LC7K0901M7 Schneider Electric Industrial Automation Components

LC7K0901M7 on Powermatic Associates
Schneider Electric

Part#:LC7K0901M7

Manufacturer:Schneider Electric

Category:Industrial Automation Components

Product Lifecycle:Active

Product description

Schneider Electric LC7K0901M7 is a contactor from the K sub-range designed with a silent magnetic operation and a built-in surge suppressor. It features screw connections and has 3 poles (3P; 3NO) with a rated current of 20A (AC-1) and 9A (440Vac; AC-3). The contactor offers a degree of protection of IP20 and operates with a control voltage (AC) of 176-242Vac (220Vac nom.; 50Hz/60Hz; 0.8...1.1 x Uc). Its rated operating voltage (Ue) is 690 V, and it comes with 0 Normally Open (NO) auxiliary contacts and 1 Normally Closed (NC) auxiliary contact. The rated impulse voltage (Uimp) is 8 kV, and it supports rated active power (kW) of 2.2kW (220-230Vac; AC-3), 4kW (380-415Vac; AC-3), 4kW (440Vac; AC-3), 4kW (500Vac; AC-3), and 4kW (660-690Vac; AC-3). Its mechanical durability at no load is rated for 10,000,000 operations, and the rated voltage (AC) phase-to-phase is 690 V.

Product Details

  • [Ui] Rated Insulation Voltage
    Power circuit 600 V UL 508 Power circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-5-1 Signalling circuit 600 V UL 508 Power circuit 600 V CSA C22.2 No 14 Signalling circuit
  • Motor Power Kw
    2.2 kW 220...230 V AC 50/60 Hz AC-3 4 kW 380...415 V AC 50/60 Hz AC-3 4 kW 440 V AC 50/60 Hz AC-3 4 kW 480 V AC 50/60 Hz AC-3 4 kW 500...600 V AC 50/60 Hz AC-3 4 kW 660...690 V AC 50/60 Hz AC-3 2.2 kW 400 V AC 50/60 Hz AC-4
  • Rated Breaking Capacity
    110 A 415 V IEC 60947 110 A 440 V IEC 60947 80 A 500 V IEC 60947 110 A 220...230 V IEC 60947 110 A 380...400 V IEC 60947 70 A 660...690 V IEC 60947
  • [Icw] Rated Short-Time Withstand Current
    90 A 122 °F (50 °C) - 1 s power circuit 85 A 122 °F (50 °C) - 5 s power circuit 80 A 122 °F (50 °C) - 10 s power circuit 60 A 122 °F (50 °C) - 30 s power circuit 45 A 122 °F (50 °C) - 1 min power circuit 40 A 122 °F (50 °C) - 3 mi
  • Associated Fuse Rating
    25 A gG <= 440 V power circuit 25 A aM power circuit 10 A gG signalling circuit IEC 60947 10 A gG signalling circuit VDE 0660
  • Connections - Terminals
    screw clamp terminals 1 0.00…0.01 in² (1.5…4 mm²)solid screw clamp terminals 1 0.00…0.01 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 1 0.00…0.00 in² (0.34…2.5 mm²)flexible with cable end screw clamp terminals 2 0.00…
  • Mechanical Robustness
    Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 Shocks contac
  • [Ie] Rated Operational Current
    20 A 122 °F (50 °C)) <= 440 V AC AC-1 power circuit 9 A<= 440 V AC AC-3 power circuit 16 A 158 °F (70 °C)) 690 V AC AC-1 power circuit
  • Irms Rated Making Capacity
    110 A AC power circuit NF C 63-110 110 A AC power circuit IEC 60947 110 A AC signalling circuit IEC 60947
  • Utilisation Category
    AC-4 AC-3 AC-1
  • Safety Reliability Level
    B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • Operating Time
    30...40 ms coil energisation and NO closing 30 ms coil de-energisation and NO opening
  • Electrical Durability
    0.18 Mcycles 20 A AC-1 <= 440 V 1.3 Mcycles 9 A AC-3 <= 440 V
  • Tightening Torque
    11.51 lbf.in (1.3 N.m) screw clamp terminals Philips No 2 11.51 lbf.in (1.3 N.m) screw clamp terminals flat Ø 6 mm
  • Contactor Application
    Resistive load Motor control
  • [Ue] Rated Operational Voltage
    Power circuit 690 V AC 50/60 Hz Signalling circuit <= 690 V AC 50/60 Hz
  • Mounting Support
    Rail Plate
  • Control Circuit Voltage Limits
    Operational 0.85...1.1 Uc 122 °F (50 °C)) Drop-out 0.1...0.75 Uc 122 °F (50 °C))
  • [Ith] Conventional Free Air Thermal Current
    20 A 122 °F (50 °C) power circuit 10 A 122 °F (50 °C) signalling circuit
  • Width
    1.77 in (45 mm)
  • Net Weight
    0.50 lb(US) (0.225 kg)
  • Mechanical Durability
    10 Mcycles
  • Non Overlap Distance
    0.02 in (0.5 mm)
  • Depth
    2.24 in (57 mm)
  • Height
    2.28 in (58 mm)
  • Minimum Switching Voltage
    17 V signalling circuit
  • Minimum Switching Current
    5 mA signalling circuit
  • Maximum Operating Rate
    3600 cyc/h
  • Signalling Circuit Frequency
    <= 400 Hz
  • Auxiliary Contacts Type
    type instantaneous 1 NC
  • Heat Dissipation
    3 W
  • Hold-In Power Consumption In VA
    3 VA 68 °F (20 °C))
  • Insulation Resistance
    > 10 MOhm for signalling circuit
  • Inrush Power In VA
    3 VA 68 °F (20 °C))
  • Average Impedance
    3 mOhm - Ith 20 A 50 Hz power circuit
  • [Uimp] Rated Impulse Withstand Voltage
    8 kV
  • Auxiliary Contact Composition
    1 NC
  • Overvoltage Category
    III
  • [Uc] Control Circuit Voltage
    220...230 V AC 50/60 Hz
  • Control Circuit Type
    AC at 50/60 Hz silent
  • Power Pole Contact Composition
    3 NO
  • Poles Description
    3P
  • Product Name
    TeSys K
  • Range
    TeSys
  • Product Or Component Type
    Contactor
  • Device Short Name
    LC7K
  • Device Application
    Control

