified at 35.7-52.8Vac (42Vac / 48Vac nominal) within the S1UM sub-range. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. The frequency measuring range is 0.4-400Hz, and the housing is made of PPO material. It is designed for single-phase (1AC) input networks with a rated voltage (AC) of 0.1-500Vac/dc (adjustable). The net width is 22.5 mm, and the power consumption is 2 VA, with a net depth of 121 mm. Operating modes include fault latching / fault non-latching, normally energized mode / normally de-energized mode. The ambient air temperature for storage ranges from -40 to +85°C. It features 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load), overvoltage protection functions, a response time of 0.1-10 s, and digital inputs for de-energized mode (Y1-Y2) and latching (Y3).

Quick Quote

Pilz

Pilz PILZ-407710 is a protection unit designed for true power monitoring and conversion, equipped with measuring equipment for rated power and true power. It features DIN rail mounting for easy installation and operates within an ambient air temperature range of 0 to +60 °C. The unit has a net height of 90 mm and is designed for a 400Vac measuring voltage with a rated current of 0-6A. Connection is facilitated through plug-in/detachable spring terminal connections. As part of the P3WP3P sub-range, it measures 94mm in width and 121mm in depth, offering an IP20 degree of protection. The supply voltage requirement is 20.4-26.4Vdc, with a nominal 24Vdc, and it consumes 2.5 W of power. Constructed from resin, this unit is suitable for 3-phase (3AC) input networks with a rated voltage of 400Vac. It features three digital power/voltage outputs (AN1; AN2; AN3; GND) and three analog inputs for voltage measurement across first, second, and third loads (L11-L21-L31 / L12-L22-L32). Protection functions include overpower protection, and it also provides three analog current outputs (V1-W1; V2-W2; V3-W3) for comprehensive monitoring and control. The unit is designed to withstand ambient air temperatures for storage ranging from -40 to +85 °C.

Quick Quote

Pilz

Pilz PILZ-890170 is a protection unit designed for DIN rail mounting, featuring a phase sequence monitoring relay. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. The unit offers fixed screw terminal connections and requires a supply voltage of 200Vac-240Vac (220Vac / 230Vac nominal) within the S1PN sub-range. With dimensions of W22.5mm x D121mm and a net width of 22.5 mm, it is encased in a PPO housing that provides an IP40 degree of protection. Designed for a 3-phase (3AC) input network with a rated voltage of 200-240Vac, it consumes 8 VA of power. The operating mode is normally energized, and it includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) for digital outputs and 1 x analog input for L1-L3 voltage measurement. Its protection functions include phase sequence and phase failure.

Quick Quote

Pilz

Pilz PILZ-760100 is a protection unit designed for true power monitoring and measurement, with limit values that can be adjusted via a display and stored on a chip card. It supports DIN rail mounting and operates within an ambient air temperature range of -10 to +55°C. The unit has a net height of 100 mm and accommodates a rated current of 1A-12A for measuring, with safety output contacts ratings of 0.1A-5A at 24Vdc (DC-1; 120W), 0.1A-5A at 240Vac (AC-1; 1200VA), 2A at 24Vdc (DC-13), and 5A at 230Vac (AC-15). Connection is facilitated through plug-in/detachable spring terminal connections. The supply voltage ranges from 19.2-264Vac, covering 24Vac, 110Vac, 120Vac, 220Vac, and 240Vac nominal values, and from 19.2-264Vdc, covering 24Vdc, 110Vdc, 120Vdc, 220Vdc, and 250Vdc nominal values. It falls under the PMD s10 sub-range, with dimensions of W45mm x D120mm, and offers an IP40 degree of protection. The housing is made of PC material, and it is suitable for both single-phase (1AC) and 3-phase (3AC) input networks, with a rated voltage of 100-550Vac/dc for measuring voltage. The net width is 45 mm, and it consumes 3 W of power. Operating modes include fault latching/non-latching, automatic/manual reset, and normally energized/de-energized modes. It can be stored in temperatures ranging from -25 to +85°C. The unit features 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts; 0.1-5A 24Vdc 120W DC-1 or 240Vac 1200VA AC-1 resistive load), 1 x analog input for single-phase or 3-phase voltage measurement, and protection functions against overpower, overcurrent, and undercurrent. It also includes a link terminal and a measuring circuit for digital inputs, and 1 x analog output for voltage and current measurement.

