Schneider Electric GV2P08 is a Motor Protection Circuit Breaker (MPCB) within the GV2P sub-range, designed for thermal-magnetic motor protection and manual motor starting. It features 3 poles and provides protection functions against short-circuit and thermal overload with a rated current of 2.5 - 4 A. The device has a rated insulation voltage (Ui) of 690 V and is suitable for DIN rail mounting. It operates via a rotary knob, with protection settings for short-circuit pickup current fixed at 51A. The GV2P08 has a rated impulse voltage (Uimp) of 6 kV and supports rated active powers of 1.1 kW at 400/415Vac, 1.5 kW at 500Vac, and 2.2 kW at 690Vac. Its trip current rating is 4 AT, with a frame current rating of 32 AF. This MPCB boasts mechanical durability of 100,000 operations at no load and electrical durability of 100,000 operations at 415Vac; AC-3 with load. It features screw-clamp terminals, a rated voltage (AC) phase-to-phase of 690 V, and all three poles are protected. The minimum current is 2.5 A, and the maximum current is 4 A, with a trip unit type of thermal-magnetic and a utilisation category of A AC-3.
Quick Quote
Schneider Electric GVAU125 is a coil designed for tripping purposes within the GV2 sub-range. It functions as an undervoltage trip coil (MN) with a rated insulation voltage (Ui) of 690 V. The control voltage for AC at 50Hz is specified at 120-127 Vac. Its mechanical durability is rated at 30,000 operations when used with GV2ME/GV2P and 10,000 operations with GV3P/GV3L. This part is equipped with screw-clamp type terminals.
Quick Quote
Schneider Electric GV2GA01 is a connector within the GV2 sub-range designed specifically for PCB connections. It features a 3-pole configuration, catering to applications that require a set of connections for printed circuit boards.
Quick Quote
ABB 1SAM340000R1006 is a protection unit designed with thermal-magnetic circuit breaker functionality for transformer primary protection. It features screw-clamp connections and offers an adjustable rated current of 1A to 1.6A. This unit operates within an ambient air temperature range for operation of -25 to +70°C and for storage from -50 to +80°C. It is equipped with a control voltage (DC) rating of IP20, a rated impulse voltage (Uimp) of 6 kV, and a net width of 45 mm. The protection functions include 3-poles (3P) for short circuit protection, phase failure/loss, and transformer protection. With a net depth of 86.75 mm and a rated insulation voltage (Ui) of 690 V, it supports a rated active power that allows for mounting on DIN rails or mounting plates. The primary current rating is 690 V, and it is designed for 100,000 operations with an ON/OFF/TRIP rotary knob for control. The unit's length supports 100,000 operations, and it offers thermal protection for overloads adjustable between 1A and 1.6A.
Quick Quote
ABB 1SAM580000R1008 is a Thermal-Magnetic Motor Protection Circuit Breaker (MPCB) designed for manual motor starter protection. It features screw-clamp connections and offers an adjustable rated current range of 57A to 75A. The device operates within an ambient air temperature range of -20 to +70°C for operation and has a storage temperature range of -50 to +80°C. It provides a degree of protection rated at IP20 and is designed for a 450Vdc environment. The MPCB has a net width of 165 mm, poles rated at 6 kV, and a net depth of 174 mm. It supports a rated insulation voltage (Ui) of 690 V across 3 poles (3P) and includes protection functions such as short circuit protection, phase failure/phase loss, and thermal overload. The component utilizes DIN rail mounting technology and has a control voltage (AC) of 690 V. It is designed for 25 000 operations with a rated power (HP) of 25HP (UL/CSA, 208Vac) and 60HP (UL/CSA, 220-240Vac phase-to-phase; 440-480Vac phase-to-neutral). The primary voltage is rated for 50 000 operations. The MPCB features magnetic protection with a short-circuit pickup current fixed at 975A and thermal protection with an adjustable overload current range of 57A to 75A.
