Pilz PILZ-890160 is a protection unit designed for true power monitoring with a relay that supports 9 different measuring ranges. It features adjustable switching for underload and overload thresholds, along with customizable monitoring reaction time and start-up suppression time. This unit is suitable for DIN rail mounting and operates within an ambient air temperature range of 0 to +55°C. It has a net height of 87 mm and is designed to measure from 0 percent, with a rated current of 18A for measuring current. The safety output contacts ratings vary from 0.1A-5A at 24Vdc (DC-1; 120W) and 240Vac (AC-1; 1200VA) to 0.1A-1.5A at 24Vdc (DC-13) and 0.1A-1.8A at 230Vac (AC-15). Connection is made through fixed screw terminal connections. The supply voltage ranges from 27.5-264.5Vac for AC and 93.5-287.5Vdc for DC, accommodating various nominal voltages. It belongs to the S1WP sub-range, with dimensions of W22.5mm and a degree of protection rated at IP40. The frequency range for measurement extends up to 1kHz. Constructed with a PPO housing, it is designed for both single-phase (1AC) and 3-phase (3AC) input types, with a rated voltage for AC and DC measuring voltage up to 415Vac/dc. The unit's net width is 22.5 mm, and it consumes 5 VA of power, with a net depth of 121 mm. It can be stored in temperatures ranging from -40 to +85°C. The digital outputs include 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc 120W DC-1 or 240Vac 1200VA AC-1 resistive load), and the analog inputs comprise 1 x analog input for current measurement (K1-UL1) and 1 x analog input for voltage measurement (L1-L3). Protection functions include underpower and overpower, with 1 x analog output for voltage (U) and current (I) monitoring.
Quick Quote
Pilz PILZ-840650 is a protection unit designed for thermistor monitoring relay applications, featuring thermistor monitoring as its main function. It is engineered for DIN rail mounting and operates within an ambient air temperature range of -10 to +55°C. This unit has a net height of 87 mm and incorporates a manual reset design with fixed screw terminal connections. It is supplied with a voltage range of 93.5-121Vac (110Vac nominal) and falls under the S1MO sub-range. The dimensions include a width of 22.5mm and a depth of 121 mm, offering a degree of protection of IP40. The housing is made from PPO material, ensuring durability within specified conditions. Power consumption is rated at 3.5 VA. The operating mode is manual reset in a normally energized configuration. For storage, it can withstand ambient air temperatures from -40 to +85°C. It includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) for digital outputs and 2 x analog inputs (T1-T2 measuring circuits) for monitoring purposes. Additionally, it features 2 x reset circuit inputs (X2-X1) for digital inputs and is equipped with protection functions against overheating, utilizing thermistor-based technology.
Quick Quote
Pilz PILZ-840415 is a protection unit designed for thermistor monitoring relay applications, featuring DIN rail mounting for easy installation. It operates within an ambient air temperature range of -10 to +55°C and has a net height of 87 mm with fixed screw terminal connections. This unit is supplied with a voltage range of 204-264Vac (240Vac nominal) and falls under the S1MN sub-range. It measures 22.5mm in width, has a degree of protection of IP40, and is constructed with a PPO housing. The power consumption is rated at 3.5 VA, and its dimensions include a net width of 22.5 mm and a net depth of 121 mm. It supports both automatic and manual reset operating modes in a normally energized configuration. The ambient air temperature for storage is specified from -40 to +85°C. It features 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) (12-14-11; 22-24-21) for digital outputs, 2 x analog inputs (T1-T2 measuring circuits), and includes protection functions for overheating (Thermistor). Additionally, it has 2 x reset circuit inputs (X2-X1) for digital inputs and boasts a mechanical durability of 10,000,000 operations at no load.
Quick Quote
Pilz PILZ-827240 is a protection unit designed for single-phase voltage monitoring with DIN rail mounting. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. The design ensures that measuring inputs are not polarity-sensitive. It features safety output contacts ratings of 0.1A-5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15), with fixed screw terminal connections. The supply voltage is between 35.7-52.8Vac (42Vac / 48Vac nominal) under the sub-range name S1UM. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. The frequency measuring range is 0.4-400Hz, housed in a PPO material. It is suitable for single-phase (1AC) input networks with a rated voltage for measuring between 0.1-500Vac/dc, adjustable. The net width is 22.5 mm, and it consumes 2 VA of power with a net depth of 121 mm. Operating modes include fault latching or non-latching, normally energized mode, or normally de-energized mode. It can be stored in temperatures ranging from -40 to +85°C. The unit has 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load) and digital inputs for de-energized mode (Y1-Y2) and latching (Y3). Protection functions cover overvoltage, with a response time of 0.1-10 s.
