HDF36035
Schneider Electric
Product Lifecycle: Active
Square D by Schneider Electric HDF36035 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT HDF sub-range, featuring a PowerPact H-Frame 150 TMD design. It is a 3-pole (3P) device with a rated current of 35A and offers thermal protection for overload and magnetic protection for short-circuit scenarios. This MCCB has a rated insulation voltage (Ui) of 750 V, with AC rated voltages of 600Vac and 600Y/347Vac, and a DC rated voltage of 250Vdc. It is designed for individual unit mount on plate with a Term. nut kit for fixed busbar connection on both line and load sides. The HDF36035 has a net height of 163 mm, a net width of 104 mm, and a net depth of 86 mm, featuring an IP40 degree of protection. Its operating mode is manual toggle, with over-current protection settings fixed at 35A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 850A. The rated operating voltage (Ue) is 690 V, with a rated impulse voltage (Uimp) of 8 kV. The trip current rating is 35 AT, with a frame current rating of 150 AF. Its short circuit breaking rating varies with voltage, including 25kA at 240Vac, 18kA at 480Vac and 480Y/277Vac, 14kA at 600Vac and 600Y/347Vac, and 20kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display, and it falls under utilisation category A.
![HDF36035](/_next/image?url=https%3A%2F%2Fappstoragepublicprod.s3.us-west-1.amazonaws.com%2FPartImage%2Fb6f2ff70-4697-4607-ac2d-a0f2e8760d4d-1631039935454.jpg&w=3840&q=75)
Square D by Schneider Electric HDF36035 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT HDF sub-range, featuring a PowerPact H-Frame 150 TMD design. It is a 3-pole (3P) device with a rated current of 35A and offers thermal protection for overload and magnetic protection for short-circuit scenarios. This MCCB has a rated insulation voltage (Ui) of 750 V, with AC rated voltages of 600Vac and 600Y/347Vac, and a DC rated voltage of 250Vdc. It is designed for individual unit mount on plate with a Term. nut kit for fixed busbar connection on both line and load sides. The HDF36035 has a net height of 163 mm, a net width of 104 mm, and a net depth of 86 mm, featuring an IP40 degree of protection. Its operating mode is manual toggle, with over-current protection settings fixed at 35A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 850A. The rated operating voltage (Ue) is 690 V, with a rated impulse voltage (Uimp) of 8 kV. The trip current rating is 35 AT, with a frame current rating of 150 AF. Its short circuit breaking rating varies with voltage, including 25kA at 240Vac, 18kA at 480Vac and 480Y/277Vac, 14kA at 600Vac and 600Y/347Vac, and 20kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display, and it falls under utilisation category A.
Product details
- Electrical ConnectionBusbar connection line Busbar connection load
- Continuous Current Rating80 %
- Width4.12 in (104.65 mm)
- Depth4.36 in (110.74 mm)
- Tightening Torque44.25 lbf.in (5 N.m) 0.00…0.15 in² (2.5…95 mm²) (AWG 14...AWG 3/0)
- Breaking Capacity CodeD
- Height6.4 in (162.56 mm)
- Magnetic Tripping Current850 A
- Magnetic Hold Current400 A
- Mounting ModeUnit mount
- Number Of Poles3P
- Line Rated Current35 A
- Product Or Component TypeCircuit breaker
- Range Of ProductPowerPact H
This part can ship within 24 hours
$1,109.76
Stock:
1
Select Qty:
$1,109.76
$1,109.76 each
This part can ship within 24h!
Fast worldwide Shipping and Delivery
Shipping cost will be calculated during checkout
Payments methods
Secure Payment Processing
with money back guarantee
1 year warranty on all parts
Responsive Customer Support
with personalized assistance
Need more details?
Feel free to chat with us.