Pilz PILZ-837300 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 24Vdc (DC-1; 120W) and 1.5A at 24Vdc (DC-13). Connection is facilitated through fixed screw terminal connections. As part of the S3UM sub-range, this unit measures 22.5mm in width, offers an IP40 degree of protection, and requires a supply voltage of 20.4-26.4Vdc (24Vdc nominal). It operates across a frequency measuring range of 40-400Hz and is housed in PPO material. Designed for a 3-phase (3AC) input network, it measures rated voltages of 208/400/480Vac and has a net width of 22.5 mm. Power consumption is rated at 1.5 W, with a net depth of 122 mm. Operating modes include fault latching/non-latching and normally energized/de-energized modes. Storage temperature tolerance ranges from -40 to +85°C. It features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc DC-1 resistive load; 0.5-10s time-delay selectable), 1 x analog input for L1-L3 voltage measurement, and protection functions against undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. Additionally, it includes 1 x automatic reset and 1 x switching commutation digital inputs.
Quick Quote
Pilz PILZ-837290 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15). Connection is facilitated through fixed screw terminal connections, and it requires a supply voltage of 20.4-26.4Vac (24Vac nominal) within the S3UM sub-range. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. The frequency measuring range is 40-400Hz, and it is housed in a PPO material. Designed for a 3-phase (3AC) input network, it has a rated voltage for measuring of 208/400/480Vac, a net width of 22.5 mm, and consumes 1.5 W of power. The net depth is 122 mm. Operating modes include fault latching or non-latching and normally energized or de-energized modes. It can be stored in temperatures ranging from -40 to +85°C. The unit features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load; 0.5-10s time-delay selectable for ON-delay energization), 1 x analog input for L1-L3 voltage measurement, and protection functions against undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. Digital inputs include 1 x automatic reset (Y1-Y2 linked) and 1 x switching commutation (Y2-Y3).
Quick Quote
Pilz PILZ-837285 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 24Vdc (DC-1; 120W) and 1.5A at 24Vdc (DC-13) with fixed screw terminal connections. The S3UM sub-range model features dimensions of W22.5mm x D122 mm, an IP40 degree of protection, and a supply voltage range of 20.4-26.4Vdc (24Vdc nominal). It operates at a frequency range of 40-400Hz, with a power consumption of 1.5 W, and is constructed with a PPO housing. This unit is designed for a 3-phase (3AC) input network with a rated voltage (AC) of 500/550Vac measuring voltage and a net width of 22.5 mm. It offers operating modes including fault latching/non-latching and normally energized/de-energized modes, with an ambient air temperature range for storage of -40 to +85°C. The device includes 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc DC-1 resistive load; 0.5-10s time-delay selectable) and 1 x analog input for L1-L3 voltage measurement. Protection functions cover undervoltage, overvoltage, phase sequence, phase failure, and asymmetry, with 1 x automatic reset and 1 x switching commutation digital inputs.
Quick Quote
Pilz PILZ-837270 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and is designed with a 40 percent hysteresis. It features safety output contacts ratings of 0.1A-5A at 24Vdc (DC-1; 120W) and 1.5A at 24Vdc (DC-13). Connection is established via fixed screw terminal connections. As part of the S3UM sub-range, this unit measures 22.5mm in width, offers an IP40 degree of protection, and requires a supply voltage of 20.4-26.4Vdc (24Vdc nominal). It can measure frequencies between 40-400Hz and is housed in PPO material. Designed for a 3-phase (3AC) input network, it has a rated voltage for measuring of 400/440Vac. The unit's power consumption is 1.5 W, with dimensions of 22.5mm in width and 122mm in depth. It supports both fault latching and non-latching operating modes, normally energized and normally de-energized modes, and can be stored in temperatures ranging from -40 to +85°C. It includes 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc DC-1 resistive load; 0.5-10s time-delay selectable) and 1 x analog input for L1-L3 voltage measurement. Protection functions cover undervoltage, overvoltage, phase sequence, phase failure, and asymmetry, with 1 x automatic reset and 1 x switching commutation digital inputs.
Quick Quote
Pilz PILZ-828035 is a protection unit designed for current monitoring relay applications, featuring DIN rail mounting for easy installation. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. This unit is capable of measuring currents ranging from 0.01 to 15A and is equipped with fixed screw terminal connections. It requires a supply voltage of 42Vac to 48Vac and falls under the S1IM sub-range. With dimensions of W22.5mm and a degree of protection rated at IP40, it is suitable for various environments. The frequency measuring range is 40-400Hz, and it is housed in a PPO material. Designed for single-phase (1AC) input networks, it has a net width of 22.5 mm and a depth of 121 mm. Power consumption is minimal at 2 VA. The operating modes include fault latching or non-latching, normally energized mode, or normally de-energized mode. It can be stored in temperatures ranging from -40 to +85°C. The unit features 1 x auxiliary output (SPDT-NO/NC contacts) for digital outputs, and protection functions against overcurrent. Digital inputs include 1 x latching/non-latching input, 1 x energized/de-energized mode input, and 1 x measuring range input for versatile application.
