M-3447-6.3ES200 Novanta IMS Stepper Motors

Novanta IMS M-3447-6.3ES200 Novanta IMS M-3447-6.3ES200 is a 2-phase DC stepper motor within the Stepper motors sub-range, featuring a 200-line single-end optical encoder with an index mark and a smooth-shaft with a single flat (single shaft end) alongside triple (3) motor stack. It is designed for connection via bare end flying leads and operates at a rated current of 6.3A with a supply voltage range of 24Vdc-75Vdc, including specific ratings at 48Vdc, 60Vdc, and 72Vdc. This stepper motor is mounted using an 85x85mm flange and is specified for operation in ambient air temperatures ranging from -25 to +40 degrees Celsius. It has a moment of inertia of 2.70kg.cm^2 and can produce a stall torque of 770N.cm (1090oz-in). The storage temperature range for this motor extends from -25 to +70 degrees Celsius. It achieves a resolution of 1.8 degrees per step angle.
Novanta IMS

Part#:M-3447-6.3ES200

Manufacturer:Novanta IMS

Product Lifecycle:Active

Get a quick Quote!

Novanta IMS M-3447-6.3ES200 is a 2-phase DC stepper motor within the Stepper motors sub-range, featuring a 200-line single-end optical encoder with an index mark and a smooth-shaft with a single flat (single shaft end) alongside triple (3) motor stack. It is designed for connection via bare end flying leads and operates at a rated current of 6.3A with a supply voltage range of 24Vdc-75Vdc, including specific ratings at 48Vdc, 60Vdc, and 72Vdc. This stepper motor is mounted using an 85x85mm flange and is specified for operation in ambient air temperatures ranging from -25 to +40 degrees Celsius. It has a moment of inertia of 2.70kg.cm^2 and can produce a stall torque of 770N.cm (1090oz-in). The storage temperature range for this motor extends from -25 to +70 degrees Celsius. It achieves a resolution of 1.8 degrees per step angle.

Check out the M-3447-6.3ES200 Novanta IMS price in the box on the right side or send a quick quote.

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


M-3447-6.3ES200 Description

Novanta IMS M-3447-6.3ES200 is a 2-phase DC stepper motor within the Stepper motors sub-range, featuring a 200-line single-end optical encoder with an index mark and a smooth-shaft with a single flat (single shaft end) alongside triple (3) motor stack. It is designed for connection via bare end flying leads and operates at a rated current of 6.3A with a supply voltage range of 24Vdc-75Vdc, including specific ratings at 48Vdc, 60Vdc, and 72Vdc. This stepper motor is mounted using an 85x85mm flange and is specified for operation in ambient air temperatures ranging from -25 to +40 degrees Celsius. It has a moment of inertia of 2.70kg.cm^2 and can produce a stall torque of 770N.cm (1090oz-in). The storage temperature range for this motor extends from -25 to +70 degrees Celsius. It achieves a resolution of 1.8 degrees per step angle.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts

UBC10.241

UBC10.241

PULS UBC10.241 is an Uninterruptible Power Supply (UPS) control module within the U-series, featuring a built-in battery with a 50% power reserve and a green status LED. This module is housed in aluminium and utilizes spring-clamp connections for installation. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can reach up to 15A in buffer mode for less than 5 seconds at full output voltage. It supports DIN rail mounting and can operate in ambient air temperatures ranging from 0 to +40°C. The current consumption is 1.1A at a 24Vdc input, and it is designed for DC networks. Visual position indicators include Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. It is advised not to use the DC-UPS in parallel to increase output power, but paralleling two units for 1+1 redundancy is possible for higher system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. The efficiency is rated at 0.978 with a 24Vdc input, and the rated power is 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W with a 24Vdc input at 0A output current and 5.5W at 10A output current. Ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. The electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output.

Puls

1