Pilz PILZ-890050 is a protection unit designed for true power monitoring with a relay function. It features nine different measuring ranges, adjustable switching thresholds for underload and overload conditions, and customizable monitoring reaction and start-up suppression times. This unit is suitable for DIN rail mounting and operates within an ambient air temperature range of 0 to +55°C. It has a net height of 87 mm and supports a rated current of 9A for measuring, with safety output contacts ratings ranging from 0.1A to 5A at 24Vdc (DC-1; 120W) and 240Vac (AC-1; 1200VA), and lower ratings for DC-13 and AC-15 applications. The connection type is fixed screw terminals, and it accepts a supply voltage of 27.5-264.5Vac for AC and 93.5-287.5Vdc for DC, covering a wide range of nominal voltages. The S1WP sub-range unit has dimensions of W22.5mm, a degree of protection of IP40, and operates within a frequency range of 0-1kHz. Constructed with a PPO housing, it is designed for both single-phase and 3-phase input networks, with a rated voltage measuring capacity of 0-415Vac/dc. The net width is 22.5 mm, and it consumes 5 VA of power. It has a net depth of 121 mm and can be stored in temperatures ranging from -40 to +85°C. The unit includes one auxiliary output (SPDT-NO/NC contacts) for resistive loads and two analog inputs for current and voltage measurement, alongside one analog output for voltage and current signaling. It is equipped with underpower and overpower protection functions.
Quick Quote
Pilz PILZ-837360 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15). Connection is facilitated through fixed screw terminal connections. The supply voltage requirement is 195.5-253Vac (230Vac nominal) within the S3UM sub-range. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. It operates across a frequency range of 40-400Hz and is housed in a PPO material. The type of network supported is a 3-phase (3AC) input with a rated voltage for measuring at 400/440Vac. The net width is 22.5 mm, and the power consumption is rated at 1.5 W, with a net depth of 122 mm. Operating modes include fault latching or non-latching and normally energized or de-energized modes. It can be stored in temperatures ranging from -40 to +85°C. The unit features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load; 0.5-10s time-delay selectable) and 1 x analog input for L1-L3 voltage measurement. Protection functions cover undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. Digital inputs include 1 x automatic reset and 1 x switching commutation.
Quick Quote
Pilz PILZ-839770 is a protection unit designed for thermistor monitoring relay applications, featuring DIN rail mounting for easy installation. It operates within an ambient air temperature range of -10 to +55°C and has a net height of 87 mm. The unit offers fixed screw terminal connections and supports a supply voltage range of 20.4-26.4Vac (24Vac nominal) and 20.4-26.4Vdc (24Vdc nominal), belonging to the S1MN sub-range. With dimensions of W22.5mm and a degree of protection rated at IP40, it is housed in a PPO material casing. The PILZ-839770 has a net width of 22.5 mm, a depth of 121 mm, and consumes 2 W of power. It features an operating mode that allows for automatic reset or manual reset in a normally energized mode. The unit is designed to withstand ambient air temperatures for storage between -40 and +85°C. It includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) for digital outputs, 2 x analog inputs (T1-T2 measuring circuits) for monitoring, and offers protection functions against overheating with its thermistor. Additionally, it has 2 x reset circuit inputs (X2-X1) for digital inputs and boasts a mechanical durability of 10 million operations at no load.
Quick Quote
Pilz PILZ-837370 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15). Connection is facilitated through fixed screw terminal connections. The supply voltage requirement is 195.5-253Vac (230Vac nominal) within the S3UM sub-range, and the device dimensions are 22.5mm in width. It offers an IP40 degree of protection and operates across a frequency range of 40-400Hz. The housing is made of PPO material, and it is designed for a 3-phase (3AC) input network with a rated voltage (AC) of 415/460Vac for measuring voltage. The net width is 22.5 mm, and it has a power consumption of 1.5 W. The operating modes include fault latching/non-latching and normally energized/de-energized modes. The unit can be stored in temperatures ranging from -40 to +85°C. It features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load; 0.5-10s time-delay selectable for ON-delay energization), 1 x analog input for L1-L3 voltage measurement, and protection functions against undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. Additionally, it includes 1 x automatic reset and 1 x switching commutation digital inputs.