Quick Quote
ABB 1SAM340000R1013 is a protection unit designed with thermal-magnetic circuit breaker functionality for transformer primary protection. It features screw-clamp connections and offers an adjustable rated current of 16A to 20A. This unit is designed to operate within an ambient air temperature range of -25 to +70°C for operation and -50 to +80°C for storage. It supports a control voltage (DC) of IP20 and has a rated impulse voltage (Uimp) of 6 kV. The device measures 97.8 mm in net width, with poles extending 45 mm, and incorporates 3-poles (3P) for protection functions including short circuit protection, phase failure or loss, and transformer protection. The net depth is 690 V, and the control voltage (AC) stands at 86.55 mm. It is capable of mounting on DIN rails or mounting plates, with a primary current of 690 V and an operating mode designed for 50,000 operations. The unit features an ON/OFF/TRIP rotary knob for flow control, supports up to 100,000 operations in length, and offers thermal protection for overloads adjustable between 16A and 20A.
Quick Quote
ABB 1SAM350005R1013 is a Motor Protection Circuit Breaker (MPCB) designed for thermal-magnetic motor protection. It features manual motor starter protector functionality with screw-clamp connections. The rated current is adjustable between 16A and 20A, with specific ratings under UL/CSA for Full Load Amps (FLA) and Locked Rotor Amperes (LRA) across various voltages (200Vac, 208Vac, 220-240Vac, 440-480Vac, 550-600Vac). It includes Normally Open (NO) auxiliary contacts and is designed for a supply voltage (AC) of 550-600Vac. The MPCB offers a degree of protection with front-mounted auxiliary contact blocks (1NO+1NC) and operates within an ambient air temperature range of -25 to +70°C. It is equipped with a 3-pole (3P) configuration, rated insulation voltage (Ui) of 690V, and an IP20 protection rating. The device has a net width of 97.8mm, power consumption of 6kV, and is colored with a 45mm dimension. It supports a connection capacity of 7.5kW (400/415Vac) and is designed for a network frequency of 50Hz. The MPCB is capable of 50,000 operations, with a mechanical durability of 100,000 operations at no load. It features short circuit protection, phase failure/loss, and thermal overload Class 10 protection, with an operating rate that includes both thermal and magnetic (adjustable) protection mechanisms. The magnetic protection has a short-circuit pickup current fixed at 300A, while the thermal protection allows for an overload setting of 16A to 20A (adjustable). This part mounts on a DIN rail or mounting plate and is designed for use in environments with a climatic resistance of 100,000 operations.
Quick Quote
Square D by Schneider Electric LRL36400M37X is a Motor Protection Circuit Breaker (MPCB) within the PowerPacT LRL sub-range, designed for electronic motor protection, manual motor starting, and motor circuit protection. This PowerPacT L-Frame 600 Micrologic 1.3M (LI) model features a 3-pole (3P) design with a rated current of 400A and a rated insulation voltage (Ui) of 750 V. It operates at a rated voltage (AC) of 600Vac 600Y/347Vac, with a mounting mode that allows for individual unit mount on a plate. The connection type includes lugs on both load and line sides, ensuring a secure connection. It offers protection functions including instantaneous protection (I), with protection settings fixed at 4800A for short-circuit incidents. The device has a rated operating voltage (Ue) of 690 V and a rated impulse voltage (Uimp) of 8 kV. Its net dimensions are 382 mm in height, 153 mm in width, and 171 mm in depth, with a degree of protection rated at IP40. The operating mode is manual toggle, and it features a trip current rating of 400 AT, a frame current rating of 600 AF, and a short circuit breaking rating that varies based on voltage levels, reaching up to 200kA for certain voltages under UL489 standards. The trip unit type is an electronic Micrologic 1.3M (I) with no display, categorized under utilisation category A.
