All categories
Voltage Relays
All categories
Voltage Relays
Pilz PILZ-890071 is a protection unit designed for true power monitoring with a relay function. It features nine different measuring ranges, allowing for adjustable switching underload and overload thresholds. The unit also offers adjustable monitoring reaction time and start-up suppression time for tailored operation. Designed for DIN rail mounting, it operates within an ambient air temperature range of 0 to +55°C and has a net height of 87 mm. The rated current is 18A for measuring, with safety output contacts ratings ranging from 0.1A to 5A at 24Vdc (DC-1; 120W) and 0.1A to 1.5A at 24Vdc (DC-13). Connection is made via fixed screw terminal connections. As part of the S1WP sub-range, it measures 22.5mm in width, offers an IP40 degree of protection, and requires a supply voltage of 20.4-30Vdc (24Vdc nominal). The frequency range for measurement extends up to 1kHz. Constructed with a PPO housing, it supports both single-phase (1AC) and three-phase (3AC) input types, with a measuring voltage range of 0-120Vac/dc. The unit's width is 22.5 mm, depth is 121 mm, and it consumes 2W of power. It can be stored in temperatures ranging from -40 to +85°C. The digital outputs include 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc DC-1 120W resistive load), and the analog inputs comprise 1 x analog input for current measurement (K1-UL1) and 1 x analog input for voltage measurement (L1-L3). Protection functions include underpower and overpower monitoring, with 1 x analog output for voltage (U) and current (I) monitoring.
Quick Quote
Pilz PILZ-840410 is a protection unit designed for thermistor monitoring relay applications, featuring DIN rail mounting for ease of installation. It operates within an ambient air temperature range of -10 to +55 °C and has a net height of 87 mm. The unit is equipped with fixed screw terminal connections and requires a supply voltage of 195.5-253Vac (230Vac nominal) under the S1MN sub-range. With dimensions of W22.5mm and a degree of protection rated at IP40, the PILZ-840410 is housed in a PPO material ensuring durability. It has a net width of 22.5 mm and a depth of 121 mm, with a power consumption of 3.5 VA. This model supports both automatic and manual reset operating modes in a normally energized configuration. It is designed to withstand ambient air temperatures for storage between -40 and +85 °C. The unit features 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) for digital outputs, 2 x analog inputs for T1-T2 measuring circuits, and 2 x reset circuit inputs for digital inputs. It offers protection functions specifically for overheating (Thermistor) and boasts a mechanical durability of 10 million operations at no load.
Quick Quote
Pilz PILZ-840405 is a protection unit designed for thermistor monitoring relay applications, featuring DIN rail mounting for easy installation. It operates within an ambient air temperature range of -10 to +55 °C and has a net height of 87 mm. This unit offers fixed screw terminal connections and requires a supply voltage of 93.5-121Vac (110Vac nominal) within the S1MN sub-range. With dimensions of W22.5mm x D121mm and a net width of 22.5 mm, it is encased in a PPO housing that provides an IP40 degree of protection. The PILZ-840405 consumes 3.5 VA of power and supports both automatic and manual reset operating modes in a normally energized configuration. It is designed for storage in environments with ambient air temperatures ranging from -40 to +85 °C. The unit includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) and 2 x analog inputs (T1-T2 measuring circuits) for comprehensive monitoring. Its protection functions are specifically aimed at overheating protection through thermistor monitoring. Additionally, it features 2 x reset circuit inputs (X2-X1) and boasts a mechanical durability of 10 million operations at no load.
Quick Quote
Pilz PILZ-761100 is an insulation monitor designed for DIN rail mounting, featuring insulation and earth fault monitoring with limit values that can be set via display and stored on a chip card. It operates within an ambient air temperature range of -10 to +55°C and has a net height of 98 mm. The connection type is plug-in/detachable spring terminals, supporting a supply voltage range of 20.4-264Vac (24Vac / 120Vac / 240Vac nominal) and 20.4-264Vdc (24Vdc / 110Vdc / 120Vdc / 220Vdc / 250Vdc nominal) within the PMD s20 sub-range. The device measures 45mm in width, offers an IP40 degree of protection, and is housed in a PC material. It is rated for 0-400Vac, with a net width of 45 mm and a depth of 120 mm. Power consumption is 2.5 W. Operating modes include fault latching/non-latching, automatic/manual reset, and normally energized/de-energized modes. It can be stored in temperatures ranging from -40 to +85°C. The monitor includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts), 1 x analog input for 2-phase or 3-phase voltage measurement, and features galvanic isolation protection. Digital inputs comprise 1 x reset input, 1 x test input, and 1 x feedback earth.
