Schneider Electric LC1F780F7 Schneider Electric LC1F780F7 is a high-power magnetic contactor within the F sub-range, designed for surface mounting. It features a 3-pole (3P; 3NO) configuration and supports ring-lugs/bar connections. The contactor is rated for currents up to 1600A in AC-1 applications and 780A in 440Vac AC-3 scenarios. The control voltage (AC) specifications are 94-121Vac (110Vac nominal; 40-400Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 1000 V. It has no Normally Open (NO) or Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 8 kV. Its rated active power ranges from 220kW at 220-230Vac in AC-3 applications up to 475kW at 660-690Vac in AC-3 applications, with additional ratings for various voltages in between. The mechanical durability of the LC1F780F7, at no load, is rated for 5,000,000 operations, and the rated voltage (AC) phase-to-phase is 1000 V.
Schneider Electric

Part#:LC1F780F7

Manufacturer:Schneider Electric

Product Lifecycle:Active

Get a quick Quote!

Schneider Electric LC1F780F7 is a high-power magnetic contactor within the F sub-range, designed for surface mounting. It features a 3-pole (3P; 3NO) configuration and supports ring-lugs/bar connections. The contactor is rated for currents up to 1600A in AC-1 applications and 780A in 440Vac AC-3 scenarios. The control voltage (AC) specifications are 94-121Vac (110Vac nominal; 40-400Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 1000 V. It has no Normally Open (NO) or Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 8 kV. Its rated active power ranges from 220kW at 220-230Vac in AC-3 applications up to 475kW at 660-690Vac in AC-3 applications, with additional ratings for various voltages in between. The mechanical durability of the LC1F780F7, at no load, is rated for 5,000,000 operations, and the rated voltage (AC) phase-to-phase is 1000 V.

About the manufacturer: Schneider Electric is one of the manufacturers that offers Electronic Components that you can order at Powermatic Associates site. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.

Check out the LC1F780F7 Schneider Electric price in the box on the right side or send a quick quote.

Product Details

  • Product Certifications
    UL RINA ABS CB RMRoS CSA LROS (Lloyds register of shipping) DNV BV UKCA
  • Motor Power Kw
    450 kW 1000 V AC 50/60 Hz AC-3) 400 kW 380...400 V AC 50/60 Hz AC-3) 425 kW 415 V AC 50/60 Hz AC-3) 425 kW 440 V AC 50/60 Hz AC-3) 450 kW 500 V AC 50/60 Hz AC-3) 475 kW 660...690 V AC 50/60 Hz AC-3) 220 kW 220...230 V AC 50/6
  • [Icw] Rated Short-Time Withstand Current
    3000 A 104 °F (40 °C) - 3 min 6250 A 104 °F (40 °C) - 10 s 5600 A 104 °F (40 °C) - 30 s 4600 A 104 °F (40 °C) - 1 min 2200 A 104 °F (40 °C) - 10 min
  • Standards
    EN 60947-1 JIS C8201-4-1 IEC 60947-4-1 IEC 60947-1 EN 60947-4-1
  • Motor Power Range
    250…500 kW 380…440 V 3 phase 110…220 kW 200…240 V 3 phase 250…500 kW 480…500 V 3 phase
  • Connections - Terminals
    Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)fl
  • Utilisation Category
    AC-4 AC-1 AC-3
  • Operating Time
    40...80 ms closing 130...230 ms opening
  • [Ui] Rated Insulation Voltage
    1000 V IEC 60947-4-1 1500 V VDE 0110 group C
  • Power Dissipation Per Pole
    250 W AC-1 60 W AC-3
  • Contactor Coil Voltage
    110 V AC standard 120 V AC standard
  • Tightening Torque
    Control circuit 10.62 lbf.in (1.2 N.m) Power circuit 513.34 lbf.in (58 N.m)
  • [Ue] Rated Operational Voltage
    <= 1000 V AC 50/60 Hz <= 460 V DC
  • [Ie] Rated Operational Current
    1600 A 104 °F (40 °C)) <= 440 V AC AC-1 780 A 131 °F (55 °C)) <= 440 V AC AC-3
  • Associated Fuse Rating
    1600 A gG <= 440 V 800 A aM <= 440 V
  • Contactor Application
    Resistive load Motor control
  • Control Circuit Voltage Limits
    Operational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C)) Drop-out 0.2...0.4 Uc 40...400 Hz 131 °F (55 °C))
  • Mechanical Durability
    5 Mcycles
  • Hold-In Power Consumption In VA
    50 VA 40...400 Hz 0.9 68 °F (20 °C))
  • Motor Starter Type
    Direct on-line contactor
  • Compatibility Code
    LC1F
  • Maximum Operating Rate
    600 cyc/h 55 °C
  • Heat Dissipation
    44 W
  • Inrush Power In VA
    2100 VA 40...400 Hz 0.9 68 °F (20 °C))
  • Mounting Support
    Plate
  • Rated Breaking Capacity
    6240 A IEC 60947-4-1
  • Overvoltage Category
    III
  • Average Impedance
    0.1 mOhm - Ith 1600 A 50 Hz
  • [Uimp] Rated Impulse Withstand Voltage
    8 kV
  • [Ith] Conventional Free Air Thermal Current
    1600 A 104 °F (40 °C)
  • [Uc] Control Circuit Voltage
    110 V AC 40...400 Hz
  • Power Pole Contact Composition
    3 NO
  • Poles Description
    3P
  • Device Short Name
    LC1F
  • Product Name
    TeSys F
  • Product Or Component Type
    Contactor
  • Range
    TeSys

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.



Manufacturer warranty

$7,788.00

Request a quote, and we will send availability within minutes.

Select Qty:

$7,788.00

$7,788.00 each

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Relevant products

What can I help you find today?

Recommended parts

UBC10.241

UBC10.241

PULS UBC10.241 is an Uninterruptible Power Supply (UPS) control module within the U-series, featuring a built-in battery with a 50% power reserve and a green status LED. This module is housed in aluminium and utilizes spring-clamp connections for installation. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can reach up to 15A in buffer mode for less than 5 seconds at full output voltage. It supports DIN rail mounting and can operate in ambient air temperatures ranging from 0 to +40°C. The current consumption is 1.1A at a 24Vdc input, and it is designed for DC networks. Visual position indicators include Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. It is advised not to use the DC-UPS in parallel to increase output power, but paralleling two units for 1+1 redundancy is possible for higher system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. The efficiency is rated at 0.978 with a 24Vdc input, and the rated power is 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W with a 24Vdc input at 0A output current and 5.5W at 10A output current. Ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. The electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output.

Puls