| SLA3.100 PULS SLA3.100 is a power supply unit designed with NEC Class 2 and ATEX approval, compliant with EN 61000-3-2 PFC norm, featuring a DC-OK relay contact output. It serves as an AS-Interface power supply unit (PSU) encased in a robust metal housing. This unit offers screw-clamp connections for secure installation and measures W49mm x H124mm x D102mm. It supports a wide range of supply voltages, including AC options from 85Vac to 264Vac and a DC option from 230Vdc to 375Vdc, with a rated current of 2.8A at 30.6Vdc. Designed for DIN rail mounting, it operates within an ambient air temperature range of -10 to +70 °C. The SLA3.100 experiences a peak inrush current consumption of 49.7A at 230Vac input and 44.7A at 120Vac input. It is suitable for single-phase (1AC) or DC networks and includes protection functions such as output overvoltage protection (up to 55Vdc max.), NTC for input inrush current limiting, and overload/short-circuit protection. The output voltage is fixed at 30.6Vdc, with an efficiency of 0.905 at 230Vac input, a hold time of 26ms at 100Vac input, power dissipation/losses of 9.1W at full output load, and a ripple of 50mVpp across 20Hz to 20MHz at 50Ω. | Puls | $645.00 | |
| SLAD4.100 PULS SLAD4.100 is a power supply unit designed with a PFC compliant to EN 61000-3-2 standards, featuring a DC-OK relay contact output. It serves as an AS-Interface power supply unit (PSU) and DC/DC-Converter, encased in a robust metal housing. This unit offers screw-clamp connections for secure installation and measures W40mm x H124mm x D102mm. It operates on a supply voltage range of 18Vdc-31.4Vdc, with a nominal 24Vdc, and delivers a rated current of 4A at 30.6Vdc, incorporating a derating curve from 3W/+60°C to +70°C. Designed for DIN rail mounting, it can function within an ambient air temperature range of -25°C to +70°C. The SLAD4.100 has a net width of 40 mm and a peak inrush current consumption of 1.8A. It is compatible with DC networks only and includes protection functions against output overvoltage (up to 36Vdc max.), with an active input inrush current limiter, and overload/short-circuit conditions (min. 5A/max. 12A current). Series or parallel operation is not supported. The output voltage is fixed at 30.6Vdc, with an efficiency of 0.905 at 24Vdc input. Power dissipation/losses are 12.7W at 24Vdc input with full output load. The unit features a 650ms start-up delay, a 100ms rise time under nominal input with constant full current load and 0mF load capacitance, and a 200ms rise time with 5mF load capacitance. Ripple is maintained at 50mVpp across a frequency range of 20Hz to 20MHz at 50Ω. | Puls | $875.00 | |
| | Puls | $350.00 | |
| CP20.481 PULS CP20.481 is a power supply unit designed for DIN rail mounting with an aluminium housing. It operates within an ambient air temperature range of -25 to +70°C and has a net width of 48mm. The unit features a current consumption of 5.5A peak max. inrush at 230Vac input and 12A peak max. inrush at 120Vac input. Its efficiency rates are 0.963 at 230Vac input, 0.95 at 120Vac input, and 0.944 at 100Vac input. The dimensions of the CP20.481 are W48mm x H124mm x D127mm. It has a 450ms start-up delay and a rise time of 120ms under nominal input with a constant full current load and 0mF load capacitance, and 170ms with 10mF load capacitance. The unit includes protection functions such as output overvoltage protection and overload/short-circuit protection, with the capability for series or parallel operation for increased output voltages or power. It is resistant to back-feeding loads up to 63V. Power dissipation/losses are 18.4W at 230Vac input and 25.1W at 120Vac input with full output load. The output stage capacitance is 2500µF. Electrical durability varies with conditions, reaching up to 509000 hours at 25°C and 5A output with 1AC 230Vac input. The ripple is 50mVpp (20Hz...20MHz; 50Ω). This AC/DC power supply unit offers a 20% power reserve and includes a DC-OK relay contact output. It features screw-clamp connections and supports a supply voltage range of 88Vdc-180Vdc and 85Vac-264Vac, with a rated current of 10A at 48Vdc, and a rated power of 480W. The output voltage is adjustable between 48Vdc and 56Vdc, with a 500mV turn-ON overshoot and a hold time of 32ms at 120/230Vac input. It is suitable for single-phase (1AC) or DC networks. | Puls | $550.00 | |
