Frequency Transducer/Pulse Counter, 2-channel, , Input circuits monitored for wire-break and short-circuit, Parameterized via PC, Complete galvanic isolation, Removable spring type terminals, ATEX use in Zone 2, cUL, SIL 2
Quick Quote
Isolating switching amplifier, 2-channel, , 2 relay outputs (complementary contact), Switchable: 2-channel or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, ATEX, IECEx, NEPSI, cUL, cFM, INMETRO, Kosha, TIIS, TR CU EAC, DNV, GL, Installation in zone 2, SIL 2
Quick Quote
Analog Signal Isolator, 2-channel, , Intelligent actuators supplied via HART communication interface, Input circuits: 0/4…20 mA, Output circuits: 0/4…20 mA, intrinsically safe, SIL2, Removable terminal blocks, screwable, with 2 mm test box, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, UL, C, FM, US, TR CU, KOSHA, CCOE, Installation in zone 2
Quick Quote
Temperature measuring amplifier, 2-channel, , Input circuits monitored for wire-break and short-circuit, Parameterized via PC, Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, ATEX, IECEx, cFM,cUL, NEPSI, INMETRO, Kosha, TR CU EAC CMI, Installation in zone 2, SIL 2
Quick Quote
Solenoid Driver, 2-channel, , Output circuits monitored for wire-break and short-circuit, , Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX, IECEx, cUL, cFM, INMETRO, NEPSI, Kosha, TR CU EAC, TIIS, Installation in zone 2, SIL 2
Quick Quote
Coupling Relay, 1-channel, , The inputs are not polarized, Input E1 activates both outputs simultaneously, NE load connection: SIL 3 Safety Function for NE (Normally Energized) load (de-energized in safe state) is available, ND load connection: SIL 3 Safety Function for ND (Normally De-Energized) load (energized in safe state) is available, Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, ATEX use in Zone 2, SIL 3
Quick Quote
Relay coupler, 1-channel, , Output circuit: 2 relays each with 1 changeover contact, 5 A switching current at 250 VAC, Operating voltage 19…29 VDC, Removable terminal blocks, SIL3, , Galvanic isolation between input circuits and output circuits, TR CU
Quick Quote
Isolating switching amplifier, 2-channel, , 2 relay outputs (changeover), Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Common alarm output, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, TR CU, INMETRO, NEPSI, Installation in zone 2
Quick Quote
Analog signal isolator, 1-channel, , Transmission of normalized analog signals from the Ex area to the non-Ex area, Input circuit: 0/2…10 V or 0/4…20 mA, Output circuit: 0/2…10 V, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, UL, C, FM, US, TR CU, NEPSI, KOSHA, Installation in zone 2
Quick Quote
Isolating transducer, 1-channel, , Power supply of 2-wire measuring transducers with HART communication as well as connection to active 2-wire and passive 3-wire transmitters, Input circuit: 0/4…20 mA, Output circuit: 0/4…20 mA, SIL2, Removable terminal blocks, screwable, with 2 mm test box, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, UL, C, FM, US, TR CU, CCEO, Kosha, Installation in zone 2
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
IM12-FI01-2SF-2I-C0/24VDC/CC Frequency Transducer/Pulse Counter, 2-channel, , Input circuits monitored for wire-break and short-circuit, Parameterized via PC, Complete galvanic isolation, Removable spring type terminals, ATEX use in Zone 2, cUL, SIL 2 | Turck | Quick Quote | |||
IMX12-DI01-2S-2R-0/24VDC/CC Isolating switching amplifier, 2-channel, , 2 relay outputs (complementary contact), Switchable: 2-channel or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, ATEX, IECEx, NEPSI, cUL, cFM, INMETRO, Kosha, TIIS, TR CU EAC, DNV, GL, Installation in zone 2, SIL 2 | Turck | Quick Quote | |||
IM35-22EX-HI/24VDC Analog Signal Isolator, 2-channel, , Intelligent actuators supplied via HART communication interface, Input circuits: 0/4…20 mA, Output circuits: 0/4…20 mA, intrinsically safe, SIL2, Removable terminal blocks, screwable, with 2 mm test box, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, UL, C, FM, US, TR CU, KOSHA, CCOE, Installation in zone 2 | Turck | Quick Quote | |||
IMX12-TI01-2RTDR-2I-C0/24VDC Temperature measuring amplifier, 2-channel, , Input circuits monitored for wire-break and short-circuit, Parameterized via PC, Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, ATEX, IECEx, cFM,cUL, NEPSI, INMETRO, Kosha, TR CU EAC CMI, Installation in zone 2, SIL 2 | Turck | Quick Quote | |||
IMX12-DO01-2U-2U-PR/24VDC/CC Solenoid Driver, 2-channel, , Output circuits monitored for wire-break and short-circuit, , Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX, IECEx, cUL, cFM, INMETRO, NEPSI, Kosha, TR CU EAC, TIIS, Installation in zone 2, SIL 2 | Turck | Quick Quote | |||
IM12-CD01-2R-1U-0/L Coupling Relay, 1-channel, , The inputs are not polarized, Input E1 activates both outputs simultaneously, NE load connection: SIL 3 Safety Function for NE (Normally Energized) load (de-energized in safe state) is available, ND load connection: SIL 3 Safety Function for ND (Normally De-Energized) load (energized in safe state) is available, Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, ATEX use in Zone 2, SIL 3 | Turck | Quick Quote | |||
IM73-12-R/24VUC Relay coupler, 1-channel, , Output circuit: 2 relays each with 1 changeover contact, 5 A switching current at 250 VAC, Operating voltage 19…29 VDC, Removable terminal blocks, SIL3, , Galvanic isolation between input circuits and output circuits, TR CU | Turck | Quick Quote | |||
IM1-231EX-R Isolating switching amplifier, 2-channel, , 2 relay outputs (changeover), Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Common alarm output, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, TR CU, INMETRO, NEPSI, Installation in zone 2 | Turck | Quick Quote | |||
IM31-11EX-U Analog signal isolator, 1-channel, , Transmission of normalized analog signals from the Ex area to the non-Ex area, Input circuit: 0/2…10 V or 0/4…20 mA, Output circuit: 0/2…10 V, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, UL, C, FM, US, TR CU, NEPSI, KOSHA, Installation in zone 2 | Turck | Quick Quote | |||
IM33-11EX-HI/24VDC Isolating transducer, 1-channel, , Power supply of 2-wire measuring transducers with HART communication as well as connection to active 2-wire and passive 3-wire transmitters, Input circuit: 0/4…20 mA, Output circuit: 0/4…20 mA, SIL2, Removable terminal blocks, screwable, with 2 mm test box, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, UL, C, FM, US, TR CU, CCEO, Kosha, Installation in zone 2 | Turck | Quick Quote |