FPT300.242-002-101 Puls Power Supplies

FPT300.242-002-101 on Powermatic Associates
Puls

Part#:FPT300.242-002-101

Manufacturer:Puls

Category:Power Supplies

Product Lifecycle:Active

Product description

PULS FPT300.242-002-101 is a power supply unit from the FPT300 Basic 3AC series, designed to function as a field AC/DC power supply unit (PSU) / converter with an IO-Link interface output on X3 pins 1&2. It features a robust aluminium housing with dimensions of W182mm x H183mm x D59mm. The unit offers a variety of connection types including a HanQ4/2 connector for input (X1), a 5-pin M12 connector for the IO-Link interface (X2), and a HanQ4/0 connector for output (X3; pin 3 = "+", pin 4 = "-"). It operates on an IO-Link communication protocol and is equipped with protection functions such as output overvoltage protection (31.8Vdc typ. / 32.5Vdc max.), overload/short-circuit current protection, and over-temperature protection with automatic restart. The device is not suitable for series or parallel operation and has a back-feeding load resistance up to 35V 4J / 32V 2.8J. It has a rated current of 12.5A at 24Vdc and can accept a supply voltage (AC) ranging from 323Vac to 552Vac across various nominal voltages, with specific performance during the loss of 1-phase. Mounting can be achieved via hanging and fixing through integrated keyholes or by screw mounting. The unit operates within an ambient air temperature range of -25...+55 °C (with linear derating) to +55...+70 °C and offers a degree of protection of IP65/IP67. Designed for a 3-phase (3AC) network, it has a current consumption of 0.5A/0.42A under full output with symmetrical phases and a peak inrush of 2A. The efficiency rates are 0.952 (3x400Vac input) and 0.95 (3x480Vac input), with a rated power of 300W at operational temperatures up to +55°C, derating linearly to 150W at +70°C, and offering short-term power capabilities. The output voltage is fixed at 24Vdc with a 500mV turn-ON overshoot, and the unit provides a hold time of 25ms at 400/480Vac input. Electrical durability varies with conditions, offering up to 882000 hours of operation under certain conditions. Power dissipation/losses are noted at 15.1 W for 3x400Vac input and 15.8 W for 3x480Vac input, with an output stage capacitance of 18000 µF and a ripple of 100mVpp.

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

FPT300.242-002-101 Puls

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

About the manufacturer

Puls

Powermatic Associates is an authorized Puls distributor, proudly offering their innovative and reliable industrial power supply solutions. Puls is a renowned manufacturer specializing in high-quality DIN rail power supplies, engineered to deliver optimal performance and efficiency across various demanding applications. Their product portfolio includes single-phase and three-phase power supplies, D...

Recently viewed products

Relevant products

FPT300.242-008-102 on Powermatic Associates

FPT300.242-008-102

Verified stock: 0

PULS FPT300.242-008-102 is a power supply unit from the FPT300 Basic 3AC series designed with an IO-Link interface. This unit, encased in an aluminium housing, measures W182mm x H272mm x D70mm and utilizes a HanQ4/2 connector for input, a 5-pin M12 connector for the IO-Link interface, and a QuickON connector for output. It supports a communication protocol of IO-Link and offers protection functions including output overvoltage protection with typical 31.8Vdc and maximum 32.5Vdc, overload and short-circuit protection with a maximum continuous current of 15A, and over-temperature protection with automatic restart. The device is not suitable for series or parallel operation and can handle back-feeding loads up to 35V 4J / 32V 2.8J. It operates with a rated current of 12.5A at 24Vdc and can be supplied with an AC voltage ranging from 323Vac to 552Vac across various nominal voltages, maintaining operation under single-phase loss conditions within specified limits. Mounting can be achieved via hanging and fixing through integrated keyholes or screw mounting, and it is designed to operate within an ambient air temperature range of -25 to +55 °C, with linear derating up to +70 °C. The unit boasts an IP54 degree of protection, is designed for a 3-phase network, and exhibits an efficiency of 0.952 to 0.95 depending on the input voltage. The rated power is 300W at operational temperatures up to +55°C, with short-term capabilities of 450W for 60s and 600W for 1s within the same temperature range. It features a 1s start-up delay, a rise time of 10ms to 12ms depending on load capacitance, and a hold time of 25ms at 400/480Vac input. Electrical durability is rated up to 882000 hours under certain conditions, with power dissipation/losses of 15.1W to 15.8W and an output stage capacitance of 18000 µF, alongside a ripple of 100mVpp.