Quick Quote
Pilz PILZ-890020 is a protection unit designed for true power monitoring with a relay function. It features nine different measuring ranges, allowing for precise control over underload and overload thresholds, which are adjustable. The unit also offers customizable monitoring reaction times and start-up suppression times to suit various operational requirements. Designed for DIN rail mounting, it operates within an ambient air temperature range of 0 to +55°C and has a net height of 87 mm. The rated current for measuring is 9A, with safety output contacts ratings ranging from 0.1A to 5A at 24Vdc (DC-1; 120W) and 0.1A to 1.5A at 24Vdc (DC-13). Connection is facilitated through fixed screw terminal connections. The S1WP sub-range part has dimensions of W22.5mm x D121 mm, with a degree of protection rated at IP40. It requires a supply voltage of 20.4-30Vdc (24Vdc nominal) and can measure frequency ranges from 0 to 1kHz. The housing is made of PPO material, suitable for both single-phase (1AC) and three-phase (3AC) input types, with a rated voltage for AC measuring voltage from 0 to 550Vac/dc. The net width is 22.5 mm, and it consumes 2W of power. Suitable for storage in ambient air temperatures ranging from -40 to +85°C, it includes 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc DC-1 120W resistive load) and 1 x analog input for both current (K1-UL1) and voltage (L1-L3) measurement. The protection functions include underpower and overpower monitoring, complemented by 1 x analog output for voltage (U) and current (I) monitoring.
Quick Quote
Pilz PILZ-890010 is a protection unit designed for true power monitoring with a relay function. It features nine different measuring ranges, allowing for precise monitoring across a variety of applications. The unit offers adjustable switching thresholds for both underload and overload conditions, as well as customizable monitoring reaction times and start-up suppression times to suit specific operational requirements. Designed for DIN rail mounting, this protection unit operates within an ambient air temperature range of 0 to +55°C and has a net height of 87 mm. It supports a rated current of 9A for measuring, with safety output contacts ratings ranging from 0.1A to 5A at 24Vdc (DC-1; 120W) and 0.1A to 1.5A at 24Vdc (DC-13). Connection is facilitated through fixed screw terminal connections, and it falls under the S1WP sub-range. The dimensions include a width of 22.5mm and a degree of protection rated at IP40. The supply voltage requirement is 20.4-30Vdc (24Vdc nominal), and it can measure frequency ranges from 0 to 1kHz. Constructed with a PPO housing, it is suitable for both single-phase (1AC) and three-phase (3AC) input types, with a rated voltage for AC measuring voltage from 0 to 415Vac/dc. The net width is 22.5 mm, and it consumes 2W of power. The depth of the unit is 121 mm, and it can be stored in temperatures ranging from -40 to +85°C. It includes 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc DC-1 120W resistive load) and 1 x analog input for both current (K1-UL1) and voltage (L1-L3) measurement, alongside protection functions for underpower and overpower conditions. Additionally, it features 1 x analog output for voltage (U) and current (I) monitoring.
Quick Quote
Pilz PILZ-841000 is a software component designed specifically for use with PAScal, featuring a basic license. This product facilitates the programming and configuration tasks associated with Pilz safety controllers, streamlining the integration and setup process for automation systems.
Quick Quote
Pilz PILZ-840740 is a protection unit designed for thermistor monitoring relay thermistor monitoring. It features DIN rail mounting and operates within an ambient air temperature range of -10 to +55 °C. The unit has a net height of 87 mm and is designed with an automatic reset function. It utilizes fixed screw terminal connections for secure installation and requires a supply voltage of 195.5-253Vac (230Vac nominal) within the S1MS sub-range. The dimensions include a width of 22.5 mm and a depth of 121 mm, offering a compact form factor with an IP40 degree of protection. The housing is made from PPO material, ensuring durability. Power consumption is rated at 3.5 VA. The operating mode is set to automatic reset, normally energized mode. For connectivity, it includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) and 2 x analog inputs (T1-T2 measuring circuits) for comprehensive monitoring. The protection functions are specifically designed for overheating protection, utilizing thermistors to safeguard against temperature-related issues.