Quick Quote
Pilz PILZ-890170 is a protection unit designed for DIN rail mounting, featuring a phase sequence monitoring relay. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. The unit offers fixed screw terminal connections and requires a supply voltage of 200Vac-240Vac (220Vac / 230Vac nominal) within the S1PN sub-range. With dimensions of W22.5mm x D121mm and a net width of 22.5 mm, it is encased in a PPO housing that provides an IP40 degree of protection. Designed for a 3-phase (3AC) input network with a rated voltage of 200-240Vac, it consumes 8 VA of power. The operating mode is normally energized, and it includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) for digital outputs and 1 x analog input for L1-L3 voltage measurement. Its protection functions include phase sequence and phase failure.
Quick Quote
Pilz PILZ-760100 is a protection unit designed for true power monitoring and measurement, with limit values that can be adjusted via a display and stored on a chip card. It supports DIN rail mounting and operates within an ambient air temperature range of -10 to +55°C. The unit has a net height of 100 mm and accommodates a rated current of 1A-12A for measuring, with safety output contacts ratings of 0.1A-5A at 24Vdc (DC-1; 120W), 0.1A-5A at 240Vac (AC-1; 1200VA), 2A at 24Vdc (DC-13), and 5A at 230Vac (AC-15). Connection is facilitated through plug-in/detachable spring terminal connections. The supply voltage ranges from 19.2-264Vac, covering 24Vac, 110Vac, 120Vac, 220Vac, and 240Vac nominal values, and from 19.2-264Vdc, covering 24Vdc, 110Vdc, 120Vdc, 220Vdc, and 250Vdc nominal values. It falls under the PMD s10 sub-range, with dimensions of W45mm x D120mm, and offers an IP40 degree of protection. The housing is made of PC material, and it is suitable for both single-phase (1AC) and 3-phase (3AC) input networks, with a rated voltage of 100-550Vac/dc for measuring voltage. The net width is 45 mm, and it consumes 3 W of power. Operating modes include fault latching/non-latching, automatic/manual reset, and normally energized/de-energized modes. It can be stored in temperatures ranging from -25 to +85°C. The unit features 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts; 0.1-5A 24Vdc 120W DC-1 or 240Vac 1200VA AC-1 resistive load), 1 x analog input for single-phase or 3-phase voltage measurement, and protection functions against overpower, overcurrent, and undercurrent. It also includes a link terminal and a measuring circuit for digital inputs, and 1 x analog output for voltage and current measurement.
Quick Quote
Pilz PILZ-838000 is a protection unit designed for thermistor monitoring relay applications, featuring DIN rail mounting for easy installation. It operates within an ambient air temperature range of -10 to +55°C and has a net height of 87 mm. The unit is equipped with fixed screw terminal connections and requires a supply voltage of 340-440Vac, with 400Vac nominal. Part of the S1MN sub-range, it measures 22.5mm in width, has a degree of protection of IP40, and is housed in PPO material. The power consumption is rated at 3.5 VA, and the net depth is 121 mm. This protection unit offers both automatic and manual reset operating modes in a normally energized configuration. It can withstand ambient air temperatures for storage between -40 and +85°C. The unit includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) for digital outputs, 2 x analog inputs (T1-T2 measuring circuits), and features overheating protection. Additionally, it has 2 x reset circuit inputs for digital inputs and boasts a mechanical durability of 10 million operations at no load.
Quick Quote
Pilz PILZ-837305 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15), with fixed screw terminal connections. The supply voltage requirement is 195.5-253Vac (230Vac nominal) under the S3UM sub-range, with dimensions of W22.5mm and a degree of protection rated at IP40. It operates across a frequency range of 40-400Hz, encased in a PPO housing, and is designed for a 3-phase (3AC) input network with a 230Vac rated measuring voltage. The net width and depth are 22.5 mm and 122 mm, respectively, with a power consumption of 1.5 W. Operating modes include fault latching/non-latching and normally energized/de-energized modes, with an ambient air temperature range for storage between -40 and +85°C. It features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load; 0.5-10s time-delay selectable) for digital outputs, 1 x analog input for L1-L3 voltage measurement, and protection functions against undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. Digital inputs include 1 x automatic reset and 1 x switching commutation.
