41.52.9.110.0010 Finder Control Relays

41.52.9.110.0010 on Powermatic Associates
Finder

Part#:41.52.9.110.0010

Manufacturer:Finder

Product Lifecycle:Active

Get a quick Quote!

Finder 41.52.9.110.0010 is a relay with solder pin connection type, designed for a rated current of 8A at 250Vac (AC-1) and 8A at 30Vdc (DC-1), with auxiliary contacts rated for 0.3A at 110Vdc and 0.12A at 220Vdc (DC-1). It supports a supply voltage of 2C/O / DPDT (Double Pole Double Throw), with an ambient air temperature for operation at 400VA (230Vac) and for storage at 2000VA (250Vac, AC-1). The rated voltage for AC operation is specified with an ambient air temperature range of -40 to +85 degrees Celsius. It utilizes a communication protocol C, with a net width of 15.7 mm and a mounting mode width of 29 mm. The relay is rated for 2 poles, with a power consumption width of 12.6 mm. It features PCB plug-in mounting mode, with a number of Normally Closed (NC) circuits capable of 60,000 operations, and a length of AgNi (Silver Nickel) with a durability of 10,000,000 operations. The control voltage for AC is rated at 6 kV, indicating its protection functions.

About the manufacturer: Finder is one of the manufacturers that offers Control Relays that you can order at Powermatic Associates site. Established in 1993, Finder Relays, Inc., a subsidiary of Finder S.p.A., distributes the Finder product line in the United States. Situated north of Atlanta, Georgia, our facility boasts a robust infrastructure, enabling us to serve customers nationwide effectively.

Check out the 41.52.9.110.0010 Finder price in the box on the right side or send a quick quote.

Product Details

  • Rated power
    400VA (230Vac; AC-15) 2000VA (250Vac; AC-1)
  • Connection type
    Solder pin
  • Degree of protection
    RT II
  • Mechanical durability (at no load)
    10 000 000 operations
  • Net Height (mm)
    15.7 mm
  • Rated voltage (AC)
    250Vac
  • Control Voltage (DC)
    110Vdc
  • Ambient air temperature for operation
    -40...+85 °C
  • Net Depth (mm)
    12.6 mm
  • Primary brand
    Finder
  • Mounting mode
    PCB Plug-in
  • Contacts type
    2C/O / DPDT (Double Pole Double Throw)
  • Contacts coating
    AgNi (Silver Nickel)
  • Electrical durability (with load)
    60 000 operations
  • Main function
    Relay
  • Rated current
    8A (250Vac; AC-1) 8A (30Vdc; DC-1) 0.3A (110Vdc; DC-1) 0.12A (220Vdc; DC-1)
  • Rated impulse voltage (Uimp)
    6 kV
  • Product series / family name
    41 series
  • Poles
    2 Pole(s)
  • Compliant with standard(s)
    cURus RINA IMQ VDE EAC EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 EN 61810-1 EN 62314
  • Net Width (mm)
    29 mm

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.



Related documents 41.52.9.110.0010 Specs

Manufacturer warranty

$7.13

Request a quote, and we will send availability within minutes.

Select Qty:

$7.13

$7.13 each

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts

UBC10.241 on Powermatic Associates

UBC10.241

PULS UBC10.241 is an Uninterruptible Power Supply (UPS) control module within the U-series, featuring a built-in battery with a 50% power reserve and a green status LED. This module is housed in aluminium and utilizes spring-clamp connections for installation. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can reach up to 15A in buffer mode for less than 5 seconds at full output voltage. It supports DIN rail mounting and can operate in ambient air temperatures ranging from 0 to +40°C. The current consumption is 1.1A at a 24Vdc input, and it is designed for DC networks. Visual position indicators include Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. It is advised not to use the DC-UPS in parallel to increase output power, but paralleling two units for 1+1 redundancy is possible for higher system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. The efficiency is rated at 0.978 with a 24Vdc input, and the rated power is 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W with a 24Vdc input at 0A output current and 5.5W at 10A output current. Ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. The electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output.

Puls

1