Quick Quote
Pilz PILZ-840400 is a protection unit designed for thermistor monitoring relay applications, featuring DIN rail mounting for ease of installation. It operates within an ambient air temperature range of -10 to +55°C and has a net height of 87 mm with fixed screw terminal connections. This unit is supplied with a voltage range of 40.8-52.8Vac (48Vac nominal) under the sub-range name S1MN. The dimensions include a width of 22.5mm and a depth of 121 mm, encased in a PPO housing that provides an IP40 degree of protection. It consumes 3.5 VA of power and offers both automatic and manual reset options in normally energized mode. The PILZ-840400 can withstand ambient air temperatures for storage between -40 and +85°C. It includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) and 2 x analog inputs (T1-T2 measuring circuits) for comprehensive monitoring. The unit is equipped with digital inputs for 2 x reset circuit inputs (X2-X1) and offers overheating protection through its thermistor. With a mechanical durability of 10 million operations at no load, this unit is designed for longevity in its protective functions.
Quick Quote
Pilz PILZ-837300 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 24Vdc (DC-1; 120W) and 1.5A at 24Vdc (DC-13). Connection is facilitated through fixed screw terminal connections. As part of the S3UM sub-range, this unit measures 22.5mm in width, offers an IP40 degree of protection, and requires a supply voltage of 20.4-26.4Vdc (24Vdc nominal). It operates across a frequency measuring range of 40-400Hz and is housed in PPO material. Designed for a 3-phase (3AC) input network, it measures rated voltages of 208/400/480Vac and has a net width of 22.5 mm. Power consumption is rated at 1.5 W, with a net depth of 122 mm. Operating modes include fault latching/non-latching and normally energized/de-energized modes. Storage temperature tolerance ranges from -40 to +85°C. It features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc DC-1 resistive load; 0.5-10s time-delay selectable), 1 x analog input for L1-L3 voltage measurement, and protection functions against undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. Additionally, it includes 1 x automatic reset and 1 x switching commutation digital inputs.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
PILZ-890071 Pilz PILZ-890071 is a protection unit designed for true power monitoring with a relay function. It features nine different measuring ranges, allowing for adjustable switching underload and overload thresholds. The unit also offers adjustable monitoring reaction time and start-up suppression time for tailored operation. Designed for DIN rail mounting, it operates within an ambient air temperature range of 0 to +55°C and has a net height of 87 mm. The rated current is 18A for measuring, with safety output contacts ratings ranging from 0.1A to 5A at 24Vdc (DC-1; 120W) and 0.1A to 1.5A at 24Vdc (DC-13). Connection is made via fixed screw terminal connections. As part of the S1WP sub-range, it measures 22.5mm in width, offers an IP40 degree of protection, and requires a supply voltage of 20.4-30Vdc (24Vdc nominal). The frequency range for measurement extends up to 1kHz. Constructed with a PPO housing, it supports both single-phase (1AC) and three-phase (3AC) input types, with a measuring voltage range of 0-120Vac/dc. The unit's width is 22.5 mm, depth is 121 mm, and it consumes 2W of power. It can be stored in temperatures ranging from -40 to +85°C. The digital outputs include 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc DC-1 120W resistive load), and the analog inputs comprise 1 x analog input for current measurement (K1-UL1) and 1 x analog input for voltage measurement (L1-L3). Protection functions include underpower and overpower monitoring, with 1 x analog output for voltage (U) and current (I) monitoring. | Pilz | Quick Quote | |||
PILZ-840410 Pilz PILZ-840410 is a protection unit designed for thermistor monitoring relay applications, featuring DIN rail mounting for ease of installation. It operates within an ambient air temperature range of -10 to +55 °C and has a net height of 87 mm. The unit is equipped with fixed screw terminal connections and requires a supply voltage of 195.5-253Vac (230Vac nominal) under the S1MN sub-range. With dimensions of W22.5mm and a degree of protection rated at IP40, the PILZ-840410 is housed in a PPO material ensuring durability. It has a net width of 22.5 mm and a depth of 121 mm, with a power consumption of 3.5 VA. This model supports both automatic and manual reset operating modes in a normally energized configuration. It is designed to withstand ambient air temperatures for storage between -40 and +85 °C. The unit features 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) for digital outputs, 2 x analog inputs for T1-T2 measuring circuits, and 2 x reset circuit inputs for digital inputs. It offers protection functions specifically for overheating (Thermistor) and boasts a mechanical durability of 10 million operations at no load. | Pilz | Quick Quote | |||