Quick Quote
Pilz PILZ-827260 is a protection unit designed as a single-phase voltage monitoring relay suitable for DIN rail mounting. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. The design ensures that measuring inputs are not polarity-sensitive. It features safety output contacts ratings of 0.1A-5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15), with fixed screw terminal connections. The supply voltage requirement is 195.5-264Vac (230Vac / 240Vac nom.) under the sub-range name S1UM. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. The frequency measuring range is 0.4-400Hz, housed in a PPO material. It is designed for a single-phase (1AC) input network, with a rated voltage (AC) for measuring voltage adjustable between 0.1-500Vac/dc. The net width is 22.5 mm, and it consumes 2 VA of power with a net depth of 121 mm. Operating modes include fault latching or fault non-latching, and normally energized mode or normally de-energized mode. It can be stored in temperatures ranging from -40 to +85°C. The unit has 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load) for digital outputs, and protection functions against overvoltage with a response time of 0.1-10 s. Digital inputs consist of 1 x de-energized mode input (Y1-Y2) and 1 x latching input (Y3).
Quick Quote
Pilz PILZ-828030 is a protection unit designed for current monitoring relay applications, featuring DIN rail mounting for easy installation. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. This unit supports a rated current from 0.01 to 15A for measuring current and utilizes fixed screw terminal connections. It is supplied with a voltage range of 110Vac to 127Vac (120Vac nominal) under the sub-range name S1IM. The dimensions include a width of 22.5mm and a degree of protection rated at IP40, with a frequency measuring range of 40-400Hz. Constructed with a PPO housing, it is designed for single-phase (1AC) input networks and has a net width of 22.5 mm. The power consumption is minimal at 2 VA, and the net depth is 121 mm. It offers versatile operating modes including fault latching/non-latching and normally energized/de-energized modes. The ambient air temperature for storage extends from -40 to +85°C. It features 1 x auxiliary output (SPDT-NO/NC contacts) for digital outputs, and protection functions against overcurrent. Digital inputs include 1 x latching/non-latching input, 1 x energized/de-energized mode input, and 1 x measuring range input for enhanced flexibility in application.
Quick Quote
Pilz PILZ-840775 is a protection unit designed for fault voltage monitoring relay applications. It features DIN rail mounting and operates within an ambient air temperature range of -10 to +55 °C. This unit offers fixed screw terminal connections and supports a wide supply voltage range of 19.2-264Vac, including nominal voltages of 24Vac, 110Vac, 120Vac, 220Vac, and 240Vac, as well as a DC supply voltage range of 19.2-264Vdc, with nominal voltages of 24Vdc, 110Vdc, 120Vdc, 220Vdc, and 250Vdc. The PFU6 sub-range model comes with an IP40 degree of protection and is capable of handling frequencies from 50 to 1000Hz. It has a rated voltage for AC and DC measuring voltage up to 690Vac/dc and consumes 2W of power. For storage, it can withstand ambient air temperatures from -40 to +85 °C. The unit includes 1 auxiliary output with SPDT-NO/NC contacts and 6 analog inputs for various measuring circuits. It also features overvoltage protection functions, along with 1 reset input and 1 test input for digital interfacing.
Quick Quote
Pilz PILZ-827110 is a protection unit designed as a single-phase voltage monitoring relay suitable for DIN rail mounting. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. The design ensures that measuring inputs are not polarity-sensitive. It features safety output contacts ratings of 0.1A-5A at 24Vdc (DC-1; 120W) and 1.5A at 24Vdc (DC-13). The connection type is fixed screw terminal connections. As part of the S1UM sub-range, it measures 22.5mm in width, offers an IP40 degree of protection, and requires a supply voltage of 20.4-26.4Vdc (24Vdc nominal). The frequency measuring range is 0.4-400Hz, and it is housed in PPO material. This unit is designed for single-phase (1AC) input networks with a rated voltage (AC) of 0.1-500Vac/dc (adjustable). It has a net width of 22.5 mm, consumes 1 W of power, and has a net depth of 121 mm. The operating modes include fault latching/non-latching and normally energized/de-energized modes. It can be stored in temperatures ranging from -40 to +85°C. The digital outputs consist of 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc DC-1 120W resistive load), and it features digital inputs of 1 x de-energized mode input (Y1-Y2) and 1 x latching input (Y3). The protection functions include overvoltage, with a response time of 0.1-10 s.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