Quick Quote
Pilz PILZ-890150 is a protection unit designed for true power monitoring with a relay that supports 9 different measuring ranges. It features adjustable switching for underload and overload thresholds, along with customizable monitoring reaction time and start-up suppression time. This unit is suitable for DIN rail mounting and operates within an ambient air temperature range of 0 to +55°C. It has a net height of 87 mm and is rated for an 18A measuring current. The safety output contacts ratings vary from 0.1A to 5A at 24Vdc (DC-1; 120W) and 240Vac (AC-1; 1200VA), to 0.1A-1.5A at 24Vdc (DC-13) and 0.1A-1.8A at 230Vac (AC-15). Connection is established via fixed screw terminal connections. The supply voltage can range from 27.5-264.5Vac for AC and 93.5-287.5Vdc for DC, covering nominal voltages of 110Vac/120Vac/220Vac/230Vac and 110Vdc/120Vdc/220Vdc/250Vdc respectively. The S1WP sub-range model has dimensions of W22.5mm, with a degree of protection rated at IP40. It can handle a frequency measuring range of 0-1kHz and is constructed with a PPO housing. This unit is designed for both single-phase (1AC) and 3-phase (3AC) input networks, with a rated voltage for AC measuring voltage up to 415Vac/dc. The net width and depth are 22.5 mm and 121 mm, respectively, with a power consumption of 5 VA. It is capable of storage in ambient air temperatures ranging from -40 to +85°C. The digital outputs include 1 x auxiliary output (SPDT-NO/NC contacts) suitable for resistive loads, and it features 1 x analog input for current measurement and 1 x analog input for voltage measurement. The protection functions include underpower and overpower monitoring, complemented by 1 x analog output for voltage and current monitoring.
Quick Quote
Pilz PILZ-890120 is a protection unit designed for true power monitoring with a relay that supports 9 different measuring ranges. It features adjustable switching for underload and overload thresholds, along with customizable monitoring reaction time and start-up suppression time. This unit is suitable for DIN rail mounting and operates within an ambient air temperature range of 0 to +55°C. It has a net height of 87 mm and is rated for an 18A measuring current. The safety output contacts ratings vary from 0.1A to 5A at 24Vdc (DC-1; 120W) and 240Vac (AC-1; 1200VA), with lower ratings for DC-13 and AC-15 applications. Connection is established via fixed screw terminal connections. The supply voltage can range from 27.5-264.5Vac for AC and 93.5-287.5Vdc for DC, covering standard nominal voltages. The S1WP sub-range model has dimensions of W22.5mm, a degree of protection of IP40, and operates within a frequency of 0-1kHz for its measuring range. Constructed with a PPO housing, it is designed for both single-phase (1AC) and 3-phase (3AC) input networks, with a rated voltage of 0-120Vac/dc for measuring voltage. The unit's net width and depth are 22.5 mm and 121 mm, respectively, and it has a power consumption of 5 VA. It can be stored in temperatures ranging from -40 to +85°C. The digital outputs include 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc 120W DC-1 or 240Vac 1200VA AC-1 resistive load), and it features 1 x analog input for current measurement and 1 x analog input for voltage measurement. Protection functions include underpower and overpower monitoring, complemented by 1 x analog output for voltage and current monitoring.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
PILZ-890160 Pilz PILZ-890160 is a protection unit designed for true power monitoring with a relay that supports 9 different measuring ranges. It features adjustable switching for underload and overload thresholds, along with customizable monitoring reaction time and start-up suppression time. This unit is suitable for DIN rail mounting and operates within an ambient air temperature range of 0 to +55°C. It has a net height of 87 mm and is designed to measure from 0 percent, with a rated current of 18A for measuring current. The safety output contacts ratings vary from 0.1A-5A at 24Vdc (DC-1; 120W) and 240Vac (AC-1; 1200VA) to 0.1A-1.5A at 24Vdc (DC-13) and 0.1A-1.8A at 230Vac (AC-15). Connection is made through fixed screw terminal connections. The supply voltage ranges from 27.5-264.5Vac for AC and 93.5-287.5Vdc for DC, accommodating various nominal voltages. It belongs to the S1WP sub-range, with dimensions of W22.5mm