Quick Quote

Pilz

Pilz PILZ-890150 is a protection unit designed for true power monitoring with a relay that supports 9 different measuring ranges. It features adjustable switching for underload and overload thresholds, along with customizable monitoring reaction time and start-up suppression time. This unit is suitable for DIN rail mounting and operates within an ambient air temperature range of 0 to +55°C. It has a net height of 87 mm and is rated for an 18A measuring current. The safety output contacts ratings vary from 0.1A to 5A at 24Vdc (DC-1; 120W) and 240Vac (AC-1; 1200VA), to 0.1A-1.5A at 24Vdc (DC-13) and 0.1A-1.8A at 230Vac (AC-15). Connection is established via fixed screw terminal connections. The supply voltage can range from 27.5-264.5Vac for AC and 93.5-287.5Vdc for DC, covering nominal voltages of 110Vac/120Vac/220Vac/230Vac and 110Vdc/120Vdc/220Vdc/250Vdc respectively. The S1WP sub-range model has dimensions of W22.5mm, with a degree of protection rated at IP40. It can handle a frequency measuring range of 0-1kHz and is constructed with a PPO housing. This unit is designed for both single-phase (1AC) and 3-phase (3AC) input networks, with a rated voltage for AC measuring voltage up to 415Vac/dc. The net width and depth are 22.5 mm and 121 mm, respectively, with a power consumption of 5 VA. It is capable of storage in ambient air temperatures ranging from -40 to +85°C. The digital outputs include 1 x auxiliary output (SPDT-NO/NC contacts) suitable for resistive loads, and it features 1 x analog input for current measurement and 1 x analog input for voltage measurement. The protection functions include underpower and overpower monitoring, complemented by 1 x analog output for voltage and current monitoring.

Quick Quote

Pilz

Pilz PILZ-890120 is a protection unit designed for true power monitoring with a relay that supports 9 different measuring ranges. It features adjustable switching for underload and overload thresholds, along with customizable monitoring reaction time and start-up suppression time. This unit is suitable for DIN rail mounting and operates within an ambient air temperature range of 0 to +55°C. It has a net height of 87 mm and is rated for an 18A measuring current. The safety output contacts ratings vary from 0.1A to 5A at 24Vdc (DC-1; 120W) and 240Vac (AC-1; 1200VA), with lower ratings for DC-13 and AC-15 applications. Connection is established via fixed screw terminal connections. The supply voltage can range from 27.5-264.5Vac for AC and 93.5-287.5Vdc for DC, covering standard nominal voltages. The S1WP sub-range model has dimensions of W22.5mm, a degree of protection of IP40, and operates within a frequency of 0-1kHz for its measuring range. Constructed with a PPO housing, it is designed for both single-phase (1AC) and 3-phase (3AC) input networks, with a rated voltage of 0-120Vac/dc for measuring voltage. The unit's net width and depth are 22.5 mm and 121 mm, respectively, and it has a power consumption of 5 VA. It can be stored in temperatures ranging from -40 to +85°C. The digital outputs include 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc 120W DC-1 or 240Vac 1200VA AC-1 resistive load), and it features 1 x analog input for current measurement and 1 x analog input for voltage measurement. Protection functions include underpower and overpower monitoring, complemented by 1 x analog output for voltage and current monitoring.

Quick Quote

Pilz

Pilz PILZ-890050 is a protection unit designed for true power monitoring with a relay function. It features nine different measuring ranges, adjustable switching thresholds for underload and overload conditions, and customizable monitoring reaction and start-up suppression times. This unit is suitable for DIN rail mounting and operates within an ambient air temperature range of 0 to +55°C. It has a net height of 87 mm and supports a rated current of 9A for measuring, with safety output contacts ratings ranging from 0.1A to 5A at 24Vdc (DC-1; 120W) and 240Vac (AC-1; 1200VA), and lower ratings for DC-13 and AC-15 applications. The connection type is fixed screw terminals, and it accepts a supply voltage of 27.5-264.5Vac for AC and 93.5-287.5Vdc for DC, covering a wide range of nominal voltages. The S1WP sub-range unit has dimensions of W22.5mm, a degree of protection of IP40, and operates within a frequency range of 0-1kHz. Constructed with a PPO housing, it is designed for both single-phase and 3-phase input networks, with a rated voltage measuring capacity of 0-415Vac/dc. The net width is 22.5 mm, and it consumes 5 VA of power. It has a net depth of 121 mm and can be stored in temperatures ranging from -40 to +85°C. The unit includes one auxiliary output (SPDT-NO/NC contacts) for resistive loads and two analog inputs for current and voltage measurement, alongside one analog output for voltage and current signaling. It is equipped with underpower and overpower protection functions.

