servo drive CMMT-AS-C4-3A-EP-S1 Mounting type: Mounting plate, bolted, Assembly position: (* Free convection, * Vertical), Product weight: 1400 g, Display: LED green/yellow/red, Control elements: Optional: control unit CDSB

About the manufacturer: Festo is one of the manufacturers that offers Servo Amplifiers that you can order at Powermatic Associates site. Festo Corp. has been a top supplier of automation and intelligent automation solutions for more than four decades in the United States and eight decades globally. The company is committed to transforming the manufacturing sector and enhancing business efficiency.

Check out the 5340825 Festo price in the box on the right side or send a quick quote.

Product Details

  • Mounting position
    Free convection Vertical
  • Encoder interface 2, function
    Incremental encoder SIN/COS encoder
  • Number of diagnostic outputs
    2
  • Number of high-speed logic inputs
    2
  • Max. installation height
    2000 m
  • Controller operating mode
    Cascade control Autotuning
  • Control elements
    Optional: CDSB operating unit
  • Diagnostic coverage
    97 %
  • Impedance of setpoint input
    70 kOhm
  • Input voltage range AC
    100 V ... 230 V
  • Max. DC link voltage
    395 V
  • SFF safe failure fraction
    99 %
  • Peak current, load supply
    16.8 A
  • Max. current consumption for logic supply without clamping brake
    0.5 A
  • Permissible voltage fluctuations
    -20 % / +15 %
  • CE marking (see declaration of conformity)
    As per EU EMC directive As per EU RoHS directive
  • Certification
    RCM compliance mark c UL us - Listed (OL)
  • Communication profile
    DriveProfile
  • Work range of logic input
    -3 V ... 30 V
  • Switching logic at outputs
    PNP (positive switching)
  • Fieldbus interface, function
    Bus connection, incoming/forwarding EtherNet/IP slave
  • Information on max. installation height
    1% power reduction/100 m above 1000 m.
  • Protection class
    I
  • Overvoltage category
    III
  • Max. current of the floating switching outputs
    50 mA
  • Max. output current of holding brake
    1 A
  • Braking resistor nominal power (IEC)
    23 W
  • Max. current consumption for logic supply with parking brake
    1.5 A
  • Active PFC
    no
  • Mode of operation
    Field-oriented regulation 1x SYNC interface for encoder emulation or encoder input
  • Safety function
    Safe brake control (SBC) Safe stop 1 (SS1)
  • Output voltage range AC
    3x (0 – input) V
  • Max. current of digital logic outputs
    20 mA
  • Nominal voltage, logic supply DC
    24 V
  • Nominal current per phase, effective
    4 A
  • Peak current per phase, effective
    12 A
  • Max. current consumption for logic supply with clamping brake and I/O
    2.3 A
  • Ambient temperature
    0 °C ... 50 °C
  • Process interfacing
    Adjustable-Speed Drives Drives with positioning function
  • Characteristics of setpoint inputs
    Differential inputs Configurable for current/force
  • Note on materials
    Contains paint-wetting impairment substances RoHS-compliant
  • KC characters
    KC EMC
  • Ethernet interface, function
    Parameterization and commissioning
  • Mains types
    TT IT
  • Number of floating switching outputs
    1
  • Number of high-speed switching outputs
    2
  • System voltage to EN 61800-5-1
    300 V
  • Max. voltage drop from logic supply to brake output
    0.8 V
  • Time resolution of high-speed switching outputs
    1 µs
  • Conforms to standard
    EN 61800-3 EN ISO 13849-1
  • Display
    LED green/yellow/red
  • Characteristics of digital logic outputs
    Freely configurable in some cases Diagnostic outputs in some cases
  • Hardware fault tolerance
    1
  • Controller nominal power
    700 VA
  • Mains frequency
    48 Hz ... 62 Hz
  • Contamination level
    2
  • Certificate issuing authority
    German Technical Control Board (TÜV) Rheinland 01/205/5640.00/18 UL E331130
  • Relative air humidity
    5 - 90 % Non-condensing
  • UL-ambient temperature
    0 °C ... 40 °C
