Banner Engineering PIC120.241D is a fiber optic sensor designed for through-beam system applications, functioning as an opposed mode pair of individual fibers positioned side by side with right-angled sensing. It features a 1.5mm fiber core diameter and falls under the Plastic fiber series. The sensor has a cylindrical (threaded) end tip, constructed with a stainless steel sensing end and a polyethylene (PE) fiber sheath for durability. It is designed to operate in ambient air temperatures up to +70°C and has a total length of 6ft (2m), accommodating various industrial applications where precise and compact sensing solutions are required.
Quick Quote
PULS CP20.241 is a DIN rail mounting power supply unit with an aluminium housing. It operates within an ambient air temperature range of -25 to +70°C and has a net width of 48 mm. The unit features a current consumption of 5.5A peak max. inrush at 230Vac input and 12A peak max. inrush at 120Vac input. Its efficiency rates are 0.956 at 230Vac input, 0.942 at 120Vac input, and 0.936 at 100Vac input. The dimensions of the CP20.241 are W48mm x H124mm x D127mm. It has a 450ms start-up delay for 100-230Vac input, with rise times of 145ms and 160ms under nominal input conditions with 0mF and 20mF load capacitance, respectively. Protection functions include output overvoltage protection and overload/short-circuit protection, with the capability for series or parallel operation for increased output voltages or power. The unit is resistant to back-feeding loads up to 35V. Power dissipation/losses are 22.1 W at 230Vac input and 29.6 W at 120Vac input, with an output stage capacitance of 8500 µF. Electrical durability varies with conditions, offering up to 488000 hours of operation. The ripple is 50mVpp (20Hz...20MHz; 50Ω). This AC/DC power supply unit is part of the CP-series, designed with ATEX approval and a 20% power reserve, featuring a DC-OK relay contact output and screw-clamp connections. It supports a supply voltage range of 88Vdc-180Vdc and 85Vac-264Vac, with a rated current of 20A at 24Vdc, and provides a rated power of 480W. The output voltage is adjustable between 24Vdc and 28Vdc, with a 500mV turn-ON overshoot and a hold time of 32ms at 120/230Vac input.
Quick Quote
PULS CP20.241-R2 is a DIN rail mounting power supply unit housed in an aluminium casing, designed for a wide range of industrial applications. It operates within an ambient air temperature range of -40 to +70°C and offers a net width of 48mm. The unit consumes current differently based on the input voltage: 2.25A at 230Vac, 4.28A at 120Vac, 5.17A at 100Vac input for full output, and 4.64A at 110Vdc input for a 24Vdc / 10A output, with peak inrush currents of 5.5A at 230Vac and 12A at 120Vac. It boasts an efficiency of 0.952 at 230Vac input and 0.938 at 120Vac input. The dimensions are W48mm x H124mm x D127mm. The power supply features a 450ms start-up delay and a rise time of 145ms to 160ms under nominal input conditions. It includes protection functions such as output overvoltage protection and overload/short-circuit protection, with the capability for series or parallel operation for increased output voltages or power. The unit is resistant to back-feeding loads up to 35V. Power dissipation losses are 24.2W at 230Vac input and 31.7W at 120Vac input, with an output stage capacitance of 8000µF. Electrical durability ranges from 25,000 to 465,000 hours depending on the operating conditions. The ripple is specified at 100mVpp. This AC/DC power supply unit is part of the CP-series and is designed with built-in decoupling MOSFET for redundancy, hot-swappable connectors, and ATEX approval. It offers a 20% power reserve and features a DC-OK relay contact output. The connection type is hot-swappable connectors. Supply voltage ranges from 88Vdc to 180Vdc for DC and 85Vac to 264Vac for AC, with specific tolerances for overvoltage and shutdown voltages. The rated current is 24A at 48Vdc in temperatures up to +45°C, with derating at higher temperatures. It supports single-phase (1AC) or DC networks and provides a rated power of 576W at temperatures up to +45°C, with linear derating up to +70°C. The output voltage is fixed at 24Vdc, with a 1000mV turn-ON overshoot and a hold time of 32ms at 120/230Vac input.
