XCSLF3535333 Telemecanique Sensors Safety Switches

Telemecanique Sensors XCSLF3535333 Telemecanique XCSLF3535333 is a safety lock designed for door, cover, and hood safety guard interlock applications, featuring a limit switch that locks on de-energization and unlocks on energization with a break before make/slow break function. It has a rated impulse voltage (Uimp) of 4 kV and is constructed from Zamak for both the head and body. This part offers three 1/2" NPT cable entries for connections and is rated with an IP67 degree of protection, ensuring durability against dust and water ingress. It is capable of 1,000,000 mechanical operations at no load and has a 3 Pole configuration. The control voltage for AC is set at 110/120 Vac, with two Normally Open (NO) auxiliary contacts and one Normally Closed (NC) auxiliary contact. The rated insulation voltage (Ui) stands at 250 V for UL and 300 V, complemented by an orange LED for guard opening and a green LED for guard locking visual indicators. The control circuit rated current is 0.75 A for 240Vac (AC-15) and 100mA / 0.1 A for 250Vdc (DC-13), with similar ratings for other specified conditions. It operates within a temperature range of -25 °C to 70 °C and offers electrical durability of 1,000,000 operations with load. The latching type is a solenoid locking mechanism featuring 1NC+2NO break before make contact.
Telemecanique Sensors

Part#:XCSLF3535333

Manufacturer:Telemecanique Sensors

Product Lifecycle:Active

Get a quick Quote!

Telemecanique XCSLF3535333 is a safety lock designed for door, cover, and hood safety guard interlock applications, featuring a limit switch that locks on de-energization and unlocks on energization with a break before make/slow break function. It has a rated impulse voltage (Uimp) of 4 kV and is constructed from Zamak for both the head and body. This part offers three 1/2" NPT cable entries for connections and is rated with an IP67 degree of protection, ensuring durability against dust and water ingress. It is capable of 1,000,000 mechanical operations at no load and has a 3 Pole configuration. The control voltage for AC is set at 110/120 Vac, with two Normally Open (NO) auxiliary contacts and one Normally Closed (NC) auxiliary contact. The rated insulation voltage (Ui) stands at 250 V for UL and 300 V, complemented by an orange LED for guard opening and a green LED for guard locking visual indicators. The control circuit rated current is 0.75 A for 240Vac (AC-15) and 100mA / 0.1 A for 250Vdc (DC-13), with similar ratings for other specified conditions. It operates within a temperature range of -25 °C to 70 °C and offers electrical durability of 1,000,000 operations with load. The latching type is a solenoid locking mechanism featuring 1NC+2NO break before make contact.

About the manufacturer: Telemecanique Sensors is one of the manufacturers that offers Safety Switches that you can order at Powermatic Associates site. For more than forty years, Telemecanique Sensors, formerly Hyde Park, has been refining ultrasonic technology and has become a leading global provider in this industry. Through the use of advanced ultrasonic technology, Telemecanique designs and manufactures reliable noncontact sensors.

Check out the XCSLF3535333 Telemecanique Sensors price in the box on the right side or send a quick quote.

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


XCSLF3535333 Description

Telemecanique XCSLF3535333 is a safety lock designed for door, cover, and hood safety guard interlock applications, featuring a limit switch that locks on de-energization and unlocks on energization with a break before make/slow break function. It has a rated impulse voltage (Uimp) of 4 kV and is constructed from Zamak for both the head and body. This part offers three 1/2" NPT cable entries for connections and is rated with an IP67 degree of protection, ensuring durability against dust and water ingress. It is capable of 1,000,000 mechanical operations at no load and has a 3 Pole configuration. The control voltage for AC is set at 110/120 Vac, with two Normally Open (NO) auxiliary contacts and one Normally Closed (NC) auxiliary contact. The rated insulation voltage (Ui) stands at 250 V for UL and 300 V, complemented by an orange LED for guard opening and a green LED for guard locking visual indicators. The control circuit rated current is 0.75 A for 240Vac (AC-15) and 100mA / 0.1 A for 250Vdc (DC-13), with similar ratings for other specified conditions. It operates within a temperature range of -25 °C to 70 °C and offers electrical durability of 1,000,000 operations with load. The latching type is a solenoid locking mechanism featuring 1NC+2NO break before make contact.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts

UBC10.241

UBC10.241

PULS UBC10.241 is an Uninterruptible Power Supply (UPS) control module within the U-series, featuring a built-in battery with a 50% power reserve and a green status LED. This module is housed in aluminium and utilizes spring-clamp connections for installation. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can reach up to 15A in buffer mode for less than 5 seconds at full output voltage. It supports DIN rail mounting and can operate in ambient air temperatures ranging from 0 to +40°C. The current consumption is 1.1A at a 24Vdc input, and it is designed for DC networks. Visual position indicators include Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. It is advised not to use the DC-UPS in parallel to increase output power, but paralleling two units for 1+1 redundancy is possible for higher system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. The efficiency is rated at 0.978 with a 24Vdc input, and the rated power is 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W with a 24Vdc input at 0A output current and 5.5W at 10A output current. Ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. The electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output.

Puls

1