and a degree of protection rated at IP40. The frequency range for measurement extends up to 1kHz. Constructed with a PPO housing, it is designed for both single-phase (1AC) and 3-phase (3AC) input types, with a rated voltage for AC and DC measuring voltage up to 415Vac/dc. The unit's net width is 22.5 mm, and it consumes 5 VA of power, with a net depth of 121 mm. It can be stored in temperatures ranging from -40 to +85°C. The digital outputs include 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc 120W DC-1 or 240Vac 1200VA AC-1 resistive load), and the analog inputs comprise 1 x analog input for current measurement (K1-UL1) and 1 x analog input for voltage measurement (L1-L3). Protection functions include underpower and overpower, with 1 x analog output for voltage (U) and current (I) monitoring. | Pilz | Quick Quote | |||
PILZ-840650 Pilz PILZ-840650 is a protection unit designed for thermistor monitoring relay applications, featuring thermistor monitoring as its main function. It is engineered for DIN rail mounting and operates within an ambient air temperature range of -10 to +55°C. This unit has a net height of 87 mm and incorporates a manual reset design with fixed screw terminal connections. It is supplied with a voltage range of 93.5-121Vac (110Vac nominal) and falls under the S1MO sub-range. The dimensions include a width of 22.5mm and a depth of 121 mm, offering a degree of protection of IP40. The housing is made from PPO material, ensuring durability within specified conditions. Power consumption is rated at 3.5 VA. The operating mode is manual reset in a normally energized configuration. For storage, it can withstand ambient air temperatures from -40 to +85°C. It includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) for digital outputs and 2 x analog inputs (T1-T2 measuring circuits) for monitoring purposes. Additionally, it features 2 x reset circuit inputs (X2-X1) for digital inputs and is equipped with protection functions against overheating, utilizing thermistor-based technology. | Pilz | Quick Quote | |||
PILZ-840415 Pilz PILZ-840415 is a protection unit designed for thermistor monitoring relay applications, featuring DIN rail mounting for easy installation. It operates within an ambient air temperature range of -10 to +55°C and has a net height of 87 mm with fixed screw terminal connections. This unit is supplied with a voltage range of 204-264Vac (240Vac nominal) and falls under the S1MN sub-range. It measures 22.5mm in width, has a degree of protection of IP40, and is constructed with a PPO housing. The power consumption is rated at 3.5 VA, and its dimensions include a net width of 22.5 mm and a net depth of 121 mm. It supports both automatic and manual reset operating modes in a normally energized configuration. The ambient air temperature for storage is specified from -40 to +85°C. It features 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) (12-14-11; 22-24-21) for digital outputs, 2 x analog inputs (T1-T2 measuring circuits), and includes protection functions for overheating (Thermistor). Additionally, it has 2 x reset circuit inputs (X2-X1) for digital inputs and boasts a mechanical durability of 10,000,000 operations at no load. | Pilz | Quick Quote | |||
PILZ-827240 Pilz PILZ-827240 is a protection unit designed for single-phase voltage monitoring with DIN rail mounting. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. The design ensures that measuring inputs are not polarity-sensitive. It features safety output contacts ratings of 0.1A-5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15), with fixed screw terminal connections. The supply voltage is between 35.7-52.8Vac (42Vac / 48Vac nominal) under the sub-range name S1UM. Dimensions include a width of 22.5mm and a degree of protection rated at IP40. The frequency measuring range is 0.4-400Hz, housed in a PPO material. It is suitable for single-phase (1AC) input networks with a rated voltage for measuring between 0.1-500Vac/dc, adjustable. The net width is 22.5 mm, and it consumes 2 VA of power with a net depth of 121 mm. Operating modes include fault latching or non-latching, normally energized mode, or normally de-energized mode. It can be stored in temperatures ranging from -40 to +85°C. The unit has 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load) and digital inputs for de-energized mode (Y1-Y2) and latching (Y3). Protection functions cover overvoltage, with a response time of 0.1-10 s. | Pilz | Quick Quote | |||
