LC1D806BD Schneider Electric Industrial Automation Components
Part#:LC1D806BD
Manufacturer:Schneider Electric
Product Lifecycle:Active
Get a quick Quote!
IEC contactor, TeSys Deca, nonreversing, 80A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VDC coil, open style
About the manufacturer: Schneider Electric is one of the manufacturers that offers Industrial Automation Components that you can order at Powermatic Associates site. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.
Check out the LC1D806BD Schneider Electric price in the box on the right side or send a quick quote.
Product Details
- Product Certifications LROS (Lloyds register of shipping) CCC DNV GL GOST RINA BV UL CSA
- Motor Power Kw 22 kW 220...230 V AC 50/60 Hz AC-3) 37 kW 380...400 V AC 50/60 Hz AC-3) 45 kW 415...440 V AC 50/60 Hz AC-3) 55 kW 500 V AC 50/60 Hz AC-3) 45 kW 660...690 V AC 50/60 Hz AC-3) 45 kW 1000 V AC 50/60 Hz AC-3) 15 kW 400 V AC 50/60
- Motor Power HP (UL / CSA) 20 hp 200/208 V at AC 50/60 Hz for 3 phase 7.5 hp 115 V at AC 50/60 Hz for 1 phase 15 hp 230/240 V at AC 50/60 Hz for 1 phase 25 hp 230/240 V at AC 50/60 Hz for 3 phase 60 hp 460/480 V at AC 50/60 Hz for 3 phase 60 hp 575/600 V at
- [Icw] Rated Short-Time Withstand Current 640 A 104 °F (40 °C) - 10 s power circuit 990 A 104 °F (40 °C) - 1 s power circuit 135 A 104 °F (40 °C) - 10 min power circuit 320 A 104 °F (40 °C) - 1 min power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling cir
- [Ui] Rated Insulation Voltage Power circuit 600 V CSA Power circuit 600 V UL Power circuit 1000 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL
- Standards CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
- Tightening Torque Control circuit 10.62 lbf.in (1.2 N.m) lugs-ring terminals flat Ø 6 mm M3.5 Control circuit 10.62 lbf.in (1.2 N.m) lugs-ring terminals Philips No 2 M3.5 Power circuit 106.21 lbf.in (12 N.m) lugs-ring terminals flat Ø 8 mm M6 Power circuit 1
- Irms Rated Making Capacity 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 1100 A 440 V power circuit IEC 60947
- Control Circuit Voltage Limits 0.1...0.3 Uc -40…158 °F (-40…70 °C) drop-out DC 0.85...1.1 Uc -40…131 °F (-40…55 °C) operational DC 1...1.1 Uc 131…158 °F (55…70 °C) operational DC
- Connections - Terminals Control circuit lugs-ring terminals 0.31 in (8 mm)) Power circuit bars 1 3 x 16 mm Power circuit lugs-ring terminals 0.67 in (17 mm))
- Associated Fuse Rating 10 A gG signalling circuit IEC 60947-5-1 200 A gG <= 690 V type 1 power circuit 160 A gG <= 690 V type 2 power circuit
- Utilisation Category AC-3 AC-4 AC-1
- Auxiliary Contacts Type Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
- [Ie] Rated Operational Current 125 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit 80 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit
- [Ue] Rated Operational Voltage Power circuit <= 300 V DC 25...400 Hz Power circuit <= 690 V AC
- Contactor Application Resistive load Motor control
- [Ith] Conventional Free Air Thermal Current 10 A 140 °F (60 °C) signalling circuit 125 A 140 °F (60 °C) power circuit
- Mounting Support Rail Plate
- Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Non-Overlap Time 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
- Operating Time 95...130 ms closing 20...35 ms opening
- Electrical Durability 0.8 Mcycles 125 A AC-1 <= 440 V 1.5 Mcycles 80 A AC-3 <= 440 V
- Power Dissipation Per Pole 5.1 W AC-3 12.5 W AC-1
- Minimum Switching Current 5 mA signalling circuit
- Hold-In Power Consumption In W 22 W 68 °F (20 °C)
- Inrush Power In W 22 W 68 °F (20 °C))
- Coil Technology Without built-in suppressor module
- Time Constant 75 ms
- Insulation Resistance > 10 MOhm signalling circuit
- Minimum Switching Voltage 17 V signalling circuit
- Signalling Circuit Frequency 25...400 Hz
- Maximum Operating Rate 3600 cyc/h 140 °F (60 °C)
- Mechanical Durability 75 Mcycles
- Front Cover With
- Average Impedance 0.8 mOhm - Ith 125 A 50 Hz power circuit
- Rated Breaking Capacity 1100 A 440 V power circuit IEC 60947
- Control Circuit Type DC standard
- Overvoltage Category III
- [Uimp] Rated Impulse Withstand Voltage 8 kV IEC 60947
- Auxiliary Contact Composition 1 NO + 1 NC
- [Uc] Control Circuit Voltage 24 V DC
- Device Short Name LC1D
- Power Pole Contact Composition 3 NO
- Poles Description 3P
- Range TeSys
- Product Or Component Type Contactor
- Product Name TeSys D
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Related documents LC1D806BD Specs
Manufacturer warranty
$447.00
Request a quote, and we will send availability within minutes.