PULS ML100.109 is a power supply unit (PSU) / converter designed for AC/DC applications with DIN rail mounting. It operates within an ambient air temperature range of -10 to +70°C and features a conformal coating design for enhanced durability. This unit provides a rated current of 4.2A at 24Vdc and utilizes spring-clamp connections for secure attachment. It supports a wide range of supply voltages from 85Vac-132Vac / 184Vac-264Vac (auto select) for AC and 213Vdc-348Vdc for DC, accommodating various network configurations including single-phase (1AC) or DC. The ML100.109 measures 73mm in width, 75mm in height, and 103mm in depth, housed in a PC / ABS blend for robustness. It delivers a rated power of 100W with an adjustable output voltage range of 24Vdc-28Vdc. Protection is provided by an NTC (input inrush current limiter), ensuring stability. The unit boasts an efficiency of 0.9 at 230Vac input, with a maximum inrush current consumption of 22A at 120Vac input and 37A peak at 230Vac input. Power dissipation is calculated at 11.4 W, and the ripple is maintained at 50mVpp across a frequency range of 20Hz to 20MHz at 50Ω.
Quick Quote
PULS QT20.361 is a power supply unit designed for DIN rail mounting, featuring AC/DC conversion with a 50% power reserve. It operates within an ambient air temperature range of -25 to +70°C and offers a design that includes a DC-OK relay contact output. The unit provides a rated current of 13.3A at 36Vdc and 11.4A at 42Vdc, with a power derating from 12W at +60°C to +70°C. Connection is facilitated through spring-clamp connections. It supports a wide supply voltage range of 323Vac to 576Vac across various nominal voltages (380Vac to 525Vac) at 47-63Hz, with a 3-phase input. The QT20.361, part of the Q-series, measures 65mm in width, 124mm in height, and 127mm in depth, housed in aluminium. It is designed for a 3-phase network, with a rated power of 480W at 36Vdc and 42Vdc, and can momentarily support up to 720W for 4 seconds. The output voltage is adjustable between 36Vdc and 42Vdc, with protection functions including output overvoltage protection and active input inrush current limiting. It allows for series or parallel operation for increased output power and is resistant to back-feeding loads up to 48V. The unit boasts an efficiency of up to 0.948, with a peak current consumption of 10A at inrush. It features a start-up delay of 290-350ms, a rise time of 30-40ms depending on load capacitance, and a hold time of 22ms. Power dissipation is 27.4W at full output load with a 3x480Vac input and 26.3W with a 3x400Vac input. Its electrical durability ranges from 48,000 to 250,000 hours, depending on operating conditions, with a ripple of 100mVpp and an output stage capacitance of 500µF.
Quick Quote
PULS PIM60.125 is a power supply unit that functions as an AC/DC PSU/converter with DIN rail mounting. It operates within an ambient air temperature range of -10 to +60°C with linear derating up to +70°C. This unit features a NEC Class 2 DC-OK relay contact output and provides a rated current of 2.5A at 24Vdc within -10 to +60°C and 1.9A at 24Vdc at +70°C. It offers push-in spring connections for ease of installation. The supply voltage (AC) ranges from 90Vac to 264Vac across various nominal voltages and frequencies, with specific input overvoltage and shutdown voltage parameters. The PIM-series unit measures W36mm x H90mm x D91mm, has an IP20 degree of protection, and is housed in a polycarbonate (PC) material. Designed for single-phase (1AC) networks, it has a net width of 36 mm and delivers a rated power of 60W at -10 to +60°C, which derates linearly to 45.6W at +70°C. The output voltage (DC) is adjustable between 24Vdc and 28Vdc, with specific protection functions against overvoltage and overload/short-circuit conditions. It does not support series or parallel operation and is resistant to back-feeding loads. The efficiency rates are 0.918 and 0.907 for 230Vac and 120Vac inputs, respectively. Current consumption varies with input voltage, and the unit exhibits specific start-up delay, rise time, and hold time characteristics. Power dissipation/losses are detailed for different input conditions, and the electrical durability is specified across various operational conditions. The ripple is noted at 100mVpp, and the output stage capacitance is 900 µF.