Quick Quote
ABB 1SAM340000R1007 is a protection unit designed with thermal-magnetic circuit breaker functionality for transformer primary protection. It features screw-clamp connections and offers an adjustable rated current ranging from 1.6A to 2.5A. This unit operates within an ambient air temperature range for operation of -25 to +70°C and for storage from -50 to +80°C. It is equipped with a control voltage (DC) rating of IP20 and a rated impulse voltage (Uimp) of 6 kV. The device has a net width of 45 mm and provides protection with three poles (3P). It is designed for short circuit protection, phase failure/loss, and transformer protection with a rated insulation voltage (Ui) of 690 V. The control voltage (AC) stands at 86.75 mm, and it is capable of mounting on DIN rails or mounting plates. The operating mode is rated for 100,000 operations, with an ON/OFF/TRIP rotary knob for flow control. The unit's length supports 100,000 operations, and it features thermal protection (overload) with adjustable settings of 1.6A to 2.5A.
Quick Quote
ABB 1SAM340000R1003 is a protection unit designed with thermal-magnetic circuit breaker functionality for transformer primary protection. It features screw-clamp connections and offers an adjustable rated current ranging from 0.25A to 0.4A. The unit operates within an ambient air temperature range for operation of -25 to +70°C and for storage from -50 to +80°C. It is designed with an IP20 control voltage (DC), a rated impulse voltage (Uimp) of 6 kV, and a net width of 45 mm. This 3-pole (3P) protection unit provides short circuit protection, phase failure/loss, and transformer protection. It has a net depth of 86.75 mm, operates with a control voltage (AC), and has a rated insulation voltage (Ui) of 690 V. The unit is capable of 100,000 operations and features an ON/OFF/TRIP rotary knob for control. It mounts on DIN rails or mounting plates, supporting a primary current of 690 V and an operating mode of 100,000 operations. The angular positions offer thermal protection for overloads adjustable between 0.25A and 0.4A.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
GV2P08 Schneider Electric GV2P08 is a Motor Protection Circuit Breaker (MPCB) within the GV2P sub-range, designed for thermal-magnetic motor protection and manual motor starting. It features 3 poles and provides protection functions against short-circuit and thermal overload with a rated current of 2.5 - 4 A. The device has a rated insulation voltage (Ui) of 690 V and is suitable for DIN rail mounting. It operates via a rotary knob, with protection settings for short-circuit pickup current fixed at 51A. The GV2P08 has a rated impulse voltage (Uimp) of 6 kV and supports rated active powers of 1.1 kW at 400/415Vac, 1.5 kW at 500Vac, and 2.2 kW at 690Vac. Its trip current rating is 4 AT, with a frame current rating of 32 AF. This MPCB boasts mechanical durability of 100,000 operations at no load and electrical durability of 100,000 operations at 415Vac; AC-3 with load. It features screw-clamp terminals, a rated voltage (AC) phase-to-phase of 690 V, and all three poles are protected. The minimum current is 2.5 A, and the maximum current is 4 A, with a trip unit type of thermal-magnetic and a utilisation category of A AC-3. | Schneider Electric | $281.93 | Quick Quote | ||
GVAU125 Schneider Electric GVAU125 is a coil designed for tripping purposes within the GV2 sub-range. It functions as an undervoltage trip coil (MN) with a rated insulation voltage (Ui) of 690 V. The control voltage for AC at 50Hz is specified at 120-127 Vac. Its mechanical durability is rated at 30,000 operations when used with GV2ME/GV2P and 10,000 operations with GV3P/GV3L. This part is equipped with screw-clamp type terminals. | Schneider Electric | Quick Quote | |||
GV2GA01 Schneider Electric GV2GA01 is a connector within the GV2 sub-range designed specifically for PCB connections. It features a 3-pole configuration, catering to applications that require a set of connections for printed circuit boards. | Schneider Electric | Quick Quote | |||