Quick Quote
PULS SLA3.100 is a power supply unit designed with NEC Class 2 and ATEX approval, compliant with EN 61000-3-2 PFC norm, featuring a DC-OK relay contact output. It serves as an AS-Interface power supply unit (PSU) encased in a robust metal housing. This unit offers screw-clamp connections for secure installation and measures W49mm x H124mm x D102mm. It supports a wide range of supply voltages, including AC options from 85Vac to 264Vac and a DC option from 230Vdc to 375Vdc, with a rated current of 2.8A at 30.6Vdc. Designed for DIN rail mounting, it operates within an ambient air temperature range of -10 to +70 °C. The SLA3.100 experiences a peak inrush current consumption of 49.7A at 230Vac input and 44.7A at 120Vac input. It is suitable for single-phase (1AC) or DC networks and includes protection functions such as output overvoltage protection (up to 55Vdc max.), NTC for input inrush current limiting, and overload/short-circuit protection. The output voltage is fixed at 30.6Vdc, with an efficiency of 0.905 at 230Vac input, a hold time of 26ms at 100Vac input, power dissipation/losses of 9.1W at full output load, and a ripple of 50mVpp across 20Hz to 20MHz at 50Ω.
Quick Quote
PULS SLAD4.100 is a power supply unit designed with a PFC compliant to EN 61000-3-2 standards, featuring a DC-OK relay contact output. It serves as an AS-Interface power supply unit (PSU) and DC/DC-Converter, encased in a robust metal housing. This unit offers screw-clamp connections for secure installation and measures W40mm x H124mm x D102mm. It operates on a supply voltage range of 18Vdc-31.4Vdc, with a nominal 24Vdc, and delivers a rated current of 4A at 30.6Vdc, incorporating a derating curve from 3W/+60°C to +70°C. Designed for DIN rail mounting, it can function within an ambient air temperature range of -25°C to +70°C. The SLAD4.100 has a net width of 40 mm and a peak inrush current consumption of 1.8A. It is compatible with DC networks only and includes protection functions against output overvoltage (up to 36Vdc max.), with an active input inrush current limiter, and overload/short-circuit conditions (min. 5A/max. 12A current). Series or parallel operation is not supported. The output voltage is fixed at 30.6Vdc, with an efficiency of 0.905 at 24Vdc input. Power dissipation/losses are 12.7W at 24Vdc input with full output load. The unit features a 650ms start-up delay, a 100ms rise time under nominal input with constant full current load and 0mF load capacitance, and a 200ms rise time with 5mF load capacitance. Ripple is maintained at 50mVpp across a frequency range of 20Hz to 20MHz at 50Ω.
Quick Quote
PULS CD5.241 is a power supply unit designed for DIN rail mounting, featuring an aluminium housing and dimensions of W32mm x H124mm x D102mm. It operates within an ambient air temperature range of -25 to +70°C and has a net width of 32 mm. The unit consumes 5.5A current at a 24Vdc input to deliver a full 24Vdc output at 5A, with a peak inrush current of 1.6A. It boasts an efficiency of 0.903 at 24Vdc with a 5A input. The CD5.241 includes a 650ms start-up delay and an 800ms rise time under nominal input with a constant full current load and 0mF load capacitance. It offers protection functions such as output overvoltage protection, short-circuit protection with a minimum of 7A and a maximum of 10A continuous current, and allows for series or parallel operation for increased output power or 1+1 redundancy. The unit is capable of handling back-feeding loads up to 30V without malfunctioning, whether powered on or off, and includes reverse polarity protection. Power dissipation/losses are 12.9W under a 24Vdc input with a 24V output load at 5A, and 6.2W at 2.5A. The output stage capacitance is 2200 µF, and the electrical durability ranges from 37,000 to 185,000 hours depending on the operating conditions. It features a ripple of 50mVpp across 20Hz to 20MHz at 50Ω. This PSU/DC/DC-Converter offers a 20% power reserve, is part of the CD-series, and includes ATEX approval for galvanic isolation. Connection is facilitated via screw-clamp connections, with a supply voltage range of 18Vdc-32.4Vdc (24Vdc nominal) and 14.4-18Vdc for up to 60s. The rated current is 6A at 24Vdc from -25 to +45°C and 5A at +45 to +60°C, with a derating to 3W from +60 to +70°C. The rated power is 144W at ambient temperatures below 45°C and 120W below 60°C. The output voltage is adjustable between 23-28Vdc, with a 500mV turn-ON overshoot, and a hold time of 6ms at 24Vdc input.