Quick Quote
PULS PISA11.203206 is a protection unit designed as a 4-channel protection module with 1 input and 4 outputs, suitable for DIN rail mounting. It operates within an ambient air temperature range of -25 to +70°C and adheres to NEC Class 2 design specifications. The rated current for the device is 4A, distributed as 1A across each of the four outputs, and it features screw-clamp connections for secure installation. This part falls under the PISA11-series and has dimensions of W45mm x H75mm x D91mm. It requires a supply voltage of 18Vdc to 30Vdc, with 24Vdc as the typical value and 21.4Vdc as the necessary input voltage to activate the outputs. The output voltage is adjustable between 24Vdc and 28Vdc. Protection functions include short-circuit protection with a 110ms shutdown time and current limitation with a 9A to 12.7A adjustable threshold. Power dissipation at full output load with a 24V input is 1W, and the processing time for output turn-on delay is 270ms. The voltage drop across the device is 41mV / 0.041 V. Electrical durability is rated at 243,000 hours at 40°C with 4x0.5A output and 686,000 hours at 25°C with 4x0.5A output.
Quick Quote
Banner Engineering PISA11.404 is a fiber optic sensor designed for in-line sensing with a through-beam system or opposed mode pair of individual fibers. It operates effectively at an ambient air temperature up to +70°C. This sensor is part of the Plastic fiber series and features a cylindrical (threaded) probe tip with a diameter of 0.25mm for the fiber core. The sensing end is made of stainless steel, while the fiber itself is plastic, and the fiber sheath is constructed from polyethylene (PE). The total length of the sensor is 6ft / 2m, accommodating various installation requirements.
Quick Quote
PULS QT20.241-C1 is a power supply unit designed for DIN rail mounting, featuring AC/DC conversion with a 50% power reserve. It operates within an ambient air temperature range of -25 to +70°C and is equipped with a conformal coating for enhanced durability in harsh environments. The unit provides a rated current of 20A at 24Vdc and 17.5A at 28Vdc, with a power derating from 12W at +60°C to +70°C. Connection is facilitated through spring-clamp connections. It supports a wide range supply voltage of 323Vac to 576Vac for 3-phase input, including a broad spectrum of nominal voltages from 380Vac to 525Vac at 47-63Hz. The QT20.241-C1, part of the Q-series, measures 65mm in width, 124mm in height, and 127mm in depth, housed in an aluminium casing. It is designed for a 3-phase network, offering a rated power of 480W and a short-term power of 720W for up to 4 seconds. The output voltage is adjustable between 24Vdc and 28Vdc, with comprehensive protection functions against overvoltage, overload, and short-circuit conditions. Efficiency rates are high at 0.948 and 0.95 for 3x480Vac and 3x400Vac inputs, respectively. The unit exhibits a start-up delay of 290-350ms and a hold time of 22ms, with power dissipation losses calculated at 26.4W for 3x480Vac input and 25.3W for 3x400Vac input under full load. Electrical durability is rated at up to 345000 hours at 25°C with a 10A output and 3AC 400Vac input. The output stage capacitance is 950µF, and the ripple is maintained at 100mVpp across a 20Hz to 20MHz range.
Quick Quote
PULS QT40.242 is a power supply unit designed for AC/DC conversion with a 50% power reserve. It supports DIN rail mounting and operates within an ambient air temperature range of -25 to +70°C. This unit features an extended lifetime and includes a DC-OK relay contact output. It provides a rated current of 40A at 24Vdc and 34.3A at 28Vdc, with a derating to 24W between +60°C and +70°C. The QT40.242 utilizes screw-clamp connections and accepts a wide range supply voltage of 323Vac-576Vac across various nominal voltages (380Vac / 400Vac / 415Vac / 440Vac / 480Vac / 500Vac / 525Vac; 47-63Hz) with a 3-phase input. It belongs to the Q-series and is housed in an aluminium casing with dimensions of W110mm x H124mm x D127mm. Designed for a 3-phase network, it has a net width of 110 mm and offers a rated power of 960W (up to 1440W short-term for 4s). The output voltage is adjustable between 24Vdc and 28Vdc. Protection features include output overvoltage protection and active input inrush current limiter, with overload and short-circuit current protection supporting both series and parallel operation. The unit is resistant to back-feeding loads up to 35V. It achieves an efficiency of 0.952 to 0.953 depending on the input voltage, with a peak current consumption of 6A max. inrush. The start-up delay ranges from 500-600s, with a rise time of 35-40ms and a hold time of 25ms. Power dissipation/losses are 47.3W to 48.4W, depending on the input voltage. Electrical durability varies with conditions, reaching up to 475,000 hours at 25°C and 20A output with a 3AC 400Vac input. Ripple is maintained at 100mVpp, and the output stage capacitance is 10200 µF.
