3001394 Phoenix Contact Terminal Blocks

Phoenix Contact 3001394 End cover, length: 77.5 mm, width: 1.5 mm, height: 73 mm, color: gray
Phoenix Contact

Part#:3001394

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 153

Sep 28, 2024

End cover, length: 77.5 mm, width: 1.5 mm, height: 73 mm, color: gray

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Powermatic Associates site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3001394 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    125 °C
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Length
    77.5 mm
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 11.0
    27141133
  • ECLASS 5.0
    27141100
  • ETIM 2.0
    EC000886
  • ECLASS 9.0
    27141133
  • UNSPSC 6.01
    30211827
  • ETIM 7.0
    EC000886
  • UNSPSC 19.0
    39121425
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 4.0
    21011300
  • ECLASS 4.1
    21011300
  • ETIM 6.0
    EC000886
  • UNSPSC 12.01
    39121424
  • UNSPSC 21.0
    39121425
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    27,5 MJ/kg
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Static insulating material application in cold
    -60 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Width
    1.5 mm
  • Height
    73 mm
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 10.0.1
    27141133
  • ECLASS 5.1
    27141100
  • ECLASS 7.0
    27141133
  • ETIM 4.0
    EC000886
  • UNSPSC 11
    39121424
  • UNSPSC 18.0
    39121425
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • Flammability rating according to UL 94
    V0
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 6.0
    27141100
  • ETIM 3.0
    EC000886
  • UNSPSC 7.0901
    39121424
  • UNSPSC 13.2
    39121425
  • UNSPSC 20.0
    39121425

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price within minutes.

Stock:

153

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts

UBC10.241

UBC10.241

PULS UBC10.241 is an Uninterruptible Power Supply (UPS) control module within the U-series, featuring a built-in battery with a 50% power reserve and a green status LED. This module is housed in aluminium and utilizes spring-clamp connections for installation. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can reach up to 15A in buffer mode for less than 5 seconds at full output voltage. It supports DIN rail mounting and can operate in ambient air temperatures ranging from 0 to +40°C. The current consumption is 1.1A at a 24Vdc input, and it is designed for DC networks. Visual position indicators include Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. It is advised not to use the DC-UPS in parallel to increase output power, but paralleling two units for 1+1 redundancy is possible for higher system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. The efficiency is rated at 0.978 with a 24Vdc input, and the rated power is 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W with a 24Vdc input at 0A output current and 5.5W at 10A output current. Ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. The electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output.

Puls

1