5226780 Festo Programmable Logic Controllers

Festo 5226780 controller CPX-E-CEC-C1 Dimensions W x L x H: 42,2 mm x 125,8 mm x 76,5 mm, Grid dimension: 18,9 mm, CPU data: (* 512 MB RAM, * Dual Core 666 MHz), Diagnostics via LED: (* Force mode, * Network status engineering port 1, * Network status EtherCAT®, * Run,
Festo

Part#:5226780

Manufacturer:Festo

Alt. Part#:CPX-E-CEC-C1

Product Lifecycle:Active

Get a quick Quote!

controller CPX-E-CEC-C1 Dimensions W x L x H: 42,2 mm x 125,8 mm x 76,5 mm, Grid dimension: 18,9 mm, CPU data: (* 512 MB RAM, * Dual Core 666 MHz), Diagnostics via LED: (* Force mode, * Network status engineering port 1, * Network status EtherCAT®, * Run,

About the manufacturer: Festo is one of the manufacturers that offers Programmable Logic Controllers that you can order at Powermatic Associates site. Festo Corp. has been a top supplier of automation and intelligent automation solutions for more than four decades in the United States and eight decades globally. The company is committed to transforming the manufacturing sector and enhancing business efficiency.

Check out the 5226780 Festo price in the box on the right side or send a quick quote.

Product Details

  • Ethernet interface, transmission rate
    10 Mbit/s 100 Mbit/s
  • System parameter
    Diagnostic memory System start
  • Module parameters
    Channel alarm bundling Analog module process value representation
  • Nominal operating voltage DC for electronics/sensors
    24 V
  • Type code
    CPX-E
  • IP address setting
    DHCP Via CODESYS
  • Certificate issuing authority
    UL E239998
  • Corrosion resistance class (CRC)
    0 - No corrosion stress
  • Protection against direct and indirect contact
    PELV
  • Max. address capacity inputs
    64 byte
  • Vibration resistance
    Transport application test with severity level 1 as per FN 942017-4 and EN 60068-2-6
  • Note on ambient temperature
    -5 - 60 °C for vertical installation
  • Power supply, connection pattern
    00995847
  • Ethernet interface, function
    Diagnostics
  • Ethernet interface, connection type
    Socket
  • Power supply, number of pins/wires
    4
  • Width dimension
    18.9 mm
  • Additional functions
    CODESYS V3
  • Processing time
    Approx. 200 µs/1 k instruction
  • Type of mounting
    With H-rail
  • Dimensions W x L x H
    42.2 mm x 125.8 mm x 76.5 mm
  • Fieldbus interface, connection type
    Socket
  • Fieldbus interface, connection pattern
    00995789
  • Power supply, information on conductor diameter
    0.2 - 2.5 mm² for flexible conductors without cable end sleeves
  • Ethernet interface, connection pattern
    00995789
  • Power supply, connection technology
    Spring-loaded terminal
  • KC characters
    KC EMC
  • Power supply, conductor diameter
    0.2 mm² ... 1.5 mm²
  • Max. number of modules
    10
  • Control elements
    DIL switch for RUN/STOP
  • Max. power supply
    8 A
  • Power failure buffering
    20 ms
  • Relative air humidity
    95 % Non-condensing
  • Degree of protection
    IP20
  • Product weight
    145 g
  • Fieldbus interface, type
    Ethernet
  • Power supply, type of connection
    Terminal strip
  • Ethernet interface, connection technology
    RJ45
  • Power supply, function
    Electronics and sensors
  • Fieldbus interface, connection technology
    RJ45
  • Shock resistance
    Shock test with severity level 1 as per FN 942017-5 and EN 60068-2-27
  • Ethernet interface, number of poles/wires
    8
  • Buffer time real-time clock
    3 Weeks
  • Configuration support
    CODESYS V3
  • Flag
    120 kB remanent data CODESYS variable concept
  • Programming software
    CODESYS provided by Festo
  • CE marking (see declaration of conformity)
    As per EU EMC directive
  • Ambient temperature
    -5 °C ... 50 °C
  • Max. address capacity outputs
    64 byte
  • Fieldbus interface, transmission rate
    100 Mbit/s
  • Housing material
    PA
  • Ethernet interface, protocol
    EasyIP TCP/IP
  • Intrinsic current consumption at nominal operating voltage for electronics/sensors
    Typically 65 mA
  • Fieldbus interface, function
    Bus connection, forwarding
  • Permissible voltage fluctuations for electronics/sensors
    ± 25 %
  • Fieldbus interface, protocol
    EtherCAT Master
  • Diagnostics via LED
    Force mode System fault
  • Fieldbus interface, number of poles/wires
    8
  • CPU data
    512 MB RAM Dual core 666 MHz
  • Function blocks
    and others Copying of CPX-E diagnostic trace
  • Program memory
    12 MB user program
  • Storage temperature
    -20 °C ... 70 °C
  • Certification
    RCM compliance mark c UL us - Listed (OL)
  • Fieldbus interface, galvanic isolation
    yes
  • Note on materials
    Contains paint-wetting impairment substances RoHS-compliant

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.



Related documents 5226780 Specs

Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts

UBC10.241

UBC10.241

PULS UBC10.241 is an Uninterruptible Power Supply (UPS) control module within the U-series, featuring a built-in battery with a 50% power reserve and a green status LED. This module is housed in aluminium and utilizes spring-clamp connections for installation. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can reach up to 15A in buffer mode for less than 5 seconds at full output voltage. It supports DIN rail mounting and can operate in ambient air temperatures ranging from 0 to +40°C. The current consumption is 1.1A at a 24Vdc input, and it is designed for DC networks. Visual position indicators include Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. It is advised not to use the DC-UPS in parallel to increase output power, but paralleling two units for 1+1 redundancy is possible for higher system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. The efficiency is rated at 0.978 with a 24Vdc input, and the rated power is 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W with a 24Vdc input at 0A output current and 5.5W at 10A output current. Ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. The electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output.

Puls