Quick Quote
PULS UB10.242 is an Uninterruptible Power Supply (UPS) control module from the UB-series, featuring an external battery with temperature control and a 50% power reserve. It includes a green status LED for visual indication of operational states such as Ready, Buffering, Inhibit, and Replace Battery. The device is housed in an aluminium casing and utilizes spring-clamp connections for secure and efficient connectivity. With dimensions of W49mm x H124mm x D117mm, it supports a supply voltage range of 22.5Vdc to 30Vdc (24Vdc nominal) and offers a rated current of 10A at 22.5Vdc and 15A in buffer mode for less than 5 seconds at full output voltage. The UB10.242 is designed for DIN rail mounting and can operate in ambient air temperatures ranging from -25 to +50°C. It consumes 2A at a 24Vdc input and up to 2.7A max., with an efficiency of 0.978 at 24Vdc input. The rated power is 360W at 24Vdc and 240W/360W in buffer mode, with power dissipation/losses of 2.9W at 0A output current and 5.5W at 10A output current. The ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. Its electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output. The device ensures protection against output overvoltage (32Vdc typical, 35Vdc max.) and overload/short-circuit conditions, with a minimum short-circuit current of 17.9A (max. 21A) at load impedance. It is not designed for parallel use to increase output power but supports 1+1 redundancy for enhanced system reliability.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
ML100.109 PULS ML100.109 is a power supply unit (PSU) / converter designed for AC/DC applications with DIN rail mounting. It operates within an ambient air temperature range of -10 to +70°C and features a conformal coating design for enhanced durability. This unit provides a rated current of 4.2A at 24Vdc and utilizes spring-clamp connections for secure attachment. It supports a wide range of supply voltages from 85Vac-132Vac / 184Vac-264Vac (auto select) for AC and 213Vdc-348Vdc for DC, accommodating various network configurations including single-phase (1AC) or DC. The ML100.109 measures 73mm in width, 75mm in height, and 103mm in depth, housed in a PC / ABS blend for robustness. It delivers a rated power of 100W with an adjustable output voltage range of 24Vdc-28Vdc. Protection is provided by an NTC (input inrush current limiter), ensuring stability. The unit boasts an efficiency of 0.9 at 230Vac input, with a maximum inrush current consumption of 22A at 120Vac input and 37A peak at 230Vac input. Power dissipation is calculated at 11.4 W, and the ripple is maintained at 50mVpp across a frequency range of 20Hz to 20MHz at 50Ω. | Puls | Quick Quote | |||
QT20.361 PULS QT20.361 is a power supply unit designed for DIN rail mounting, featuring AC/DC conversion with a 50% power reserve. It operates within an ambient air temperature range of -25 to +70°C and offers a design that includes a DC-OK relay contact output. The unit provides a rated current of 13.3A at 36Vdc and 11.4A at 42Vdc, with a power derating from 12W at +60°C to +70°C. Connection is facilitated through spring-clamp connections. It supports a wide supply voltage range of 323Vac to 576Vac across various nominal voltages (380Vac to 525Vac) at 47-63Hz, with a 3-phase input. The QT20.361, part of the Q-series, measures 65mm in width, 124mm in height, and 127mm in depth, housed in aluminium. It is designed for a 3-phase network, with a rated power of 480W at 36Vdc and 42Vdc, and can momentarily support up to 720W for 4 seconds. The output voltage is adjustable between 36Vdc and 42Vdc, with protection functions including output overvoltage protection and active input inrush current limiting. It allows for series or parallel operation for increased output power and is resistant to back-feeding loads up to 48V. The unit boasts an efficiency of up to 0.948, with a peak current consumption of 10A at inrush. It features a start-up delay of 290-350ms, a rise time of 30-40ms depending on load capacitance, and a hold time of 22ms. Power dissipation is 27.4W at full output load with a 3x480Vac input and 26.3W with a 3x400Vac input. Its electrical durability ranges from 48,000 to 250,000 hours, depending on operating conditions, with a ripple of 100mVpp and an output stage capacitance of 500µF. | Puls | Quick Quote | |||