| CP20.241-R2-C1 PULS CP20.241-R2-C1 is a DIN rail mounting power supply unit with an aluminium housing designed for a wide range of industrial applications. It operates within an ambient air temperature range of -40 to +70°C and has a net width of 48 mm. The unit consumes current differently based on the input, including 2.25A with 230Vac input, 4.28A with 120Vac input, 5.17A with 100Vac input, and 4.64A with 110Vdc input for a 24Vdc / 10A output, with peak inrush currents of 5.5A and 12A for 230Vac and 120Vac inputs respectively. It features an IP20 degree of protection and achieves efficiencies of 0.952 and 0.938 with 230Vac and 120Vac inputs, respectively. The power supply is resistant to harsh environments, thanks to its conformal coated PCB, and has dimensions of W48mm x H124mm x D127mm. It includes a 450ms start-up delay and rise times of 145ms and 160ms under specified conditions. Protection functions include output overvoltage protection and overload/short-circuit protection, with capabilities for series/parallel operation and resistance to back-feeding loads up to 35V. Power dissipation losses are 24.2W and 31.7W for 230Vac and 120Vac inputs, respectively, with an output stage capacitance of 8000 µF. Electrical durability varies with conditions, offering up to 465,000 hours at 25°C with a 10A output and 1AC 230Vac input. The ripple is specified as 100mVpp. This AC/DC power supply unit, part of the CP-series, is designed with built-in decoupling MOSFET for redundancy, hot-swappable connectors, ATEX approval, and a 20% power reserve. It supports a supply voltage range of 88Vdc-180Vdc for DC and 85Vac-264Vac for AC, with specific shutdown and turn-on voltages. The rated current is 24A at 48Vdc in temperatures up to +45°C, with derating at higher temperatures. It provides a fixed 24Vdc output voltage and includes a 32ms hold time at standard AC inputs. | Puls | $825.00 | |
| CS10.243 PULS CS10.243 is a DIN rail mounting power supply unit with an aluminium housing designed for a single-phase network. It operates within an ambient air temperature range of 0 to +70°C and has a net width of 60mm. The unit consumes 3.71A with a 120Vac input and 4.32A with a 100Vac input for a full 24Vdc output, featuring a peak inrush current of 108A at 120Vac input and 90A at 100Vac input. It offers an efficiency of 0.913 at 120Vac input and 0.91 at 100Vac input. The dimensions are W60mm x H124mm x D117mm. It includes a 250ms start-up delay for 100-120Vac input, with a rise time of 35ms under nominal input at constant full current load with 0mF load capacitance and 75ms with 10mF load capacitance. The power supply unit is equipped with protection functions including output overvoltage protection, NTC for input inrush current limiting, and overload/short-circuit protection. It supports series/parallel operation for redundancy and is resistant to back-feeding loads up to 35V. Power dissipation/losses are 22.9W at 120Vac input with full output load, and the output stage capacitance is 7000µF. Electrical durability ranges from 27,000 to 281,000 hours depending on conditions. Ripple is maintained at 50mVpp across a 20Hz to 20MHz range. This AC/DC power supply unit, part of the C-Line series, features a 20% power reserve, DC-OK relay contact output, and screw-clamp connections. It accepts a supply voltage of 90Vac-132Vac (47-63Hz) with a turn-ON voltage of 82Vac and a shutdown voltage of 78Vac in steady-state. The rated current is 12A at 24Vdc for ambient temperatures less than 45°C and 10A at 24Vdc for less than 60°C, with an adjustable output voltage of 24Vdc-28Vdc. The hold time is 46ms at 120Vac input. | Puls | $355.00 | |
| CP20.241-S1 PULS CP20.241-S1 is a power supply unit designed for DIN rail mounting with an aluminium housing. It features a net width of 48 mm and operates within an ambient air temperature range of -25 to +70°C. The unit has a current consumption of 11A peak max. inrush at 230Vac input and 7A peak max. inrush at 120Vac input. Its efficiency rates are 0.956 at 230Vac input, 0.942 at 120Vac input, and 0.936 at 100Vac input. The dimensions of the CP20.241-S1 are W48mm x H124mm x D127mm. It includes a 450ms start-up delay and a rise time of 145ms to 160ms under nominal input conditions. The unit is equipped with protection functions including output overvoltage protection and overload/short-circuit current protection. It supports series and parallel operation for increased output voltages or power, and 1+1 redundancy with a redundancy module. The power dissipation/losses are 22.1 W at 230Vac input and 29.6 W at 120Vac input, with an output stage capacitance of 8500 µF. Its electrical durability ranges from 31,000 to 488,000 hours depending on the operating conditions. The ripple is 50mVpp, and it functions as an AC/DC power supply unit with a 20% power reserve. The CP-series unit has ATEX approval, a DC-OK relay contact output, and spring-clamp connections. The supply voltage ranges from 88Vdc-180Vdc for DC and 85Vac-264Vac for AC, with a rated current of 20A at 24Vdc. It is suitable for single-phase (1AC) or DC networks, has a rated power of 480W, and an adjustable output voltage of 24Vdc-28Vdc. The hold time is 32ms at 120/230Vac input. | Puls | $540.00 | |
