LC1D326B7 Schneider Electric Industrial Automation Components
Part#:LC1D326B7
Manufacturer:Schneider Electric
Product Lifecycle:Active
In-stock parts: 1
Sep 28, 2024
IEC contactor, TeSys Deca, nonreversing, 32A, 20HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VAC 50/60Hz coil, open style
About the manufacturer: Schneider Electric is one of the manufacturers that offers Industrial Automation Components that you can order at Powermatic Associates site. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.
Check out the LC1D326B7 Schneider Electric price in the box on the right side or send a quick quote.
Product Details
- Product Certifications BV CSA UL RINA GOST LROS (Lloyds register of shipping) CCC GL DNV
- Motor Power Kw 7.5 kW 220...230 V AC 50/60 Hz AC-3) 15 kW 380...400 V AC 50/60 Hz AC-3) 15 kW 415...440 V AC 50/60 Hz AC-3) 18.5 kW 500 V AC 50/60 Hz AC-3) 18.5 kW 660...690 V AC 50/60 Hz AC-3) 7.5 kW 400 V AC 50/60 Hz AC-4)
- [Icw] Rated Short-Time Withstand Current 260 A 104 °F (40 °C) - 10 s power circuit 430 A 104 °F (40 °C) - 1 s power circuit 60 A 104 °F (40 °C) - 10 min power circuit 138 A 104 °F (40 °C) - 1 min power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circ
- Motor Power HP (UL / CSA) 2 hp 115 V at AC 50/60 Hz for 1 phase 5 hp 230/240 V at AC 50/60 Hz for 1 phase 7.5 hp 200/208 V at AC 50/60 Hz for 3 phase 10 hp 230/240 V at AC 50/60 Hz for 3 phase 20 hp 460/480 V at AC 50/60 Hz for 3 phase 30 hp 575/600 V at A
- [Ui] Rated Insulation Voltage Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL
- Standards CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
- Control Circuit Voltage Limits 0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz 0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz 1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz
- Associated Fuse Rating 10 A gG signalling circuit IEC 60947-5-1 63 A gG <= 690 V type 1 power circuit 63 A gG <= 690 V type 2 power circuit
- Tightening Torque Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat Ø 6 mm M3.5 Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals Philips No 2 M3.5 Power circuit 22.13 lbf.in (2.5 N.m) lugs-ring terminals flat Ø 8 mm M4 Power circuit 2
- Irms Rated Making Capacity 140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 550 A 440 V power circuit IEC 60947
- Utilisation Category AC-3 AC-1 AC-4
- Power Dissipation Per Pole 2 W AC-3 5 W AC-1
- Electrical Durability 1.65 Mcycles 32 A AC-3 <= 440 V 1.4 Mcycles 50 A AC-1 <= 440 V
- Hold-In Power Consumption In VA 7.5 VA 60 Hz 0.3 68 °F (20 °C)) 7 VA 50 Hz 0.3 68 °F (20 °C))
- Operating Time 12...22 ms closing 4...19 ms opening
- Inrush Power In VA 70 VA 60 Hz 0.75 68 °F (20 °C)) 70 VA 50 Hz 0.75 68 °F (20 °C))
- [Ith] Conventional Free Air Thermal Current 10 A 140 °F (60 °C) signalling circuit 50 A 140 °F (60 °C) power circuit
- Mounting Support Rail Plate
- Contactor Application Motor control Resistive load
- Auxiliary Contacts Type Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
- [Ue] Rated Operational Voltage Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
- [Ie] Rated Operational Current 32 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit 50 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
- Connections - Terminals Control circuit lugs-ring terminals 0.31 in (8 mm)) Power circuit lugs-ring terminals 0.39 in (10 mm))
- Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Non-Overlap Time 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
- Minimum Switching Voltage 17 V signalling circuit
- Maximum Operating Rate 3600 cyc/h 140 °F (60 °C)
- Insulation Resistance > 10 MOhm signalling circuit
- Minimum Switching Current 5 mA signalling circuit
- Heat Dissipation 2…3 W 50/60 Hz
- Signalling Circuit Frequency 25...400 Hz
- Coil Technology Without built-in suppressor module
- Mechanical Durability 15 Mcycles
- Front Cover With
- Average Impedance 2 mOhm - Ith 50 A 50 Hz power circuit
- Rated Breaking Capacity 550 A 440 V power circuit IEC 60947
- [Uimp] Rated Impulse Withstand Voltage 6 kV IEC 60947
- Overvoltage Category III
- [Uc] Control Circuit Voltage 24 V AC 50/60 Hz
- Auxiliary Contact Composition 1 NO + 1 NC
- Control Circuit Type AC 50/60 Hz
- Power Pole Contact Composition 3 NO
- Product Name TeSys D
- Range TeSys
- Product Or Component Type Contactor
- Device Short Name LC1D
- Poles Description 3P
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Related documents LC1D326B7 Specs
This item can ship within 24h!
Manufacturer warranty
$172.00
Stock:
1
Select Qty:
$172.00
$172.00 each
Worldwide Shipping and Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Relevant products
What can I help you find today?