Quick Quote
Pilz PILZ-827250 is a single-phase voltage monitoring relay designed for DIN rail mounting, ensuring compatibility with standard industrial setups. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. This protection unit features measuring inputs that are not polarity-sensitive and offers safety output contacts ratings ranging from 0.1A to 5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15). It is equipped with fixed screw terminal connections and requires a supply voltage of 93.5-143Vac (110Vac / 120Vac nominal) within the S1UM sub-range. The device measures 22.5mm in width, has a degree of protection of IP40, and operates across a frequency range of 0.4-400Hz. Constructed with a PPO housing, it is designed for single-phase (1AC) input networks and can handle a rated voltage of 0.1-500Vac/dc (adjustable measuring voltage). The net width is 22.5 mm, and it has a power consumption of 2 VA, with a net depth of 121 mm. The operating modes include fault latching or non-latching and normally energized or de-energized modes. It can be stored in temperatures ranging from -40 to +85°C. The unit features 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load) and is equipped with digital inputs for de-energized mode (Y1-Y2) and latching (Y3). Its protection functions guard against overvoltage, with a response time of 0.1-10 seconds.
Quick Quote
Pilz PILZ-827255 is a protection unit designed as a single-phase voltage monitoring relay suitable for DIN rail mounting. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. The unit features safety output contacts with ratings of 0.1A-5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15), utilizing fixed screw terminal connections. It requires a supply voltage of 195.5-264Vac (230Vac / 240Vac nominal) within the S1UM sub-range and offers a compact design with dimensions of W22.5mm x D121 mm, and a net width of 22.5 mm, ensuring an IP40 degree of protection. The frequency measuring range is 0.4-400Hz, housed in a PPO material casing. This unit is designed for single-phase (1AC) input networks with a rated voltage for measuring of 0.1-500Vac/dc (adjustable). It consumes 2 VA of power and supports both fault latching/non-latching and normally energized/de-energized operating modes. The ambient air temperature for storage is specified as -40 to +85°C. It includes 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load) and digital inputs for de-energized mode (Y1-Y2) and latching (Y3). The protection functions cover overvoltage with a response time of 0.1-10 seconds.
Quick Quote
Pilz PILZ-827245 is a protection unit designed for single-phase voltage monitoring with a DIN rail mounting mode. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. The unit features safety output contacts ratings of 0.1A-5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15), with fixed screw terminal connections. The supply voltage is specified at 93.5-143Vac (110Vac / 120Vac nom.) within the S1UM sub-range. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. The frequency measuring range is 0.4-400Hz, housed in a PPO material. It is designed for a single-phase (1AC) input network, with a rated voltage (AC) for measuring voltage adjustable between 0.1-500Vac/dc. The net width is 22.5 mm, and it consumes 2 VA of power with a net depth of 121 mm. Operating modes include fault latching/non-latching and normally energized/de-energized modes. The ambient air temperature for storage ranges from -40 to +85°C. It features 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load) for digital outputs, and protection functions against overvoltage with a response time of 0.1-10 s. Digital inputs include 1 x de-energized mode input (Y1-Y2) and 1 x latching input (Y3).