  • Number of digital logic outputs 24 V DC
    6
  • Operating range of analog inputs
    ± 10 V
  • Characteristics of logic input
    Freely configurable in some cases Not galvanically isolated
  • Type of mounting
    Mounting plate, screwed on
  • Type code
    CMMT-AS
  • Encoder interface, function
    EnDat® 2.1 encoder SIN/COS encoder
  • Synchronization interface, function
    Encoder emulation A/B/Z Encoder input A/B/Z
  • Max. continuous output of the external braking resistor (IEC)
    350 W
  • Number of safe 2-pin inputs
    2
  • Based on norm
    EN 50581 EN 62061
  • Line filter
    Integrated
  • Safety integrity level (SIL)
    Safe brake control (SBC)/SIL 3/SILCL 3 Safe torque off (STO)/SIL 3/SILCL 3
  • Braking resistor, integrated
    100 Ohm
  • Max. length of motor cable without ext. mains filter
    25 m
  • Max. peak current duration
    2 s
  • Nominal voltage, load supply DC
    320 V
  • Peak power
    2000 VA
  • Nominal operating voltage phases
    1-phase
  • Load supply permissible range
    -20 %/+15 %
  • Degree of protection
    IP20
  • Number of analog setpoint inputs
    1
  • Number of digital logic inputs
    12
  • Work range of setpoint input
    ± 10 V
  • Encoder interface input, characteristics
    1 MHz maximum output frequency max. 16384 ppr
  • Fieldbus interface, transmission rate
    100 Mbit/s
  • Ethernet interface, protocol
    TCP/IP
  • Fieldbus interface, connection technology
    RJ45
  • Fieldbus interface, protocol
    EtherNet/IP
  • Fieldbus interface, connection type
    2x socket
  • Number of inputs for motor temperature sensor
    1
  • Pulse energy for braking resistor
    230 Ws
  • Max. short circuit protection of mains
    100 kA
  • Time resolution of high-speed logic inputs
    1 µs
  • Performance Level (PL)
    Safe brake control (SBC)/category 3, performance level e Safe torque off (STO)/category 4, performance level e
  • Output frequency
    0 Hz ... 599 Hz
  • Braking resistor, external
    67 Ohm ... 100 Ohm
  • Pulse power of braking resistor
    1.6 kVA
  • Nominal operating voltage AC
    230 V
  • Nominal current load supply
    5.6 A
  • Surge resistance
    6 kV
  • Permissible range of logic voltage
    ± 20 %
  • Storage temperature
    -25 °C ... 55 °C
  • Note on ambient temperature
    Above an ambient temperature of 40 °C, the power must be reduced by 3%/°C.
  • Product weight
    1400 g
  • Logic input specification
    Based on IEC 61131-2, type 3
  • Encoder interface output, characteristics
    1 MHz maximum output frequency max. 16384 ppr
  • Input switching logic
    PNP (positive switching)
  • Fieldbus coupling
    EtherNet/IP

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.



Related documents 5340825 Specs

Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts

UBC10.241 on Powermatic Associates

UBC10.241

PULS UBC10.241 is an Uninterruptible Power Supply (UPS) control module within the U-series, featuring a built-in battery with a 50% power reserve and a green status LED. This module is housed in aluminium and utilizes spring-clamp connections for installation. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can reach up to 15A in buffer mode for less than 5 seconds at full output voltage. It supports DIN rail mounting and can operate in ambient air temperatures ranging from 0 to +40°C. The current consumption is 1.1A at a 24Vdc input, and it is designed for DC networks. Visual position indicators include Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. It is advised not to use the DC-UPS in parallel to increase output power, but paralleling two units for 1+1 redundancy is possible for higher system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. The efficiency is rated at 0.978 with a 24Vdc input, and the rated power is 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W with a 24Vdc input at 0A output current and 5.5W at 10A output current. Ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. The electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output.

Puls

1