PIM60.125 PULS PIM60.125 is a power supply unit that functions as an AC/DC PSU/converter with DIN rail mounting. It operates within an ambient air temperature range of -10 to +60°C with linear derating up to +70°C. This unit features a NEC Class 2 DC-OK relay contact output and provides a rated current of 2.5A at 24Vdc within -10 to +60°C and 1.9A at 24Vdc at +70°C. It offers push-in spring connections for ease of installation. The supply voltage (AC) ranges from 90Vac to 264Vac across various nominal voltages and frequencies, with specific input overvoltage and shutdown voltage parameters. The PIM-series unit measures W36mm x H90mm x D91mm, has an IP20 degree of protection, and is housed in a polycarbonate (PC) material. Designed for single-phase (1AC) networks, it has a net width of 36 mm and delivers a rated power of 60W at -10 to +60°C, which derates linearly to 45.6W at +70°C. The output voltage (DC) is adjustable between 24Vdc and 28Vdc, with specific protection functions against overvoltage and overload/short-circuit conditions. It does not support series or parallel operation and is resistant to back-feeding loads. The efficiency rates are 0.918 and 0.907 for 230Vac and 120Vac inputs, respectively. Current consumption varies with input voltage, and the unit exhibits specific start-up delay, rise time, and hold time characteristics. Power dissipation/losses are detailed for different input conditions, and the electrical durability is specified across various operational conditions. The ripple is noted at 100mVpp, and the output stage capacitance is 900 µF. | Puls | Quick Quote | |||
PISA11.203206 PULS PISA11.203206 is a protection unit designed as a 4-channel protection module with 1 input and 4 outputs, suitable for DIN rail mounting. It operates within an ambient air temperature range of -25 to +70°C and adheres to NEC Class 2 design specifications. The rated current for the device is 4A, distributed as 1A across each of the four outputs, and it features screw-clamp connections for secure installation. This part falls under the PISA11-series and has dimensions of W45mm x H75mm x D91mm. It requires a supply voltage of 18Vdc to 30Vdc, with 24Vdc as the typical value and 21.4Vdc as the necessary input voltage to activate the outputs. The output voltage is adjustable between 24Vdc and 28Vdc. Protection functions include short-circuit protection with a 110ms shutdown time and current limitation with a 9A to 12.7A adjustable threshold. Power dissipation at full output load with a 24V input is 1W, and the processing time for output turn-on delay is 270ms. The voltage drop across the device is 41mV / 0.041 V. Electrical durability is rated at 243,000 hours at 40°C with 4x0.5A output and 686,000 hours at 25°C with 4x0.5A output. | Puls | Quick Quote | |||
PISA11.404 Banner Engineering PISA11.404 is a fiber optic sensor designed for in-line sensing with a through-beam system or opposed mode pair of individual fibers. It operates effectively at an ambient air temperature up to +70°C. This sensor is part of the Plastic fiber series and features a cylindrical (threaded) probe tip with a diameter of 0.25mm for the fiber core. The sensing end is made of stainless steel, while the fiber itself is plastic, and the fiber sheath is constructed from polyethylene (PE). The total length of the sensor is 6ft / 2m, accommodating various installation requirements. | Puls | Quick Quote | |||
QS10.121-A1 Power Supply, 180W, 100-240VAC 1PH, 12-15VDC, 15-12A with ATEX Approval | Puls | Quick Quote | |||
QS10.481-A1 Power Supply, 240W, 100-240VAC 1PH, 48-56VDC, 5-4.3A with ATEX Approval | Puls | Quick Quote | |||
