LC1F150G7 Schneider Electric Electronic Components

Schneider Electric LC1F150G7 Schneider Electric LC1F150G7 is a high-power magnetic contactor within the F sub-range, designed for surface mounting. It features a 3-pole (3P; 3NO) configuration with ring-lugs/bar connections for electrical interfacing. The contactor is rated for currents of 250A under AC-1 conditions and 150A at 440Vac under AC-3 conditions. It operates with a control voltage range of 102-132Vac (120Vac nominal; 40-400Hz; 0.85...1.1 x Uc) and can handle a rated operating voltage (Ue) up to 1000 V. This model does not include normally open (NO) or normally closed (NC) auxiliary contacts. It is capable of switching rated active power loads of up to 40kW at 220-230Vac, 75kW at 380-400Vac, 80kW at both 415Vac and 440Vac, 90kW at 500Vac, 100kW at 660-690Vac, and 65kW at 1000Vac, all under AC-3 conditions. The LC1F150G7 is designed to withstand a rated impulse voltage (Uimp) of 8 kV and offers a mechanical durability of 10 million operations at no load, with a phase-to-phase rated voltage of 1000 V.
Schneider Electric

Part#:LC1F150G7

Manufacturer:Schneider Electric

Product Lifecycle:Active

Get a quick Quote!

Schneider Electric LC1F150G7 is a high-power magnetic contactor within the F sub-range, designed for surface mounting. It features a 3-pole (3P; 3NO) configuration with ring-lugs/bar connections for electrical interfacing. The contactor is rated for currents of 250A under AC-1 conditions and 150A at 440Vac under AC-3 conditions. It operates with a control voltage range of 102-132Vac (120Vac nominal; 40-400Hz; 0.85...1.1 x Uc) and can handle a rated operating voltage (Ue) up to 1000 V. This model does not include normally open (NO) or normally closed (NC) auxiliary contacts. It is capable of switching rated active power loads of up to 40kW at 220-230Vac, 75kW at 380-400Vac, 80kW at both 415Vac and 440Vac, 90kW at 500Vac, 100kW at 660-690Vac, and 65kW at 1000Vac, all under AC-3 conditions. The LC1F150G7 is designed to withstand a rated impulse voltage (Uimp) of 8 kV and offers a mechanical durability of 10 million operations at no load, with a phase-to-phase rated voltage of 1000 V.

About the manufacturer: Schneider Electric is one of the manufacturers that offers Electronic Components that you can order at Powermatic Associates site. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.

Check out the LC1F150G7 Schneider Electric price in the box on the right side or send a quick quote.

Product Details

  • Product Certifications
    CB UL RMRoS BV RINA LROS (Lloyds register of shipping) DNV CCC ABS UKCA
  • Motor Power Kw
    75 kW 380...400 V AC 50/60 Hz AC-3) 80 kW 415 V AC 50/60 Hz AC-3) 80 kW 440 V AC 50/60 Hz AC-3) 90 kW 500 V AC 50/60 Hz AC-3) 100 kW 660...690 V AC 50/60 Hz AC-3) 40 kW 220...230 V AC 50/60 Hz AC-3) 22 kW 400 V AC 50/60 Hz AC
  • Standards
    JIS C8201-4-1 IEC 60947-1 EN 60947-4-1 IEC 60947-4-1 EN 60947-1
  • Utilisation Category
    AC-4 AC-3 AC-1
  • [Icw] Rated Short-Time Withstand Current
    1200 A 104 °F (40 °C) - 10 s 700 A 104 °F (40 °C) - 30 s 600 A 104 °F (40 °C) - 1 min 450 A 104 °F (40 °C) - 3 min 350 A 104 °F (40 °C) - 10 min
  • Connections - Terminals
    Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)fl
  • Operating Time
    35 ms closing at Uc) 130 ms opening at Uc)
  • Power Dissipation Per Pole
    22 W AC-1 8 W AC-3
  • Control Circuit Voltage Limits
    Operational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C)) Drop-out 0.35...0.55 Uc 40...400 Hz 131 °F (55 °C))
  • [Ie] Rated Operational Current
    250 A 104 °F (40 °C)) <= 440 V AC-1 150 A 131 °F (55 °C)) <= 440 V AC-3
  • [Ui] Rated Insulation Voltage
    1000 V IEC 60947-4-1 1500 V VDE 0110 group C
  • Associated Fuse Rating
    160 A aM <= 440 V 250 A gG <= 440 V
  • Tightening Torque
    Control circuit 10.62 lbf.in (1.2 N.m) Power circuit 159.31 lbf.in (18 N.m)
  • Contactor Application
    Motor control Resistive load
  • Compatibility Code
    LC1F
  • Heat Dissipation
    5.9…7.2 W
  • Maximum Operating Rate
    2400 cyc/h 55 °C
  • Mechanical Durability
    10 Mcycles
  • Hold-In Power Consumption In VA
    8.1 VA 40...400 Hz 0.9 68 °F (20 °C))
  • Inrush Power In VA
    770 VA 40...400 Hz 0.9 68 °F (20 °C))
  • Mounting Support
    Plate
  • Average Impedance
    0.35 mOhm - Ith 250 A 50 Hz
  • [Ith] Conventional Free Air Thermal Current
    250 A 104 °F (40 °C)
  • Rated Breaking Capacity
    1200 A IEC 60947-4-1
  • Overvoltage Category
    III
  • [Uc] Control Circuit Voltage
    120 V AC 40...400 Hz
  • [Uimp] Rated Impulse Withstand Voltage
    8 kV
  • [Ue] Rated Operational Voltage
    <= 690 V AC 50/60 Hz
  • Power Pole Contact Composition
    3 NO
  • Poles Description
    3P
  • Device Short Name
    LC1F
  • Range
    TeSys
  • Product Or Component Type
    Contactor
  • Product Name
    TeSys F

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.



Manufacturer warranty

$696.00

Request a quote, and we will send availability within minutes.

Select Qty:

$696.00

$696.00 each

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Relevant products

What can I help you find today?

Recommended parts

UBC10.241

UBC10.241

PULS UBC10.241 is an Uninterruptible Power Supply (UPS) control module within the U-series, featuring a built-in battery with a 50% power reserve and a green status LED. This module is housed in aluminium and utilizes spring-clamp connections for installation. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can reach up to 15A in buffer mode for less than 5 seconds at full output voltage. It supports DIN rail mounting and can operate in ambient air temperatures ranging from 0 to +40°C. The current consumption is 1.1A at a 24Vdc input, and it is designed for DC networks. Visual position indicators include Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. It is advised not to use the DC-UPS in parallel to increase output power, but paralleling two units for 1+1 redundancy is possible for higher system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. The efficiency is rated at 0.978 with a 24Vdc input, and the rated power is 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W with a 24Vdc input at 0A output current and 5.5W at 10A output current. Ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. The electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output.

Puls