PILZ-840405 Pilz PILZ-840405 is a protection unit designed for thermistor monitoring relay applications, featuring DIN rail mounting for easy installation. It operates within an ambient air temperature range of -10 to +55 °C and has a net height of 87 mm. This unit offers fixed screw terminal connections and requires a supply voltage of 93.5-121Vac (110Vac nominal) within the S1MN sub-range. With dimensions of W22.5mm x D121mm and a net width of 22.5 mm, it is encased in a PPO housing that provides an IP40 degree of protection. The PILZ-840405 consumes 3.5 VA of power and supports both automatic and manual reset operating modes in a normally energized configuration. It is designed for storage in environments with ambient air temperatures ranging from -40 to +85 °C. The unit includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) and 2 x analog inputs (T1-T2 measuring circuits) for comprehensive monitoring. Its protection functions are specifically aimed at overheating protection through thermistor monitoring. Additionally, it features 2 x reset circuit inputs (X2-X1) and boasts a mechanical durability of 10 million operations at no load. | Pilz | Quick Quote | |||
PILZ-761100 Pilz PILZ-761100 is an insulation monitor designed for DIN rail mounting, featuring insulation and earth fault monitoring with limit values that can be set via display and stored on a chip card. It operates within an ambient air temperature range of -10 to +55°C and has a net height of 98 mm. The connection type is plug-in/detachable spring terminals, supporting a supply voltage range of 20.4-264Vac (24Vac / 120Vac / 240Vac nominal) and 20.4-264Vdc (24Vdc / 110Vdc / 120Vdc / 220Vdc / 250Vdc nominal) within the PMD s20 sub-range. The device measures 45mm in width, offers an IP40 degree of protection, and is housed in a PC material. It is rated for 0-400Vac, with a net width of 45 mm and a depth of 120 mm. Power consumption is 2.5 W. Operating modes include fault latching/non-latching, automatic/manual reset, and normally energized/de-energized modes. It can be stored in temperatures ranging from -40 to +85°C. The monitor includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts), 1 x analog input for 2-phase or 3-phase voltage measurement, and features galvanic isolation protection. Digital inputs comprise 1 x reset input, 1 x test input, and 1 x feedback earth. | Pilz | Quick Quote | |||
PILZ-890020 Pilz PILZ-890020 is a protection unit designed for true power monitoring with a relay function. It features nine different measuring ranges, allowing for precise control over underload and overload thresholds, which are adjustable. The unit also offers customizable monitoring reaction times and start-up suppression times to suit various operational requirements. Designed for DIN rail mounting, it operates within an ambient air temperature range of 0 to +55°C and has a net height of 87 mm. The rated current for measuring is 9A, with safety output contacts ratings ranging from 0.1A to 5A at 24Vdc (DC-1; 120W) and 0.1A to 1.5A at 24Vdc (DC-13). Connection is facilitated through fixed screw terminal connections. The S1WP sub-range part has dimensions of W22.5mm x D121 mm, with a degree of protection rated at IP40. It requires a supply voltage of 20.4-30Vdc (24Vdc nominal) and can measure frequency ranges from 0 to 1kHz. The housing is made of PPO material, suitable for both single-phase (1AC) and three-phase (3AC) input types, with a rated voltage for AC measuring voltage from 0 to 550Vac/dc. The net width is 22.5 mm, and it consumes 2W of power. Suitable for storage in ambient air temperatures ranging from -40 to +85°C, it includes 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc DC-1 120W resistive load) and 1 x analog input for both current (K1-UL1) and voltage (L1-L3) measurement. The protection functions include underpower and overpower monitoring, complemented by 1 x analog output for voltage (U) and current (I) monitoring. | Pilz | Quick Quote | |||
