Square D by Schneider Electric BDL26030LV is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BDL sub-range, featuring a PowerPact B-Frame 100 TMD 2P 30A 600Y/347Vac with a 14kA rating and Everlink (Creep compensating) lugs on both line and load sides, plus a Control Wire terminal (CWT) on the load side only. It has a rated impulse voltage (Uimp) of 8 kV and offers an IP40 degree of protection. The rated current is 30A, with a rated voltage (AC) of 600Vac 600Y/347Vac. This MCCB has a mechanical durability of 20,000 operations at no load and can be mounted either on a DIN rail or as an individual unit on a plate. It features 2 poles (2P), with dimensions of 137 mm in height, 80 mm in depth, and 54 mm in width. The utilisation category is A, and it includes over-current protection fixed at 30A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 525 V. Protection functions include thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 30 AT. Its electrical durability with load is rated for 10,000 operations at 440Vac; In. The frame current rating is 100 AF, and it operates via a toggle (manual) mode. The short circuit breaking rating varies by voltage, with 25kA at 240Vac, 18kA at 480Vac and 480Y/277Vac, and 14kA at 600Y/347Vac under UL489 standards. The trip unit type is thermal-magnetic (fixed) without a display.

About the manufacturer: Schneider Electric is one of the manufacturers that offers Molded Case Circuit Breakers (MCCB) that you can order at Powermatic Associates site. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.

Check out the BDL26030LV Schneider Electric price in the box on the right side or send a quick quote.

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


BDL26030LV Description

Square D by Schneider Electric BDL26030LV is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BDL sub-range, featuring a PowerPact B-Frame 100 TMD 2P 30A 600Y/347Vac with a 14kA rating and Everlink (Creep compensating) lugs on both line and load sides, plus a Control Wire terminal (CWT) on the load side only. It has a rated impulse voltage (Uimp) of 8 kV and offers an IP40 degree of protection. The rated current is 30A, with a rated voltage (AC) of 600Vac 600Y/347Vac. This MCCB has a mechanical durability of 20,000 operations at no load and can be mounted either on a DIN rail or as an individual unit on a plate. It features 2 poles (2P), with dimensions of 137 mm in height, 80 mm in depth, and 54 mm in width. The utilisation category is A, and it includes over-current protection fixed at 30A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 525 V. Protection functions include thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 30 AT. Its electrical durability with load is rated for 10,000 operations at 440Vac; In. The frame current rating is 100 AF, and it operates via a toggle (manual) mode. The short circuit breaking rating varies by voltage, with 25kA at 240Vac, 18kA at 480Vac and 480Y/277Vac, and 14kA at 600Y/347Vac under UL489 standards. The trip unit type is thermal-magnetic (fixed) without a display.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts

UBC10.241 on Powermatic Associates

UBC10.241

PULS UBC10.241 is an Uninterruptible Power Supply (UPS) control module within the U-series, featuring a built-in battery with a 50% power reserve and a green status LED. This module is housed in aluminium and utilizes spring-clamp connections for installation. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can reach up to 15A in buffer mode for less than 5 seconds at full output voltage. It supports DIN rail mounting and can operate in ambient air temperatures ranging from 0 to +40°C. The current consumption is 1.1A at a 24Vdc input, and it is designed for DC networks. Visual position indicators include Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. It is advised not to use the DC-UPS in parallel to increase output power, but paralleling two units for 1+1 redundancy is possible for higher system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. The efficiency is rated at 0.978 with a 24Vdc input, and the rated power is 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W with a 24Vdc input at 0A output current and 5.5W at 10A output current. Ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. The electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output.

Puls

1