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of LC7K0901M7 on Powermatic Associates is $130.68. Order now.



Similar products from: Schneider Electric Industrial Automation Components

Manufacturer warranty

LC7K0901M7 Schneider Electric

$130.68

Your price can be lower.
Log in or Create account to check your discount

Select Qty:

$130.68

$130.68 each

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare LC7K0901M7 with other Industrial Automation Components products

[Ui] Rated Insulation Vol...

Motor Power Kw

Rated Breaking Capacity

[Icw] Rated Short-Time Wi...

Associated Fuse Rating

Connections - Terminals

Mechanical Robustness

[Ie] Rated Operational Cu...

Irms Rated Making Capacit...

Utilisation Category

Selected product

LC7K0901M7
Backordered
LC7K0901M7
Schneider Electric

Schneider Electric LC7K0901M7 is a contactor from the K sub-range designed with a silent magnetic op...

[Ui] Rated Insulation VoltagePower circuit 600 V UL 508 P...

Motor Power Kw2.2 kW 220...230 V AC 50/60 ...

Rated Breaking Capacity110 A 415 V IEC 60947 110 A ...

[Icw] Rated Short-Time Withstand Current90 A 122 °F (50 °C) - 1 s po...

Associated Fuse Rating25 A gG <= 440 V power circu...

Connections - Terminalsscrew clamp terminals 1 0.00...

Mechanical RobustnessShocks contactor closed, on ...

[Ie] Rated Operational Current20 A 122 °F (50 °C)) <= 440 ...

Irms Rated Making Capacity110 A AC power circuit NF C ...

Utilisation CategoryAC-4 AC-3 AC-1

LC1D95G7
11 in stock
LC1D95G7
Schneider Electric

Schneider Electric LC1D95G7 is a magnetic contactor from the Deca sub-range, featuring screw connect...

[Ui] Rated Insulation Voltage-

Motor Power Kw-

Rated Breaking Capacity-

[Icw] Rated Short-Time Withstand Current-

Associated Fuse Rating-

Connections - Terminals-

Mechanical Robustness-

[Ie] Rated Operational Current95 A 140 °F (60 °C)) <= 440 ...

Irms Rated Making Capacity-

Utilisation CategoryAC-4 AC-3 AC-1

LC1D326BD
3 in stock
LC1D326BD
Schneider Electric

Schneider Electric LC1D326BD is a magnetic contactor from the Deca sub-range, designed with ring-lug...

[Ui] Rated Insulation Voltage-

Motor Power Kw-

Rated Breaking Capacity-

[Icw] Rated Short-Time Withstand Current-

Associated Fuse Rating-

Connections - Terminals-

Mechanical Robustness-

[Ie] Rated Operational Current32 A 140 °F (60 °C)) <= 440 ...

Irms Rated Making Capacity-

Utilisation CategoryAC-3 AC-4 AC-1

About the manufacturer

Schneider Electric

Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...

Recently viewed products

Relevant products

FAQ

What is the price of LC7K0901M7?
Purchase the LC7K0901M7 from Powermatic Associates at the price of $130.68. Order today.

Out if stock but available for backorder.

Schneider Electric LC7K0901M7 is a contactor from the K sub-range designed with a silent magnetic operation and a built-in surge suppressor. It features screw connections and has 3 poles (3P; 3NO) with a rated current of 20A (AC-1) and 9A (440Vac; AC-3). The contactor offers a degree of protection of IP20 and operates with a control voltage (AC) of 176-242Vac (220Vac nom.; 50Hz/60Hz; 0.8...1.1 x Uc). Its rated operating voltage (Ue) is 690 V, and it comes with 0 Normally Open (NO) auxiliary contacts and 1 Normally Closed (NC) auxiliary contact. The rated impulse voltage (Uimp) is 8 kV, and it supports rated active power (kW) of 2.2kW (220-230Vac; AC-3), 4kW (380-415Vac; AC-3), 4kW (440Vac; AC-3), 4kW (500Vac; AC-3), and 4kW (660-690Vac; AC-3). Its mechanical durability at no load is rated for 10,000,000 operations, and the rated voltage (AC) phase-to-phase is 690 V.

Similar products from: Industrial Automation Components

What can I help you find today?

Recommended parts