PILZ-890050 Pilz PILZ-890050 is a protection unit designed for true power monitoring with a relay function. It features nine different measuring ranges, adjustable switching thresholds for underload and overload conditions, and customizable monitoring reaction and start-up suppression times. This unit is suitable for DIN rail mounting and operates within an ambient air temperature range of 0 to +55°C. It has a net height of 87 mm and supports a rated current of 9A for measuring, with safety output contacts ratings ranging from 0.1A to 5A at 24Vdc (DC-1; 120W) and 240Vac (AC-1; 1200VA), and lower ratings for DC-13 and AC-15 applications. The connection type is fixed screw terminals, and it accepts a supply voltage of 27.5-264.5Vac for AC and 93.5-287.5Vdc for DC, covering a wide range of nominal voltages. The S1WP sub-range unit has dimensions of W22.5mm, a degree of protection of IP40, and operates within a frequency range of 0-1kHz. Constructed with a PPO housing, it is designed for both single-phase and 3-phase input networks, with a rated voltage measuring capacity of 0-415Vac/dc. The net width is 22.5 mm, and it consumes 5 VA of power. It has a net depth of 121 mm and can be stored in temperatures ranging from -40 to +85°C. The unit includes one auxiliary output (SPDT-NO/NC contacts) for resistive loads and two analog inputs for current and voltage measurement, alongside one analog output for voltage and current signaling. It is equipped with underpower and overpower protection functions. | Pilz | Quick Quote | |||
PILZ-837360 Pilz PILZ-837360 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15). Connection is facilitated through fixed screw terminal connections. The supply voltage requirement is 195.5-253Vac (230Vac nominal) within the S3UM sub-range. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. It operates across a frequency range of 40-400Hz and is housed in a PPO material. The type of network supported is a 3-phase (3AC) input with a rated voltage for measuring at 400/440Vac. The net width is 22.5 mm, and the power consumption is rated at 1.5 W, with a net depth of 122 mm. Operating modes include fault latching or non-latching and normally energized or de-energized modes. It can be stored in temperatures ranging from -40 to +85°C. The unit features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load; 0.5-10s time-delay selectable) and 1 x analog input for L1-L3 voltage measurement. Protection functions cover undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. Digital inputs include 1 x automatic reset and 1 x switching commutation. | Pilz | Quick Quote | |||
PILZ-839770 Pilz PILZ-839770 is a protection unit designed for thermistor monitoring relay applications, featuring DIN rail mounting for easy installation. It operates within an ambient air temperature range of -10 to +55°C and has a net height of 87 mm. The unit offers fixed screw terminal connections and supports a supply voltage range of 20.4-26.4Vac (24Vac nominal) and 20.4-26.4Vdc (24Vdc nominal), belonging to the S1MN sub-range. With dimensions of W22.5mm and a degree of protection rated at IP40, it is housed in a PPO material casing. The PILZ-839770 has a net width of 22.5 mm, a depth of 121 mm, and consumes 2 W of power. It features an operating mode that allows for automatic reset or manual reset in a normally energized mode. The unit is designed to withstand ambient air temperatures for storage between -40 and +85°C. It includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) for digital outputs, 2 x analog inputs (T1-T2 measuring circuits) for monitoring, and offers protection functions against overheating with its thermistor. Additionally, it has 2 x reset circuit inputs (X2-X1) for digital inputs and boasts a mechanical durability of 10 million operations at no load. | Pilz | Quick Quote | |||
PILZ-837370 Pilz PILZ-837370 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15). Connection is facilitated through fixed screw terminal connections. The supply voltage requirement is 195.5-253Vac (230Vac nominal) within the S3UM sub-range, and the device dimensions are 22.5mm in width. It offers an IP40 degree of protection and operates across a frequency range of 40-400Hz. The housing is made of PPO material, and it is designed for a 3-phase (3AC) input network with a rated voltage (AC) of 415/460Vac for measuring voltage. The net width is 22.5 mm, and it has a power consumption of 1.5 W. The operating modes include fault latching/non-latching and normally energized/de-energized modes. The unit can be stored in temperatures ranging from -40 to +85°C. It features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load; 0.5-10s time-delay selectable for ON-delay energization), 1 x analog input for L1-L3 voltage measurement, and protection functions against undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. Additionally, it includes 1 x automatic reset and 1 x switching commutation digital inputs. | Pilz | Quick Quote | |||