Puls

FPT300.246-042-101 on Powermatic Associates

FPT300.246-042-101

Verified stock: 0

PULS FPT300.246-042-101 is a power supply unit from the FPT300 eFused NEC Class 2 3AC series, designed to convert field AC to DC power with 4 individually protected switchable NEC Class 2 outputs and an IO-Link interface. It features a robust aluminium housing with dimensions of W182mm x H272mm x D70mm. The unit connects via a HanQ5/0 female connector for input, a 5-pin M12 connector for the IO-Link interface, and 4 x M12 A-coded connectors for output. It supports the IO-Link communication protocol and includes protection functions such as output overvoltage protection, overload/short-circuit protection with an individual inverse time curve for each output, and over-temperature protection with automatic restart. The device operates on a supply voltage of 323Vac-552Vac across various nominal voltages and maintains functionality under a single-phase loss if loaded below limits. It cannot operate in series or parallel and is designed for hanging or screw mounting with an IP54 degree of protection. The ambient air temperature for operation ranges from -25 to +70°C with linear derating above +55°C. It has a rated power of 300W at temperatures up to +55°C, with short-term capabilities up to 600W, and features a 24Vdc-28Vdc adjustable output voltage. The unit's efficiency is noted at 0.952 for 3x400Vac input and 0.95 for 3x480Vac input, with a current consumption of 0.5A at full output for 3x400Vac and 0.42A for 3x480Vac, peaking at 2A inrush. Electrical durability is extensive, with hours ranging based on conditions and input, and power dissipation/losses are specified for full output load conditions.

Puls

FAQ

Out if stock but available for backorder.

PULS FPT300.242-002-101 is a power supply unit from the FPT300 Basic 3AC series, designed to function as a field AC/DC power supply unit (PSU) / converter with an IO-Link interface output on X3 pins 1&2. It features a robust aluminium housing with dimensions of W182mm x H183mm x D59mm. The unit offers a variety of connection types including a HanQ4/2 connector for input (X1), a 5-pin M12 connector for the IO-Link interface (X2), and a HanQ4/0 connector for output (X3; pin 3 = "+", pin 4 = "-"). It operates on an IO-Link communication protocol and is equipped with protection functions such as output overvoltage protection (31.8Vdc typ. / 32.5Vdc max.), overload/short-circuit current protection, and over-temperature protection with automatic restart. The device is not suitable for series or parallel operation and has a back-feeding load resistance up to 35V 4J / 32V 2.8J. It has a rated current of 12.5A at 24Vdc and can accept a supply voltage (AC) ranging from 323Vac to 552Vac across various nominal voltages, with specific performance during the loss of 1-phase. Mounting can be achieved via hanging and fixing through integrated keyholes or by screw mounting. The unit operates within an ambient air temperature range of -25...+55 °C (with linear derating) to +55...+70 °C and offers a degree of protection of IP65/IP67. Designed for a 3-phase (3AC) network, it has a current consumption of 0.5A/0.42A under full output with symmetrical phases and a peak inrush of 2A. The efficiency rates are 0.952 (3x400Vac input) and 0.95 (3x480Vac input), with a rated power of 300W at operational temperatures up to +55°C, derating linearly to 150W at +70°C, and offering short-term power capabilities. The output voltage is fixed at 24Vdc with a 500mV turn-ON overshoot, and the unit provides a hold time of 25ms at 400/480Vac input. Electrical durability varies with conditions, offering up to 882000 hours of operation under certain conditions. Power dissipation/losses are noted at 15.1 W for 3x400Vac input and 15.8 W for 3x480Vac input, with an output stage capacitance of 18000 µF and a ripple of 100mVpp.

What can I help you find today?

Recommended parts