Quick Quote

Pilz

Pilz PILZ-839770 is a protection unit designed for thermistor monitoring relay applications, featuring DIN rail mounting for easy installation. It operates within an ambient air temperature range of -10 to +55°C and has a net height of 87 mm. The unit offers fixed screw terminal connections and supports a supply voltage range of 20.4-26.4Vac (24Vac nominal) and 20.4-26.4Vdc (24Vdc nominal), belonging to the S1MN sub-range. With dimensions of W22.5mm and a degree of protection rated at IP40, it is housed in a PPO material casing. The PILZ-839770 has a net width of 22.5 mm, a depth of 121 mm, and consumes 2 W of power. It features an operating mode that allows for automatic reset or manual reset in a normally energized mode. The unit is designed to withstand ambient air temperatures for storage between -40 and +85°C. It includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) for digital outputs, 2 x analog inputs (T1-T2 measuring circuits) for monitoring, and offers protection functions against overheating with its thermistor. Additionally, it has 2 x reset circuit inputs (X2-X1) for digital inputs and boasts a mechanical durability of 10 million operations at no load.

Quick Quote

ItemManufacturerPriceStockDelivery

PILZ-828040

Pilz PILZ-828040 is a protection unit designed for current monitoring relay applications, featuring DIN rail mounting for easy installation. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. This unit is capable of measuring currents from 0.01 to 15A and offers fixed screw terminal connections. It requires a supply voltage of 230Vac-240Vac and falls under the S1IM sub-range. With dimensions of W22.5mm and a degree of protection rated at IP40, it is suitable for various environments. The frequency measuring range is 40-400Hz, and it is housed in a PPO material, ensuring durability. Designed for single-phase (1AC) input networks, it has a net width of 22.5 mm and a depth of 121 mm. Power consumption is minimal at 2 VA. The operating modes include fault latching/non-latching and normally energized/de-energized modes, accommodating different application requirements. Storage temperature tolerance ranges from -40 to +85°C. It features 1 x auxiliary output (SPDT-NO/NC contacts) for digital outputs, and digital inputs include 1 x latching/non-latching input, 1 x energized/de-energized mode input, and 1 x measuring range input, supporting overcurrent protection functions.

Pilz

Quick Quote

PILZ-827265

Pilz PILZ-827265 is a protection unit designed for current monitoring relay applications, featuring DIN rail mounting for ease of installation. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. This unit is capable of measuring currents ranging from 0.01 to 15A and is equipped with fixed screw terminal connections. It requires a supply voltage of 24Vac and falls under the S1IM sub-range. With dimensions of W22.5mm x D121 mm and a net width of 22.5 mm, it offers a compact solution. The PILZ-827265 is designed with an IP40 degree of protection and operates across a frequency measuring range of 40-400Hz. Its housing is made from PPO material, ensuring durability. This single-phase (1AC) input unit has a power consumption of 2 VA and features multiple operating modes including fault latching/non-latching and normally energized/de-energized modes. It can withstand an ambient air temperature for storage between -40 and +85°C. Additionally, it includes 1 x auxiliary output (SPDT-NO/NC contacts) for digital outputs, and its protection functions cover overcurrent scenarios. Digital inputs comprise 1 x latching/non-latching input, 1 x energized/de-energized mode input, and 1 x measuring range input, offering flexibility in monitoring and control.

Pilz

Quick Quote

PILZ-827230

Pilz PILZ-827230 is a protection unit designed as a single-phase voltage monitoring relay suitable for DIN rail mounting. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. The unit features safety output contacts ratings of 0.1A-5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15), with fixed screw terminal connections. The supply voltage (AC) is specified at 35.7-52.8Vac (42Vac / 48Vac nominal) within the S1UM sub-range. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. The frequency measuring range is 0.4-400Hz, and the housing is made of PPO material. It is designed for single-phase (1AC) input networks with a rated voltage (AC) of 0.1-500Vac/dc (adjustable). The net width is 22.5 mm, and the power consumption is 2 VA, with a net depth of 121 mm. Operating modes include fault latching / fault non-latching, normally energized mode / normally de-energized mode. The ambient air temperature for storage ranges from -40 to +85°C. It features 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load), overvoltage protection functions, a response time of 0.1-10 s, and digital inputs for de-energized mode (Y1-Y2) and latching (Y3).

