Schneider Electric M9F42220 is a Miniature Circuit Breaker (MCB) within the C60BP sub-range, designed for two-pole operation with a rated current of 20A. It features a rated insulation voltage (Ui) of 500V, a DC rated voltage of 60Vdc, and an AC rated voltage of 240V phase-to-neutral and 415V phase-to-phase. The M9F42220 has a rated impulse voltage (Uimp) of 6kV and offers a short circuit breaking rating of 14kA AIR at both 120Vac and 240Vac, and 10kA AIR at 480Y/277Vac and 60Vdc. Both poles are protected, and it operates with a C tripping curve.
14 in stock
24 hours
Schneider Electric LC1DT406BD is a magnetic contactor from the Deca sub-range, designed with ring-lugs connections and equipped with 4 poles (4NO). It has a rated current of 40A (AC-1) and is suitable for DIN rail mounting. The dimensions include a net width of 45 mm and it offers a degree of protection rated at IP20. This contactor operates with a control voltage (DC) range of 18-30Vdc, nominally at 24Vdc, and includes 1 normally open (NO) and 1 normally closed (NC) auxiliary contacts, both of the instantaneous type. It is designed to withstand a rated impulse voltage (Uimp) of 6 kV and has a mechanical durability of 15,000,000 operations at no load. The rated voltage (AC) for phase-to-phase connections is up to 690 V.
6 in stock
24 hours
Schneider Electric RSB1A120BD is a relay from the RSB sub-range designed for interfacing plug-in applications. It features contacts made from an Ag/Ni - Silver - Nickel alloy and operates with a Single Pole Double Throw (SPDT) contact type. The control voltage for this device is specified at 24 Vdc, and it can handle a rated current of 12 A for both 250Vac (AC-1) and 28Vac (DC-1). It is designed for plug-in mounting and can operate within an ambient air temperature range of -40 to +70��C. The RSB1A120BD offers an IP40 degree of protection and has a rated voltage for AC circuits up to 600 V. Its protection functions include Long-time protection (L), Short-time protection with fixed time delay (S), Instantaneous protection (I), and Ground fault protection (G). The trip current rating and frame current rating are both 3000, with a short circuit breaking rating that varies depending on the voltage: 125kA at 240Vac, 100kA at 480Y/277Vac and 480Vac, and 50kA at 600Y/347Vac and 600Vac. This relay is designed to protect 3 poles and utilizes a Micrologic 6.0A (LSIG) Electronic trip unit type.
15 in stock
24 hours
Square D by Schneider Electric BDL36125 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BDL sub-range, featuring a PowerPact B-Frame 125 TMD 3P 125A design for 600Y/347Vac with a 14kA breaking capacity and 80% rated Everlink (Creep compensating) lugs on both line and load sides. It has a rated impulse voltage (Uimp) of 8 kV and offers a degree of protection of IP40. The rated current is 125A, with a rated voltage (AC) of 600Vac 600Y/347Vac. It boasts a mechanical durability of 20,000 operations at no load and can be mounted on a DIN rail or as an individual unit on a plate. This 3-pole (3P) circuit breaker has dimensions of 137 mm in height, 80 mm in depth, and 81 mm in width. It falls under utilisation category A and features over-current protection fixed at 125A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 525 V. It provides thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 125 AT and an electrical durability of 10,000 operations with load at 440Vac. The frame current rating is 125 AF, operated by a toggle (manual) mechanism. Its short circuit breaking rating varies by voltage, with 25kA at 240Vac, 18kA at 480Vac and 480Y/277Vac, 14kA at 600Y/347Vac, and 10kA at 250Vdc, all according to UL489 standards. The trip unit is a fixed thermal-magnetic type without a display.
1 in stock
24 hours
Square D by Schneider Electric LGL36400U31X is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT LGL sub-range, featuring a PowerPact L-Frame 600 Micrologic 3.3 (LI) design. It is a 3-pole (3P) device with a rated current of 400A and a rated insulation voltage (Ui) of 750 V. The rated voltage (AC) is 600Vac 600Y/347Vac, and it supports a mounting mode of individual unit mount on plate. The dimensions include a net height of 382 mm, a net width of 153 mm, and a net depth of 171 mm. It offers a degree of protection of IP40 and operates manually via a toggle. The protection functions include L (Long-time protection) and I (Instantaneous protection), with protection settings adjustable for overload (0.3...1 x In, 125A...400A) and instantaneous protection against short-circuit (1.5...12 x In, 600A...4800A). The rated operating voltage (Ue) is 690 V, with a rated impulse voltage (Uimp) of 8 kV. The trip current rating is 400 AT, and the frame current rating is 600 AF. The short circuit breaking rating varies with voltage, up to 65kA at 240Vac under UL489 standards. Connection type is lugs on both load and line sides, and the trip unit type is an electronic Micrologic Standard 3.3 (LI) with no display, categorized under utilisation category A.
4 in stock
24 hours
Square D by Schneider Electric PK27GTA is a mounting accessory designed as a retaining kit.
