GV7RS25 Schneider Electric Manual Motor Protectors

Schneider Electric GV7RS25 Schneider Electric GV7RS25 is a Motor Protection Circuit Breaker (MPCB) within the GV7RE sub-range, designed for thermal-magnetic motor protection and manual motor starting. It features 3 poles and provides protection functions against short-circuit and thermal overload. The rated current ranges from 15 to 25 A, with a rated insulation voltage (Ui) of 750 V. This MPCB is designed for DIN rail or mounting plate installation, has a net width of 105 mm, and operates via a toggle mechanism. Protection settings for short-circuit pickup current are fixed at 25A. The rated impulse voltage (Uimp) is 8 kV, and it supports rated active power (kW) of 11 kW and 9 kW at 400/415Vac, 15 kW and 11 kW at 500Vac, and 18.5 kW and 15 kW at 690Vac. The trip current rating is 25 AT, with a frame current rating of 100 AF. It boasts mechanical durability of 50,000 operations at no load and electrical durability of 30,000 operations at 440Vac; AC-3. The GV7RS25 uses screw-clamp terminals, has a rated voltage (AC) phase-to-phase of 690 V, and protects all 3 poles. The minimum and maximum currents are 15 A and 25 A, respectively, with a trip unit type of thermal-magnetic and a utilization category of AC-3.
Schneider Electric

Part#:GV7RS25

Manufacturer:Schneider Electric

Product Lifecycle:Active

Get a quick Quote!

Schneider Electric GV7RS25 is a Motor Protection Circuit Breaker (MPCB) within the GV7RE sub-range, designed for thermal-magnetic motor protection and manual motor starting. It features 3 poles and provides protection functions against short-circuit and thermal overload. The rated current ranges from 15 to 25 A, with a rated insulation voltage (Ui) of 750 V. This MPCB is designed for DIN rail or mounting plate installation, has a net width of 105 mm, and operates via a toggle mechanism. Protection settings for short-circuit pickup current are fixed at 25A. The rated impulse voltage (Uimp) is 8 kV, and it supports rated active power (kW) of 11 kW and 9 kW at 400/415Vac, 15 kW and 11 kW at 500Vac, and 18.5 kW and 15 kW at 690Vac. The trip current rating is 25 AT, with a frame current rating of 100 AF. It boasts mechanical durability of 50,000 operations at no load and electrical durability of 30,000 operations at 440Vac; AC-3. The GV7RS25 uses screw-clamp terminals, has a rated voltage (AC) phase-to-phase of 690 V, and protects all 3 poles. The minimum and maximum currents are 15 A and 25 A, respectively, with a trip unit type of thermal-magnetic and a utilization category of AC-3.

About the manufacturer: Schneider Electric is one of the manufacturers that offers Manual Motor Protectors that you can order at Powermatic Associates site. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.

Check out the GV7RS25 Schneider Electric price in the box on the right side or send a quick quote.

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


GV7RS25 Description

Schneider Electric GV7RS25 is a Motor Protection Circuit Breaker (MPCB) within the GV7RE sub-range, designed for thermal-magnetic motor protection and manual motor starting. It features 3 poles and provides protection functions against short-circuit and thermal overload. The rated current ranges from 15 to 25 A, with a rated insulation voltage (Ui) of 750 V. This MPCB is designed for DIN rail or mounting plate installation, has a net width of 105 mm, and operates via a toggle mechanism. Protection settings for short-circuit pickup current are fixed at 25A. The rated impulse voltage (Uimp) is 8 kV, and it supports rated active power (kW) of 11 kW and 9 kW at 400/415Vac, 15 kW and 11 kW at 500Vac, and 18.5 kW and 15 kW at 690Vac. The trip current rating is 25 AT, with a frame current rating of 100 AF. It boasts mechanical durability of 50,000 operations at no load and electrical durability of 30,000 operations at 440Vac; AC-3. The GV7RS25 uses screw-clamp terminals, has a rated voltage (AC) phase-to-phase of 690 V, and protects all 3 poles. The minimum and maximum currents are 15 A and 25 A, respectively, with a trip unit type of thermal-magnetic and a utilization category of AC-3.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts

UBC10.241

UBC10.241

PULS UBC10.241 is an Uninterruptible Power Supply (UPS) control module within the U-series, featuring a built-in battery with a 50% power reserve and a green status LED. This module is housed in aluminium and utilizes spring-clamp connections for installation. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can reach up to 15A in buffer mode for less than 5 seconds at full output voltage. It supports DIN rail mounting and can operate in ambient air temperatures ranging from 0 to +40°C. The current consumption is 1.1A at a 24Vdc input, and it is designed for DC networks. Visual position indicators include Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. It is advised not to use the DC-UPS in parallel to increase output power, but paralleling two units for 1+1 redundancy is possible for higher system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. The efficiency is rated at 0.978 with a 24Vdc input, and the rated power is 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W with a 24Vdc input at 0A output current and 5.5W at 10A output current. Ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. The electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output.

Puls

1