PILZ-890120 Pilz Voltage Relays

PILZ-890120 on Powermatic Associates
Pilz

Part#:PILZ-890120

Manufacturer:Pilz

Category:Voltage Relays

Product Lifecycle:Active

Get a quick Quote!

Pilz PILZ-890120 is a protection unit designed for true power monitoring with a relay that supports 9 different measuring ranges. It features adjustable switching for underload and overload thresholds, along with customizable monitoring reaction time and start-up suppression time. This unit is suitable for DIN rail mounting and operates within an ambient air temperature range of 0 to +55°C. It has a net height of 87 mm and is rated for an 18A measuring current. The safety output contacts ratings vary from 0.1A to 5A at 24Vdc (DC-1; 120W) and 240Vac (AC-1; 1200VA), with lower ratings for DC-13 and AC-15 applications. Connection is established via fixed screw terminal connections. The supply voltage can range from 27.5-264.5Vac for AC and 93.5-287.5Vdc for DC, covering standard nominal voltages. The S1WP sub-range model has dimensions of W22.5mm, a degree of protection of IP40, and operates within a frequency of 0-1kHz for its measuring range. Constructed with a PPO housing, it is designed for both single-phase (1AC) and 3-phase (3AC) input networks, with a rated voltage of 0-120Vac/dc for measuring voltage. The unit's net width and depth are 22.5 mm and 121 mm, respectively, and it has a power consumption of 5 VA. It can be stored in temperatures ranging from -40 to +85°C. The digital outputs include 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc 120W DC-1 or 240Vac 1200VA AC-1 resistive load), and it features 1 x analog input for current measurement and 1 x analog input for voltage measurement. Protection functions include underpower and overpower monitoring, complemented by 1 x analog output for voltage and current monitoring.

About the manufacturer: Pilz is one of the manufacturers that offers Voltage Relays that you can order at Powermatic Associates site. We are at the forefront of driving the evolution of industrial automation. Our company ethos is built on dedication and principles, placing a high priority on safety. Over the years, we have been devoted to creating cutting-edge products and solutions tailored to our customers' requirements.

Check out the PILZ-890120 Pilz price in the box on the right side or send a quick quote.

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


PILZ-890120 Description

Pilz PILZ-890120 is a protection unit designed for true power monitoring with a relay that supports 9 different measuring ranges. It features adjustable switching for underload and overload thresholds, along with customizable monitoring reaction time and start-up suppression time. This unit is suitable for DIN rail mounting and operates within an ambient air temperature range of 0 to +55°C. It has a net height of 87 mm and is rated for an 18A measuring current. The safety output contacts ratings vary from 0.1A to 5A at 24Vdc (DC-1; 120W) and 240Vac (AC-1; 1200VA), with lower ratings for DC-13 and AC-15 applications. Connection is established via fixed screw terminal connections. The supply voltage can range from 27.5-264.5Vac for AC and 93.5-287.5Vdc for DC, covering standard nominal voltages. The S1WP sub-range model has dimensions of W22.5mm, a degree of protection of IP40, and operates within a frequency of 0-1kHz for its measuring range. Constructed with a PPO housing, it is designed for both single-phase (1AC) and 3-phase (3AC) input networks, with a rated voltage of 0-120Vac/dc for measuring voltage. The unit's net width and depth are 22.5 mm and 121 mm, respectively, and it has a power consumption of 5 VA. It can be stored in temperatures ranging from -40 to +85°C. The digital outputs include 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc 120W DC-1 or 240Vac 1200VA AC-1 resistive load), and it features 1 x analog input for current measurement and 1 x analog input for voltage measurement. Protection functions include underpower and overpower monitoring, complemented by 1 x analog output for voltage and current monitoring.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts

UBC10.241 on Powermatic Associates

UBC10.241

PULS UBC10.241 is an Uninterruptible Power Supply (UPS) control module within the U-series, featuring a built-in battery with a 50% power reserve and a green status LED. This module is housed in aluminium and utilizes spring-clamp connections for installation. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can reach up to 15A in buffer mode for less than 5 seconds at full output voltage. It supports DIN rail mounting and can operate in ambient air temperatures ranging from 0 to +40°C. The current consumption is 1.1A at a 24Vdc input, and it is designed for DC networks. Visual position indicators include Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. It is advised not to use the DC-UPS in parallel to increase output power, but paralleling two units for 1+1 redundancy is possible for higher system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. The efficiency is rated at 0.978 with a 24Vdc input, and the rated power is 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W with a 24Vdc input at 0A output current and 5.5W at 10A output current. Ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. The electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output.

Puls

1