1 in stock
24 hours
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
M9F42220 Schneider Electric M9F42220 is a Miniature Circuit Breaker (MCB) within the C60BP sub-range, designed for two-pole operation with a rated current of 20A. It features a rated insulation voltage (Ui) of 500V, a DC rated voltage of 60Vdc, and an AC rated voltage of 240V phase-to-neutral and 415V phase-to-phase. The M9F42220 has a rated impulse voltage (Uimp) of 6kV and offers a short circuit breaking rating of 14kA AIR at both 120Vac and 240Vac, and 10kA AIR at 480Y/277Vac and 60Vdc. Both poles are protected, and it operates with a C tripping curve. | Schneider Electric | $246.00 | 14 in stock | 24 hours | |
LC1DT406BD Schneider Electric LC1DT406BD is a magnetic contactor from the Deca sub-range, designed with ring-lugs connections and equipped with 4 poles (4NO). It has a rated current of 40A (AC-1) and is suitable for DIN rail mounting. The dimensions include a net width of 45 mm and it offers a degree of protection rated at IP20. This contactor operates with a control voltage (DC) range of 18-30Vdc, nominally at 24Vdc, and includes 1 normally open (NO) and 1 normally closed (NC) auxiliary contacts, both of the instantaneous type. It is designed to withstand a rated impulse voltage (Uimp) of 6 kV and has a mechanical durability of 15,000,000 operations at no load. The rated voltage (AC) for phase-to-phase connections is up to 690 V. | Schneider Electric | $245.70 | 6 in stock | 24 hours | |
DFCC1 Schneider Electric - DFCC1 | Schneider Electric | $18.00 | 11 in stock | 24 hours | |
RSB1A120BD Schneider Electric RSB1A120BD is a relay from the RSB sub-range designed for interfacing plug-in applications. It features contacts made from an Ag/Ni - Silver - Nickel alloy and operates with a Single Pole Double Throw (SPDT) contact type. The control voltage for this device is specified at 24 Vdc, and it can handle a rated current of 12 A for both 250Vac (AC-1) and 28Vac (DC-1). It is designed for plug-in mounting and can operate within an ambient air temperature range of -40 to +70��C. The RSB1A120BD offers an IP40 degree of protection and has a rated voltage for AC circuits up to 600 V. Its protection functions include Long-time protection (L), Short-time protection with fixed time delay (S), Instantaneous protection (I), and Ground fault protection (G). The trip current rating and frame current rating are both 3000, with a short circuit breaking rating that varies depending on the voltage: 125kA at 240Vac, 100kA at 480Y/277Vac and 480Vac, and 50kA at 600Y/347Vac and 600Vac. This relay is designed to protect 3 poles and utilizes a Micrologic 6.0A (LSIG) Electronic trip unit type. | Schneider Electric | $4.27 | 15 in stock | 24 hours | |
BDL36125 Square D by Schneider Electric BDL36125 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BDL sub-range, featuring a PowerPact B-Frame 125 TMD 3P 125A design for 600Y/347Vac with a 14kA breaking capacity and 80% rated Everlink (Creep compensating) lugs on both line and load sides. It has a rated impulse voltage (Uimp) of 8 kV and offers a degree of protection of IP40. The rated current is 125A, with a rated voltage (AC) of 600Vac 600Y/347Vac. It boasts a mechanical durability of 20,000 operations at no load and can be mounted on a DIN rail or as an individual unit on a plate. This 3-pole (3P) circuit breaker has dimensions of 137 mm in height, 80 mm in depth, and 81 mm in width. It falls under utilisation category A and features over-current protection fixed at 125A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 525 V. It provides thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 125 AT and an electrical durability of 10,000 operations with load at 440Vac. The frame current rating is 125 AF, operated by a toggle (manual) mechanism. Its short circuit breaking rating varies by voltage, with 25kA at 240Vac, 18kA at 480Vac and 480Y/277Vac, 14kA at 600Y/347Vac, and 10kA at 250Vdc, all according to UL489 standards. The trip unit is a fixed thermal-magnetic type without a display. | Schneider Electric | $1,793.00 | 1 in stock | 24 hours | |
LGL36400U31X Square D by Schneider Electric LGL36400U31X is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT LGL sub-range, featuring a PowerPact L-Frame 600 Micrologic 3.3 (LI) design. It is a 3-pole (3P) device with a rated current of 400A and a rated insulation voltage (Ui) of 750 V. The rated voltage (AC) is 600Vac 600Y/347Vac, and it supports a mounting mode of individual unit mount on plate. The dimensions include a net height of 382 mm, a net width of 153 mm, and a net depth of 171 mm. It offers a degree of protection of IP40 and operates manually via a toggle. The protection functions include L (Long-time protection) and I (Instantaneous protection), with protection settings adjustable for overload (0.3...1 x In, 125A...400A) and instantaneous protection against short-circuit (1.5...12 x In, 600A...4800A). The rated operating voltage (Ue) is 690 V, with a rated impulse voltage (Uimp) of 8 kV. The trip current rating is 400 AT, and the frame current rating is 600 AF. The short circuit breaking rating varies with voltage, up to 65kA at 240Vac under UL489 standards. Connection type is lugs on both load and line sides, and the trip unit type is an electronic Micrologic Standard 3.3 (LI) with no display, categorized under utilisation category A. | Schneider Electric | $5,502.97 | 4 in stock | 24 hours | |
PK27GTA Square D by Schneider Electric PK27GTA is a mounting accessory designed as a retaining kit. | Schneider Electric | $25.56 | 1 in stock | 24 hours | |
HJF36060 Schneider Electric - HJF36060 | Schneider Electric | $1,949.00 | 20 in stock | 24 hours | |
AM1DL201 Schneider Electric - AM1DL201 | Schneider Electric | $27.40 | 5 in stock | 24 hours | |
DZ5CE010 Schneider Electric - DZ5CE010 | Schneider Electric | $0.18 | 871 in stock | 24 hours |