PILZ-890010 Pilz PILZ-890010 is a protection unit designed for true power monitoring with a relay function. It features nine different measuring ranges, allowing for precise monitoring across a variety of applications. The unit offers adjustable switching thresholds for both underload and overload conditions, as well as customizable monitoring reaction times and start-up suppression times to suit specific operational requirements. Designed for DIN rail mounting, this protection unit operates within an ambient air temperature range of 0 to +55°C and has a net height of 87 mm. It supports a rated current of 9A for measuring, with safety output contacts ratings ranging from 0.1A to 5A at 24Vdc (DC-1; 120W) and 0.1A to 1.5A at 24Vdc (DC-13). Connection is facilitated through fixed screw terminal connections, and it falls under the S1WP sub-range. The dimensions include a width of 22.5mm and a degree of protection rated at IP40. The supply voltage requirement is 20.4-30Vdc (24Vdc nominal), and it can measure frequency ranges from 0 to 1kHz. Constructed with a PPO housing, it is suitable for both single-phase (1AC) and three-phase (3AC) input types, with a rated voltage for AC measuring voltage from 0 to 415Vac/dc. The net width is 22.5 mm, and it consumes 2W of power. The depth of the unit is 121 mm, and it can be stored in temperatures ranging from -40 to +85°C. It includes 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc DC-1 120W resistive load) and 1 x analog input for both current (K1-UL1) and voltage (L1-L3) measurement, alongside protection functions for underpower and overpower conditions. Additionally, it features 1 x analog output for voltage (U) and current (I) monitoring. | Pilz | Quick Quote | |||
PILZ-841000 Pilz PILZ-841000 is a software component designed specifically for use with PAScal, featuring a basic license. This product facilitates the programming and configuration tasks associated with Pilz safety controllers, streamlining the integration and setup process for automation systems. | Pilz | Quick Quote | |||
PILZ-840740 Pilz PILZ-840740 is a protection unit designed for thermistor monitoring relay thermistor monitoring. It features DIN rail mounting and operates within an ambient air temperature range of -10 to +55 °C. The unit has a net height of 87 mm and is designed with an automatic reset function. It utilizes fixed screw terminal connections for secure installation and requires a supply voltage of 195.5-253Vac (230Vac nominal) within the S1MS sub-range. The dimensions include a width of 22.5 mm and a depth of 121 mm, offering a compact form factor with an IP40 degree of protection. The housing is made from PPO material, ensuring durability. Power consumption is rated at 3.5 VA. The operating mode is set to automatic reset, normally energized mode. For connectivity, it includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) and 2 x analog inputs (T1-T2 measuring circuits) for comprehensive monitoring. The protection functions are specifically designed for overheating protection, utilizing thermistors to safeguard against temperature-related issues. | Pilz | Quick Quote | |||
PILZ-840400 Pilz PILZ-840400 is a protection unit designed for thermistor monitoring relay applications, featuring DIN rail mounting for ease of installation. It operates within an ambient air temperature range of -10 to +55°C and has a net height of 87 mm with fixed screw terminal connections. This unit is supplied with a voltage range of 40.8-52.8Vac (48Vac nominal) under the sub-range name S1MN. The dimensions include a width of 22.5mm and a depth of 121 mm, encased in a PPO housing that provides an IP40 degree of protection. It consumes 3.5 VA of power and offers both automatic and manual reset options in normally energized mode. The PILZ-840400 can withstand ambient air temperatures for storage between -40 and +85°C. It includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) and 2 x analog inputs (T1-T2 measuring circuits) for comprehensive monitoring. The unit is equipped with digital inputs for 2 x reset circuit inputs (X2-X1) and offers overheating protection through its thermistor. With a mechanical durability of 10 million operations at no load, this unit is designed for longevity in its protective functions. | Pilz | Quick Quote | |||
PILZ-837300 Pilz PILZ-837300 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 24Vdc (DC-1; 120W) and 1.5A at 24Vdc (DC-13). Connection is facilitated through fixed screw terminal connections. As part of the S3UM sub-range, this unit measures 22.5mm in width, offers an IP40 degree of protection, and requires a supply voltage of 20.4-26.4Vdc (24Vdc nominal). It operates across a frequency measuring range of 40-400Hz and is housed in PPO material. Designed for a 3-phase (3AC) input network, it measures rated voltages of 208/400/480Vac and has a net width of 22.5 mm. Power consumption is rated at 1.5 W, with a net depth of 122 mm. Operating modes include fault latching/non-latching and normally energized/de-energized modes. Storage temperature tolerance ranges from -40 to +85°C. It features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc DC-1 resistive load; 0.5-10s time-delay selectable), 1 x analog input for L1-L3 voltage measurement, and protection functions against undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. Additionally, it includes 1 x automatic reset and 1 x switching commutation digital inputs. | Pilz | Quick Quote |