Pilz

Quick Quote

PILZ-407710

Pilz PILZ-407710 is a protection unit designed for true power monitoring and conversion, equipped with measuring equipment for rated power and true power. It features DIN rail mounting for easy installation and operates within an ambient air temperature range of 0 to +60 °C. The unit has a net height of 90 mm and is designed for a 400Vac measuring voltage with a rated current of 0-6A. Connection is facilitated through plug-in/detachable spring terminal connections. As part of the P3WP3P sub-range, it measures 94mm in width and 121mm in depth, offering an IP20 degree of protection. The supply voltage requirement is 20.4-26.4Vdc, with a nominal 24Vdc, and it consumes 2.5 W of power. Constructed from resin, this unit is suitable for 3-phase (3AC) input networks with a rated voltage of 400Vac. It features three digital power/voltage outputs (AN1; AN2; AN3; GND) and three analog inputs for voltage measurement across first, second, and third loads (L11-L21-L31 / L12-L22-L32). Protection functions include overpower protection, and it also provides three analog current outputs (V1-W1; V2-W2; V3-W3) for comprehensive monitoring and control. The unit is designed to withstand ambient air temperatures for storage ranging from -40 to +85 °C.

Pilz

Quick Quote

PILZ-890170

Pilz PILZ-890170 is a protection unit designed for DIN rail mounting, featuring a phase sequence monitoring relay. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. The unit offers fixed screw terminal connections and requires a supply voltage of 200Vac-240Vac (220Vac / 230Vac nominal) within the S1PN sub-range. With dimensions of W22.5mm x D121mm and a net width of 22.5 mm, it is encased in a PPO housing that provides an IP40 degree of protection. Designed for a 3-phase (3AC) input network with a rated voltage of 200-240Vac, it consumes 8 VA of power. The operating mode is normally energized, and it includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) for digital outputs and 1 x analog input for L1-L3 voltage measurement. Its protection functions include phase sequence and phase failure.

Pilz

Quick Quote

PILZ-760100

Pilz PILZ-760100 is a protection unit designed for true power monitoring and measurement, with limit values that can be adjusted via a display and stored on a chip card. It supports DIN rail mounting and operates within an ambient air temperature range of -10 to +55°C. The unit has a net height of 100 mm and accommodates a rated current of 1A-12A for measuring, with safety output contacts ratings of 0.1A-5A at 24Vdc (DC-1; 120W), 0.1A-5A at 240Vac (AC-1; 1200VA), 2A at 24Vdc (DC-13), and 5A at 230Vac (AC-15). Connection is facilitated through plug-in/detachable spring terminal connections. The supply voltage ranges from 19.2-264Vac, covering 24Vac, 110Vac, 120Vac, 220Vac, and 240Vac nominal values, and from 19.2-264Vdc, covering 24Vdc, 110Vdc, 120Vdc, 220Vdc, and 250Vdc nominal values. It falls under the PMD s10 sub-range, with dimensions of W45mm x D120mm, and offers an IP40 degree of protection. The housing is made of PC material, and it is suitable for both single-phase (1AC) and 3-phase (3AC) input networks, with a rated voltage of 100-550Vac/dc for measuring voltage. The net width is 45 mm, and it consumes 3 W of power. Operating modes include fault latching/non-latching, automatic/manual reset, and normally energized/de-energized modes. It can be stored in temperatures ranging from -25 to +85°C. The unit features 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts; 0.1-5A 24Vdc 120W DC-1 or 240Vac 1200VA AC-1 resistive load), 1 x analog input for single-phase or 3-phase voltage measurement, and protection functions against overpower, overcurrent, and undercurrent. It also includes a link terminal and a measuring circuit for digital inputs, and 1 x analog output for voltage and current measurement.

Pilz

Quick Quote

PILZ-890150

Pilz PILZ-890150 is a protection unit designed for true power monitoring with a relay that supports 9 different measuring ranges. It features adjustable switching for underload and overload thresholds, along with customizable monitoring reaction time and start-up suppression time. This unit is suitable for DIN rail mounting and operates within an ambient air temperature range of 0 to +55°C. It has a net height of 87 mm and is rated for an 18A measuring current. The safety output contacts ratings vary from 0.1A to 5A at 24Vdc (DC-1; 120W) and 240Vac (AC-1; 1200VA), to 0.1A-1.5A at 24Vdc (DC-13) and 0.1A-1.8A at 230Vac (AC-15). Connection is established via fixed screw terminal connections. The supply voltage can range from 27.5-264.5Vac for AC and 93.5-287.5Vdc for DC, covering nominal voltages of 110Vac/120Vac/220Vac/230Vac and 110Vdc/120Vdc/220Vdc/250Vdc respectively. The S1WP sub-range model has dimensions of W22.5mm, with a degree of protection rated at IP40. It can handle a frequency measuring range of 0-1kHz and is constructed with a PPO housing. This unit is designed for both single-phase (1AC) and 3-phase (3AC) input networks, with a rated voltage for AC measuring voltage up to 415Vac/dc. The net width and depth are 22.5 mm and 121 mm, respectively, with a power consumption of 5 VA. It is capable of storage in ambient air temperatures ranging from -40 to +85°C. The digital outputs include 1 x auxiliary output (SPDT-NO/NC contacts) suitable for resistive loads, and it features 1 x analog input for current measurement and 1 x analog input for voltage measurement. The protection functions include underpower and overpower monitoring, complemented by 1 x analog output for voltage and current monitoring.