Quick Quote
PULS CD5.243 is a power supply unit designed for DIN rail mounting, featuring an aluminium housing. It operates within an ambient air temperature range of -25 to +70°C and has a net width of 32mm. The unit consumes 9.2A current at 12Vdc input to deliver a full 24Vdc output at 4A, with a peak inrush current of 1.3A. It boasts an efficiency of 0.877 under a 24Vdc, 4A input. The dimensions are W32mm x H124mm x D102mm. It includes a 450ms start-up delay and an 80ms rise time under nominal input with a constant full current load. The CD5.243 offers protection against output overvoltage, short circuits, and allows for series or parallel operation to increase output power or achieve 1+1 redundancy for higher system availability. It is capable of handling back-feeding loads up to 30V without malfunctioning, regardless of the power supply's operational state. The unit features reverse polarity protection, with power dissipation losses of 13.5W under a 12Vdc input and 24V output load at 4A. The output stage capacitance is 2200µF, and it has an electrical durability ranging from 33,000 to 206,000 hours depending on the operating conditions. The ripple is maintained at 50mVpp across a 20Hz to 20MHz frequency range. This PSU/DC/DC-Converter includes a 20% power reserve, is part of the CD-series, and comes with ATEX approval and galvanic isolation. Connections are made via screw-clamp connections. The supply voltage ranges from 11Vdc to 16.2Vdc, with a rated current of 4.8A at 24Vdc in temperatures up to 45°C, and lower currents as the temperature increases up to 70°C. The rated power is 116W in ambient temperatures less than 45°C and 96W for temperatures less than 60°C. The output voltage is adjustable between 23-28Vdc, with a 300mV turn-ON overshoot and a hold time of 3ms.
Quick Quote
PULS CS10.243 is a DIN rail mounting power supply unit with an aluminium housing designed for a single-phase network. It operates within an ambient air temperature range of 0 to +70°C and has a net width of 60mm. The unit consumes 3.71A with a 120Vac input and 4.32A with a 100Vac input for a full 24Vdc output, featuring a peak inrush current of 108A at 120Vac input and 90A at 100Vac input. It offers an efficiency of 0.913 at 120Vac input and 0.91 at 100Vac input. The dimensions are W60mm x H124mm x D117mm. It includes a 250ms start-up delay for 100-120Vac input, with a rise time of 35ms under nominal input at constant full current load with 0mF load capacitance and 75ms with 10mF load capacitance. The power supply unit is equipped with protection functions including output overvoltage protection, NTC for input inrush current limiting, and overload/short-circuit protection. It supports series/parallel operation for redundancy and is resistant to back-feeding loads up to 35V. Power dissipation/losses are 22.9W at 120Vac input with full output load, and the output stage capacitance is 7000µF. Electrical durability ranges from 27,000 to 281,000 hours depending on conditions. Ripple is maintained at 50mVpp across a 20Hz to 20MHz range. This AC/DC power supply unit, part of the C-Line series, features a 20% power reserve, DC-OK relay contact output, and screw-clamp connections. It accepts a supply voltage of 90Vac-132Vac (47-63Hz) with a turn-ON voltage of 82Vac and a shutdown voltage of 78Vac in steady-state. The rated current is 12A at 24Vdc for ambient temperatures less than 45°C and 10A at 24Vdc for less than 60°C, with an adjustable output voltage of 24Vdc-28Vdc. The hold time is 46ms at 120Vac input.
Quick Quote
PULS CS5.243 is a DIN rail mounting power supply unit encased in an aluminium housing, designed for a single-phase network. It operates within an ambient air temperature range of -10 to +70°C and has a net width of 32mm. The unit consumes 1.88A with a 120Vac input and 2.23A with a 100Vac input for a full 24Vdc output, featuring a peak inrush current of 56A at 120Vac and 47A at 100Vac. It boasts an efficiency of 0.9 at 120Vac input and 0.895 at 100Vac input. The dimensions are W32mm x H124mm x D117mm. It has a 120ms start-up delay and a rise time of 8ms under nominal input with a constant full current load without load capacitance, and 25ms with 5mF load capacitance. The CS5.243 includes protection functions such as output overvoltage protection, NTC for input inrush current limiting, and overload/short-circuit protection. It supports series or parallel operation for redundancy and is resistant to back-feeding loads up to 35V. Power dissipation is 13.5W at full output load with a 120Vac input, and the output stage capacitance is 1800µF. Its electrical durability ranges from 27,000 to 363,000 hours depending on the conditions. The ripple is 50mVpp, and it features a 20% power reserve. Part of the C-Line series, it includes a DC-OK relay contact output and screw-clamp connections. The supply voltage ranges from 90Vac to 132Vac, with a rated current of 6A at 24Vdc under 45°C and a rated power of 144W under 45°C. The output voltage is adjustable between 24Vdc and 28Vdc, with a 400mV turn-ON overshoot and a hold time of 78ms at 120Vac input.
