GV2ME026 Schneider Electric Industrial Automation Components


Part#:GV2ME026
Manufacturer:Schneider Electric
Category:Industrial Automation Components
Product Lifecycle:Active
Get a quick Quote!
Schneider Electric GV2ME026 is a Motor Protection Circuit Breaker (MPCB) within the GV2ME sub-range, designed for thermal-magnetic motor protection and manual motor starting. It features 3 poles and provides protection functions against short-circuit and thermal overload with a rated current of 0.16 - 0.25 A. The device is equipped for DIN rail mounting and has a net width of 45 mm. Operation is facilitated through a push-button mechanism. Protection settings for short-circuit pickup current are fixed at 2.4A. The GV2ME026 has a rated insulation voltage (Ui) of 690 V, a rated impulse voltage (Uimp) of 6 kV, and supports a rated active power (kW) of 0.06 kW at 400/415Vac. Its trip current rating is 0.25 AT with a frame current rating of 32 AF. Mechanical durability is rated at 100,000 operations at no load, and electrical durability at 100,000 operations with load (440Vac; AC-3; In/2). Terminal connections are made via lug-ring terminals. The rated voltage (AC) phase-to-phase is 690 V, with all three poles protected. The trip unit type is thermal-magnetic, supporting a minimum current of 0.16 A and a maximum current of 0.25 A, classified under utilisation category A AC-3.
About the manufacturer: Schneider Electric is one of the manufacturers that offers Industrial Automation Components that you can order at Powermatic Associates site. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.
Check out the GV2ME026 Schneider Electric price in the box on the right side or send a quick quote.
Product Details
- Breaking Capacity 100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 100 kA Icu 690 V AC 50/60 Hz IEC 60947-2
- [Ics] Rated Service Short-Circuit Breaking Capacity 100 % 690 V AC 50/60 Hz IEC 60947-2 100 % 500 V AC 50/60 Hz IEC 60947-2 100 % 230/240 V AC 50/60 Hz IEC 60947-2 100 % 440 V AC 50/60 Hz IEC 60947-2 100 % 400/415 V AC 50/60 Hz IEC 60947-2
- Fixing Mode 35 mm symmetrical DIN rail clipped Panel screwed with adaptor plate)
- Tightening Torque 15.05 lbf.in (1.7 N.m) lugs-ring terminals M4 15.05 lbf.in (1.7 N.m) bars M4
- Utilisation Category AC-3 IEC 60947-4-1 Category A conforming to IEC 60947-2
- Depth 3.09 in (78.5 mm)
- [Uimp] Rated Impulse Withstand Voltage 6 kV IEC 60947-2
- Net Weight 0.57 lb(US) (0.26 kg)
- Width 1.77 in (45 mm)
- Height 3.50 in (89 mm)
- Phase Failure Sensitivity Yes IEC 60947-4-1
- Suitability For Isolation Yes conforming to IEC 60947-1
- Maximum Operating Rate 25 cyc/h
- Electrical Durability 100000 cycles AC-3 440 V
- Rated Duty Continuous IEC 60947-4-1
- Connection Pitch 0.53 in (13.5 mm) without spreader
- Mechanical Durability 100000 cycles
- Power Dissipation Per Pole 2.5 W
- [Ith] Conventional Free Air Thermal Current 0.25 A IEC 60947-4-1
- [Ue] Rated Operational Voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
- [Ui] Rated Insulation Voltage 690 V AC 50/60 Hz IEC 60947-2
- Thermal Protection Adjustment Range 0.16…0.25 A
- Magnetic Tripping Current 2.4 A
- Line Rated Current 0.25 A
- Control Type Push-button
- Operating Position Any position
- Network Frequency 50/60 Hz IEC 60947-4-1
- Motor Power Kw 0.06 kW 400/415 V AC 50/60 Hz
- Poles Description 3P
- Product Name TeSys GV2
- Trip Unit Technology Thermal-magnetic
- Device Short Name GV2ME
- Network Type AC
- Product Or Component Type Circuit breaker
- Range TeSys
- Device Application Motor
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Related documents GV2ME026 Specs
Manufacturer warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Worldwide Shipping and Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
Relevant products
What can I help you find today?