Pilz

Quick Quote

PILZ-890120

Pilz PILZ-890120 is a protection unit designed for true power monitoring with a relay that supports 9 different measuring ranges. It features adjustable switching for underload and overload thresholds, along with customizable monitoring reaction time and start-up suppression time. This unit is suitable for DIN rail mounting and operates within an ambient air temperature range of 0 to +55°C. It has a net height of 87 mm and is rated for an 18A measuring current. The safety output contacts ratings vary from 0.1A to 5A at 24Vdc (DC-1; 120W) and 240Vac (AC-1; 1200VA), with lower ratings for DC-13 and AC-15 applications. Connection is established via fixed screw terminal connections. The supply voltage can range from 27.5-264.5Vac for AC and 93.5-287.5Vdc for DC, covering standard nominal voltages. The S1WP sub-range model has dimensions of W22.5mm, a degree of protection of IP40, and operates within a frequency of 0-1kHz for its measuring range. Constructed with a PPO housing, it is designed for both single-phase (1AC) and 3-phase (3AC) input networks, with a rated voltage of 0-120Vac/dc for measuring voltage. The unit's net width and depth are 22.5 mm and 121 mm, respectively, and it has a power consumption of 5 VA. It can be stored in temperatures ranging from -40 to +85°C. The digital outputs include 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc 120W DC-1 or 240Vac 1200VA AC-1 resistive load), and it features 1 x analog input for current measurement and 1 x analog input for voltage measurement. Protection functions include underpower and overpower monitoring, complemented by 1 x analog output for voltage and current monitoring.

Pilz

Quick Quote

PILZ-890050

Pilz PILZ-890050 is a protection unit designed for true power monitoring with a relay function. It features nine different measuring ranges, adjustable switching thresholds for underload and overload conditions, and customizable monitoring reaction and start-up suppression times. This unit is suitable for DIN rail mounting and operates within an ambient air temperature range of 0 to +55°C. It has a net height of 87 mm and supports a rated current of 9A for measuring, with safety output contacts ratings ranging from 0.1A to 5A at 24Vdc (DC-1; 120W) and 240Vac (AC-1; 1200VA), and lower ratings for DC-13 and AC-15 applications. The connection type is fixed screw terminals, and it accepts a supply voltage of 27.5-264.5Vac for AC and 93.5-287.5Vdc for DC, covering a wide range of nominal voltages. The S1WP sub-range unit has dimensions of W22.5mm, a degree of protection of IP40, and operates within a frequency range of 0-1kHz. Constructed with a PPO housing, it is designed for both single-phase and 3-phase input networks, with a rated voltage measuring capacity of 0-415Vac/dc. The net width is 22.5 mm, and it consumes 5 VA of power. It has a net depth of 121 mm and can be stored in temperatures ranging from -40 to +85°C. The unit includes one auxiliary output (SPDT-NO/NC contacts) for resistive loads and two analog inputs for current and voltage measurement, alongside one analog output for voltage and current signaling. It is equipped with underpower and overpower protection functions.

Pilz

Quick Quote

PILZ-839770

Pilz PILZ-839770 is a protection unit designed for thermistor monitoring relay applications, featuring DIN rail mounting for easy installation. It operates within an ambient air temperature range of -10 to +55°C and has a net height of 87 mm. The unit offers fixed screw terminal connections and supports a supply voltage range of 20.4-26.4Vac (24Vac nominal) and 20.4-26.4Vdc (24Vdc nominal), belonging to the S1MN sub-range. With dimensions of W22.5mm and a degree of protection rated at IP40, it is housed in a PPO material casing. The PILZ-839770 has a net width of 22.5 mm, a depth of 121 mm, and consumes 2 W of power. It features an operating mode that allows for automatic reset or manual reset in a normally energized mode. The unit is designed to withstand ambient air temperatures for storage between -40 and +85°C. It includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) for digital outputs, 2 x analog inputs (T1-T2 measuring circuits) for monitoring, and offers protection functions against overheating with its thermistor. Additionally, it has 2 x reset circuit inputs (X2-X1) for digital inputs and boasts a mechanical durability of 10 million operations at no load.

Pilz

Quick Quote