1SAM340000R1006 ABB 1SAM340000R1006 is a protection unit designed with thermal-magnetic circuit breaker functionality for transformer primary protection. It features screw-clamp connections and offers an adjustable rated current of 1A to 1.6A. This unit operates within an ambient air temperature range for operation of -25 to +70°C and for storage from -50 to +80°C. It is equipped with a control voltage (DC) rating of IP20, a rated impulse voltage (Uimp) of 6 kV, and a net width of 45 mm. The protection functions include 3-poles (3P) for short circuit protection, phase failure/loss, and transformer protection. With a net depth of 86.75 mm and a rated insulation voltage (Ui) of 690 V, it supports a rated active power that allows for mounting on DIN rails or mounting plates. The primary current rating is 690 V, and it is designed for 100,000 operations with an ON/OFF/TRIP rotary knob for control. The unit's length supports 100,000 operations, and it offers thermal protection for overloads adjustable between 1A and 1.6A. | ABB Control | Quick Quote | |||
1SAM580000R1008 ABB 1SAM580000R1008 is a Thermal-Magnetic Motor Protection Circuit Breaker (MPCB) designed for manual motor starter protection. It features screw-clamp connections and offers an adjustable rated current range of 57A to 75A. The device operates within an ambient air temperature range of -20 to +70°C for operation and has a storage temperature range of -50 to +80°C. It provides a degree of protection rated at IP20 and is designed for a 450Vdc environment. The MPCB has a net width of 165 mm, poles rated at 6 kV, and a net depth of 174 mm. It supports a rated insulation voltage (Ui) of 690 V across 3 poles (3P) and includes protection functions such as short circuit protection, phase failure/phase loss, and thermal overload. The component utilizes DIN rail mounting technology and has a control voltage (AC) of 690 V. It is designed for 25 000 operations with a rated power (HP) of 25HP (UL/CSA, 208Vac) and 60HP (UL/CSA, 220-240Vac phase-to-phase; 440-480Vac phase-to-neutral). The primary voltage is rated for 50 000 operations. The MPCB features magnetic protection with a short-circuit pickup current fixed at 975A and thermal protection with an adjustable overload current range of 57A to 75A. | ABB Control | Quick Quote | |||
1SAM340000R1013 ABB 1SAM340000R1013 is a protection unit designed with thermal-magnetic circuit breaker functionality for transformer primary protection. It features screw-clamp connections and offers an adjustable rated current of 16A to 20A. This unit is designed to operate within an ambient air temperature range of -25 to +70°C for operation and -50 to +80°C for storage. It supports a control voltage (DC) of IP20 and has a rated impulse voltage (Uimp) of 6 kV. The device measures 97.8 mm in net width, with poles extending 45 mm, and incorporates 3-poles (3P) for protection functions including short circuit protection, phase failure or loss, and transformer protection. The net depth is 690 V, and the control voltage (AC) stands at 86.55 mm. It is capable of mounting on DIN rails or mounting plates, with a primary current of 690 V and an operating mode designed for 50,000 operations. The unit features an ON/OFF/TRIP rotary knob for flow control, supports up to 100,000 operations in length, and offers thermal protection for overloads adjustable between 16A and 20A. | ABB Control | Quick Quote | |||
1SAM350005R1013 ABB 1SAM350005R1013 is a Motor Protection Circuit Breaker (MPCB) designed for thermal-magnetic motor protection. It features manual motor starter protector functionality with screw-clamp connections. The rated current is adjustable between 16A and 20A, with specific ratings under UL/CSA for Full Load Amps (FLA) and Locked Rotor Amperes (LRA) across various voltages (200Vac, 208Vac, 220-240Vac, 440-480Vac, 550-600Vac). It includes Normally Open (NO) auxiliary contacts and is designed for a supply voltage (AC) of 550-600Vac. The MPCB offers a degree of protection with front-mounted auxiliary contact blocks (1NO+1NC) and operates within an ambient air temperature range of -25 to +70°C. It is equipped with a 3-pole (3P) configuration, rated insulation voltage (Ui) of 690V, and an IP20 protection rating. The device has a net width of 97.8mm, power consumption of 6kV, and is colored with a 45mm dimension. It supports a connection capacity of 7.5kW (400/415Vac) and is designed for a network frequency of 50Hz. The MPCB is capable of 50,000 operations, with a mechanical durability of 100,000 operations at no load. It features short circuit protection, phase failure/loss, and thermal overload Class 10 protection, with an operating rate that includes both thermal and magnetic (adjustable) protection mechanisms. The magnetic protection has a short-circuit pickup current fixed at 300A, while the thermal protection allows for an overload setting of 16A to 20A (adjustable). This part mounts on a DIN rail or mounting plate and is designed for use in environments with a climatic resistance of 100,000 operations. | ABB Control | Quick Quote | |||
LRL36400M37X Square D by Schneider Electric LRL36400M37X is a Motor Protection Circuit Breaker (MPCB) within the PowerPacT LRL sub-range, designed for electronic motor protection, manual motor starting, and motor circuit protection. This PowerPacT L-Frame 600 Micrologic 1.3M (LI) model features a 3-pole (3P) design with a rated current of 400A and a rated insulation voltage (Ui) of 750 V. It operates at a rated voltage (AC) of 600Vac 600Y/347Vac, with a mounting mode that allows for individual unit mount on a plate. The connection type includes lugs on both load and line sides, ensuring a secure connection. It offers protection functions including instantaneous protection (I), with protection settings fixed at 4800A for short-circuit incidents. The device has a rated operating voltage (Ue) of 690 V and a rated impulse voltage (Uimp) of 8 kV. Its net dimensions are 382 mm in height, 153 mm in width, and 171 mm in depth, with a degree of protection rated at IP40. The operating mode is manual toggle, and it features a trip current rating of 400 AT, a frame current rating of 600 AF, and a short circuit breaking rating that varies based on voltage levels, reaching up to 200kA for certain voltages under UL489 standards. The trip unit type is an electronic Micrologic 1.3M (I) with no display, categorized under utilisation category A. | Schneider Electric | Quick Quote | |||
1SAM340000R1007 ABB 1SAM340000R1007 is a protection unit designed with thermal-magnetic circuit breaker functionality for transformer primary protection. It features screw-clamp connections and offers an adjustable rated current ranging from 1.6A to 2.5A. This unit operates within an ambient air temperature range for operation of -25 to +70°C and for storage from -50 to +80°C. It is equipped with a control voltage (DC) rating of IP20 and a rated impulse voltage (Uimp) of 6 kV. The device has a net width of 45 mm and provides protection with three poles (3P). It is designed for short circuit protection, phase failure/loss, and transformer protection with a rated insulation voltage (Ui) of 690 V. The control voltage (AC) stands at 86.75 mm, and it is capable of mounting on DIN rails or mounting plates. The operating mode is rated for 100,000 operations, with an ON/OFF/TRIP rotary knob for flow control. The unit's length supports 100,000 operations, and it features thermal protection (overload) with adjustable settings of 1.6A to 2.5A. | ABB Control | Quick Quote | |||
1SAM340000R1003 ABB 1SAM340000R1003 is a protection unit designed with thermal-magnetic circuit breaker functionality for transformer primary protection. It features screw-clamp connections and offers an adjustable rated current ranging from 0.25A to 0.4A. The unit operates within an ambient air temperature range for operation of -25 to +70°C and for storage from -50 to +80°C. It is designed with an IP20 control voltage (DC), a rated impulse voltage (Uimp) of 6 kV, and a net width of 45 mm. This 3-pole (3P) protection unit provides short circuit protection, phase failure/loss, and transformer protection. It has a net depth of 86.75 mm, operates with a control voltage (AC), and has a rated insulation voltage (Ui) of 690 V. The unit is capable of 100,000 operations and features an ON/OFF/TRIP rotary knob for control. It mounts on DIN rails or mounting plates, supporting a primary current of 690 V and an operating mode of 100,000 operations. The angular positions offer thermal protection for overloads adjustable between 0.25A and 0.4A. | ABB Control | Quick Quote |