PILZ-827260 Pilz PILZ-827260 is a protection unit designed as a single-phase voltage monitoring relay suitable for DIN rail mounting. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. The design ensures that measuring inputs are not polarity-sensitive. It features safety output contacts ratings of 0.1A-5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15), with fixed screw terminal connections. The supply voltage requirement is 195.5-264Vac (230Vac / 240Vac nom.) under the sub-range name S1UM. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. The frequency measuring range is 0.4-400Hz, housed in a PPO material. It is designed for a single-phase (1AC) input network, with a rated voltage (AC) for measuring voltage adjustable between 0.1-500Vac/dc. The net width is 22.5 mm, and it consumes 2 VA of power with a net depth of 121 mm. Operating modes include fault latching or fault non-latching, and normally energized mode or normally de-energized mode. It can be stored in temperatures ranging from -40 to +85°C. The unit has 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load) for digital outputs, and protection functions against overvoltage with a response time of 0.1-10 s. Digital inputs consist of 1 x de-energized mode input (Y1-Y2) and 1 x latching input (Y3). | Pilz | Quick Quote | |||
PILZ-890220 Pilz PILZ-890220 | Pilz | Quick Quote | |||
PILZ-828030 Pilz PILZ-828030 is a protection unit designed for current monitoring relay applications, featuring DIN rail mounting for easy installation. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. This unit supports a rated current from 0.01 to 15A for measuring current and utilizes fixed screw terminal connections. It is supplied with a voltage range of 110Vac to 127Vac (120Vac nominal) under the sub-range name S1IM. The dimensions include a width of 22.5mm and a degree of protection rated at IP40, with a frequency measuring range of 40-400Hz. Constructed with a PPO housing, it is designed for single-phase (1AC) input networks and has a net width of 22.5 mm. The power consumption is minimal at 2 VA, and the net depth is 121 mm. It offers versatile operating modes including fault latching/non-latching and normally energized/de-energized modes. The ambient air temperature for storage extends from -40 to +85°C. It features 1 x auxiliary output (SPDT-NO/NC contacts) for digital outputs, and protection functions against overcurrent. Digital inputs include 1 x latching/non-latching input, 1 x energized/de-energized mode input, and 1 x measuring range input for enhanced flexibility in application. | Pilz | Quick Quote | |||
PILZ-840775 Pilz PILZ-840775 is a protection unit designed for fault voltage monitoring relay applications. It features DIN rail mounting and operates within an ambient air temperature range of -10 to +55 °C. This unit offers fixed screw terminal connections and supports a wide supply voltage range of 19.2-264Vac, including nominal voltages of 24Vac, 110Vac, 120Vac, 220Vac, and 240Vac, as well as a DC supply voltage range of 19.2-264Vdc, with nominal voltages of 24Vdc, 110Vdc, 120Vdc, 220Vdc, and 250Vdc. The PFU6 sub-range model comes with an IP40 degree of protection and is capable of handling frequencies from 50 to 1000Hz. It has a rated voltage for AC and DC measuring voltage up to 690Vac/dc and consumes 2W of power. For storage, it can withstand ambient air temperatures from -40 to +85 °C. The unit includes 1 auxiliary output with SPDT-NO/NC contacts and 6 analog inputs for various measuring circuits. It also features overvoltage protection functions, along with 1 reset input and 1 test input for digital interfacing. | Pilz | Quick Quote | |||
PILZ-890200 Pilz PILZ-890200 | Pilz | Quick Quote | |||
PILZ-827110 Pilz PILZ-827110 is a protection unit designed as a single-phase voltage monitoring relay suitable for DIN rail mounting. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. The design ensures that measuring inputs are not polarity-sensitive. It features safety output contacts ratings of 0.1A-5A at 24Vdc (DC-1; 120W) and 1.5A at 24Vdc (DC-13). The connection type is fixed screw terminal connections. As part of the S1UM sub-range, it measures 22.5mm in width, offers an IP40 degree of protection, and requires a supply voltage of 20.4-26.4Vdc (24Vdc nominal). The frequency measuring range is 0.4-400Hz, and it is housed in PPO material. This unit is designed for single-phase (1AC) input networks with a rated voltage (AC) of 0.1-500Vac/dc (adjustable). It has a net width of 22.5 mm, consumes 1 W of power, and has a net depth of 121 mm. The operating modes include fault latching/non-latching and normally energized/de-energized modes. It can be stored in temperatures ranging from -40 to +85°C. The digital outputs consist of 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc DC-1 120W resistive load), and it features digital inputs of 1 x de-energized mode input (Y1-Y2) and 1 x latching input (Y3). The protection functions include overvoltage, with a response time of 0.1-10 s. | Pilz | Quick Quote |