Quick Quote
Pilz PILZ-827225 is a protection unit designed for single-phase voltage monitoring with a DIN rail mounting option. It operates within an ambient air temperature range of -15 to +55 °C and has a net height of 87 mm. The design ensures that measuring inputs are not polarity-sensitive. It features safety output contacts ratings of 0.1A-5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15), with fixed screw terminal connections. The supply voltage requirement is 20.4-26.4Vac (24Vac nominal) under the sub-range name S1UM. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. The frequency measuring range is 0.4-400Hz, housed in a PPO material. It is suitable for single-phase (1AC) input networks with a rated voltage (AC) for measuring voltage adjustable between 0.1-500Vac/dc. The net width and depth are 22.5 mm and 121 mm, respectively, with a power consumption of 2 VA. Operating modes include fault latching/non-latching and normally energized/de-energized modes. It can be stored in temperatures ranging from -40 to +85 °C. The unit has 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load) for digital outputs, and digital inputs include 1 x de-energized mode input (Y1-Y2) and 1 x latching input (Y3). Protection functions cover overvoltage with a response time of 0.1-10 s.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
PILZ-837300 Pilz PILZ-837300 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 24Vdc (DC-1; 120W) and 1.5A at 24Vdc (DC-13). Connection is facilitated through fixed screw terminal connections. As part of the S3UM sub-range, this unit measures 22.5mm in width, offers an IP40 degree of protection, and requires a supply voltage of 20.4-26.4Vdc (24Vdc nominal). It operates across a frequency measuring range of 40-400Hz and is housed in PPO material. Designed for a 3-phase (3AC) input network, it measures rated voltages of 208/400/480Vac and has a net width of 22.5 mm. Power consumption is rated at 1.5 W, with a net depth of 122 mm. Operating modes include fault latching/non-latching and normally energized/de-energized modes. Storage temperature tolerance ranges from -40 to +85°C. It features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc DC-1 resistive load; 0.5-10s time-delay selectable), 1 x analog input for L1-L3 voltage measurement, and protection functions against undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. Additionally, it includes 1 x automatic reset and 1 x switching commutation digital inputs. | Pilz | Quick Quote | |||
PILZ-837290 Pilz PILZ-837290 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15). Connection is facilitated through fixed screw terminal connections, and it requires a supply voltage of 20.4-26.4Vac (24Vac nominal) within the S3UM sub-range. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. The frequency measuring range is 40-400Hz, and it is housed in a PPO material. Designed for a 3-phase (3AC) input network, it has a rated voltage for measuring of 208/400/480Vac, a net width of 22.5 mm, and consumes 1.5 W of power. The net depth is 122 mm. Operating modes include fault latching or non-latching and normally energized or de-energized modes. It can be stored in temperatures ranging from -40 to +85°C. The unit features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load; 0.5-10s time-delay selectable for ON-delay energization), 1 x analog input for L1-L3 voltage measurement, and protection functions against undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. Digital inputs include 1 x automatic reset (Y1-Y2 linked) and 1 x switching commutation (Y2-Y3). | Pilz | Quick Quote | |||
PILZ-837285 Pilz PILZ-837285 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 24Vdc (DC-1; 120W) and 1.5A at 24Vdc (DC-13) with fixed screw terminal connections. The S3UM sub-range model features dimensions of W22.5mm x D122 mm, an IP40 degree of protection, and a supply voltage range of 20.4-26.4Vdc (24Vdc nominal). It operates at a frequency range of 40-400Hz, with a power consumption of 1.5 W, and is constructed with a PPO housing. This unit is designed for a 3-phase (3AC) input network with a rated voltage (AC) of 500/550Vac measuring voltage and a net width of 22.5 mm. It offers operating modes including fault latching/non-latching and normally energized/de-energized modes, with an ambient air temperature range for storage of -40 to +85°C. The device includes 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc DC-1 resistive load; 0.5-10s time-delay selectable) and 1 x analog input for L1-L3 voltage measurement. Protection functions cover undervoltage, overvoltage, phase sequence, phase failure, and asymmetry, with 1 x automatic reset and 1 x switching commutation digital inputs. | Pilz | Quick Quote | |||
PILZ-837270 Pilz PILZ-837270 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and is designed with a 40 percent hysteresis. It features safety output contacts ratings of 0.1A-5A at 24Vdc (DC-1; 120W) and 1.5A at 24Vdc (DC-13). Connection is established via fixed screw terminal connections. As part of the S3UM sub-range, this unit measures 22.5mm in width, offers an IP40 degree of protection, and requires a supply voltage of 20.4-26.4Vdc (24Vdc nominal). It can measure frequencies between 40-400Hz and is housed in PPO material. Designed for a 3-phase (3AC) input network, it has a rated voltage for measuring of 400/440Vac. The unit's power consumption is 1.5 W, with dimensions of 22.5mm in width and 122mm in depth. It supports both fault latching and non-latching operating modes, normally energized and normally de-energized modes, and can be stored in temperatures ranging from -40 to +85°C. It includes 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc DC-1 resistive load; 0.5-10s time-delay selectable) and 1 x analog input for L1-L3 voltage measurement. Protection functions cover undervoltage, overvoltage, phase sequence, phase failure, and asymmetry, with 1 x automatic reset and 1 x switching commutation digital inputs. | Pilz | Quick Quote | |||