QT20.241-C1 PULS QT20.241-C1 is a power supply unit designed for DIN rail mounting, featuring AC/DC conversion with a 50% power reserve. It operates within an ambient air temperature range of -25 to +70°C and is equipped with a conformal coating for enhanced durability in harsh environments. The unit provides a rated current of 20A at 24Vdc and 17.5A at 28Vdc, with a power derating from 12W at +60°C to +70°C. Connection is facilitated through spring-clamp connections. It supports a wide range supply voltage of 323Vac to 576Vac for 3-phase input, including a broad spectrum of nominal voltages from 380Vac to 525Vac at 47-63Hz. The QT20.241-C1, part of the Q-series, measures 65mm in width, 124mm in height, and 127mm in depth, housed in an aluminium casing. It is designed for a 3-phase network, offering a rated power of 480W and a short-term power of 720W for up to 4 seconds. The output voltage is adjustable between 24Vdc and 28Vdc, with comprehensive protection functions against overvoltage, overload, and short-circuit conditions. Efficiency rates are high at 0.948 and 0.95 for 3x480Vac and 3x400Vac inputs, respectively. The unit exhibits a start-up delay of 290-350ms and a hold time of 22ms, with power dissipation losses calculated at 26.4W for 3x480Vac input and 25.3W for 3x400Vac input under full load. Electrical durability is rated at up to 345000 hours at 25°C with a 10A output and 3AC 400Vac input. The output stage capacitance is 950µF, and the ripple is maintained at 100mVpp across a 20Hz to 20MHz range. | Puls | Quick Quote | |||
QT40.242 PULS QT40.242 is a power supply unit designed for AC/DC conversion with a 50% power reserve. It supports DIN rail mounting and operates within an ambient air temperature range of -25 to +70°C. This unit features an extended lifetime and includes a DC-OK relay contact output. It provides a rated current of 40A at 24Vdc and 34.3A at 28Vdc, with a derating to 24W between +60°C and +70°C. The QT40.242 utilizes screw-clamp connections and accepts a wide range supply voltage of 323Vac-576Vac across various nominal voltages (380Vac / 400Vac / 415Vac / 440Vac / 480Vac / 500Vac / 525Vac; 47-63Hz) with a 3-phase input. It belongs to the Q-series and is housed in an aluminium casing with dimensions of W110mm x H124mm x D127mm. Designed for a 3-phase network, it has a net width of 110 mm and offers a rated power of 960W (up to 1440W short-term for 4s). The output voltage is adjustable between 24Vdc and 28Vdc. Protection features include output overvoltage protection and active input inrush current limiter, with overload and short-circuit current protection supporting both series and parallel operation. The unit is resistant to back-feeding loads up to 35V. It achieves an efficiency of 0.952 to 0.953 depending on the input voltage, with a peak current consumption of 6A max. inrush. The start-up delay ranges from 500-600s, with a rise time of 35-40ms and a hold time of 25ms. Power dissipation/losses are 47.3W to 48.4W, depending on the input voltage. Electrical durability varies with conditions, reaching up to 475,000 hours at 25°C and 20A output with a 3AC 400Vac input. Ripple is maintained at 100mVpp, and the output stage capacitance is 10200 µF. | Puls | Quick Quote | |||
UB10.242 PULS UB10.242 is an Uninterruptible Power Supply (UPS) control module from the UB-series, featuring an external battery with temperature control and a 50% power reserve. It includes a green status LED for visual indication of operational states such as Ready, Buffering, Inhibit, and Replace Battery. The device is housed in an aluminium casing and utilizes spring-clamp connections for secure and efficient connectivity. With dimensions of W49mm x H124mm x D117mm, it supports a supply voltage range of 22.5Vdc to 30Vdc (24Vdc nominal) and offers a rated current of 10A at 22.5Vdc and 15A in buffer mode for less than 5 seconds at full output voltage. The UB10.242 is designed for DIN rail mounting and can operate in ambient air temperatures ranging from -25 to +50°C. It consumes 2A at a 24Vdc input and up to 2.7A max., with an efficiency of 0.978 at 24Vdc input. The rated power is 360W at 24Vdc and 240W/360W in buffer mode, with power dissipation/losses of 2.9W at 0A output current and 5.5W at 10A output current. The ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. Its electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output. The device ensures protection against output overvoltage (32Vdc typical, 35Vdc max.) and overload/short-circuit conditions, with a minimum short-circuit current of 17.9A (max. 21A) at load impedance. It is not designed for parallel use to increase output power but supports 1+1 redundancy for enhanced system reliability. | Puls | Quick Quote |