RI60P1-QR20-LU4X2-H1141 Miniature Encoder, With Analog Output, Premium Line

About the manufacturer: Turck is one of the manufacturers that offers Encoders that you can order at Powermatic Associates site. Turck is a leading provider of sensor, fieldbus, and connectivity technologies, along with interface technology, human-machine interfaces (HMI), and RFID systems. We offer innovative solutions for factory and process automation requirements, guaranteeing top-notch performance.

Check out the RI60P1-QR20-LU4X2-H1141 Turck price in the box on the right side or send a quick quote.

Product Details

  • Weight
    100 g
  • Protection class
    IP68/IP69K
  • Ambient temperature
    -40…+85 °C
  • Housing material
    Plastic, Ultem
  • Voltage output
    0.5…4.5 V
  • Electrical connection
    Connector, M12 × 1
  • Output function
    Analog output
  • Operating voltage
    8…30 VDC
  • Measuring range
    -30…30°
  • Construction size
    71.6 x 62.6 x 20 mm
  • Flange type
    Flange without mounting element
  • Shaft diameter D [mm]
    6  mm6.35  mm
  • Technology
    Contactless
  • Shaft Type
    Blind hole shaft
  • Output type
    Absolute singleturn
  • Encoder line
    Premium-Line

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


RI60P1-QR20-LU4X2-H1141 Description

Turck RI60P1-QR20-LU4X2-H1141 is a contactless rotary inductive angle sensor designed for precise angle measurement. It operates within an ambient air temperature range of -25 to +85°C and features a blind hole shaft that is washdown-resistant. This sensor is equipped with a 4-pin M12 Eurofast QD male connector for easy connection. It belongs to the Q-track QR20 series and has dimensions of H63mm x W72mm x D20mm. The sensor offers a high degree of protection with ratings of IP68 and IP69K, making it suitable for harsh environments. It requires a supply voltage of 8Vdc to 30Vdc, with a nominal range of 12Vdc to 24Vdc, and has a rectangular shape. The sampling rate is 800Hz, and it is constructed with a durable Plastic Ultem housing. The bore size is 6mm, and it includes protection functions against short-circuit and reverse polarity. It provides one analog output ranging from 0.5Vdc to 4.5Vdc. The resolution is less than or equal to 0.09° with a 12-bit resolution. A green LED serves as a multifunctional visual position indicator, and another green LED indicates power ON. The measurement accuracy is noted with a 0.09° resolution, and the current consumption is 100mA. It is capable of measuring angular positions from 0° to +60°.



Related documents RI60P1-QR20-LU4X2-H1141 Specs

Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts

UBC10.241

UBC10.241

PULS UBC10.241 is an Uninterruptible Power Supply (UPS) control module within the U-series, featuring a built-in battery with a 50% power reserve and a green status LED. This module is housed in aluminium and utilizes spring-clamp connections for installation. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can reach up to 15A in buffer mode for less than 5 seconds at full output voltage. It supports DIN rail mounting and can operate in ambient air temperatures ranging from 0 to +40°C. The current consumption is 1.1A at a 24Vdc input, and it is designed for DC networks. Visual position indicators include Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. It is advised not to use the DC-UPS in parallel to increase output power, but paralleling two units for 1+1 redundancy is possible for higher system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. The efficiency is rated at 0.978 with a 24Vdc input, and the rated power is 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W with a 24Vdc input at 0A output current and 5.5W at 10A output current. Ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. The electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output.

Puls

1