About the manufacturer: Turck is one of the manufacturers that offers Linear Position Sensors that you can order at Powermatic Associates site. Turck is a leading provider of sensor, fieldbus, and connectivity technologies, along with interface technology, human-machine interfaces (HMI), and RFID systems. We offer innovative solutions for factory and process automation requirements, guaranteeing top-notch performance.

Check out the LI800P2-Q25LM1-LIU5X3-H1151 Turck price in the box on the right side or send a quick quote.

Product Details

  • Weight
    1200 g
  • Ambient temperature
    -25…+70 °C
  • Protection class
    IP67
  • Housing material
    Aluminum/plastic, PA6-GF30, Anodized
  • Electrical connection
    Connector, M12 × 1
  • Current output
    4…20 mA
  • Voltage output
    0…10 V
  • Output function
    Analog output
  • Measuring range
    800 mm [31.50 in]
  • Operating voltage
    15…30 VDC
  • Measuring principle
    Inductive
  • Design
    Profile

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


LI800P2-Q25LM1-LIU5X3-H1151 Description

Turck LI800P2-Q25LM1-LIU5X3-H1151 is an encoder (linear) from the Q-track Q25 series, designed as a contactless linear inductive positioning sensor. It features a 68mm long mounting foot and a free-moving positioning element, with dimensions of H35mm x W25mm x D858mm. The rectangular shape is constructed from an aluminium / plastic PA6-GF30 anodized housing, with both the active area and sensing face made of plastic PA6-GF30. It comes pre-equipped with a 5-pin M12 Eurofast QD male connector for connectivity. The encoder offers protection functions against short-circuit, wire-break, and reverse polarity. It operates on a supply voltage of 15Vdc-30Vdc (24Vdc nom.) and can function in ambient air temperatures ranging from -25 to +70°C. With an IP67 degree of protection, it features a stroke length with 29mm blind zones at both ends, a 1.5mm nominal distance, and an 800mm measurement span. The analog output is 1 x analog (0-10Vdc / 4-20mA; 12-bit resolution), with a current consumption of 50mA and a 500Hz sampling rate. Measurement accuracy is detailed with a 16-bits resolution (equivalent to 0.013mm / 13μm linear resolution), ≤ 0.02% of full scale repeatability, ≤ +/-0.003% / K temperature drift, and ≤ 0.1% of full scale linearity deviation. It also includes a visual position indicator with green / yellow / yellow flashing LED for multifunction and a green LED for power ON, alongside a 16-bit resolution.



Related documents LI800P2-Q25LM1-LIU5X3-H1151 Specs

Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts

UBC10.241

UBC10.241

PULS UBC10.241 is an Uninterruptible Power Supply (UPS) control module within the U-series, featuring a built-in battery with a 50% power reserve and a green status LED. This module is housed in aluminium and utilizes spring-clamp connections for installation. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can reach up to 15A in buffer mode for less than 5 seconds at full output voltage. It supports DIN rail mounting and can operate in ambient air temperatures ranging from 0 to +40°C. The current consumption is 1.1A at a 24Vdc input, and it is designed for DC networks. Visual position indicators include Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. It is advised not to use the DC-UPS in parallel to increase output power, but paralleling two units for 1+1 redundancy is possible for higher system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. The efficiency is rated at 0.978 with a 24Vdc input, and the rated power is 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W with a 24Vdc input at 0A output current and 5.5W at 10A output current. Ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. The electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output.

Puls

1