| QS40.481 PULS QS40.481 is a power supply unit designed for DIN rail mounting, featuring AC/DC conversion with a 50% power reserve. It operates within an ambient air temperature range of -25 to +70°C and is equipped with ATEX approval, a DC-OK relay contact output, and screw-clamp connections. This unit supports a supply voltage range of 85Vac-264Vac across various nominal voltages and frequencies, with specific turn-ON and shutdown voltages. It belongs to the Q-series and is housed in an aluminium casing with dimensions of W125mm x H124mm x D127mm. The QS40.481 is designed for single-phase networks, offering a rated current of 20A at 48Vdc and 17.8A at 54Vdc, with a derating power of 24W at temperatures ranging from +60°C to +70°C. Its rated power is 960W, with a short-term capacity of 1440W for up to 4 seconds, and an adjustable output voltage between 48Vdc and 54Vdc. Protection features include output overvoltage protection and overload/short-circuit protection, with capabilities for series or parallel operation to increase output power. The unit demonstrates high efficiency rates across various input voltages and has specific inrush current, time delay, hold time, power dissipation/losses, and electrical durability metrics. It also features a ripple of 150mVpp and an output stage capacitance of 3700µF. | Puls | $1,265.00 | |
| PIM60.245 PULS PIM60.245 is a power supply unit that functions as an AC/DC PSU/converter with DIN rail mounting. It operates within an ambient air temperature range of -10 to +60°C with linear derating up to +70°C. The design includes a NEC Class 2 DC-OK relay contact output. It provides a rated current of 5A at 12Vdc from -10 to +60°C and 3.8A at 12Vdc at +70°C, utilizing screw-clamp connections. The supply voltage (AC) ranges from 90Vac to 264Vac for various nominal voltages and frequencies, with specific input overvoltage and turn-on/shutdown voltages detailed. Part of the PIM-series, it measures W36mm x H90mm x D91mm and has an IP20 degree of protection with a polycarbonate (PC) housing. Designed for single-phase networks, it offers a rated power of 60W at -10 to +60°C and 45.6W at +70°C, with an adjustable DC output voltage of 12Vdc to 15Vdc. Protection functions include output overvoltage and overload/short-circuit current protection, with specific resistance and current values provided. The unit is resistant to back-feeding loads up to 16V. Efficiency rates are noted for 230Vac and 120Vac inputs, alongside current consumption details for various input voltages and inrush current peaks. Time delay for start-up and rise, hold time, power dissipation/losses, and electrical durability at different conditions and temperatures are specified. Ripple and capacitance values are also provided, highlighting the unit's electrical characteristics. | Puls | $105.00 | |
| QT40.241 PULS QT40.241 is a power supply unit designed for AC/DC conversion with a 50% power reserve. It supports DIN rail mounting and operates within an ambient air temperature range of -25 to +70°C. This unit features a DC-OK relay contact output and offers rated currents of 40A at 24Vdc and 34.3A at 28Vdc, with a power derating from 24W at +60°C to +70°C. Connection is facilitated through screw-clamp connections. The supply voltage accommodates a wide range of AC inputs from 323Vac to 576Vac, including nominal values of 380Vac, 400Vac, 415Vac, 440Vac, 480Vac, 500Vac, and 525Vac at 47-63Hz, with a 3-phase input. It has a turn-ON voltage of 3 x 305Vac and a shutdown voltage of 3 x 275Vac in steady-state conditions. The QT40.241, part of the Q-series, measures 110mm in width, 124mm in height, and 127mm in depth, and is housed in aluminium. It is designed for a 3-phase network, with a net width of 110mm. The rated power is 960W at both 24Vdc and 28Vdc, with a short-term capacity of 1440W for up to 4 seconds. The output voltage is adjustable between 24Vdc and 28Vdc, with a turn-ON overshoot of 500mV. Protection functions include output overvoltage protection, active input inrush current limiting, and overload/short-circuit protection. It supports series or parallel operation for increased output power and is resistant to back-feeding loads up to 35V. The efficiency rates are 0.952 and 0.953 for 3x480Vac and 3x400Vac inputs, respectively. Peak inrush current consumption is 6A for both 3x400Vac and 3x480Vac inputs. The start-up delay ranges from 500 to 600 seconds, with rise times of 35ms and 40ms under nominal input conditions. The hold time is 25ms for both 3x480Vac and 3x400Vac inputs. Power dissipation losses are 48.4W and 47.3W for 3x480Vac and 3x400Vac inputs, respectively, at full output load. Electrical durability varies with temperature and load conditions, offering up to 322,000 hours of operation at 25°C and 20A output under 3AC 400Vac input. The ripple is 100mVpp across a 20Hz to 20MHz range, with an output stage capacitance of 10200µF. | Puls | $910.00 | |