PILZ-890170 Pilz PILZ-890170 is a protection unit designed for DIN rail mounting, featuring a phase sequence monitoring relay. It operates within an ambient air temperature range of -15 to +55°C and has a net height of 87 mm. The unit offers fixed screw terminal connections and requires a supply voltage of 200Vac-240Vac (220Vac / 230Vac nominal) within the S1PN sub-range. With dimensions of W22.5mm x D121mm and a net width of 22.5 mm, it is encased in a PPO housing that provides an IP40 degree of protection. Designed for a 3-phase (3AC) input network with a rated voltage of 200-240Vac, it consumes 8 VA of power. The operating mode is normally energized, and it includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) for digital outputs and 1 x analog input for L1-L3 voltage measurement. Its protection functions include phase sequence and phase failure. | Pilz | Quick Quote | |||
PILZ-760100 Pilz PILZ-760100 is a protection unit designed for true power monitoring and measurement, with limit values that can be adjusted via a display and stored on a chip card. It supports DIN rail mounting and operates within an ambient air temperature range of -10 to +55°C. The unit has a net height of 100 mm and accommodates a rated current of 1A-12A for measuring, with safety output contacts ratings of 0.1A-5A at 24Vdc (DC-1; 120W), 0.1A-5A at 240Vac (AC-1; 1200VA), 2A at 24Vdc (DC-13), and 5A at 230Vac (AC-15). Connection is facilitated through plug-in/detachable spring terminal connections. The supply voltage ranges from 19.2-264Vac, covering 24Vac, 110Vac, 120Vac, 220Vac, and 240Vac nominal values, and from 19.2-264Vdc, covering 24Vdc, 110Vdc, 120Vdc, 220Vdc, and 250Vdc nominal values. It falls under the PMD s10 sub-range, with dimensions of W45mm x D120mm, and offers an IP40 degree of protection. The housing is made of PC material, and it is suitable for both single-phase (1AC) and 3-phase (3AC) input networks, with a rated voltage of 100-550Vac/dc for measuring voltage. The net width is 45 mm, and it consumes 3 W of power. Operating modes include fault latching/non-latching, automatic/manual reset, and normally energized/de-energized modes. It can be stored in temperatures ranging from -25 to +85°C. The unit features 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts; 0.1-5A 24Vdc 120W DC-1 or 240Vac 1200VA AC-1 resistive load), 1 x analog input for single-phase or 3-phase voltage measurement, and protection functions against overpower, overcurrent, and undercurrent. It also includes a link terminal and a measuring circuit for digital inputs, and 1 x analog output for voltage and current measurement. | Pilz | Quick Quote | |||
PILZ-838000 Pilz PILZ-838000 is a protection unit designed for thermistor monitoring relay applications, featuring DIN rail mounting for easy installation. It operates within an ambient air temperature range of -10 to +55°C and has a net height of 87 mm. The unit is equipped with fixed screw terminal connections and requires a supply voltage of 340-440Vac, with 400Vac nominal. Part of the S1MN sub-range, it measures 22.5mm in width, has a degree of protection of IP40, and is housed in PPO material. The power consumption is rated at 3.5 VA, and the net depth is 121 mm. This protection unit offers both automatic and manual reset operating modes in a normally energized configuration. It can withstand ambient air temperatures for storage between -40 and +85°C. The unit includes 2 x auxiliary outputs (2CO changeover / 2xSPDT-NO/NC contacts) for digital outputs, 2 x analog inputs (T1-T2 measuring circuits), and features overheating protection. Additionally, it has 2 x reset circuit inputs for digital inputs and boasts a mechanical durability of 10 million operations at no load. | Pilz | Quick Quote | |||
