HDL36100U44X Schneider Electric Industrial Automation Components


Part#:HDL36100U44X
Manufacturer:Schneider Electric
Category:Industrial Automation Components
Product Lifecycle:Active
Product description
Square D by Schneider Electric HDL36100U44X is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT HDL sub-range, designed with a PowerPact H-Frame 150 Micrologic 6.2A (LSIG) 3P 100A 600Vac/250Vdc 14kA. It features lugs on both load and line sides for connection, and it is a 3-pole (3P) device. This MCCB offers protection functions including Long-time (L), Short-time with fixed time delay (S), Instantaneous (I), Ground fault (G), and Zone Selective Interlocking (ZSI). It has a rated current of 100A, a rated insulation voltage (Ui) of 750 V, and a rated voltage (AC) of 600Vac 600Y/347Vac. The unit is designed for individual unit mount on plate, with a net height of 163 mm, a net width of 104 mm, and a net depth of 86 mm. It offers a degree of protection of IP40 and operates with a toggle (manual) mode. Protection settings are adjustable, with L protection against overload adjustable from 0.35 to 1 x In (35A to 100A), S protection against short-circuit with time delay adjustable from 1.5 to 10 x Ir (150A to 1000A), I instantaneous protection against short-circuit adjustable from 1.5 to 15 x In (150A to 1500A), and G protection against earth fault adjustable at 0.2 to 1 x In (0.1 to 0.4s time delay). The rated operating voltage (Ue) is 690 V, with a rated impulse voltage (Uimp) of 8 kV. The trip current rating is 100 AT, with a frame current rating of 150 AF. It has a short circuit breaking rating of 25kA (240Vac; UL489), 18kA (480Vac; UL489), 18kA (480Y/277Vac; UL489), 14kA (600Vac; UL489), 14kA (600Y/347Vac; UL489), and 20kA (250Vdc; UL489). The trip unit type is an electronic Micrologic Ammeter 6.2A (LSIG) with LSIG protection and an LCD display. Its measurement function includes current measurements for phases and neutral, RMS instantaneous current, current unbalance between phases, highest RMS current of the 3 phases, ground fault current, and demand/peak current values on all 3 phases plus neutral with an adjustable calculation window of 5-60min. The utilisation category is A.
Product Details
- Tightening Torque 44.25 lbf.in (5 N.m) 0.00…0.15 in² (2.5…95 mm²) (AWG 14...AWG 3/0)
- Line Rated Current 100 A
- Number Of Poles 3P
- Range Of Product PowerPact H
- Depth 4.36 in (110.74 mm)
- Height 6.4 in (162.56 mm)
- Mounting Mode Unit mount
- Continuous Current Rating 80 %
- Product Or Component Type Circuit breaker
- Width 4.12 in (104.65 mm)
- Breaking Capacity Code D
- Electrical Connection Lugs load Lugs line
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
The price of HDL36100U44X on Powermatic Associates is $2,991.00. Order now.
HDL36100U44X Related Documents
Similar products from: Schneider Electric Industrial Automation Components
Manufacturer warranty
HDL36100U44X Schneider Electric
$2,991.00
Your price can be lower.
Log in or Create account to check your discount
Select Qty:
$2,991.00
$2,991.00 each
Average response time: 11 minutes
Worldwide Shipping and Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Compare HDL36100U44X with other Industrial Automation Components products
Tightening Torque
Line Rated Current
Number Of Poles
Range Of Product
Depth
Height
Mounting Mode
Continuous Current Rating
Product Or Component Type
Width
Selected product

HDL36100U44X
Schneider Electric
Square D by Schneider Electric HDL36100U44X is a Moulded Case Circuit Breaker (MCCB) within the Powe...
Tightening Torque44.25 lbf.in (5 N.m) 0.00…0....
Line Rated Current100 A
Number Of Poles3P
Range Of ProductPowerPact H
Depth4.36 in (110.74 mm)
Height6.4 in (162.56 mm)
Mounting ModeUnit mount
Continuous Current Rating80 %
Product Or Component TypeCircuit breaker
Width4.12 in (104.65 mm)
About the manufacturer
Powermatic Associates is an authorized Schneider Electric distributor, proudly offering a diverse portfolio of innovative solutions tailored to meet the dynamic needs of today's industrial landscape. Schneider Electric stands as a global leader in energy management and automation, providing cutting-edge products and services that drive efficiency and sustainability across a variety of sectors. The...
Recently viewed products
Relevant products
FAQ
What is the price of HDL36100U44X?
Purchase the HDL36100U44X from Powermatic Associates at the price of $2,991.00. Order today.
Out if stock but available for backorder.
Square D by Schneider Electric HDL36100U44X is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT HDL sub-range, designed with a PowerPact H-Frame 150 Micrologic 6.2A (LSIG) 3P 100A 600Vac/250Vdc 14kA. It features lugs on both load and line sides for connection, and it is a 3-pole (3P) device. This MCCB offers protection functions including Long-time (L), Short-time with fixed time delay (S), Instantaneous (I), Ground fault (G), and Zone Selective Interlocking (ZSI). It has a rated current of 100A, a rated insulation voltage (Ui) of 750 V, and a rated voltage (AC) of 600Vac 600Y/347Vac. The unit is designed for individual unit mount on plate, with a net height of 163 mm, a net width of 104 mm, and a net depth of 86 mm. It offers a degree of protection of IP40 and operates with a toggle (manual) mode. Protection settings are adjustable, with L protection against overload adjustable from 0.35 to 1 x In (35A to 100A), S protection against short-circuit with time delay adjustable from 1.5 to 10 x Ir (150A to 1000A), I instantaneous protection against short-circuit adjustable from 1.5 to 15 x In (150A to 1500A), and G protection against earth fault adjustable at 0.2 to 1 x In (0.1 to 0.4s time delay). The rated operating voltage (Ue) is 690 V, with a rated impulse voltage (Uimp) of 8 kV. The trip current rating is 100 AT, with a frame current rating of 150 AF. It has a short circuit breaking rating of 25kA (240Vac; UL489), 18kA (480Vac; UL489), 18kA (480Y/277Vac; UL489), 14kA (600Vac; UL489), 14kA (600Y/347Vac; UL489), and 20kA (250Vdc; UL489). The trip unit type is an electronic Micrologic Ammeter 6.2A (LSIG) with LSIG protection and an LCD display. Its measurement function includes current measurements for phases and neutral, RMS instantaneous current, current unbalance between phases, highest RMS current of the 3 phases, ground fault current, and demand/peak current values on all 3 phases plus neutral with an adjustable calculation window of 5-60min. The utilisation category is A.
Similar products from: Industrial Automation Components