Quick Quote
PULS ML60.122 is a power supply unit (PSU) / converter designed for AC/DC applications with DIN rail mounting. It operates within an ambient air temperature range of -40 to +70°C and is designed for NEC Class 2 operation in cold environments down to -40°C. This unit has a rated current of 4.5A at 12Vdc and utilizes screw-clamp connections for connectivity. It supports a wide range of supply voltages from 85Vac to 264Vac (with specific nominal values listed) and from 88Vdc to 375Vdc, featuring a turn-ON voltage of 75Vac and a shutdown voltage of 65Vac. The ML60.122 measures 45mm in width, 75mm in height, and 91mm in depth, housed in a PC / ABS blend. It is compatible with single-phase (1AC) or DC networks, has a rated power of 54W, and offers an adjustable output voltage range of 12Vdc to 15Vdc with a 200mV turn-ON overshoot. The unit's protection functions include an active input inrush current limiter. Efficiency rates vary based on input voltage, with 0.876 at 230Vac, 0.858 at 120Vac, and 0.841 at 100Vac. It features a peak current consumption of 6A at 230Vac input, with specific time delays for start-up and rise times under different conditions. Power dissipation is noted at 7.6W, and the electrical durability is rated at a minimum of 56,000 hours at +40°C. The ripple is specified at 50mVpp across a 20Hz to 20MHz range with a 50Ω load, and the output stage capacitance is 3000µF.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
PIC120.241D Banner Engineering PIC120.241D is a fiber optic sensor designed for through-beam system applications, functioning as an opposed mode pair of individual fibers positioned side by side with right-angled sensing. It features a 1.5mm fiber core diameter and falls under the Plastic fiber series. The sensor has a cylindrical (threaded) end tip, constructed with a stainless steel sensing end and a polyethylene (PE) fiber sheath for durability. It is designed to operate in ambient air temperatures up to +70°C and has a total length of 6ft (2m), accommodating various industrial applications where precise and compact sensing solutions are required. | Puls | $175.00 | Quick Quote | ||
CP20.241 PULS CP20.241 is a DIN rail mounting power supply unit with an aluminium housing. It operates within an ambient air temperature range of -25 to +70°C and has a net width of 48 mm. The unit features a current consumption of 5.5A peak max. inrush at 230Vac input and 12A peak max. inrush at 120Vac input. Its efficiency rates are 0.956 at 230Vac input, 0.942 at 120Vac input, and 0.936 at 100Vac input. The dimensions of the CP20.241 are W48mm x H124mm x D127mm. It has a 450ms start-up delay for 100-230Vac input, with rise times of 145ms and 160ms under nominal input conditions with 0mF and 20mF load capacitance, respectively. Protection functions include output overvoltage protection and overload/short-circuit protection, with the capability for series or parallel operation for increased output voltages or power. The unit is resistant to back-feeding loads up to 35V. Power dissipation/losses are 22.1 W at 230Vac input and 29.6 W at 120Vac input, with an output stage capacitance of 8500 µF. Electrical durability varies with conditions, offering up to 488000 hours of operation. The ripple is 50mVpp (20Hz...20MHz; 50Ω). This AC/DC power supply unit is part of the CP-series, designed with ATEX approval and a 20% power reserve, featuring a DC-OK relay contact output and screw-clamp connections. It supports a supply voltage range of 88Vdc-180Vdc and 85Vac-264Vac, with a rated current of 20A at 24Vdc, and provides a rated power of 480W. The output voltage is adjustable between 24Vdc and 28Vdc, with a 500mV turn-ON overshoot and a hold time of 32ms at 120/230Vac input. | Puls | $500.00 | Quick Quote | ||