PILZ-828035 Pilz PILZ-828035 is a protection unit designed for current monitoring relay applications, featuring DIN rail mounting for easy installation. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. This unit is capable of measuring currents ranging from 0.01 to 15A and is equipped with fixed screw terminal connections. It requires a supply voltage of 42Vac to 48Vac and falls under the S1IM sub-range. With dimensions of W22.5mm and a degree of protection rated at IP40, it is suitable for various environments. The frequency measuring range is 40-400Hz, and it is housed in a PPO material. Designed for single-phase (1AC) input networks, it has a net width of 22.5 mm and a depth of 121 mm. Power consumption is minimal at 2 VA. The operating modes include fault latching or non-latching, normally energized mode, or normally de-energized mode. It can be stored in temperatures ranging from -40 to +85°C. The unit features 1 x auxiliary output (SPDT-NO/NC contacts) for digital outputs, and protection functions against overcurrent. Digital inputs include 1 x latching/non-latching input, 1 x energized/de-energized mode input, and 1 x measuring range input for versatile application. | Pilz | Quick Quote | |||
PILZ-827250 Pilz PILZ-827250 is a single-phase voltage monitoring relay designed for DIN rail mounting, ensuring compatibility with standard industrial setups. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. This protection unit features measuring inputs that are not polarity-sensitive and offers safety output contacts ratings ranging from 0.1A to 5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15). It is equipped with fixed screw terminal connections and requires a supply voltage of 93.5-143Vac (110Vac / 120Vac nominal) within the S1UM sub-range. The device measures 22.5mm in width, has a degree of protection of IP40, and operates across a frequency range of 0.4-400Hz. Constructed with a PPO housing, it is designed for single-phase (1AC) input networks and can handle a rated voltage of 0.1-500Vac/dc (adjustable measuring voltage). The net width is 22.5 mm, and it has a power consumption of 2 VA, with a net depth of 121 mm. The operating modes include fault latching or non-latching and normally energized or de-energized modes. It can be stored in temperatures ranging from -40 to +85°C. The unit features 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load) and is equipped with digital inputs for de-energized mode (Y1-Y2) and latching (Y3). Its protection functions guard against overvoltage, with a response time of 0.1-10 seconds. | Pilz | Quick Quote | |||
PILZ-827255 Pilz PILZ-827255 is a protection unit designed as a single-phase voltage monitoring relay suitable for DIN rail mounting. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. The unit features safety output contacts with ratings of 0.1A-5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15), utilizing fixed screw terminal connections. It requires a supply voltage of 195.5-264Vac (230Vac / 240Vac nominal) within the S1UM sub-range and offers a compact design with dimensions of W22.5mm x D121 mm, and a net width of 22.5 mm, ensuring an IP40 degree of protection. The frequency measuring range is 0.4-400Hz, housed in a PPO material casing. This unit is designed for single-phase (1AC) input networks with a rated voltage for measuring of 0.1-500Vac/dc (adjustable). It consumes 2 VA of power and supports both fault latching/non-latching and normally energized/de-energized operating modes. The ambient air temperature for storage is specified as -40 to +85°C. It includes 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load) and digital inputs for de-energized mode (Y1-Y2) and latching (Y3). The protection functions cover overvoltage with a response time of 0.1-10 seconds. | Pilz | Quick Quote | |||
PILZ-827245 Pilz PILZ-827245 is a protection unit designed for single-phase voltage monitoring with a DIN rail mounting mode. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. The unit features safety output contacts ratings of 0.1A-5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15), with fixed screw terminal connections. The supply voltage is specified at 93.5-143Vac (110Vac / 120Vac nom.) within the S1UM sub-range. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. The frequency measuring range is 0.4-400Hz, housed in a PPO material. It is designed for a single-phase (1AC) input network, with a rated voltage (AC) for measuring voltage adjustable between 0.1-500Vac/dc. The net width is 22.5 mm, and it consumes 2 VA of power with a net depth of 121 mm. Operating modes include fault latching/non-latching and normally energized/de-energized modes. The ambient air temperature for storage ranges from -40 to +85°C. It features 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load) for digital outputs, and protection functions against overvoltage with a response time of 0.1-10 s. Digital inputs include 1 x de-energized mode input (Y1-Y2) and 1 x latching input (Y3). | Pilz | Quick Quote | |||
PILZ-827225 Pilz PILZ-827225 is a protection unit designed for single-phase voltage monitoring with a DIN rail mounting option. It operates within an ambient air temperature range of -15 to +55 °C and has a net height of 87 mm. The design ensures that measuring inputs are not polarity-sensitive. It features safety output contacts ratings of 0.1A-5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15), with fixed screw terminal connections. The supply voltage requirement is 20.4-26.4Vac (24Vac nominal) under the sub-range name S1UM. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. The frequency measuring range is 0.4-400Hz, housed in a PPO material. It is suitable for single-phase (1AC) input networks with a rated voltage (AC) for measuring voltage adjustable between 0.1-500Vac/dc. The net width and depth are 22.5 mm and 121 mm, respectively, with a power consumption of 2 VA. Operating modes include fault latching/non-latching and normally energized/de-energized modes. It can be stored in temperatures ranging from -40 to +85 °C. The unit has 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load) for digital outputs, and digital inputs include 1 x de-energized mode input (Y1-Y2) and 1 x latching input (Y3). Protection functions cover overvoltage with a response time of 0.1-10 s. | Pilz | Quick Quote |