About the manufacturer: Turck is one of the manufacturers that offers Flow Sensors that you can order at Powermatic Associates site. Turck is a leading provider of sensor, fieldbus, and connectivity technologies, along with interface technology, human-machine interfaces (HMI), and RFID systems. We offer innovative solutions for factory and process automation requirements, guaranteeing top-notch performance.

Check out the FCI-1/4TCD04A4P-AP8X-H1141 Turck price in the box on the right side or send a quick quote.

Product Details

  • Weight
    369 g
  • Medium temperature
    0…+60 °C
  • Ambient temperature
    0…+60 °C
  • Housing material
    Plastic, PBT
  • Protection class
    IP67
  • Electrical connection
    Connector, M12 × 1
  • Sensor material
    Stainless steel
  • Operating principle
    Calorimetric
  • Output function
    NO contact, PNP
  • Medium
    liquids
  • Function
    Flow monitoring
  • Design
    Inline
  • Operating voltage
    19.2…28.8 VDC
  • Process connection
    ¼” tube connection

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


FCI-1/4TCD04A4P-AP8X-H1141 Description

Turck FCI-1/4TCD04A4P-AP8X-H1141 is a sensor designed for flow monitoring with a PBT (Polybutylene Terephthalate) housing, Stainless steel 316Ti tubing, and Stainless steel 303 connector. It operates within an ambient air temperature range of 0°C to +60°C and consumes 50mA of current. This sensor is protected to IP67 standards and has a response time of 5-15 seconds during startup and 500ms to 3 seconds in normal operation. It features 1 x digital output (20-30Vdc; PNP) and is designed with a rectangular body. The control circuit is rated for 200mA / 0.2 A, and it includes protection functions against short-circuit (pulsed) and reverse polarity. The flow rate capability is 1 to 200mL/min (water), and it is part of the FCI series, functioning as an instrumentation inline flow monitor sensor/switch. The connection type is a pre-equipped 4-pin M12 Eurofast QD male connector and a 1/4" NPT threaded process port with a 4mm inline diameter. It can withstand pressure up to 10bar (145psi) and requires a supply voltage of 21.6-26.4Vdc (24Vdc nom.). The medium temperature range is 0 to +60°C.



Related documents FCI-1/4TCD04A4P-AP8X-H1141 Specs

Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts

UBC10.241

UBC10.241

PULS UBC10.241 is an Uninterruptible Power Supply (UPS) control module within the U-series, featuring a built-in battery with a 50% power reserve and a green status LED. This module is housed in aluminium and utilizes spring-clamp connections for installation. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can reach up to 15A in buffer mode for less than 5 seconds at full output voltage. It supports DIN rail mounting and can operate in ambient air temperatures ranging from 0 to +40°C. The current consumption is 1.1A at a 24Vdc input, and it is designed for DC networks. Visual position indicators include Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. It is advised not to use the DC-UPS in parallel to increase output power, but paralleling two units for 1+1 redundancy is possible for higher system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. The efficiency is rated at 0.978 with a 24Vdc input, and the rated power is 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W with a 24Vdc input at 0A output current and 5.5W at 10A output current. Ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. The electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output.

Puls

1