CP20.241-R2 PULS CP20.241-R2 is a DIN rail mounting power supply unit housed in an aluminium casing, designed for a wide range of industrial applications. It operates within an ambient air temperature range of -40 to +70°C and offers a net width of 48mm. The unit consumes current differently based on the input voltage: 2.25A at 230Vac, 4.28A at 120Vac, 5.17A at 100Vac input for full output, and 4.64A at 110Vdc input for a 24Vdc / 10A output, with peak inrush currents of 5.5A at 230Vac and 12A at 120Vac. It boasts an efficiency of 0.952 at 230Vac input and 0.938 at 120Vac input. The dimensions are W48mm x H124mm x D127mm. The power supply features a 450ms start-up delay and a rise time of 145ms to 160ms under nominal input conditions. It includes protection functions such as output overvoltage protection and overload/short-circuit protection, with the capability for series or parallel operation for increased output voltages or power. The unit is resistant to back-feeding loads up to 35V. Power dissipation losses are 24.2W at 230Vac input and 31.7W at 120Vac input, with an output stage capacitance of 8000µF. Electrical durability ranges from 25,000 to 465,000 hours depending on the operating conditions. The ripple is specified at 100mVpp. This AC/DC power supply unit is part of the CP-series and is designed with built-in decoupling MOSFET for redundancy, hot-swappable connectors, and ATEX approval. It offers a 20% power reserve and features a DC-OK relay contact output. The connection type is hot-swappable connectors. Supply voltage ranges from 88Vdc to 180Vdc for DC and 85Vac to 264Vac for AC, with specific tolerances for overvoltage and shutdown voltages. The rated current is 24A at 48Vdc in temperatures up to +45°C, with derating at higher temperatures. It supports single-phase (1AC) or DC networks and provides a rated power of 576W at temperatures up to +45°C, with linear derating up to +70°C. The output voltage is fixed at 24Vdc, with a 1000mV turn-ON overshoot and a hold time of 32ms at 120/230Vac input. | Puls | $660.00 | Quick Quote | ||
SLA3.100 PULS SLA3.100 is a power supply unit designed with NEC Class 2 and ATEX approval, compliant with EN 61000-3-2 PFC norm, featuring a DC-OK relay contact output. It serves as an AS-Interface power supply unit (PSU) encased in a robust metal housing. This unit offers screw-clamp connections for secure installation and measures W49mm x H124mm x D102mm. It supports a wide range of supply voltages, including AC options from 85Vac to 264Vac and a DC option from 230Vdc to 375Vdc, with a rated current of 2.8A at 30.6Vdc. Designed for DIN rail mounting, it operates within an ambient air temperature range of -10 to +70 °C. The SLA3.100 experiences a peak inrush current consumption of 49.7A at 230Vac input and 44.7A at 120Vac input. It is suitable for single-phase (1AC) or DC networks and includes protection functions such as output overvoltage protection (up to 55Vdc max.), NTC for input inrush current limiting, and overload/short-circuit protection. The output voltage is fixed at 30.6Vdc, with an efficiency of 0.905 at 230Vac input, a hold time of 26ms at 100Vac input, power dissipation/losses of 9.1W at full output load, and a ripple of 50mVpp across 20Hz to 20MHz at 50Ω. | Puls | $645.00 | Quick Quote | ||
SLAD4.100 PULS SLAD4.100 is a power supply unit designed with a PFC compliant to EN 61000-3-2 standards, featuring a DC-OK relay contact output. It serves as an AS-Interface power supply unit (PSU) and DC/DC-Converter, encased in a robust metal housing. This unit offers screw-clamp connections for secure installation and measures W40mm x H124mm x D102mm. It operates on a supply voltage range of 18Vdc-31.4Vdc, with a nominal 24Vdc, and delivers a rated current of 4A at 30.6Vdc, incorporating a derating curve from 3W/+60°C to +70°C. Designed for DIN rail mounting, it can function within an ambient air temperature range of -25°C to +70°C. The SLAD4.100 has a net width of 40 mm and a peak inrush current consumption of 1.8A. It is compatible with DC networks only and includes protection functions against output overvoltage (up to 36Vdc max.), with an active input inrush current limiter, and overload/short-circuit conditions (min. 5A/max. 12A current). Series or parallel operation is not supported. The output voltage is fixed at 30.6Vdc, with an efficiency of 0.905 at 24Vdc input. Power dissipation/losses are 12.7W at 24Vdc input with full output load. The unit features a 650ms start-up delay, a 100ms rise time under nominal input with constant full current load and 0mF load capacitance, and a 200ms rise time with 5mF load capacitance. Ripple is maintained at 50mVpp across a frequency range of 20Hz to 20MHz at 50Ω. | Puls | $875.00 | Quick Quote | ||
