Temperature measuring amplifier, 1-channel, , Input circuits monitored for wire-break and short-circuit, Parameterized via PC, Complete galvanic isolation, Removable spring type terminals, ATEX, IECEx, cFM,cUL, NEPSI, INMETRO, Kosha, TR CU EAC CMI, TS, Installation in zone 2, SIL 2
Quick Quote
Isolating switching amplifier, 1-channel, , Relay output (changeover contact), NAMUR repeater, Output mode adjustable (open-circuit/closed current mode), Input circuits monitored for wire break/short circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX use in Zone 2, cUL, SIL 2
Quick Quote
Temperature measuring amplifier, 1-channel, , Connection of temperature probe Pt100, Output circuit: 0/4…20 mA or 0…10 V, Accuracy, , Complete galvanic isolation, Input reverse-polarity protected, 6.2 mm width, UL: Class1, Div2, Group A, B, C, D; GOST
Quick Quote
Isolating switching amplifier, 1-channel, , Relay output (changeover), Alarm output (changeover), Switchable: Alarm output or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, Power bridge (connector incl. in delivery), ATEX, IECEx, NEPSI, cUL, cFM, INMETRO, KOSHA, TIIS, TR CU EAC, Installation in zone 2, SIL 2
Quick Quote
Rotation direction discriminator, 1-channel, , Rotation direction discriminator, Adjustable switch-off delay, Removable terminal blocks, Complete galvanic isolation, Input reverse-polarity protected
Quick Quote
Isolating transducer, 1-channel, , Splitter function, Input circuits monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable screw terminals, ATEX, IECEx, cFM, NEPSI, INMETRO, Kosha, TR CU EAC CMI, TS, Installation in zone 2, SIL 2
Quick Quote
Analog Signal Isolator, 1-channel, , Input circuit monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable screw terminals, Connector for power bridge incl. in delivery, ATEX use in Zone 2, cUL, SIL 2
Quick Quote
Temperature measuring amplifier, 1-channel, , Input circuits monitored for wire break and short circuit, Parameterized via PC, Complete galvanic isolation, Removable screw terminals, Connector for power bridge incl. in delivery, ATEX use in Zone 2, cUL, SIL 2
Quick Quote
Isolating transducer, 1-channel, , Input circuits monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable screw terminals, ATEX, IECEx, cFM, NEPSI, INMETRO, Kosha, TR CU EAC CMI, TS, Installation in zone 2, SIL 2
Quick Quote
Isolating switching amplifier, 2-channel, , 2 transistor outputs (≤ 10kHz), Switchable: 2-channel or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX, IECEx, NEPSI, cUL, cFM, INMETRO, Kosha, TIIS, TR CU EAC, DNV, GL, Installation in zone 2, SIL 2
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
IMX12-TI02-1TCURTDR-1I1R-C0/24VDC/CC Temperature measuring amplifier, 1-channel, , Input circuits monitored for wire-break and short-circuit, Parameterized via PC, Complete galvanic isolation, Removable spring type terminals, ATEX, IECEx, cFM,cUL, NEPSI, INMETRO, Kosha, TR CU EAC CMI, TS, Installation in zone 2, SIL 2 | Turck | Quick Quote | |||
IM12-DI03-1S-1NAM1R-PR/24VDC/CC Isolating switching amplifier, 1-channel, , Relay output (changeover contact), NAMUR repeater, Output mode adjustable (open-circuit/closed current mode), Input circuits monitored for wire break/short circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX use in Zone 2, cUL, SIL 2 | Turck | Quick Quote | |||
IMS-TI-PT100/24V Temperature measuring amplifier, 1-channel, , Connection of temperature probe Pt100, Output circuit: 0/4…20 mA or 0…10 V, Accuracy, , Complete galvanic isolation, Input reverse-polarity protected, 6.2 mm width, UL: Class1, Div2, Group A, B, C, D; GOST | Turck | Quick Quote | |||
IMX12-DI03-1S-2R-SPR/24VDC Isolating switching amplifier, 1-channel, , Relay output (changeover), Alarm output (changeover), Switchable: Alarm output or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, Power bridge (connector incl. in delivery), ATEX, IECEx, NEPSI, cUL, cFM, INMETRO, KOSHA, TIIS, TR CU EAC, Installation in zone 2, SIL 2 | Turck | Quick Quote | |||
MS23-R Rotation direction discriminator, 1-channel, , Rotation direction discriminator, Adjustable switch-off delay, Removable terminal blocks, Complete galvanic isolation, Input reverse-polarity protected | Turck | Quick Quote | |||
IMX12-AI01-1I-2IU-H0/24VDC Isolating transducer, 1-channel, , Splitter function, Input circuits monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable screw terminals, ATEX, IECEx, cFM, NEPSI, INMETRO, Kosha, TR CU EAC CMI, TS, Installation in zone 2, SIL 2 | Turck | Quick Quote | |||
IM12-AO01-1I-1I-HPR/24VDC Analog Signal Isolator, 1-channel, , Input circuit monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable screw terminals, Connector for power bridge incl. in delivery, ATEX use in Zone 2, cUL, SIL 2 | Turck | Quick Quote | |||
IM12-TI02-1TCURTDR-1I1R-CPR/24VDC Temperature measuring amplifier, 1-channel, , Input circuits monitored for wire break and short circuit, Parameterized via PC, Complete galvanic isolation, Removable screw terminals, Connector for power bridge incl. in delivery, ATEX use in Zone 2, cUL, SIL 2 | Turck | Quick Quote | |||
IMX12-AI01-1I-1IU-H0/24VDC Isolating transducer, 1-channel, , Input circuits monitored for wire break and short circuit, Complete galvanic isolation, HART transparent, Removable screw terminals, ATEX, IECEx, cFM, NEPSI, INMETRO, Kosha, TR CU EAC CMI, TS, Installation in zone 2, SIL 2 | Turck | Quick Quote | |||
IMX12-DI01-2S-2T-PR/24VDC/CC Isolating switching amplifier, 2-channel, , 2 transistor outputs (≤ 10kHz), Switchable: 2-channel or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX, IECEx, NEPSI, cUL, cFM, INMETRO, Kosha, TIIS, TR CU EAC, DNV, GL, Installation in zone 2, SIL 2 | Turck | Quick Quote |