PILZ-837305 Pilz PILZ-837305 is a protection unit designed for 3-phase voltage monitoring, including overvoltage and undervoltage monitoring functions. It is suitable for DIN rail mounting and operates within an ambient air temperature range of -15 to +55°C. The unit has a net height of 87 mm and supports safety output contacts ratings from 0.1A to 5A at 240Vac (AC-1; 1200VA) and 2A at 230Vac (AC-15), with fixed screw terminal connections. The supply voltage requirement is 195.5-253Vac (230Vac nominal) under the S3UM sub-range, with dimensions of W22.5mm and a degree of protection rated at IP40. It operates across a frequency range of 40-400Hz, encased in a PPO housing, and is designed for a 3-phase (3AC) input network with a 230Vac rated measuring voltage. The net width and depth are 22.5 mm and 122 mm, respectively, with a power consumption of 1.5 W. Operating modes include fault latching/non-latching and normally energized/de-energized modes, with an ambient air temperature range for storage between -40 and +85°C. It features 1 x delayed auxiliary output (SPDT-NO/NC contacts; 0.1-5A 240Vac AC-1 resistive load; 0.5-10s time-delay selectable) for digital outputs, 1 x analog input for L1-L3 voltage measurement, and protection functions against undervoltage, overvoltage, phase sequence, phase failure, and asymmetry. Digital inputs include 1 x automatic reset and 1 x switching commutation. | Pilz | Quick Quote | |||
PILZ-890150 Pilz PILZ-890150 is a protection unit designed for true power monitoring with a relay that supports 9 different measuring ranges. It features adjustable switching for underload and overload thresholds, along with customizable monitoring reaction time and start-up suppression time. This unit is suitable for DIN rail mounting and operates within an ambient air temperature range of 0 to +55°C. It has a net height of 87 mm and is rated for an 18A measuring current. The safety output contacts ratings vary from 0.1A to 5A at 24Vdc (DC-1; 120W) and 240Vac (AC-1; 1200VA), to 0.1A-1.5A at 24Vdc (DC-13) and 0.1A-1.8A at 230Vac (AC-15). Connection is established via fixed screw terminal connections. The supply voltage can range from 27.5-264.5Vac for AC and 93.5-287.5Vdc for DC, covering nominal voltages of 110Vac/120Vac/220Vac/230Vac and 110Vdc/120Vdc/220Vdc/250Vdc respectively. The S1WP sub-range model has dimensions of W22.5mm, with a degree of protection rated at IP40. It can handle a frequency measuring range of 0-1kHz and is constructed with a PPO housing. This unit is designed for both single-phase (1AC) and 3-phase (3AC) input networks, with a rated voltage for AC measuring voltage up to 415Vac/dc. The net width and depth are 22.5 mm and 121 mm, respectively, with a power consumption of 5 VA. It is capable of storage in ambient air temperatures ranging from -40 to +85°C. The digital outputs include 1 x auxiliary output (SPDT-NO/NC contacts) suitable for resistive loads, and it features 1 x analog input for current measurement and 1 x analog input for voltage measurement. The protection functions include underpower and overpower monitoring, complemented by 1 x analog output for voltage and current monitoring. | Pilz | Quick Quote | |||
PILZ-890120 Pilz PILZ-890120 is a protection unit designed for true power monitoring with a relay that supports 9 different measuring ranges. It features adjustable switching for underload and overload thresholds, along with customizable monitoring reaction time and start-up suppression time. This unit is suitable for DIN rail mounting and operates within an ambient air temperature range of 0 to +55°C. It has a net height of 87 mm and is rated for an 18A measuring current. The safety output contacts ratings vary from 0.1A to 5A at 24Vdc (DC-1; 120W) and 240Vac (AC-1; 1200VA), with lower ratings for DC-13 and AC-15 applications. Connection is established via fixed screw terminal connections. The supply voltage can range from 27.5-264.5Vac for AC and 93.5-287.5Vdc for DC, covering standard nominal voltages. The S1WP sub-range model has dimensions of W22.5mm, a degree of protection of IP40, and operates within a frequency of 0-1kHz for its measuring range. Constructed with a PPO housing, it is designed for both single-phase (1AC) and 3-phase (3AC) input networks, with a rated voltage of 0-120Vac/dc for measuring voltage. The unit's net width and depth are 22.5 mm and 121 mm, respectively, and it has a power consumption of 5 VA. It can be stored in temperatures ranging from -40 to +85°C. The digital outputs include 1 x auxiliary output (SPDT-NO/NC contacts; 0.1-5A 24Vdc 120W DC-1 or 240Vac 1200VA AC-1 resistive load), and it features 1 x analog input for current measurement and 1 x analog input for voltage measurement. Protection functions include underpower and overpower monitoring, complemented by 1 x analog output for voltage and current monitoring. | Pilz | Quick Quote |