CD5.241 PULS CD5.241 is a power supply unit designed for DIN rail mounting, featuring an aluminium housing and dimensions of W32mm x H124mm x D102mm. It operates within an ambient air temperature range of -25 to +70°C and has a net width of 32 mm. The unit consumes 5.5A current at a 24Vdc input to deliver a full 24Vdc output at 5A, with a peak inrush current of 1.6A. It boasts an efficiency of 0.903 at 24Vdc with a 5A input. The CD5.241 includes a 650ms start-up delay and an 800ms rise time under nominal input with a constant full current load and 0mF load capacitance. It offers protection functions such as output overvoltage protection, short-circuit protection with a minimum of 7A and a maximum of 10A continuous current, and allows for series or parallel operation for increased output power or 1+1 redundancy. The unit is capable of handling back-feeding loads up to 30V without malfunctioning, whether powered on or off, and includes reverse polarity protection. Power dissipation/losses are 12.9W under a 24Vdc input with a 24V output load at 5A, and 6.2W at 2.5A. The output stage capacitance is 2200 µF, and the electrical durability ranges from 37,000 to 185,000 hours depending on the operating conditions. It features a ripple of 50mVpp across 20Hz to 20MHz at 50Ω. This PSU/DC/DC-Converter offers a 20% power reserve, is part of the CD-series, and includes ATEX approval for galvanic isolation. Connection is facilitated via screw-clamp connections, with a supply voltage range of 18Vdc-32.4Vdc (24Vdc nominal) and 14.4-18Vdc for up to 60s. The rated current is 6A at 24Vdc from -25 to +45°C and 5A at +45 to +60°C, with a derating to 3W from +60 to +70°C. The rated power is 144W at ambient temperatures below 45°C and 120W below 60°C. The output voltage is adjustable between 23-28Vdc, with a 500mV turn-ON overshoot, and a hold time of 6ms at 24Vdc input. | Puls | $385.00 | Quick Quote | ||
CD5.243 PULS CD5.243 is a power supply unit designed for DIN rail mounting, featuring an aluminium housing. It operates within an ambient air temperature range of -25 to +70°C and has a net width of 32mm. The unit consumes 9.2A current at 12Vdc input to deliver a full 24Vdc output at 4A, with a peak inrush current of 1.3A. It boasts an efficiency of 0.877 under a 24Vdc, 4A input. The dimensions are W32mm x H124mm x D102mm. It includes a 450ms start-up delay and an 80ms rise time under nominal input with a constant full current load. The CD5.243 offers protection against output overvoltage, short circuits, and allows for series or parallel operation to increase output power or achieve 1+1 redundancy for higher system availability. It is capable of handling back-feeding loads up to 30V without malfunctioning, regardless of the power supply's operational state. The unit features reverse polarity protection, with power dissipation losses of 13.5W under a 12Vdc input and 24V output load at 4A. The output stage capacitance is 2200µF, and it has an electrical durability ranging from 33,000 to 206,000 hours depending on the operating conditions. The ripple is maintained at 50mVpp across a 20Hz to 20MHz frequency range. This PSU/DC/DC-Converter includes a 20% power reserve, is part of the CD-series, and comes with ATEX approval and galvanic isolation. Connections are made via screw-clamp connections. The supply voltage ranges from 11Vdc to 16.2Vdc, with a rated current of 4.8A at 24Vdc in temperatures up to 45°C, and lower currents as the temperature increases up to 70°C. The rated power is 116W in ambient temperatures less than 45°C and 96W for temperatures less than 60°C. The output voltage is adjustable between 23-28Vdc, with a 300mV turn-ON overshoot and a hold time of 3ms. | Puls | $435.00 | Quick Quote | ||
