Analog Signal Isolator, 1-channel, Operating voltage 10…30 VDC, Input circuit monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable screw terminals, ATEX, IECEx, cULus, Use in zone 2, SIL 2
Quick Quote
Isolating switching amplifier, 1-channel, , 2 transistor outputs, short-circuit proof, potential-free and reverse-polarity protected, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), SIL 2, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, UL, C, FM, US, CSA, TR CU, NEPSI, KOSHA, TIIS, CCOE, INMETRO, Installation in zone 2
Quick Quote
Analog signal isolator, 1-channel, , Transmission of normalized analog signals from the Ex area to the non-Ex area, Input circuit: 0/2…10 V or 0/4…20 mA, Output circuit: 0/4…20 mA, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, UL, C, FM, US, TR CU, NEPSI, KOSHA, Installation in zone 2
Quick Quote
Analog signal isolator, 1-channel, , Transmission of normalized analog signals from the Ex area to the non-Ex area, Input circuit: 0/2…10 V or 0/4…20 mA, Output circuit: 2 x 0/4 0…20 mA, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, UL, C, FM, US, TR CU, NEPSI, KOSHA, Installation in zone 2
Quick Quote
Temperature measuring amplifier, 2-channel, , Input circuits monitored for wire-break and short-circuit, Parameterized via PC, Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, ATEX, IECEx, cFM,cUL, NEPSI, INMETRO, Kosha, TR CU EAC CMI, Installation in zone 2, SIL 2
Quick Quote
Solenoid Driver, 2-channel, , Output circuits monitored for wire-break and short-circuit, , Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX, IECEx, cUL, cFM, INMETRO, NEPSI, Kosha, TR CU EAC, TIIS, Installation in zone 2, SIL 2
Quick Quote
Coupling Relay, 1-channel, , The inputs are not polarized, Input E1 activates both outputs simultaneously, NE load connection: SIL 3 Safety Function for NE (Normally Energized) load (de-energized in safe state) is available, ND load connection: SIL 3 Safety Function for ND (Normally De-Energized) load (energized in safe state) is available, Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, ATEX use in Zone 2, SIL 3
Quick Quote
Relay coupler, 1-channel, , Output circuit: 2 relays each with 1 changeover contact, 5 A switching current at 250 VAC, Operating voltage 19…29 VDC, Removable terminal blocks, SIL3, , Galvanic isolation between input circuits and output circuits, TR CU
Quick Quote
Rotation speed monitor, 1-channel, , Monitoring of limit values and ranges according to over/underrange, Operating range 0.06 … 600000 min, -1, Connection of sensors acc. to EN 60947‐5‐6 (NAMUR), 3-wire sensors and external power supplies, Pulse output, Parameterized via PC (FDT/DTM), front-panel switch and HART, Ring buffer for up to 8000 measured values, Display, Complete galvanic isolation, Input reverse-polarity protected, TR CU
Quick Quote
Temperature measuring amplifier, 1-channel, , Input for Pt100/ Ni100 resistors, thermocouples and millivolt signals in 2, 3 or 4-wire technology, Output circuit: 0/4…20 mA, Upper and lower limit adjustable via rotary coding switch, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, C, FM, US, UL, TR CU, INMETRO, CCOE, NEPSI, KOSHA, Installation in zone 2
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
IMXK12-AO01-1I-1I-H0/24VDC Analog Signal Isolator, 1-channel, Operating voltage 10…30 VDC, Input circuit monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable screw terminals, ATEX, IECEx, cULus, Use in zone 2, SIL 2 | Turck | Quick Quote | |||
IM1-12EX-T Isolating switching amplifier, 1-channel, , 2 transistor outputs, short-circuit proof, potential-free and reverse-polarity protected, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), SIL 2, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, UL, C, FM, US, CSA, TR CU, NEPSI, KOSHA, TIIS, CCOE, INMETRO, Installation in zone 2 | Turck | Quick Quote | |||
IM31-11EX-I Analog signal isolator, 1-channel, , Transmission of normalized analog signals from the Ex area to the non-Ex area, Input circuit: 0/2…10 V or 0/4…20 mA, Output circuit: 0/4…20 mA, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, UL, C, FM, US, TR CU, NEPSI, KOSHA, Installation in zone 2 | Turck | Quick Quote | |||
IM31-12EX-I Analog signal isolator, 1-channel, , Transmission of normalized analog signals from the Ex area to the non-Ex area, Input circuit: 0/2…10 V or 0/4…20 mA, Output circuit: 2 x 0/4 0…20 mA, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, UL, C, FM, US, TR CU, NEPSI, KOSHA, Installation in zone 2 | Turck | Quick Quote | |||
IMX12-TI01-2RTDR-2I-C0/24VDC Temperature measuring amplifier, 2-channel, , Input circuits monitored for wire-break and short-circuit, Parameterized via PC, Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, ATEX, IECEx, cFM,cUL, NEPSI, INMETRO, Kosha, TR CU EAC CMI, Installation in zone 2, SIL 2 | Turck | Quick Quote | |||
IMX12-DO01-2U-2U-PR/24VDC/CC Solenoid Driver, 2-channel, , Output circuits monitored for wire-break and short-circuit, , Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX, IECEx, cUL, cFM, INMETRO, NEPSI, Kosha, TR CU EAC, TIIS, Installation in zone 2, SIL 2 | Turck | Quick Quote | |||
IM12-CD01-2R-1U-0/L Coupling Relay, 1-channel, , The inputs are not polarized, Input E1 activates both outputs simultaneously, NE load connection: SIL 3 Safety Function for NE (Normally Energized) load (de-energized in safe state) is available, ND load connection: SIL 3 Safety Function for ND (Normally De-Energized) load (energized in safe state) is available, Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, ATEX use in Zone 2, SIL 3 | Turck | Quick Quote | |||
IM73-12-R/24VUC Relay coupler, 1-channel, , Output circuit: 2 relays each with 1 changeover contact, 5 A switching current at 250 VAC, Operating voltage 19…29 VDC, Removable terminal blocks, SIL3, , Galvanic isolation between input circuits and output circuits, TR CU | Turck | Quick Quote | |||
IM21-14-CDTRI Rotation speed monitor, 1-channel, , Monitoring of limit values and ranges according to over/underrange, Operating range 0.06 … 600000 min, -1, Connection of sensors acc. to EN 60947‐5‐6 (NAMUR), 3-wire sensors and external power supplies, Pulse output, Parameterized via PC (FDT/DTM), front-panel switch and HART, Ring buffer for up to 8000 measured values, Display, Complete galvanic isolation, Input reverse-polarity protected, TR CU | Turck | Quick Quote | |||
IM34-11EX-I Temperature measuring amplifier, 1-channel, , Input for Pt100/ Ni100 resistors, thermocouples and millivolt signals in 2, 3 or 4-wire technology, Output circuit: 0/4…20 mA, Upper and lower limit adjustable via rotary coding switch, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, C, FM, US, UL, TR CU, INMETRO, CCOE, NEPSI, KOSHA, Installation in zone 2 | Turck | Quick Quote |