CS10.243 PULS CS10.243 is a DIN rail mounting power supply unit with an aluminium housing designed for a single-phase network. It operates within an ambient air temperature range of 0 to +70°C and has a net width of 60mm. The unit consumes 3.71A with a 120Vac input and 4.32A with a 100Vac input for a full 24Vdc output, featuring a peak inrush current of 108A at 120Vac input and 90A at 100Vac input. It offers an efficiency of 0.913 at 120Vac input and 0.91 at 100Vac input. The dimensions are W60mm x H124mm x D117mm. It includes a 250ms start-up delay for 100-120Vac input, with a rise time of 35ms under nominal input at constant full current load with 0mF load capacitance and 75ms with 10mF load capacitance. The power supply unit is equipped with protection functions including output overvoltage protection, NTC for input inrush current limiting, and overload/short-circuit protection. It supports series/parallel operation for redundancy and is resistant to back-feeding loads up to 35V. Power dissipation/losses are 22.9W at 120Vac input with full output load, and the output stage capacitance is 7000µF. Electrical durability ranges from 27,000 to 281,000 hours depending on conditions. Ripple is maintained at 50mVpp across a 20Hz to 20MHz range. This AC/DC power supply unit, part of the C-Line series, features a 20% power reserve, DC-OK relay contact output, and screw-clamp connections. It accepts a supply voltage of 90Vac-132Vac (47-63Hz) with a turn-ON voltage of 82Vac and a shutdown voltage of 78Vac in steady-state. The rated current is 12A at 24Vdc for ambient temperatures less than 45°C and 10A at 24Vdc for less than 60°C, with an adjustable output voltage of 24Vdc-28Vdc. The hold time is 46ms at 120Vac input. | Puls | $355.00 | Quick Quote | ||
CS5.243 PULS CS5.243 is a DIN rail mounting power supply unit encased in an aluminium housing, designed for a single-phase network. It operates within an ambient air temperature range of -10 to +70°C and has a net width of 32mm. The unit consumes 1.88A with a 120Vac input and 2.23A with a 100Vac input for a full 24Vdc output, featuring a peak inrush current of 56A at 120Vac and 47A at 100Vac. It boasts an efficiency of 0.9 at 120Vac input and 0.895 at 100Vac input. The dimensions are W32mm x H124mm x D117mm. It has a 120ms start-up delay and a rise time of 8ms under nominal input with a constant full current load without load capacitance, and 25ms with 5mF load capacitance. The CS5.243 includes protection functions such as output overvoltage protection, NTC for input inrush current limiting, and overload/short-circuit protection. It supports series or parallel operation for redundancy and is resistant to back-feeding loads up to 35V. Power dissipation is 13.5W at full output load with a 120Vac input, and the output stage capacitance is 1800µF. Its electrical durability ranges from 27,000 to 363,000 hours depending on the conditions. The ripple is 50mVpp, and it features a 20% power reserve. Part of the C-Line series, it includes a DC-OK relay contact output and screw-clamp connections. The supply voltage ranges from 90Vac to 132Vac, with a rated current of 6A at 24Vdc under 45°C and a rated power of 144W under 45°C. The output voltage is adjustable between 24Vdc and 28Vdc, with a 400mV turn-ON overshoot and a hold time of 78ms at 120Vac input. | Puls | $265.00 | Quick Quote | ||
ML60.122 PULS ML60.122 is a power supply unit (PSU) / converter designed for AC/DC applications with DIN rail mounting. It operates within an ambient air temperature range of -40 to +70°C and is designed for NEC Class 2 operation in cold environments down to -40°C. This unit has a rated current of 4.5A at 12Vdc and utilizes screw-clamp connections for connectivity. It supports a wide range of supply voltages from 85Vac to 264Vac (with specific nominal values listed) and from 88Vdc to 375Vdc, featuring a turn-ON voltage of 75Vac and a shutdown voltage of 65Vac. The ML60.122 measures 45mm in width, 75mm in height, and 91mm in depth, housed in a PC / ABS blend. It is compatible with single-phase (1AC) or DC networks, has a rated power of 54W, and offers an adjustable output voltage range of 12Vdc to 15Vdc with a 200mV turn-ON overshoot. The unit's protection functions include an active input inrush current limiter. Efficiency rates vary based on input voltage, with 0.876 at 230Vac, 0.858 at 120Vac, and 0.841 at 100Vac. It features a peak current consumption of 6A at 230Vac input, with specific time delays for start-up and rise times under different conditions. Power dissipation is noted at 7.6W, and the electrical durability is rated at a minimum of 56,000 hours at +40°C. The ripple is specified at 50mVpp across a 20Hz to 20MHz range with a 50Ω load, and the output stage capacitance is 3000µF. | Puls | $220.00 | Quick Quote |